{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,11]],"date-time":"2026-10-11T19:06:30Z","timestamp":1791745590512,"version":"4.3.4"},"reference-count":122,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2026,2,9]],"date-time":"2026-02-09T00:00:00Z","timestamp":1770595200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Biosensors"],"abstract":"<jats:p>Electrochemical biosensors have reached a high degree of analytical maturity; however, only a small portion of laboratory demonstrations actually progress to commercial products. In this review, we looked non-analytically at the factors which are in place with respect to this translational gap, specifically looking into supply chain design, scale-up manufacturing strategy, regulatory\u2013quality, and more. Based on a wide range of academic and industrial literature, the paper considers how decisions about what kind of material to use, especially for material that recognizes living things, conductive material made from ink, and the material that is the actual product being made, can make a big difference in whether the product can be reproduced easily, if it will stay stable for a long time, and if it is allowed according to the rules. This review compares the dominant manufacturing paradigms\u2014roll-to-roll printing, and semiconductor-derived microfabrication\u2014and shows how the respective strengths and limitations match the different targets, costs, and risk class. This is more about making manufacturing an upstream optimization problem than treating processes as defects and quality as assurance, rather than making it an upstream optimization problem. And it does this by looking at some other big pathways for regulations in the U.S., EU, and China as well, where we get to see how those differences in classification requirements, what kind of proofs you should have, and different ways about running those quality management systems affect how quickly things can come out after developing them, and what your flexibility with customers is like when those products are already out there in the world. The study looks at some case studies: disposable glucose strips, cartridge-based blood analyzers, and new continuous monitoring systems are used to show how the exact same electrochemical ideas can result in very different commercialization issues based on the clinical context and system integration. Synthesizing those angles creates a review that can give a system level map of matching research design to industrial and regulatory realities, with the goal of making it easier for electrochemical biosensors to go from lab prototypes to ready-for-market diagnostic tools.<\/jats:p>","DOI":"10.3390\/bios16020112","type":"journal-article","created":{"date-parts":[[2026,2,9]],"date-time":"2026-02-09T12:42:42Z","timestamp":1770640962000},"page":"112","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":34,"title":["Commercial Translation of Electrochemical Biosensors: Supply Chain Strategy, Scale-Up Manufacturing, and Regulatory\u2013Quality Considerations"],"prefix":"10.3390","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0009-0009-5613-6306","authenticated-orcid":false,"given":"Gao","family":"Zhou","sequence":"first","affiliation":[{"name":"School of Management, Hunan University of Information Technology, Changsha 410151, China"},{"name":"Graduate School of International Studies, Yonsei University, Seoul 03722, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-1282-1250","authenticated-orcid":false,"given":"Haibin","family":"Liu","sequence":"additional","affiliation":[{"name":"Institute Montpellier Management, University of Montpellier, 34960 Montpellier, France"},{"name":"Graduate School of International Studies, Yonsei University, Seoul 03722, Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,2,9]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Mishra, G.K., Barfidokht, A., Tehrani, F., and Mishra, R.K. (2018). Food Safety Analysis Using Electrochemical Biosensors. Foods, 7.","DOI":"10.3390\/foods7090141"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"3184","DOI":"10.1039\/c3cs35528d","article-title":"Biosensors: Sense and Sensibility","volume":"42","author":"Turner","year":"2013","journal-title":"Chem. Soc. Rev."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1038\/s41378-022-00443-6","article-title":"Wearable and Flexible Electrochemical Sensors for Sweat Analysis: A Review","volume":"9","author":"Gao","year":"2023","journal-title":"Microsyst. Nanoeng."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1016\/j.cclet.2019.09.022","article-title":"Miniaturized Electrochemical Sensors and Their Point-of-Care Applications","volume":"31","author":"Zhang","year":"2020","journal-title":"Chin. Chem. Lett."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"100032","DOI":"10.1016\/j.talo.2021.100032","article-title":"Screen-Printed Electrodes: Transitioning the Laboratory in-to-the Field","volume":"3","author":"Banks","year":"2021","journal-title":"Talanta Open"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"4558","DOI":"10.3390\/s100504558","article-title":"Glucose Biosensors: An Overview of Use in Clinical Practice","volume":"10","author":"Yoo","year":"2010","journal-title":"Sensors"},{"key":"ref_7","first-page":"152505","article-title":"Wasted Poly(ethylene terephthalate)-Derived Composite Xerogel with Enhanced Electromagnetic Interference Shielding and Photothermal Conversion","volume":"15","author":"Gao","year":"2025","journal-title":"J. Nanostruct. Chem."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"20170643","DOI":"10.1259\/bjr.20170643","article-title":"Commentary: How Will Interventional Oncology Navigate the \u201cValleys of Death\u201d for New Medical Devices?","volume":"91","author":"Sharma","year":"2018","journal-title":"Br. J. Radiol."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Amen, M.T., Pham, T.T.T., Cheah, E., Tran, D.P., and Thierry, B. (2022). Metal-Oxide FET Biosensor for Point-of-Care Testing: Overview and Perspective. Molecules, 27.","DOI":"10.3390\/molecules27227952"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1234","DOI":"10.1039\/D4SD00088A","article-title":"A Holistic Pathway to Biosensor Translation","volume":"3","author":"Souto","year":"2024","journal-title":"Sens. Diagn."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"13359","DOI":"10.1039\/D5CC02322J","article-title":"Maximising the Translation Potential of Electrochemical Biosensors","volume":"61","author":"Docherty","year":"2025","journal-title":"Chem. Commun."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"105909","DOI":"10.1016\/j.esmoop.2025.105909","article-title":"Regulation of Laboratory-Developed Tests and In-House In Vitro Diagnostic Medical Devices in the United States and the European Union\u2014A Comparative Overview","volume":"10","author":"Kahles","year":"2025","journal-title":"ESMO Open"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"100748","DOI":"10.1016\/j.pursup.2022.100748","article-title":"Improving Resilience of the Healthcare Supply Chain in a Pandemic: Evidence from Europe during the COVID-19 Crisis","volume":"28","author":"Spieske","year":"2022","journal-title":"J. Purch. Supply Manag."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1057\/s42214-020-00062-w","article-title":"What Does the COVID-19 Pandemic Teach Us about Global Value Chains? The Case of Medical Supplies","volume":"3","author":"Gereffi","year":"2020","journal-title":"J. Int. Bus. Policy"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1482","DOI":"10.1021\/acs.analchem.4c05786","article-title":"Screen-Printing vs Additive Manufacturing Approaches: Recent Aspects and Trends Involving the Fabrication of Electrochemical Sensors","volume":"97","author":"Orzari","year":"2025","journal-title":"Anal. Chem."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"102493","DOI":"10.1016\/j.tre.2021.102493","article-title":"The Effects of Supply Chain Diversification during the COVID-19 Crisis: Evidence from Chinese Manufacturers","volume":"155","author":"Lin","year":"2021","journal-title":"Transp. Res. E Logist. Transp. Rev."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Luo, Y., Pehrsson, M., Langholm, L., Karsdal, M., Bay-Jensen, A.-C., and Sun, S. (2023). Lot-to-Lot Variance in Immunoassays\u2014Causes, Consequences, and Solutions. Diagnostics, 13.","DOI":"10.3390\/diagnostics13111835"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Kerr, E., Alexander, R., Francis, P.S., Guijt, R.M., Barbante, G.J., and Doeven, E.H. (2021). A Comparison of Commercially Available Screen-Printed Electrodes for Electrogenerated Chemiluminescence Applications. Front. Chem., 8.","DOI":"10.3389\/fchem.2020.628483"},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Sheraz, M., Sun, X.-F., Siddiqui, A., Wang, Y., Hu, S., and Sun, R. (2025). Cellulose-Based Electrochemical Sensors. Sensors, 25.","DOI":"10.3390\/s25030645"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.microrel.2016.07.150","article-title":"RoHS Compliance in Safety and Reliability Critical Electronics","volume":"65","author":"George","year":"2016","journal-title":"Microelectron. Reliab."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1007\/s13563-021-00249-4","article-title":"Firms\u2019 Approach to Mitigating Risks in the Platinum Group Metals Sector","volume":"34","author":"Baskaran","year":"2021","journal-title":"Miner. Econ."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"e2100057","DOI":"10.1002\/elsa.202100057","article-title":"Paper-Based Electrochemical Sensor","volume":"2","author":"Sun","year":"2022","journal-title":"Electrochem. Sci. Adv."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"4906","DOI":"10.1021\/acs.analchem.1c04226","article-title":"ACEstat: A DIY Guide to Unlocking the Potential of Integrated Circuit Potentiostats for Open-Source Electrochemical Analysis","volume":"94","author":"Brown","year":"2022","journal-title":"Anal. Chem."},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Sun, G., Wei, X., Zhang, D., Huang, L., Liu, H., and Fang, H. (2023). Immobilization of Enzyme Electrochemical Biosensors and Their Application to Food Bioprocess Monitoring. Biosensors, 13.","DOI":"10.20944\/preprints202308.1310.v1"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"10866","DOI":"10.1038\/s41598-025-95682-8","article-title":"A Life Cycle Assessment Approach to Minimize Environmental Impact for Sustainable Printed Sensors","volume":"15","author":"Zikulnig","year":"2025","journal-title":"Sci. Rep."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1007\/s11095-021-03008-w","article-title":"Grand Challenges in Pharmaceutical Research Series: Ridding the Cold Chain for Biologics","volume":"38","author":"Yu","year":"2021","journal-title":"Pharm. Res."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1410","DOI":"10.1039\/D2LC00552B","article-title":"Recent Advances in Gold Electrode Fabrication for Low-Resource Setting Biosensing","volume":"23","author":"Zamani","year":"2023","journal-title":"Lab Chip"},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Soon, G.H., Deasy, M., and Dempsey, E. (2021). An Electrochemical Evaluation of Novel Ferrocene Derivatives for Glutamate and Liver Biomarker Biosensing. Biosensors, 11.","DOI":"10.3390\/bios11080254"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.aca.2015.01.012","article-title":"Review on Synthesis of Ferrocene-Based Redox Polymers and Derivatives and Their Application in Glucose Sensing","volume":"876","author":"Saleem","year":"2015","journal-title":"Anal. Chim. Acta"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"108147","DOI":"10.1016\/j.bioelechem.2022.108147","article-title":"Poly-L-lysine-Modified with Ferrocene to Obtain a Redox Polymer for Mediated Glucose Biosensor Application","volume":"146","author":"Arriaga","year":"2022","journal-title":"Bioelectrochemistry"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"113793","DOI":"10.1016\/j.microrel.2020.113793","article-title":"Analysis of Counterfeit Electronics","volume":"114","author":"Mura","year":"2020","journal-title":"Microelectron. Reliab."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1830","DOI":"10.1016\/j.jsps.2022.10.013","article-title":"Just-in-Time Approach in Healthcare Inventory Management: Does It Really Work?","volume":"30","author":"Balkhi","year":"2022","journal-title":"Saudi Pharm. J."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"109352","DOI":"10.1016\/j.ijpe.2024.109352","article-title":"What Are the Right Configurations of Just-in-Time and Just-in-Case When Supply Chain Shocks Increase?","volume":"276","author":"Yu","year":"2024","journal-title":"Int. J. Prod. Econ."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1021\/acsmeasuresciau.3c00034","article-title":"Advances in Bioelectrode Design for Developing Electrochemical Biosensors","volume":"3","author":"Kalita","year":"2023","journal-title":"ACS Meas. Sci. Au"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"6978","DOI":"10.1021\/acsnano.8b02505","article-title":"Roll-to-Roll Gravure Printed Electrochemical Sensors for Wearable and Medical Devices","volume":"12","author":"Bariya","year":"2018","journal-title":"ACS Nano"},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Phung, T.H., Gafurov, A.N., Kim, I., Kim, S.Y., Kim, K.M., and Lee, T.-M. (2023). Hybrid Device Fabrication Using Roll-to-Roll Printing for Personal Environmental Monitoring. Polymers, 15.","DOI":"10.3390\/polym15122687"},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Sardini, E., Serpelloni, M., and Tonello, S. (2020). Printed Electrochemical Biosensors: Opportunities and Metrological Challenges. Biosensors, 10.","DOI":"10.3390\/bios10110166"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"2482","DOI":"10.1021\/cr068069y","article-title":"Electrochemical Glucose Sensors and Their Applications in Diabetes Management","volume":"108","author":"Heller","year":"2008","journal-title":"Chem. Rev."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"2200173","DOI":"10.1002\/admt.202200173","article-title":"Real-Time Metrology for Roll-To-Roll and Advanced Inline Manufacturing: A Review","volume":"8","author":"Maize","year":"2023","journal-title":"Adv. Mater. Technol."},{"key":"ref_40","doi-asserted-by":"crossref","unstructured":"Wiklund, J., Karako\u00e7, A., Palko, T., Yi\u011fitler, H., Ruttik, K., J\u00e4ntti, R., and Paltakari, J. (2021). A Review on Printed Electronics: Fabrication Methods, Inks, Substrates, Applications and Environmental Impacts. J. Manuf. Mater. Process., 5.","DOI":"10.20944\/preprints202106.0017.v1"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"6255","DOI":"10.1007\/s00170-022-08717-z","article-title":"Accuracy Control for Roll and Sheet Processed Printed Electronics on Flexible Plastic Substrates","volume":"119","author":"Jansson","year":"2022","journal-title":"Int. J. Adv. Manuf. Technol."},{"key":"ref_42","doi-asserted-by":"crossref","unstructured":"Liu, B., Chen, Y., Xie, J., and Chen, B. (2023). Industrial Roll-to-Roll Printing Register Control Using a Pulse-Width Subdivision Detection Algorithm. Appl. Sci., 13.","DOI":"10.3390\/app13095307"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"112428","DOI":"10.1016\/j.bios.2020.112428","article-title":"Fully-Printed Electrochemical Sensors Made with Flexible Screen-Printed Electrodes Modified by Roll-to-Roll Slot-Die Coating","volume":"165","author":"Cagnani","year":"2020","journal-title":"Biosens. Bioelectron."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"2501322","DOI":"10.1002\/adem.202501322","article-title":"Advances in Screen-Printed Conductive Inks for Sustainable and High-Performance E-Textiles: Innovations, Challenges, and Future Prospects","volume":"27","author":"Batine","year":"2025","journal-title":"Adv. Eng. Mater."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"e30163","DOI":"10.1016\/j.heliyon.2024.e30163","article-title":"Inkjet Printing Quality Improvement Research Progress: A Review","volume":"10","author":"Cao","year":"2024","journal-title":"Heliyon"},{"key":"ref_46","doi-asserted-by":"crossref","unstructured":"Reddy Gajjala, R.K., Mu\u00f1ana-Gonz\u00e1lez, S., N\u00fa\u00f1ez-Marinero, P., Totoricaguena-Gorri\u00f1o, J., Ruiz-Rubio, L., and del Campo, F.J. (2024). Design and Fabrication of Wearable Biosensors: Materials, Methods, and Prospects. Wearable Biosensing in Medicine and Healthcare, Springer.","DOI":"10.1007\/978-981-99-8122-9_15"},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Kosri, E., Ibrahim, F., Thiha, A., and Madou, M. (2022). Micro and Nano Interdigitated Electrode Array (IDEA)-Based MEMS\/NEMS as Electrochemical Transducers: A Review. Nanomaterials, 12.","DOI":"10.3390\/nano12234171"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"100257","DOI":"10.1016\/j.mne.2024.100257","article-title":"Fabrication of Pyrolytic Carbon Interdigitated Microelectrodes by Maskless UV Photolithography with Epoxy-Based Photoresists SU-8 and mr-DWL","volume":"23","author":"Rezaei","year":"2024","journal-title":"Micro Nano Eng."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1016\/j.bios.2019.03.055","article-title":"A Review of Microfabricated Electrochemical Biosensors for DNA Detection","volume":"134","author":"Blair","year":"2019","journal-title":"Biosens. Bioelectron."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"061502","DOI":"10.1063\/5.0071176","article-title":"Low-Cost and Cleanroom-Free Prototyping of Microfluidic and Electrochemical Biosensors: Techniques in Fabrication and Bioconjugation","volume":"15","author":"Nordin","year":"2021","journal-title":"Biomicrofluidics"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"115503","DOI":"10.1016\/j.bios.2023.115503","article-title":"Silicon Microfabrication Technologies for Biology Integrated Advance Devices and Interfaces","volume":"237","author":"Juska","year":"2023","journal-title":"Biosens. Bioelectron."},{"key":"ref_52","doi-asserted-by":"crossref","unstructured":"Charmet, J., Rodrigues, R., Yildirim, E., Challa, P.K., Roberts, B., Dallmann, R., and Whulanza, Y. (2020). Low-Cost Microfabrication Tool Box. Micromachines, 11.","DOI":"10.3390\/mi11020135"},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"e1806739","DOI":"10.1002\/adma.201806739","article-title":"Disposable Sensors in Diagnostics, Food, and Environmental Monitoring","volume":"31","author":"Dincer","year":"2019","journal-title":"Adv. Mater."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"1484","DOI":"10.1021\/accountsmr.4c00170","article-title":"Top-Down Fabrication of Chemical and Biological Sensors","volume":"5","author":"Kang","year":"2024","journal-title":"Acc. Mater. Res."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"2010","DOI":"10.1021\/acssensors.0c00404","article-title":"Roll-to-Roll Manufacturing of Integrated Immunodetection Sensors","volume":"5","author":"Liedert","year":"2020","journal-title":"ACS Sens."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/j.snb.2014.08.065","article-title":"Novel Fabrication Process for Sub-Micron Interdigitated Electrode Arrays for Highly Sensitive Electrochemical Detection","volume":"205","author":"Partel","year":"2014","journal-title":"Sens. Actuators B Chem."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"137","DOI":"10.2147\/MDER.S448049","article-title":"Engineering a Quality Management System for Academic Research: Navigating Challenges to Comply with the New Medical Device Regulations in Europe","volume":"18","author":"Buist","year":"2025","journal-title":"Med. Devices"},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1007\/s00604-022-05548-3","article-title":"Micro- and Nano-Devices for Electrochemical Sensing","volume":"189","author":"Mariani","year":"2022","journal-title":"Microchim. Acta"},{"key":"ref_59","doi-asserted-by":"crossref","unstructured":"Nag, A., Mukhopadhyay, S.C., and Kosel, J. (2019). Printed Flexible Sensors, Springer.","DOI":"10.1007\/978-3-030-13765-6"},{"key":"ref_60","doi-asserted-by":"crossref","unstructured":"Zavanelli, N., Kim, J., and Yeo, W.-H. (2021). Recent Advances in High-Throughput Nanomaterial Manufacturing for Hybrid Flexible Bioelectronics. Materials, 14.","DOI":"10.3390\/ma14112973"},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"1679","DOI":"10.3390\/s100301679","article-title":"Microfabricated Reference Electrodes and Their Biosensing Applications","volume":"10","author":"Shinwari","year":"2010","journal-title":"Sensors"},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"8859","DOI":"10.1038\/s41598-025-93025-1","article-title":"A Novel Strategy for Controllable Electrofabrication of Molecularly Imprinted Polymer Biosensors Utilizing Embedded Prussian Blue Nanoparticles","volume":"15","author":"Babamiri","year":"2025","journal-title":"Sci. Rep."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1021\/acs.analchem.2c04541","article-title":"In Vivo Electrochemical Biosensors: Recent Advances in Molecular Design, Electrode Materials, and Electrochemical Devices","volume":"95","author":"Wang","year":"2023","journal-title":"Anal. Chem."},{"key":"ref_64","first-page":"49","article-title":"Implantable Electrochemical Microsensors for In Vivo Monitoring of Animal Physiological Information","volume":"16","author":"Zhou","year":"2023","journal-title":"Nanomicro Lett."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/j.coelec.2017.05.003","article-title":"Inkjet-Printed Electrochemical Sensors","volume":"3","author":"Moya","year":"2017","journal-title":"Curr. Opin. Electrochem."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"8","DOI":"10.9734\/jpri\/2023\/v35i137365","article-title":"Implementing a Risk-Based Approach to Quality Management System ISO-13485 Processes in Compliance with EUMDR 2017\/745 for Medical Device Industry","volume":"35","author":"Sharma","year":"2023","journal-title":"J. Pharm. Res. Int."},{"key":"ref_67","doi-asserted-by":"crossref","unstructured":"Hussain, A., Abbas, N., and Ali, A. (2022). Inkjet Printing: A Viable Technology for Biosensor Fabrication. Chemosensors, 10.","DOI":"10.3390\/chemosensors10030103"},{"key":"ref_68","doi-asserted-by":"crossref","unstructured":"Paimard, G., Ghasali, E., and Baeza, M. (2023). Screen-Printed Electrodes: Fabrication, Modification, and Biosensing Applications. Chemosensors, 11.","DOI":"10.3390\/chemosensors11020113"},{"key":"ref_69","doi-asserted-by":"crossref","unstructured":"Ganguly, P., Neethipathi, D.K., Beniwal, A., and Dahiya, R. (2022). Influence of Thickness of Screen Printed Carbon Electrodes on Electrochemical Sensing. 2022 IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS), Vienna, Austria, 10\u201313 July 2022, IEEE.","DOI":"10.1109\/FLEPS53764.2022.9781549"},{"key":"ref_70","doi-asserted-by":"crossref","unstructured":"Zhang, Y., Hu, G., Liu, Y., Wang, J., Yang, G., and Li, D. (2022). Suppression and Utilization of Satellite Droplets for Inkjet Printing: A Review. Processes, 10.","DOI":"10.3390\/pr10050932"},{"key":"ref_71","doi-asserted-by":"crossref","unstructured":"Bunday, B., Allgair, J., Adan, O., Tam, A., Latinski, S., and Eytan, G. (2006). Small Feature Accuracy Challenge for CD-SEM Metrology: Physical Model Solution. Metrology, Inspection, and Process Control for Microlithography XX, SPIE.","DOI":"10.1117\/12.659779"},{"key":"ref_72","first-page":"033006","article-title":"Image Placement Error: Closing the Gap between Overlay and Imaging","volume":"4","author":"Hendrickx","year":"2005","journal-title":"J. Micro\/Nanopatterning Mater. Metrol."},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1016\/j.biotechadv.2011.09.003","article-title":"Immobilization Strategies to Develop Enzymatic Biosensors","volume":"30","author":"Sassolas","year":"2012","journal-title":"Biotechnol. Adv."},{"key":"ref_74","doi-asserted-by":"crossref","unstructured":"Nguyen, H.H., Lee, S.H., Lee, U.J., Fermin, C.D., and Kim, M. (2019). Immobilized Enzymes in Biosensor Applications. Materials, 12.","DOI":"10.3390\/ma12010121"},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"1167","DOI":"10.1021\/acssensors.6b00553","article-title":"Medical Sensors\u2014Defining a Pathway to Commercialization","volume":"1","author":"Mazzocchi","year":"2016","journal-title":"ACS Sens."},{"key":"ref_76","doi-asserted-by":"crossref","unstructured":"Pannonhalmi, \u00c1., Sipos, B., Kurucz, R.I., Katona, G., Kem\u00e9ny, L., and Cs\u00f3ka, I. (2025). Advancing Regulatory Oversight of Medical Device Trials to Align with Clinical Drug Standards in the European Union. Pharmaceuticals, 18.","DOI":"10.3390\/ph18060876"},{"key":"ref_77","doi-asserted-by":"crossref","first-page":"927","DOI":"10.1007\/s12265-022-10232-1","article-title":"Navigating the Regulatory Pathway for Medical Devices\u2014A Conversation with the FDA, Clinicians, Researchers, and Industry Experts","volume":"15","author":"Lottes","year":"2022","journal-title":"J. Cardiovasc. Transl. Res."},{"key":"ref_78","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1186\/s13731-024-00439-8","article-title":"MediGate: A MedTech Product Innovation Development Process from University Research to Successful Commercialization within Emerging Markets","volume":"13","author":"Kruachottikul","year":"2024","journal-title":"J. Innov. Entrep."},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1007\/s10916-023-01986-5","article-title":"The 510(k) Third Party Review Program: Promise and Potential","volume":"47","author":"Miller","year":"2023","journal-title":"J. Med. Syst."},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"1558","DOI":"10.7326\/ANNALS-24-00728","article-title":"Modernizing Medical Device Regulation: Challenges and Opportunities for the 510(k) Clearance Process","volume":"177","author":"Kadakia","year":"2024","journal-title":"Ann. Intern. Med."},{"key":"ref_81","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1016\/j.jpubeco.2016.11.010","article-title":"Innovation under Regulatory Uncertainty: Evidence from Medical Technology","volume":"145","author":"Stern","year":"2017","journal-title":"J. Public Econ."},{"key":"ref_82","unstructured":"Lewin, A. (2025, December 01). Medical Device Innovation in America: Tensions Between Food and Drug Law and Patent. Available online: https:\/\/jolt.law.harvard.edu\/articles\/pdf\/v26\/26HarvJLTech403.pdf."},{"key":"ref_83","doi-asserted-by":"crossref","first-page":"021015","DOI":"10.1115\/1.4006781","article-title":"Medical Device Innovators and the 510(k) Regulatory Pathway: Implications of a Survey-Based Assessment of Industry Experience","volume":"6","author":"Pietzsch","year":"2012","journal-title":"J. Med. Devices"},{"key":"ref_84","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1128\/CMR.00074-09","article-title":"Validation of Laboratory-Developed Molecular Assays for Infectious Diseases","volume":"23","author":"Burd","year":"2010","journal-title":"Clin. Microbiol. Rev."},{"key":"ref_85","unstructured":"(2026, January 06). Senseonics Announces CE Mark Approval of the Eversense\u00ae CGM System. Available online: https:\/\/www.senseonics.com\/investor-relations\/news-releases\/2016\/05-10-2016-224122137."},{"key":"ref_86","unstructured":"U.S. Food and Drug Administration (2026, January 06). Premarket Approval (PMA), Available online: https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpma\/pma.cfm?id=P160048S021&utm_source=chatgpt.com."},{"key":"ref_87","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3897\/pharmacia.72.e175312","article-title":"Transformation of European Medical Device Regulation: The Role of Expert Panels","volume":"72","author":"Simova","year":"2025","journal-title":"Pharmacia"},{"key":"ref_88","doi-asserted-by":"crossref","first-page":"1150","DOI":"10.1515\/cclm-2022-1252","article-title":"Clinical Evidence Requirements According to the IVDR 2017\/746: Practical Tools and References for Underpinning Clinical Evidence of IVD-MDs","volume":"61","author":"Pazart","year":"2023","journal-title":"Clin. Chem. Lab. Med."},{"key":"ref_89","first-page":"89","article-title":"Advancing Medical Device Regulatory Reforms for Innovation, Translation and Industry Development in China","volume":"37","author":"Song","year":"2022","journal-title":"J. Orthop. Transl."},{"key":"ref_90","first-page":"290","article-title":"Importance to Understand Medical Device Regulations for Accelerating Clinical Translation","volume":"51","author":"Lu","year":"2025","journal-title":"J. Orthop. Transl."},{"key":"ref_91","doi-asserted-by":"crossref","unstructured":"Di Novo, N.G., Cant\u00f9, E., Tonello, S., Sardini, E., and Serpelloni, M. (2019). Support-Material-Free Microfluidics on an Electrochemical Sensors Platform by Aerosol Jet Printing. Sensors, 19.","DOI":"10.3390\/s19081842"},{"key":"ref_92","first-page":"2968","article-title":"Disposable Electrochemical Sensors and Biosensors for Environmental and Food Analysis","volume":"42","author":"Laschi","year":"2003","journal-title":"Indian J. Chem. A"},{"key":"ref_93","first-page":"152502","article-title":"Ti3C2 MXene-Enhanced Electrochemical Biosensors for Prostate-Specific Antigen (PSA) Detection in Prostate Cancer","volume":"15","author":"Jia","year":"2025","journal-title":"J. Nanostruct. Chem."},{"key":"ref_94","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1038\/s41378-024-00700-w","article-title":"Electrochemical Protein Biosensors for Disease Marker Detection: Progress and Opportunities","volume":"10","author":"Guo","year":"2024","journal-title":"Microsyst. Nanoeng."},{"key":"ref_95","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1039\/D2SD00226D","article-title":"Carbon-Based Electrochemical Biosensors as Diagnostic Platforms for Connected Decentralized Healthcare","volume":"2","author":"Khan","year":"2023","journal-title":"Sens. Diagn."},{"key":"ref_96","unstructured":"(2019). Medical Devices\u2014Application of Risk Management to Medical Devices (Standard No. ISO 14971:2019)."},{"key":"ref_97","unstructured":"Goode, J.A. (2015). Development of Biosensors Using Novel Bioreceptors; Investigation and Optimisation of Fundamental Parameters at the Nanoscale. [Ph.D. Thesis, University of Leeds]."},{"key":"ref_98","first-page":"7336","article-title":"A Review on Recent Trends and Future Developments in Electrochemical Sensing","volume":"9","author":"Singh","year":"2024","journal-title":"ACS Omega"},{"key":"ref_99","doi-asserted-by":"crossref","unstructured":"Das, A., Borthakur, P.P., Das, D., Sahariah, J.J., Kalita, P., and Pathak, K. (2025). Emerging Trends in Paper-Based Electrochemical Biosensors for Healthcare Applications. Eng. Proc., 106.","DOI":"10.3390\/engproc2025106008"},{"key":"ref_100","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1515\/cclm-2015-0130","article-title":"Accuracy and Precision Assessment of a New Blood Glucose Monitoring System","volume":"54","author":"Ji","year":"2016","journal-title":"Clin. Chem. Lab. Med."},{"key":"ref_101","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1177\/1932296818804837","article-title":"Evaluation of Analytical Performance of Three Blood Glucose Monitoring Systems: System Accuracy, Measurement Repeatability, and Intermediate Measurement Precision","volume":"13","author":"Pleus","year":"2019","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_102","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1515\/cclm-2024-0595","article-title":"Critical Appraisal of the CLSI Guideline EP09c \u201cMeasurement Procedure Comparison and Bias Estimation Using Patient Samples\u201d","volume":"63","author":"Cesana","year":"2025","journal-title":"Clin. Chem. Lab. Med."},{"key":"ref_103","doi-asserted-by":"crossref","first-page":"1061","DOI":"10.1177\/1932296815586016","article-title":"Performance and System Validation of a New Cellular-Enabled Blood Glucose Monitoring System Using a New Standard Reference Measurement Procedure of Isotope Dilution UPLC-MRM Mass Spectrometry","volume":"9","author":"Angelides","year":"2015","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_104","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1373\/jalm.2016.020735","article-title":"Verification of Claimed Limit of Detection in Molecular Diagnostics","volume":"1","author":"Vaks","year":"2016","journal-title":"J. Appl. Lab. Med."},{"key":"ref_105","doi-asserted-by":"crossref","first-page":"849","DOI":"10.1002\/jcla.21947","article-title":"Analytical Performance Evaluation of Infopia ElementTM Auto-coding Blood Glucose Monitoring System for Self-Monitoring of Blood Glucose","volume":"30","author":"Park","year":"2016","journal-title":"J. Clin. Lab. Anal."},{"key":"ref_106","doi-asserted-by":"crossref","first-page":"734","DOI":"10.1177\/1932296818821664","article-title":"Evaluation of Linearity and Interference Effect on SMBG and POCT Devices, Showing Drastic High Values, Low Values, or Error Messages","volume":"13","author":"Sai","year":"2019","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_107","doi-asserted-by":"crossref","first-page":"971","DOI":"10.1177\/19322968241231294","article-title":"Investigation of the Effect of 70 Potential Interferents on Measurement Results of Two Blood Glucose Monitoring Systems","volume":"19","author":"Baumstark","year":"2024","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_108","doi-asserted-by":"crossref","unstructured":"Khosravi, S., Soltanian, S., Servati, A., Khademhosseini, A., Zhu, Y., and Servati, P. (2023). Screen-Printed Textile-Based Electrochemical Biosensor for Noninvasive Monitoring of Glucose in Sweat. Biosensors, 13.","DOI":"10.3390\/bios13070684"},{"key":"ref_109","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1016\/j.talanta.2017.04.011","article-title":"Determination of Stability Characteristics for Electrochemical Biosensors via Thermally Accelerated Ageing","volume":"170","author":"Panjan","year":"2017","journal-title":"Talanta"},{"key":"ref_110","doi-asserted-by":"crossref","first-page":"100383","DOI":"10.1016\/j.sftr.2024.100383","article-title":"Digitalised Validation Systems as an Enabler for Quality 4.0 within a Medical Device Manufacturer","volume":"8","author":"McDermott","year":"2024","journal-title":"Sustain. Futures"},{"key":"ref_111","unstructured":"Center for Devices and Radiological Health (2026, January 06). The 510(k) Program: Evaluating Substantial Equivalence in Premarket Notifications [510(k)]. U.S. Food and Drug Administration. 2019, Available online: https:\/\/www.fda.gov\/regulatory-information\/search-fda-guidance-documents\/510k-program-evaluating-substantial-equivalence-premarket-notifications-510k."},{"key":"ref_112","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1136\/jcp.2006.037820","article-title":"Accuracy and Clinical Utility of the CoaguChek XS Portable International Normalised Ratio Monitor in a Pilot Study of Warfarin Home-Monitoring","volume":"60","author":"Bereznicki","year":"2007","journal-title":"J. Clin. Pathol."},{"key":"ref_113","unstructured":"(2026, January 06). i-STAT 1. Available online: https:\/\/www.globalpointofcare.abbott\/us\/en\/product-details\/apoc\/i-stat-system-us.html."},{"key":"ref_114","unstructured":"U.S. Food and Drug Administration (2026, January 06). 510(k) Premarket Notification (K191360), Available online: https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpmn\/pmn.cfm?ID=k191360."},{"key":"ref_115","unstructured":"U.S. Food and Drug Administration (2026, January 06). 510(k) Premarket Notification (K200107), Available online: https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpmn\/pmn.cfm?ID=K200107."},{"key":"ref_116","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1007\/s44371-024-00042-6","article-title":"Biocompatible Materials for Next-Generation Biosensors","volume":"1","author":"Gideon","year":"2024","journal-title":"Discov. Chem."},{"key":"ref_117","doi-asserted-by":"crossref","unstructured":"Ou, Y., Han, Z., Cai, S., Heck, J.R., Toprakcioglu, Z., Yu, Z., Weitz, D.A., and Knowles, T.P.J. (2026). Biomaterials with Droplet Microfluidics. Nat. Rev. Bioeng., 1\u201318.","DOI":"10.1038\/s44222-025-00389-0"},{"key":"ref_118","unstructured":"Office of the Commissioner (2026, January 06). FDA Roundup: April 21, 2023. U.S. Food and Drug Administration. 2024, Available online: https:\/\/www.fda.gov\/news-events\/press-announcements\/fda-roundup-april-21-2023."},{"key":"ref_119","doi-asserted-by":"crossref","first-page":"104906","DOI":"10.1016\/j.tifs.2025.104906","article-title":"Rethinking Single-Use Plastics: Innovations, Polices, Consumer Awareness and Market Shaping Biodegradable Solutions in the Packaging Industry","volume":"158","author":"Barone","year":"2025","journal-title":"Trends Food Sci. Technol."},{"key":"ref_120","unstructured":"(2026, January 06). Federal Register. Medical Devices; Clinical Chemistry and Clinical Toxicology Devices; Classification of the Integrated Continuous Glucose Monitoring System. 2022, Available online: https:\/\/www.federalregister.gov\/documents\/2022\/02\/18\/2022-03504\/medical-devices-clinical-chemistry-and-clinical-toxicology-devices-classification-of-the-integrated?utm_source=chatgpt.com."},{"key":"ref_121","doi-asserted-by":"crossref","first-page":"e42057","DOI":"10.2196\/42057","article-title":"Usability and Teachability of Continuous Glucose Monitoring Devices in Older Adults and Diabetes Educators: Task Analysis and Ease-of-Use Survey","volume":"9","author":"Psavko","year":"2022","journal-title":"JMIR Hum. Factors"},{"key":"ref_122","doi-asserted-by":"crossref","unstructured":"Shakeel, A., Maskey, B.B., Shrestha, S., Parajuli, S., Jung, Y., and Cho, G. (2023). Towards Digital Twin Implementation in Roll-to-Roll Gravure Printed Electronics: Overlay Printing Registration Error Prediction Based on Printing Process Parameters. Nanomaterials, 13.","DOI":"10.3390\/nano13061008"}],"container-title":["Biosensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2079-6374\/16\/2\/112\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,9]],"date-time":"2026-02-09T13:16:21Z","timestamp":1770642981000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2079-6374\/16\/2\/112"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,9]]},"references-count":122,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2026,2]]}},"alternative-id":["bios16020112"],"URL":"https:\/\/doi.org\/10.3390\/bios16020112","relation":{},"ISSN":["2079-6374"],"issn-type":[{"value":"2079-6374","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,9]]}}}