{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T17:40:10Z","timestamp":1776447610527,"version":"3.51.2"},"reference-count":21,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T00:00:00Z","timestamp":1776384000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Brain Sciences"],"abstract":"<jats:p>Background: Active middle ear implants (AMEIs) provide an alternative auditory rehabilitation strategy for patients who cannot tolerate conventional hearing aids. However, clinical data regarding the outcomes of Vibrant Soundbridge (VSB) implantation using the incus short process (SP) coupler in older adults remain limited. Objective: This study aimed to evaluate the audiological outcomes, patient-reported hearing benefits, tinnitus improvement, and surgical safety of VSB implantation using the SP coupler in older adults with bilateral sloping sensorineural hearing loss. Methods: This retrospective study included 45 older male veterans (mean age 76.1 \u00b1 5.3 years) with bilateral sloping sensorineural hearing loss who underwent unilateral VSB implantation with the SP coupler between 2019 and 2023. Functional hearing gain was assessed using preoperative and postoperative sound-field pure-tone thresholds. Patient-reported outcomes were evaluated using the Speech, Spatial and Qualities of Hearing Scale (SSQ) and the Tinnitus Handicap Inventory (THI). Operative characteristics and postoperative complications were also analyzed. Results: Mean operative time was 40.2 \u00b1 8.7 min. Functional hearing gain increased progressively across speech-critical frequencies, reaching +20 dB at 2 kHz and +30 dB at 4 kHz. The mean four-frequency pure tone average improved from 57.4 \u00b1 8.3 dB HL preoperatively to 35.6 \u00b1 6.9 dB HL postoperatively (p &lt; 0.001). All SSQ subdomains showed significant improvement (p &lt; 0.001). THI scores decreased significantly from 43.2 \u00b1 8.4 to 17.1 \u00b1 6.2 (p &lt; 0.0001), with clinically meaningful tinnitus improvement observed in 75.6% of patients. No major surgical complications occurred. Conclusions: Vibrant Soundbridge implantation using the incus short process coupler provides effective auditory rehabilitation for older adults with sloping sensorineural hearing loss. The procedure yields meaningful high-frequency hearing gain, improved hearing-related quality of life, and significant tinnitus reduction while maintaining a favorable surgical safety profile. Restoration of auditory input through active middle ear implantation may also contribute to improved central auditory processing in older adults.<\/jats:p>","DOI":"10.3390\/brainsci16040423","type":"journal-article","created":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T16:30:36Z","timestamp":1776443436000},"page":"423","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Auditory and Tinnitus Outcomes of Vibrant Soundbridge Implantation with the Incus Short Process Coupler in Older Male Veterans"],"prefix":"10.3390","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4084-2301","authenticated-orcid":false,"given":"Chul Ho","family":"Jang","sequence":"first","affiliation":[{"name":"Department of Otolaryngology, Gwangju Veterans Hospital, Gwangju 62284, Republic of Korea"},{"name":"Department of Otolaryngology, Chonnam National University Medical School, Gwangju 61469, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Do Yeon","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology, Gwangju Veterans Hospital, Gwangju 62284, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2026,4,17]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1186\/s13195-024-01586-6","article-title":"Relationship between hearing impairment and dementia and cognitive function: A Mendelian randomization study","volume":"16","author":"Jiang","year":"2024","journal-title":"Alzheimer\u2019s Res. Ther."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"786","DOI":"10.1016\/S0140-6736(23)01406-X","article-title":"Hearing intervention versus health education control to reduce cognitive decline in older adults with hearing loss in the USA (ACHIEVE): A multicentre, randomised controlled trial","volume":"402","author":"Lin","year":"2023","journal-title":"Lancet"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1097\/MAO.0b013e3181cabd42","article-title":"Active middle ear implant compared with open-fit hearing aid in sloping high-frequency sensorineural hearing loss","volume":"31","author":"Boeheim","year":"2010","journal-title":"Otol. Neurotol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1159\/000516144","article-title":"Long-Term Safety and Quality of Life After Vibroplasty in Sensorineural Hearing Loss: Short\/Long Incus Process Coupler","volume":"27","author":"Edlinger","year":"2022","journal-title":"Audiol. Neurootol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1097\/MAO.0000000000004678","article-title":"Lifetime Real-World Evidence on Safety and Performance of the Only Active Middle Ear Implant (AMEI) Covering Conductive to Sensorineural Hearing Loss: Results From a Long-Term Retrospective Analysis","volume":"47","author":"Lenarz","year":"2026","journal-title":"Otol. Neurotol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1080\/14992027.2022.2031317","article-title":"Comparison between incus short process and long process coupling of the vibrant soundbridge in human temporal bones","volume":"62","author":"Graf","year":"2023","journal-title":"Int. J. Audiol."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Kishore, A., and Dutt, S.N. (2025). Middle Ear Implants: Surgical Perspectives. Advances in Implantation Otology, Springer.","DOI":"10.1007\/978-981-96-8671-1_9"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"218","DOI":"10.14639\/0392-100X-1146","article-title":"Benefits of active middle ear implants over hearing aids in patients with sloping high tone hearing loss: Comparison with hearing aids","volume":"37","author":"Lee","year":"2017","journal-title":"Acta Otorhinolaryngol. Ital."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"688","DOI":"10.1097\/MAO.0000000000001830","article-title":"Surgical Impact of Coupling an Active Middle Ear Implant to Short Incus Process","volume":"39","author":"Schraven","year":"2018","journal-title":"Otol. Neurotol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1007\/s00405-020-06064-x","article-title":"A retrospective European multicenter analysis of the functional outcomes after active middle ear implant surgery using the third generation vibroplasty couplers","volume":"278","author":"Rahne","year":"2021","journal-title":"Eur. Arch. Otorhinolaryngol."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Lee, J.M., Lee, H.J., Moon, I.S., and Choi, J.Y. (2020). Effects of Vibrant Soundbridge on tinnitus accompanied by sensorineural hearing loss. PLoS ONE, 15.","DOI":"10.1371\/journal.pone.0228498"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1080\/14992020400050014","article-title":"The Speech, Spatial and Qualities of Hearing Scale (SSQ)","volume":"43","author":"Gatehouse","year":"2004","journal-title":"Int. J. Audiol."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1001\/archotol.1996.01890140029007","article-title":"Development of the Tinnitus Handicap Inventory","volume":"122","author":"Newman","year":"1996","journal-title":"Arch. Otolaryngol. Head Neck Surg."},{"key":"ref_14","first-page":"51","article-title":"Clinical experience with the active middle ear implant Vibrant Soundbridge in sensorineural hearing loss","volume":"69","author":"Pok","year":"2010","journal-title":"Adv. Otorhinolaryngol."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Salamah, M., Alradhi, A., Alzhrani, F., and Yousef, M. (2024). Outcomes of Active Middle Ear Implants: Speech Perception and Quality of Life. J. Pers. Med., 14.","DOI":"10.20944\/preprints202407.1717.v1"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"721","DOI":"10.3390\/audiolres14040061","article-title":"Middle Ear Active Implant Indications, Comparative Audiometric Results from Different Approaches, and Coupling with the Vibrant Soundbridge\u00ae: A Single Center Experience over More Than 20 Years","volume":"14","author":"Lima","year":"2024","journal-title":"Audiol. Res."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"3076","DOI":"10.1161\/STROKEAHA.114.006668","article-title":"Hormone replacement therapy and adverse outcomes in women with atrial fibrillation: An analysis from the atrial fibrillation follow-up investigation of rhythm management trial","volume":"45","author":"Apostolakis","year":"2014","journal-title":"Stroke"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1392","DOI":"10.1002\/jmri.70188","article-title":"Multidisciplinary Protocol for 1.5 T MRI in Adult Patients with Active Implantable Medical Devices: Safety and Efficacy in a Five-Year Single-Center Experience","volume":"63","author":"Filice","year":"2025","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1451","DOI":"10.1002\/lary.25670","article-title":"Safety and effectiveness of the Vibrant Soundbridge in treating conductive and mixed hearing loss: A systematic review","volume":"126","author":"Ernst","year":"2016","journal-title":"Laryngoscope"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1002\/lary.27513","article-title":"Long-Term Outcome of Hearing Rehabilitation with An Active Middle Ear Implant","volume":"129","author":"Brkic","year":"2019","journal-title":"Laryngoscope"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"6009","DOI":"10.1007\/s00405-024-08836-1","article-title":"Open-fitting hearing aids: A comparative analysis between open behind-the-ear and open completely-in-the-canal instant-fit devices","volume":"281","author":"Alberti","year":"2024","journal-title":"Eur. Arch. Otorhinolaryngol."}],"container-title":["Brain Sciences"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2076-3425\/16\/4\/423\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T16:40:33Z","timestamp":1776444033000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2076-3425\/16\/4\/423"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,17]]},"references-count":21,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2026,4]]}},"alternative-id":["brainsci16040423"],"URL":"https:\/\/doi.org\/10.3390\/brainsci16040423","relation":{},"ISSN":["2076-3425"],"issn-type":[{"value":"2076-3425","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,17]]}}}