{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T20:19:10Z","timestamp":1790108350189,"version":"4.0.1"},"reference-count":12,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2023,12,26]],"date-time":"2023-12-26T00:00:00Z","timestamp":1703548800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Innosuisse, Swiss Agency for innovation promotion, formerly KTI","award":["44221.1 IP-LS"],"award-info":[{"award-number":["44221.1 IP-LS"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Children"],"abstract":"<jats:p>This article introduces a novel concept where advanced technologies have been leveraged to produce a modular walking orthosis (MOWA) within a completely digital process chain. All processes of this new supply chain are described step-by-step. The prescription and treatment of lower leg orthoses for individuals with paralysis or muscle weakness, particularly cerebral palsy (CP), are complex. A single case study indicates successful treatment with this new orthosis (MOWA). From the authors\u2019 perspective, this innovative fitting concept is promising and will contribute to creating more efficient care within a multidisciplinary team.<\/jats:p>","DOI":"10.3390\/children11010030","type":"journal-article","created":{"date-parts":[[2023,12,27]],"date-time":"2023-12-27T02:58:12Z","timestamp":1703645892000},"page":"30","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Novel Modular Walking Orthosis (MOWA) for Powerful Correction of Gait Deviations in Subjects with a Neurological Disease"],"prefix":"10.3390","volume":"11","author":[{"given":"Jan-Hagen","family":"Schr\u00f6der","sequence":"first","affiliation":[{"name":"MOWA Healthcare AG, 4500 Solothurn, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-4436-8315","authenticated-orcid":false,"given":"Gion A.","family":"Barandun","sequence":"additional","affiliation":[{"name":"IWK Institute for Materials Technology and Plastics Processing, Eastern Switzerland University of Applied Sciences, 8640 Rapperswil, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6659-3449","authenticated-orcid":false,"given":"Pascal","family":"Leimer","sequence":"additional","affiliation":[{"name":"Switzerland Innovation Park Biel\/Bienne, 2503 Biel, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rafael","family":"Morand","sequence":"additional","affiliation":[{"name":"Biomedical Engineering Lab, Institute for Human Centered Engineering, Bern University of Applied Sciences, 3008 Bern, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2011-3999","authenticated-orcid":false,"given":"Beat","family":"G\u00f6pfert","sequence":"additional","affiliation":[{"name":"Department Biomedical Engineering (DBE), University of Basel, 4123 Allschwil, Switzerland"},{"name":"Laboratory for Movement Analysis, University of Basel Children\u2019s Hospital (UKBB), 4056 Basel, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2292-0946","authenticated-orcid":false,"given":"Erich","family":"Rutz","sequence":"additional","affiliation":[{"name":"The Royal Children\u2019s Hospital, Melbourne, VIC 3052, Australia"},{"name":"Bob Dickens Chair Paediatric Orthopaedic Surgery, The University of Melbourne, Melbourne, VIC 3010, Australia"},{"name":"Murdoch Children\u2019s Research Institute, Melbourne, VIC 3052, Australia"},{"name":"Medical Faculty, University of Basel, 4001 Basel, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2023,12,26]]},"reference":[{"key":"ref_1","first-page":"32","article-title":"Systematic review work for the creation of an indication-based guideline for the orthopaedic treatment of lower leg orthoses","volume":"72","author":"Krieger","year":"2021","journal-title":"Orthop\u00e4die Tech."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1007\/s00132-012-1949-0","article-title":"Areas of application of numerical simulation in musculoskeletal research and its importance for orthopaedic surgery","volume":"42","author":"Kluess","year":"2013","journal-title":"Orthop."},{"key":"ref_3","unstructured":"Perry, J., Oster, W., Wiedenh\u00f6fer, B., and Berweck, S. (2003). Gait Analysis. Norm and Pathology of Walking, Urban & Fischer."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1007\/s00508-016-1096-4","article-title":"Gait disorders in adults and the elderly: A clinical guide","volume":"129","author":"Pirker","year":"2017","journal-title":"Vienna Klin Wochenschr"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"3362","DOI":"10.3390\/s140203362","article-title":"Gait analysis methods: An overview of wearable and non-wearable systems, highlighting clinical applications","volume":"14","year":"2014","journal-title":"Sensors"},{"key":"ref_6","unstructured":"Klein, B., and FEM (2012). Fundamentals and Applications of the Finite Element Method in Mechanical Engineering and Vehicle Construction, Springer Vieweg."},{"key":"ref_7","first-page":"52","article-title":"Classification of gait types in stroke to standardize orthotic care","volume":"66","author":"Sabbagh","year":"2015","journal-title":"Orthop. Tech."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1093\/ptj\/67.2.206","article-title":"Interrater reliability of a modified Ashworth scale of muscle spasticity","volume":"67","author":"Bohannon","year":"1987","journal-title":"Phys. Ther."},{"key":"ref_9","unstructured":"Smolenski, U.C., Buchmann, J., Beyer, L., and Harke, G. (2020). Janda. Manual Muscle Function Diagnostics\u2014Theory and Practice, Elsevier."},{"key":"ref_10","first-page":"30","article-title":"Walking orthoses for children with cerebral palsy","volume":"18","author":"Grund","year":"2007","journal-title":"Paediatr"},{"key":"ref_11","unstructured":"Russell, D.J., Rosenbaum, P.L., Avery, L.M., Lane, M., and Heinen, F. (2006). Gross Motor Function Measure Gross Motor Function Classification System, Huber."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1177\/0309364610393062","article-title":"Loads on the uprights of a knee-ankle-foot orthosis","volume":"35","author":"Bernhardt","year":"2011","journal-title":"Prosthet. Orthot. Int."}],"container-title":["Children"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2227-9067\/11\/1\/30\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T21:42:21Z","timestamp":1760132541000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2227-9067\/11\/1\/30"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12,26]]},"references-count":12,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,1]]}},"alternative-id":["children11010030"],"URL":"https:\/\/doi.org\/10.3390\/children11010030","relation":{},"ISSN":["2227-9067"],"issn-type":[{"value":"2227-9067","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,12,26]]}}}