{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,11]],"date-time":"2026-11-11T16:17:10Z","timestamp":1794413830671,"version":"4.9.1"},"reference-count":68,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2025,11,20]],"date-time":"2025-11-20T00:00:00Z","timestamp":1763596800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100004869","name":"Medical Faculty, University of M\u00fcnster, Germany","doi-asserted-by":"publisher","award":["23_1-003"],"award-info":[{"award-number":["23_1-003"]}],"id":[{"id":"10.13039\/501100004869","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Children"],"abstract":"<jats:p>Background: Pediatric thoracic magnetic resonance imaging (MRI) has evolved into a valuable diagnostic modality that offers high-resolution morphological and functional assessment. While conventional radiography and computed tomography (CT) remain standard, their radiation exposure poses significant risks in children requiring repeated imaging. Technological innovations have addressed prior MRI limitations such as low lung proton density and motion artifacts, expanding its role in pediatric thoracic imaging. Methods: A review of the recent literature was performed, focusing on technical advancements, key MRI sequences and clinical applications in pediatric thoracic imaging. Emphasis was placed on ultrashort echo time (UTE), phase-resolved functional lung (PREFUL) MRI, hyperpolarized xenon-129 MRI, radial imaging, compressed sensing, parallel imaging and respiratory gating techniques. Results: Modern MRI sequences provide both detailed anatomic visualization and quantitative functional assessment of the pediatric thorax. UTE and PREFUL enable evaluation of lung parenchyma, ventilation, and perfusion, while hyperpolarized gas imaging offers high-resolution functional mapping. Radial, compressed sensing and parallel imaging reduce motion artifacts and acquisition times, enhancing feasibility in uncooperative children. Clinical indications include assessment of congenital malformations, chronic lung disease like cystic fibrosis, infectious and inflammatory disorders, tumors and selected traumatic injuries. Conclusions: Recent technical advances have established pediatric thoracic MRI as a versatile, patient-friendly alternative, as well as a complementary method to CT in selected clinical scenarios. Ongoing developments in acquisition speed, motion compensation and functional imaging are expected to further improve diagnostic accuracy and clinical utility, supporting broader adoption in routine pediatric thoracic evaluation.<\/jats:p>","DOI":"10.3390\/children12111576","type":"journal-article","created":{"date-parts":[[2025,11,21]],"date-time":"2025-11-21T08:59:46Z","timestamp":1763715586000},"page":"1576","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Pediatric Thoracic MRI: Safer, Sharper and Smarter Diagnostics"],"prefix":"10.3390","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8549-8754","authenticated-orcid":false,"given":"Patricia","family":"Tischendorf","sequence":"first","affiliation":[{"name":"Clinic for Radiology, University Hospital M\u00fcnster, University of M\u00fcnster, Albert-Schweitzer-Campus 1, Building A1, D-48149 M\u00fcnster, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laura","family":"Beck","sequence":"additional","affiliation":[{"name":"Clinic for Radiology, University Hospital M\u00fcnster, University of M\u00fcnster, Albert-Schweitzer-Campus 1, Building A1, D-48149 M\u00fcnster, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5734-9524","authenticated-orcid":false,"given":"Tobias","family":"Kr\u00e4hling","sequence":"additional","affiliation":[{"name":"Clinic for Radiology, University Hospital M\u00fcnster, University of M\u00fcnster, Albert-Schweitzer-Campus 1, Building A1, D-48149 M\u00fcnster, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,11,20]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1016\/S0730-725X(01)00417-9","article-title":"Low field thoracic MRI--A fast and radiation free routine imaging modality in children","volume":"19","author":"Wagner","year":"2001","journal-title":"Magn. Reson. Imaging"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1007\/s13244-012-0176-x","article-title":"MRI of the lung (1\/3): Methods","volume":"3","author":"Wild","year":"2012","journal-title":"Insights Imaging"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1007\/s13244-011-0142-z","article-title":"MRI of the lung (3\/3)-current applications and future perspectives","volume":"3","author":"Biederer","year":"2012","journal-title":"Insights Imaging"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"2297","DOI":"10.1002\/mrm.26891","article-title":"A double echo ultra short echo time (UTE) acquisition for respiratory motion-suppressed high resolution imaging of the lung","volume":"79","author":"Delacoste","year":"2018","journal-title":"Magn. Reson. Med."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"775","DOI":"10.1002\/mrm.30299","article-title":"Comparison of 3D UTE free-breathing lung MRI with hyperpolarized (129)Xe MRI in pediatric cystic fibrosis","volume":"93","author":"Munidasa","year":"2025","journal-title":"Magn. Reson. Med."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"326","DOI":"10.1002\/jmri.22267","article-title":"Ultra-short echo time (UTE) MR imaging of the lung: Comparison between normal and emphysematous lungs in mutant mice","volume":"32","author":"Takahashi","year":"2010","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1491","DOI":"10.1002\/mrm.22521","article-title":"Ultrashort echo time (UTE) MRI of the lung: Assessment of tissue density in the lung parenchyma","volume":"64","author":"Togao","year":"2010","journal-title":"Magn. Reson. Med."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"3416","DOI":"10.1016\/j.acra.2024.01.039","article-title":"Phase-Resolved Functional Lung (PREFUL) MRI to Quantify Ventilation: Feasibility and Physiological Relevance in Severe Asthma","volume":"31","author":"Friedlander","year":"2024","journal-title":"Acad. Radiol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"851","DOI":"10.1002\/jmri.29458","article-title":"Phase-resolved Functional Lung (PREFUL) MRI May Reveal Distinct Pulmonary Perfusion Defects in Postacute COVID-19 Syndrome: Sex, Hospitalization, and Dyspnea Heterogeneity","volume":"61","author":"Ouyang","year":"2025","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Vogel-Claussen, J., Kaireit, T.F., Voskrebenzev, A., Klimes, F., Glandorf, J., Behrendt, L., Gutberlet, M., Korz, C., Speth, M., and Welte, T. (2023). Phase-resolved Functional Lung (PREFUL) MRI-derived Ventilation and Perfusion Parameters Predict Future Lung Transplant Loss. Radiology, 307.","DOI":"10.1148\/radiol.221958"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"708.e9","DOI":"10.1016\/j.crad.2021.05.015","article-title":"Clinical application of ultrashort echo-time MRI for lung pathologies in children","volume":"76","author":"Geiger","year":"2021","journal-title":"Clin. Radiol."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Ringwald, F.G., Wucherpfennig, L., Hagen, N., Mucke, J., Kaletta, S., Eichinger, M., Stahl, M., Triphan, S.M.F., Leutz-Schmidt, P., and Gestewitz, S. (2024). Automated lung segmentation on chest MRI in children with cystic fibrosis. Front. Med., 11.","DOI":"10.3389\/fmed.2024.1401473"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Dournes, G., and Woods, J.C. (2024). Chronic Pediatric Lung Diseases: Counterpoint-A Growing Role for MRI. Am. J. Roentgenol., 224.","DOI":"10.2214\/AJR.24.32405"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1002\/ppul.23328","article-title":"Validating chest MRI to detect and monitor cystic fibrosis lung disease in a pediatric cohort","volume":"51","author":"Tepper","year":"2016","journal-title":"Pediatr. Pulmonol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1040","DOI":"10.1007\/s003300050511","article-title":"Cross-sectional imaging with CT and\/or MRI of pediatric chest tumors","volume":"8","author":"Wyttenbach","year":"1998","journal-title":"Eur. Radiol."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"842","DOI":"10.1007\/s12098-018-02852-w","article-title":"Pediatric Chest MRI: A Review","volume":"86","author":"Kapur","year":"2019","journal-title":"Indian. J. Pediatr."},{"key":"ref_17","first-page":"S73","article-title":"Lung MRI: The future is now","volume":"60","author":"Woods","year":"2024","journal-title":"Pediatr. Pulmonol."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1007\/s13244-011-0146-8","article-title":"MRI of the lung (2\/3). Why ... when ... how?","volume":"3","author":"Biederer","year":"2012","journal-title":"Insights Imaging"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1002\/jmri.20824","article-title":"MRI of the lung: Value of different turbo spin-echo, single-shot turbo spin-echo, and 3D gradient-echo pulse sequences for the detection of pulmonary metastases","volume":"25","author":"Bruegel","year":"2007","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1007\/s00330-001-1147-7","article-title":"Analysis of artefacts and detail resolution of lung MRI with breath-hold T1-weighted gradient-echo and T2-weighted fast spin-echo sequences with respiratory triggering","volume":"12","author":"Biederer","year":"2002","journal-title":"Eur. Radiol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1002\/nbm.706","article-title":"MRI of lung parenchyma in rats and mice using a gradient-echo sequence","volume":"14","author":"Beckmann","year":"2001","journal-title":"NMR Biomed."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1002\/jmri.22600","article-title":"Measuring lung water: Ex vivo validation of multi-image gradient echo MRI","volume":"34","author":"Holverda","year":"2011","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1186\/s40644-023-00531-4","article-title":"Detection of solid and subsolid pulmonary nodules with lung MRI: Performance of UTE, T1 gradient-echo, and single-shot T2 fast spin echo","volume":"23","author":"Sanchez","year":"2023","journal-title":"Cancer Imaging"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"829","DOI":"10.3348\/kjr.2020.0955","article-title":"Imaging Assessment of Visceral Pleural Surface Invasion by Lung Cancer: Comparison of CT and Contrast-Enhanced Radial T1-Weighted Gradient Echo 3-Tesla MRI","volume":"22","author":"Zhang","year":"2021","journal-title":"Korean J. Radiol."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1016\/j.crad.2023.12.005","article-title":"The value of T2-weighted MRI contrast ratio combined with DWI in evaluating the pathological grade of solid lung adenocarcinoma","volume":"79","author":"Dang","year":"2024","journal-title":"Clin. Radiol."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Liu, H., Zheng, L., Shi, G., Xu, Q., Wang, Q., Zhu, H., Feng, H., Wang, L., Zhang, N., and Xue, M. (2021). Pulmonary Functional Imaging for Lung Adenocarcinoma: Combined MRI Assessment Based on IVIM-DWI and OE-UTE-MRI. Front. Oncol., 11.","DOI":"10.3389\/fonc.2021.677942"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"469","DOI":"10.5152\/dir.2021.20344","article-title":"Spin-echo and diffusion-weighted MRI in differentiation between progressive massive fibrosis and lung cancer","volume":"27","author":"Guneyli","year":"2021","journal-title":"Diagn. Interv. Radiol."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"2955","DOI":"10.1007\/s00330-025-11378-7","article-title":"MRI and zero or ultra-short echo-time sequences in secondary interstitial lung diseases: Current applicability and future perspectives","volume":"35","author":"Landini","year":"2025","journal-title":"Eur. Radiol."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1002\/jmri.26644","article-title":"Free-breathing unsedated MRI in children: Justification and techniques","volume":"50","author":"Janos","year":"2019","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1007\/s00247-016-3553-7","article-title":"Free-breathing motion-corrected late-gadolinium-enhancement imaging improves image quality in children","volume":"46","author":"Olivieri","year":"2016","journal-title":"Pediatr. Radiol."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"1696","DOI":"10.1002\/jmri.28165","article-title":"Clinical Feasibility of Structural and Functional MRI in Free-Breathing Neonates and Infants","volume":"55","author":"Zanette","year":"2022","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Tischendorf, P., Kunnemann, M.D., Krahling, T., Lange, J.H., Heindel, W., and Beck, L. (2025). Thoracic MRI in Pediatric Oncology: Feasibility and Image Quality of Post-Contrast Free-Breathing Radial 3D T1 Weighted Imaging. Biomedicines, 13.","DOI":"10.3390\/biomedicines13092302"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1053\/j.sult.2010.01.005","article-title":"State-of-the-art in pediatric body and musculoskeletal magnetic resonance imaging","volume":"31","author":"MacKenzie","year":"2010","journal-title":"Semin. Ultrasound CT MR"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"1279","DOI":"10.1148\/rg.255045202","article-title":"Parallel MR imaging: A user\u2019s guide","volume":"25","author":"Glockner","year":"2005","journal-title":"Radiographics"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1148\/rg.2020190112","article-title":"MRI Techniques to Decrease Imaging Times in Children","volume":"40","author":"Kozak","year":"2020","journal-title":"Radiographics"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"1451","DOI":"10.1148\/rg.295095041","article-title":"MR imaging at 3.0 T in children: Technical differences, safety issues, and initial experience","volume":"29","author":"Chavhan","year":"2009","journal-title":"Radiographics"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"930","DOI":"10.1177\/02841851241259924","article-title":"Comparison of lung lesion assessment using free-breathing dynamic contrast-enhanced 1.5-T MRI with a golden-angle radial stack-of-stars VIBE sequence and CT","volume":"65","author":"Chen","year":"2024","journal-title":"Acta Radiol."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1002\/jmri.21882","article-title":"Half-Fourier-acquisition single-shot turbo spin-echo (HASTE) MRI of the lung at 3 Tesla using parallel imaging with 32-receiver channel technology","volume":"30","author":"Henzler","year":"2009","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"1597","DOI":"10.3348\/kjr.2018.0931","article-title":"Rapid Imaging: Recent Advances in Abdominal MRI for Reducing Acquisition Time and Its Clinical Applications","volume":"20","author":"Yoon","year":"2019","journal-title":"Korean J. Radiol."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"438","DOI":"10.3348\/kjr.2018.0310","article-title":"High Acceleration Three-Dimensional T1-Weighted Dual Echo Dixon Hepatobiliary Phase Imaging Using Compressed Sensing-Sensitivity Encoding: Comparison of Image Quality and Solid Lesion Detectability with the Standard T1-Weighted Sequence","volume":"20","author":"Nam","year":"2019","journal-title":"Korean J. Radiol."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"966","DOI":"10.1002\/jmri.25547","article-title":"Compressed sensing for body MRI","volume":"45","author":"Feng","year":"2017","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1097\/RLI.0000000000000179","article-title":"Respiratory Motion-Resolved Compressed Sensing Reconstruction of Free-Breathing Radial Acquisition for Dynamic Liver Magnetic Resonance Imaging","volume":"50","author":"Chandarana","year":"2015","journal-title":"Investig. Radiol."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"1635","DOI":"10.1007\/s00247-015-3384-y","article-title":"Clinical performance of a free-breathing spatiotemporally accelerated 3-D time-resolved contrast-enhanced pediatric abdominal MR angiography","volume":"45","author":"Zhang","year":"2015","journal-title":"Pediatr. Radiol."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"1154","DOI":"10.2214\/AJR.07.3657","article-title":"MRI artifact reduction and quality improvement in the upper abdomen with PROPELLER and prospective acquisition correction (PACE) technique","volume":"191","author":"Hirokawa","year":"2008","journal-title":"Am. J. Roentgenol."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1002\/jmri.25977","article-title":"Free-breathing dynamic contrast-enhanced MRI for assessment of pulmonary lesions using golden-angle radial sparse parallel imaging","volume":"48","author":"Chen","year":"2018","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"2557","DOI":"10.1016\/j.acra.2023.01.029","article-title":"Impact of Radial Percentage K-Space Filling and Signal Averaging on Native Lung MRI Image Quality in 3D Radial UTE Acquisition: A Pilot Study","volume":"30","author":"Sodhi","year":"2023","journal-title":"Acad. Radiol."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"840","DOI":"10.1007\/s00247-014-3244-1","article-title":"Improved abdominal MRI in non-breath-holding children using a radial k-space sampling technique","volume":"45","author":"Lee","year":"2015","journal-title":"Pediatr. Radiol."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"1326","DOI":"10.1007\/s00247-022-05298-7","article-title":"Free-breathing magnetic resonance imaging with radial k-space sampling for neonates and infants to reduce anesthesia","volume":"52","author":"Browne","year":"2022","journal-title":"Pediatr. Radiol."},{"key":"ref_49","first-page":"2216","article-title":"Feasibility, Repeatability, and Correlation to Lung Function of Phase-Resolved Functional Lung (PREFUL) MRI-derived Pulmonary Artery Pulse Wave Velocity Measurements","volume":"60","author":"Wernz","year":"2024","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"1363","DOI":"10.1002\/jmri.27737","article-title":"Xenon MRI for Future Assessment of Lung Function and Treatment Response: A Commentary","volume":"54","author":"Wild","year":"2021","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"e241596","DOI":"10.1148\/radiol.241596","article-title":"Phase-resolved Functional Lung MRI Reveals Distinct Lung Perfusion Phenotype in Children and Adolescents with Post-COVID-19 Condition","volume":"314","author":"Voskrebenzev","year":"2025","journal-title":"Radiology"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1007\/s00247-021-05018-7","article-title":"Magnetic resonance imaging for congenital lung malformations","volume":"52","author":"Newman","year":"2022","journal-title":"Pediatr. Radiol."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"1083","DOI":"10.1007\/s00247-020-04658-5","article-title":"Structural and perfusion magnetic resonance imaging of congenital lung malformations","volume":"50","author":"Kellenberger","year":"2020","journal-title":"Pediatr. Radiol."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"4544","DOI":"10.1007\/s00330-019-06042-w","article-title":"Agreement between magnetic resonance imaging and computed tomography in the postnatal evaluation of congenital lung malformations: A pilot study","volume":"29","author":"Zirpoli","year":"2019","journal-title":"Eur. Radiol."},{"key":"ref_55","doi-asserted-by":"crossref","unstructured":"Willers, C.C., Frauchiger, B.S., Stranzinger, E., Bauman, G., Moeller, A., Jung, A., Hector, A., Regamey, N., Zanolari, M., and Mueller-Suter, D. (2022). Feasibility of unsedated lung MRI in young children with cystic fibrosis. Eur. Respir. J., 60.","DOI":"10.1183\/13993003.03112-2021"},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1016\/j.jcf.2013.09.003","article-title":"HRCT and MRI of the lung in children with cystic fibrosis: Comparison of different scoring systems","volume":"13","author":"Sileo","year":"2014","journal-title":"J. Cyst. Fibros."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"2048","DOI":"10.1002\/mrm.29566","article-title":"Inter- and intravisit repeatability of free-breathing MRI in pediatric cystic fibrosis lung disease","volume":"89","author":"Munidasa","year":"2023","journal-title":"Magn. Reson. Med."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"518","DOI":"10.1016\/j.jcf.2018.05.003","article-title":"Multicentre standardisation of chest MRI as radiation-free outcome measure of lung disease in young children with cystic fibrosis","volume":"17","author":"Wielputz","year":"2018","journal-title":"J. Cyst. Fibros."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"898","DOI":"10.1007\/s10875-022-01247-z","article-title":"Lung MRI- Changing Paradigms in Evaluation of Chronic Granulomatous Disease in Children","volume":"42","author":"Sodhi","year":"2022","journal-title":"J. Clin. Immunol."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"1196","DOI":"10.1002\/jmri.25082","article-title":"Rapid lung MRI in children with pulmonary infections: Time to change our diagnostic algorithms","volume":"43","author":"Sodhi","year":"2016","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"70","DOI":"10.3109\/10428194.2015.1041389","article-title":"Rapid lung MRI-paradigm shift in evaluation of febrile neutropenia in children with leukemia: A pilot study","volume":"57","author":"Sodhi","year":"2016","journal-title":"Leuk. Lymphoma"},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"2752","DOI":"10.1007\/s00330-002-1404-4","article-title":"Steady-state free precession projection MRI as a potential alternative to the conventional chest X-ray in pediatric patients with suspected pneumonia","volume":"12","author":"Rupprecht","year":"2002","journal-title":"Eur. Radiol."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1016\/j.acra.2017.09.013","article-title":"Diagnostic Utility of 3T Lung MRI in Children with Interstitial Lung Disease: A Prospective Pilot Study","volume":"25","author":"Sodhi","year":"2018","journal-title":"Acad. Radiol."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"1204","DOI":"10.1007\/s00117-014-2738-z","article-title":"[MRI of interstitial lung diseases: What is possible?]","volume":"54","author":"Biederer","year":"2014","journal-title":"Radiologe"},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/j.rmed.2019.07.006","article-title":"Magnetic resonance imaging of interstitial lung diseases: A state-of-the-art review","volume":"155","author":"Lonzetti","year":"2019","journal-title":"Respir. Med."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1148\/rg.2019180078","article-title":"Connective Tissue Disorders in Childhood: Are They All the Same?","volume":"39","author":"Navallas","year":"2019","journal-title":"Radiographics"},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"850","DOI":"10.1007\/s11547-017-0783-1","article-title":"Diagnostic Imaging in pediatric thoracic trauma","volume":"122","author":"Piccolo","year":"2017","journal-title":"Radiol. Med."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1016\/j.jcf.2018.10.003","article-title":"Ventilation and perfusion assessed by functional MRI in children with CF: Reproducibility in comparison to lung function","volume":"18","author":"Nyilas","year":"2019","journal-title":"J. Cyst. Fibros."}],"container-title":["Children"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2227-9067\/12\/11\/1576\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,21]],"date-time":"2025-11-21T09:37:11Z","timestamp":1763717831000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2227-9067\/12\/11\/1576"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,20]]},"references-count":68,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2025,11]]}},"alternative-id":["children12111576"],"URL":"https:\/\/doi.org\/10.3390\/children12111576","relation":{},"ISSN":["2227-9067"],"issn-type":[{"value":"2227-9067","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,20]]}}}