{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T01:29:37Z","timestamp":1760059777003,"version":"build-2065373602"},"reference-count":124,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2025,7,15]],"date-time":"2025-07-15T00:00:00Z","timestamp":1752537600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["CMTR"],"abstract":"<jats:p>Study design: Trends in the utilization of Mandibulo-Maxillary Fixation (MMF) are shifting nowadays from tooth-borne devices over specialized screws to hybrid MMF devices. Hybrid MMF devices come in self-made Erich arch bar modifications and commercial hybrid MMF systems (CHMMFSs). Objective: We survey the available technical\/clinical data. Hypothetically, the risk of tooth root damage by transalveolar screws is diminished by a targeting function of the screw holes\/slots. Methods: We utilize a literature review and graphic displays to disclose parallels and dissimilarities in design and functionality with an in-depth look at the targeting properties. Results: Self-made hybrid arch bars have limitations to meet low-risk interradicular screw insertion sites. Technical\/clinical information on CHMMFSs is unevenly distributed in favor of the SMARTLock System: positive outcome variables are increased speed of application\/removal, the possibility to eliminate wiring and stick injuries and screw fixation with standoff of the embodiment along the attached gingiva. Inferred from the SMARTLock System, all four CHMMFs possess potential to effectively prevent tooth root injuries but are subject to their design features and targeting with the screw-receiving holes. The height profile and geometry shape of a CHMMFS may restrict three-dimensional spatial orientation and reach during placement. To bridge between interradicular spaces and tooth equators, where hooks or tie-up-cleats for intermaxillary cerclages should be ideally positioned under biomechanical aspects, can be problematic. The movability of their screw-receiving holes according to all six degrees of freedom differs. Conclusion: CHMMFSs allow simple immobilization of facial fractures involving dental occlusion. The performance in avoiding tooth root damage is a matter of design subtleties.<\/jats:p>","DOI":"10.3390\/cmtr18030033","type":"journal-article","created":{"date-parts":[[2025,7,15]],"date-time":"2025-07-15T08:04:41Z","timestamp":1752566681000},"page":"33","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Matrix WaveTM System for Mandibulo-Maxillary Fixation\u2014Just Another Variation on the MMF Theme?\u2014Part II: In Context to Self-Made Hybrid Erich Arch Bars and Commercial Hybrid MMF Systems\u2014Literature Review and Analysis of Design Features"],"prefix":"10.3390","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5091-8774","authenticated-orcid":false,"given":"Carl-Peter","family":"Cornelius","sequence":"first","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Facial Plastic Surgery, Ludwig-Maximilians University Munich, 80337 Munich, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6109-638X","authenticated-orcid":false,"given":"Paris Georgios","family":"Liokatis","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Facial Plastic Surgery, Ludwig-Maximilians University Munich, 80337 Munich, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Timothy","family":"Doerr","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology, University of Rochester Medical Center, Rochester, NY 14642, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Damir","family":"Matic","sequence":"additional","affiliation":[{"name":"London Plastic Surgery Centre, 123 Dundas St, London, ON N6A 1E8, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5861-5046","authenticated-orcid":false,"given":"Stefano","family":"Fusetti","sequence":"additional","affiliation":[{"name":"Department of Maxillofacial Surgery, University of Padova Medical Center, 35122 Padova, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Rasse","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Center of Reconstructive Surgery, University Hospital, Paracelsus Medical University, 5020 Salzburg, Austria"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8800-4596","authenticated-orcid":false,"given":"Nils Claudius","family":"Gellrich","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Hannover Medical School, 30625 Hannover, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4987-2913","authenticated-orcid":false,"given":"Max","family":"Heiland","sequence":"additional","affiliation":[{"name":"Charit\u00e9\u2014Universit\u00e4tsmedizin Berlin, Corporate Member of Freie Universit\u00e4t Berlin and Humboldt-Universit\u00e4t zu Berlin, 13353 Berlin, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Warren","family":"Schubert","sequence":"additional","affiliation":[{"name":"Division of Plastic Surgery, University of Minnesota, Minneapolis, MN 55455, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel","family":"Buchbinder","sequence":"additional","affiliation":[{"name":"Division of Oral and Maxillofacial Surgery, Department of Otolaryngology, Icahn School of Medicine at Mount Sinai, Mount Sinai Beth Israel, New York, NY 10003, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2025,7,15]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Cornelius, C.P., Liokatis, P.G., Doerr, T., Matic, D., Fusetti, S., Rasse, M., Gellrich, N.C., Heiland, M., and Buchbinder, D. (2025). Matrix WaveTM System for mandibulo-maxillary fixation\u2014Just another variation on the MMF theme ?\u2014Part I: A review on the provenance, evolution and properties of the system. Preprints.","DOI":"10.3390\/cmtr18030032"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1007\/s002380050073","article-title":"Maxillomandibular fixation with a combination of arch bars and screws","volume":"21","author":"Tellioglu","year":"1998","journal-title":"Eur. J. Plast. Surg."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Gibbons, A.J., Evans, M.J., Abdullakutty, A., and Grew, N.R. (2005). Interesting case: Arch bar support using self-drilling intermaxillary fixation screws. Br. J. Oral Maxillofac. Surg., 43.","DOI":"10.1016\/j.bjoms.2004.06.023"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1016\/j.ijom.2012.11.003","article-title":"Modification of arch bars used for intermaxillary fixation in oral and maxillofacial surgery","volume":"42","year":"2013","journal-title":"Int. J. Oral Maxillofac. Surg."},{"key":"ref_5","first-page":"368","article-title":"A simple maneuvre for promising results\u2014Opening the winglets of an arch bar for placement of screws: A Technical note","volume":"4","author":"Suresh","year":"2015","journal-title":"GJRA Glob. J. Res. Anal."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"134","DOI":"10.4103\/njms.NJMS_16_18","article-title":"Evaluation of efficacy of intermaxillary fixation screws versus modified arch bar for intermaxillary fixation","volume":"9","author":"Rothe","year":"2018","journal-title":"Natl. J. Maxillofac. Surg."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1007\/s12663-018-1110-7","article-title":"Comparative evaluation of efficacy of conventional arch bar, intermaxillary fixation screws, and modified arch bar for intermaxillary fixation","volume":"18","author":"Rothe","year":"2019","journal-title":"J. Maxillofac. Oral Surg."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1007\/s10006-019-00766-1","article-title":"A prospective comparative clinical study on modified screw retained arch bar (SRAB) and conventional Erich\u2019s arch bar (CEAB)","volume":"23","author":"Pathak","year":"2019","journal-title":"Oral Maxillofac. Surg."},{"key":"ref_9","first-page":"41","article-title":"Comparative evaluation of modified Erich\u2019s arch bar, conventional Erich\u2019s arch bar and intermaxillary fixation screws in maxillo-mandibular fixation: A prospective clinical study","volume":"4","author":"Hassan","year":"2018","journal-title":"Int. J. Med. Res. Res. Prof."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"287","DOI":"10.4103\/ams.ams_20_20","article-title":"A comparative randomized prospective clinical study on modified Erich arch bar with conventional Erich arch bar for maxillomandibular fixation","volume":"10","author":"Venugopalan","year":"2020","journal-title":"Ann. Maxillofac. Surg."},{"key":"ref_11","first-page":"928","article-title":"Comparison of clinical efficacy of screw-retained arch bar vs conventional Erich\u2019s arch bar in maxillomandibular fixation: A randomized clinical trial","volume":"24","author":"Elhadidi","year":"2023","journal-title":"J. Contemp. Dent. Pract."},{"key":"ref_12","unstructured":"Kohler, K., Pinto, J., Johnston, T.S., and Papay, F.A. (2019). Maxillo-mandibular, Fixation, Devices. (No. U.S. 10,470,806 B2), Patent."},{"key":"ref_13","unstructured":"Marcus, J.R. (2012). Intermaxillary Fixation Device and Method of Using Same. (No. U.S. 8,118,850 B2), Patent."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"948e","DOI":"10.1097\/PRS.0000000000002727","article-title":"Stryker SMARTLock Hybrid Maxillomandibular Fixation System: Clinical application, complications, and radiographic findings","volume":"138","author":"Marcus","year":"2016","journal-title":"Plast Reconstr. Surg."},{"key":"ref_15","first-page":"1","article-title":"Use of hybrid MMF in oral and maxillofacial surgery: A retrospective review","volume":"3","author":"Nizam","year":"2014","journal-title":"J. Maxillofac. Trauma"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1016\/j.joms.2014.08.025","article-title":"Bone-supported arch bars are associated with comparable outcomes to Erich arch bars in the treatment of mandibular fractures with intermaxillary fixation","volume":"73","author":"Chao","year":"2015","journal-title":"J. Oral Maxillofac. Surg."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"142e","DOI":"10.1097\/PRS.0000000000001920","article-title":"Stryker SMARTLock Hybrid Maxillomandibular Fixation System: Clinical application, complications, and radiographic findings","volume":"137","author":"Kendrick","year":"2016","journal-title":"Plast. Reconstr. Surg."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"949e","DOI":"10.1097\/PRS.0000000000002730","article-title":"Reply: Stryker SMARTLock Hybrid Maxillomandibular Fixation System: Clinical application, complications, and radiographic findings","volume":"138","author":"Kendrick","year":"2016","journal-title":"Plast. Reconstr. Surg."},{"key":"ref_19","first-page":"69848","article-title":"Bone supported arch bar versus Erich arch bar for intermaxillary fixation: A comparative clinical study in maxillofacial fractures","volume":"10","author":"Rani","year":"2018","journal-title":"Int. J. Curr. Res."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"2592","DOI":"10.1016\/j.joms.2018.06.172","article-title":"Publication: Does the use of hybrid arch bars for the treatment of mandibular fractures reduce the length of surgery?","volume":"76","author":"Bouloux","year":"2018","journal-title":"J. Oral Maxillofac. Surg."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.joms.2019.01.030","article-title":"Hybrid arch bars reduce placement time and glove perforations compared with Erich arch bars during the application of intermaxillary fixation: A randomized controlled trial","volume":"77","author":"King","year":"2019","journal-title":"J. Oral Maxillofac. Surg."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1055\/s-0038-1639351","article-title":"The hybrid arch bar is a cost-beneficial alternative in the open treatment of mandibular fractures","volume":"12","author":"Khelemsky","year":"2019","journal-title":"Craniomaxillofac. Trauma Reconstr."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1177\/19433875221080019","article-title":"Comparison of efficacy and safety of hybrid arch bar with Erich arch bar in the management of mandibular fractures: A randomized clinical trial","volume":"16","author":"Sankar","year":"2023","journal-title":"Craniomaxillofac. Trauma Reconstr."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"332","DOI":"10.5125\/jkaoms.2023.49.6.332","article-title":"Comparison of hybrid arch bar versus conventional arch bar for temporary maxillomandibular fixation during treatment of jaw fractures: A prospective comparative study","volume":"49","author":"Burman","year":"2023","journal-title":"J. Korean Assoc. Oral Maxillofac. Surg."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"S35","DOI":"10.1097\/SAP.0000000000001497","article-title":"Is the SMARTLock Hybrid Maxillomandibular Fixation System comparable to intermaxillary fixation screws in closed reduction of condylar fractures?","volume":"81","author":"Roeder","year":"2018","journal-title":"Ann. Plast. Surg."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"640","DOI":"10.1016\/j.oooo.2020.07.015","article-title":"A randomized prospective comparison of maxillomandibular fixation (MMF) techniques: \u201cSMARTLock\u201d hybrid MMF versus MMF screws","volume":"130","author":"Caccamese","year":"2020","journal-title":"Oral Surg. Oral Med. Oral Pathol. Oral Radiol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"536","DOI":"10.1001\/jamaoto.2019.0183","article-title":"A clinical comparison and economic evaluation of Erich arch bars, 4-point fixation, and bone-supported arch bars for maxillomandibular fixation","volume":"145","author":"Edmunds","year":"2019","journal-title":"JAMA Otolaryngol. Head Neck Surg."},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Salavadi, R.K., Sowmya, J., Mani Kumari, B., Kamath, K.P., Anand, P.S., Kumar, N.M.R., and Jadhav, P. (2025). Comparison of the efficacy of Erich arch bars, IMF screws and SMART Lock Hybrid arch bars in the management of mandibular fractures\u2014A Randomized clinical study. J. Stomatol. Oral Maxillofac. Surg.","DOI":"10.1016\/j.jormas.2025.102217"},{"key":"ref_29","unstructured":"Wilt, D., Kim, C., and StJohn, D. (2019, January 7\u20139). Do hybrid arch bars pose a risk to the dentition?. Proceedings of the American College of Oral and Maxillofacial Surgeons\u201440th Annual Scientififc Conference and Exhibition, Santa Fe, NM, USA."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Carlson, A.R., Shammas, R.L., Allori, A.C., and Powers, D.B. (2017). A technique for reduction of edentulous fractures using dentures and SMARTLock Hybrid Fixation System. Plast. Reconstr. Surg. Glob. Open, 5.","DOI":"10.1097\/GOX.0000000000001473"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"858","DOI":"10.1016\/j.bjoms.2021.01.004","article-title":"What is a better modality of maxillomandibular fixation: Bone-supported arch bars or Erich arch bars? A systematic review and meta-analysis","volume":"59","author":"Jain","year":"2021","journal-title":"Br. J. Oral Maxillofac. Surg."},{"key":"ref_32","first-page":"435","article-title":"Treatment outcome comparison between tooth borne vs bone borne intermaxillary fixation devices-a systematic review","volume":"17","author":"Sulistyani","year":"2024","journal-title":"J. Int. Dent. Med. Res."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"247","DOI":"10.4103\/ams.ams_35_21","article-title":"The use of screw retained hybrid arch bar for maxillomandibular fixation in the treatment of mandibular fractures: A comparative study","volume":"11","author":"Hamid","year":"2021","journal-title":"Ann. Maxillofac. Surg."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1016\/j.bjps.2024.02.075","article-title":"Patient outcomes and complications following various maxillomandibular fixation techniques: A systematic review and meta-analysis","volume":"92","author":"Kalluri","year":"2024","journal-title":"J. Plast. Reconstr. Aesthetic Surg."},{"key":"ref_35","unstructured":"Ghobadi, S., Garcia, S.R., Hausman, A., Robinson, S., Billard, M., and Luby, R.N. (2015). Contourable Plate. (No. 0,297,272 A1), U.S. Patent."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1177\/0003134820960018","article-title":"Comparison of Biomet Omnimax(\u00a9) versus traditional arch bar placement in trauma patients with facial fractures","volume":"88","author":"Aukerman","year":"2022","journal-title":"Am. Surg."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"e79","DOI":"10.1016\/j.joms.2018.06.166","article-title":"The Omnimax MMF System: A cohort study for clinical evaluation. Preliminary results of an ongoing study","volume":"76","author":"Morio","year":"2018","journal-title":"J. Oral Maxillofac. Surg."},{"key":"ref_38","unstructured":"Woodburn, W.N., Griffith, W., Barber, J.R., and Parranto, G. (2018). Flexible Maxillo-Mandibular Fixation Device. (No. 982,077 B2), U.S. Patent."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/j.jobcr.2017.08.006","article-title":"The use of Synthes MatrixWAVE bone anchored arch bars for closed treatment of multiple concurrent mandibular fractures","volume":"7","author":"Kiwanuka","year":"2017","journal-title":"J. Oral Biol. Craniofac. Res."},{"key":"ref_40","unstructured":"Frigg, R., Richter, J., Leuenberger, S., Cornelius, C.P., and Hamel, R.J. (2018). Flexible Maxillo-Mandibular Fixation Device. (No. US 10,130,404 B2), Patent."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1111\/j.1600-0765.1981.tb00997.x","article-title":"Continuous widening of the band of attached gingiva from 23 to 65 years of age","volume":"16","author":"Ainamo","year":"1981","journal-title":"J. Periodontal Res."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1007\/s00784-021-04053-w","article-title":"Width and thickness of the gingiva in periodontally healthy individuals in a central Indian population: A cross-sectional study","volume":"26","author":"Anand","year":"2022","journal-title":"Clin. Oral Investig."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1902\/jop.1966.37.1.5","article-title":"Anatomical characteristics of gingiva. A clinical and microscopic study of the free and attached gingiva","volume":"37","author":"Ainamo","year":"1966","journal-title":"J. Periodontol."},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Jennes, M.E., Sachse, C., Flugge, T., Preissner, S., Heiland, M., and Nahles, S. (2021). Gender- and age-related differences in the width of attached gingiva and clinical crown length in anterior teeth. BMC Oral Health, 21.","DOI":"10.1186\/s12903-021-01639-4"},{"key":"ref_45","doi-asserted-by":"crossref","unstructured":"Vlachodimou, E., Fragkioudakis, I., and Vouros, I. (2021). Is There an Association between the Gingival Phenotype and the Width of Keratinized Gingiva? A Systematic Review. Dent. J., 9.","DOI":"10.3390\/dj9030034"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/S1010-5182(03)00022-2","article-title":"Comparative assessment of two methods used for interdental immobilization","volume":"31","author":"Ayoub","year":"2003","journal-title":"J. Craniomaxillofac. Surg."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1016\/j.bjoms.2010.04.010","article-title":"Incidence and patterns of needlestick injuries during intermaxillary fixation","volume":"49","author":"Bali","year":"2011","journal-title":"Br. J. Oral Maxillofac. Surg."},{"key":"ref_48","first-page":"823","article-title":"Surgical Glove Perforation and Percutaneous Injury during Intermaxillary Fixation with 0.5 Mm Stainless Steel Wire","volume":"39","author":"Osodin","year":"2022","journal-title":"West Afr. J. Med."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1016\/j.bjoms.2014.12.003","article-title":"Blunt wires in oral and maxillofacial surgery","volume":"53","author":"Brandtner","year":"2015","journal-title":"Br. J. Oral Maxillofac. Surg."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1001\/jamafacial.2014.543","article-title":"Postoperative maxillomandibular fixation after open reduction of mandible fractures","volume":"16","author":"Saman","year":"2014","journal-title":"JAMA Facial Plast. Surg."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"1457","DOI":"10.1097\/SCS.0000000000002737","article-title":"Analysis of fractured mandible over two decades","volume":"27","author":"Oruc","year":"2016","journal-title":"J. Craniofac. Surg."},{"key":"ref_52","first-page":"133","article-title":"The effects of mandibular immobilization on the masticatory system. A review","volume":"16","author":"Ellis","year":"1989","journal-title":"Clin. Plast. Surg."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"642","DOI":"10.1053\/joms.2002.33110","article-title":"Use of a 2.0-mm locking plate\/screw system for mandibular fracture surgery","volume":"60","author":"Ellis","year":"2002","journal-title":"J. Oral Maxillofac. Surg."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"1781","DOI":"10.1016\/j.joms.2020.05.012","article-title":"Combination of rigid and nonrigid fixation versus nonrigid fixation for bilateral mandibular fractures: A multicenter randomized controlled trial","volume":"78","author":"Rughubar","year":"2020","journal-title":"J. Oral Maxillofac. Surg."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"930","DOI":"10.1097\/SCS.0000000000004368","article-title":"Utility of postoperative mandibulomaxillary fixation after rigid internal fixation of isolated mandibular fractures","volume":"29","author":"Diaconu","year":"2018","journal-title":"J. Craniofac. Surg."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1007\/s10006-010-0229-6","article-title":"Supplemental maxillomandibular fixation with miniplate osteosynthesis-required or not?","volume":"15","author":"Kumar","year":"2011","journal-title":"Oral Maxillofac. Surg."},{"key":"ref_57","doi-asserted-by":"crossref","unstructured":"Roccia, F., Sobrero, F., Raveggi, E., Rabufetti, A., Scolozzi, P., Dubron, K., Politis, C., Ganasouli, D., Zanakis, S.N., and Jelovac, D. (2023). European multicenter prospective analysis of the use of maxillomandibular fixation for mandibular fractures treated with open reduction and internal fixation. J Stomatol Oral Maxillofac Surg., 124.","DOI":"10.1016\/j.jormas.2022.101376"},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"141","DOI":"10.4103\/0975-5950.94468","article-title":"A questionnaire survey on postoperative intermaxillary fixation in mandibular trauma: Is its use based on evidence?","volume":"2","author":"Shenoy","year":"2011","journal-title":"Natl. J. Maxillofac. Surg."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"625","DOI":"10.1016\/j.ajodo.2007.01.031","article-title":"Bicortical vs monocortical orthodontic skeletal anchorage","volume":"134","author":"Brettin","year":"2008","journal-title":"Am. J. Orthod. Dentofac. Orthop."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"725","DOI":"10.1016\/j.ajodo.2015.02.018","article-title":"Quantitative evaluation of maxillary interradicular bone with cone-beam computed tomography for bicortical placement of orthodontic mini-implants","volume":"147","author":"Yang","year":"2015","journal-title":"Am. J. Orthod. Dentofac. Orthop."},{"key":"ref_61","doi-asserted-by":"crossref","unstructured":"Haddad, R., and Saadeh, M. (2019). Distance to alveolar crestal bone: A critical factor in the success of orthodontic mini-implants. Prog. Orthod., 20.","DOI":"10.1186\/s40510-019-0273-1"},{"key":"ref_62","doi-asserted-by":"crossref","unstructured":"Pan, F., Kau, C.H., Zhou, H., and Souccar, N. (2013). The anatomical evaluation of the dental arches using cone beam computed tomography--an investigation of the availability of bone for placement of mini-screws. Head. Face Med., 9.","DOI":"10.1186\/1746-160X-9-13"},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"486","DOI":"10.1016\/j.ajodo.2007.05.019","article-title":"Computed tomographic analysis of tooth-bearing alveolar bone for orthodontic miniscrew placement","volume":"135","author":"Lee","year":"2009","journal-title":"Am. J. Orthod. Dentofac. Orthop."},{"key":"ref_64","first-page":"100","article-title":"A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage","volume":"19","author":"Cheng","year":"2004","journal-title":"Int. J. Oral. Maxillofac. Implants"},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"3523","DOI":"10.1007\/s00784-021-04321-9","article-title":"Analysis of biological and structural factors implicated in the clinical success of orthodontic miniscrews at posterior maxillary interradicular sites","volume":"26","author":"Palone","year":"2022","journal-title":"Clin. Oral Investig."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"e192","DOI":"10.1016\/j.ajodo.2022.07.013","article-title":"Miniscrews for orthodontic anchorage: Analysis of risk factors correlated with the progressive susceptibility to failure","volume":"162","author":"Xin","year":"2022","journal-title":"Am. J. Orthod. Dentofac. Orthop."},{"key":"ref_67","first-page":"191","article-title":"\u201cSafe zones\u201d: A guide for miniscrew positioning in the maxillary and mandibular arch","volume":"76","author":"Poggio","year":"2006","journal-title":"Angle Orthod."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"e223","DOI":"10.1016\/j.ajodo.2021.10.006","article-title":"Variability associated with mandibular ramus area thickness and depth in subjects with different growth patterns, gender, and growth status","volume":"161","author":"Mehta","year":"2022","journal-title":"Am. J. Orthod. Dentofac. Orthop."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"721.e7","DOI":"10.1016\/j.ajodo.2006.02.026","article-title":"Quantitative evaluation of cortical bone thickness with computed tomographic scanning for orthodontic implants","volume":"129","author":"Deguchi","year":"2006","journal-title":"Am. J. Orthod. Dentofac. Orthop."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"314.e1","DOI":"10.1016\/j.ajodo.2009.01.023","article-title":"Three-dimensional evaluation of interradicular spaces and cortical bone thickness for the placement and initial stability of microimplants in adults","volume":"136","author":"Park","year":"2009","journal-title":"Am. J. Orthod. Dentofac. Orthop."},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"232","DOI":"10.2334\/josnusd.21-0536","article-title":"Effects of root contact length on the failure rate of anchor screw","volume":"64","author":"Ikenaka","year":"2022","journal-title":"J. Oral Sci."},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"e494","DOI":"10.4317\/medoral.20448","article-title":"Is the Erich arch bar the best intermaxillary fixation method in maxillofacial fractures? A systematic review","volume":"20","author":"Falci","year":"2015","journal-title":"Med. Oral Patol. Oral Cir. Bucal."},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"S68","DOI":"10.1016\/j.ajodo.2006.06.017","article-title":"Root proximity is a major factor for screw failure in orthodontic anchorage","volume":"131","author":"Kuroda","year":"2007","journal-title":"Am. J. Orthod. Dentofac. Orthop."},{"key":"ref_74","doi-asserted-by":"crossref","first-page":"252.e1","DOI":"10.1016\/j.ajodo.2010.01.027","article-title":"Anatomic variability in alveolar sites for skeletal anchorage","volume":"138","author":"Martinelli","year":"2010","journal-title":"Am. J. Orthod. Dentofac. Orthop."},{"key":"ref_75","first-page":"33","article-title":"Co-axial computed tomography for optimizing orthodontic miniscrew implant size and site of placement","volume":"24","author":"Bhalla","year":"2013","journal-title":"Int. J. Orthod. Milwaukee"},{"key":"ref_76","doi-asserted-by":"crossref","first-page":"e669","DOI":"10.4317\/jced.59384","article-title":"Two-dimensional radiographs versus cone-beam computed tomography in planning mini-implant placement: A systematic review","volume":"14","author":"Caetano","year":"2022","journal-title":"J. Clin. Exp. Dent."},{"key":"ref_77","doi-asserted-by":"crossref","first-page":"611","DOI":"10.2319\/100318-713.1","article-title":"Root proximity of miniscrews at a variety of maxillary and mandibular buccal sites: Reliability of panoramic radiography","volume":"89","author":"An","year":"2019","journal-title":"Angle Orthod."},{"key":"ref_78","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1111\/j.1600-0501.2005.01146.x","article-title":"Root repair after injury from mini-screw","volume":"16","author":"Asscherickx","year":"2005","journal-title":"Clin. Oral Implants Res."},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1016\/j.ajodo.2008.06.023","article-title":"Healing of the roots and surrounding structures after intentional damage with miniscrew implants","volume":"135","author":"Brisceno","year":"2009","journal-title":"Am. J. Orthod. Dentofac. Orthop."},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"2440","DOI":"10.1016\/j.joms.2009.04.138","article-title":"Cementum, pulp, periodontal ligament, and bone response after direct injury with orthodontic anchorage screws: A histomorphologic study in an animal model","volume":"67","author":"Dao","year":"2009","journal-title":"J. Oral Maxillofac. Surg."},{"key":"ref_81","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/j.jcms.2005.02.005","article-title":"An audit of mandibular fractures treated by intermaxillary fixation using intraoral cortical bone screws","volume":"33","author":"Roccia","year":"2005","journal-title":"J. Craniomaxillofac. Surg."},{"key":"ref_82","doi-asserted-by":"crossref","first-page":"3015","DOI":"10.1016\/j.joms.2010.12.015","article-title":"Are maxillomandibular fixation screws a better option than Erich arch bars in achieving maxillomandibular fixation? A randomized clinical study","volume":"69","author":"Rai","year":"2011","journal-title":"J. Oral Maxillofac. Surg."},{"key":"ref_83","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1016\/j.joms.2013.08.001","article-title":"Treatment outcomes with the use of maxillomandibular fixation screws in the management of mandible fractures","volume":"72","author":"West","year":"2014","journal-title":"J. Oral Maxillofac. Surg."},{"key":"ref_84","unstructured":"Spiessl, B. (1989). Application of the tension band principle in the Mandible, Tension band plate Part I, Basic principles, 4.1.2.1\u20134.1.2.4. Internal Fixation of the Mandible\u2014A Manual of AO\/ASIF Principles, Springer."},{"key":"ref_85","doi-asserted-by":"crossref","unstructured":"Yaremchuk, M.J., Gruss, J., and Manson, P.N. (1992). Rigid internal fixation of mandibular fractures. Rigid Fixation of the Craniomaxillofacial Skeleton, Butterworth-Heinemann. Chapter 14.","DOI":"10.1097\/00006534-199307000-00030"},{"key":"ref_86","doi-asserted-by":"crossref","unstructured":"Holmes, S., and Hutchison, I. (2000). Caution in use of bicortical intermaxillary fixation screws. Br. J. Oral Maxillofac. Surg., 38.","DOI":"10.1054\/bjom.2000.0514"},{"key":"ref_87","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1054\/bjom.2001.0625","article-title":"Intermaxillary fixation screws and tooth damage","volume":"40","author":"Farr","year":"2002","journal-title":"Br. J. Oral Maxillofac. Surg."},{"key":"ref_88","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1054\/bjom.2001.0771","article-title":"Complications with intermaxillary fixation screws in the management of fractured mandibles","volume":"40","author":"Coburn","year":"2002","journal-title":"Br. J. Oral Maxillofac. Surg."},{"key":"ref_89","first-page":"433","article-title":"The Periotest method","volume":"42","author":"Schulte","year":"1992","journal-title":"Int. Dent. J."},{"key":"ref_90","first-page":"23","article-title":"Periotest to monitor osseointegration and to check the occlusion in oral implantology","volume":"19","author":"Schulte","year":"1993","journal-title":"J. Oral Implantol."},{"key":"ref_91","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1016\/j.ajodo.2017.01.026","article-title":"Insertion torque and Periotest values are important factors predicting outcome after orthodontic miniscrew placement","volume":"152","author":"Watanabe","year":"2017","journal-title":"Am. J. Orthod. Dentofac. Orthop."},{"key":"ref_92","first-page":"22","article-title":"Intermaxillary fixation-torture or therapy?","volume":"4","author":"Mardirossian","year":"1982","journal-title":"Clin. Prev. Dent."},{"key":"ref_93","doi-asserted-by":"crossref","unstructured":"Nayak, S.S., Gadicherla, S., Roy, S., Chichra, M., Dhaundiyal, S., Nayak, V.S., and Kamath, V. (2023). Assessment of quality of life in patients with surgically treated maxillofacial fractures. F1000Research, 12.","DOI":"10.12688\/f1000research.129579.2"},{"key":"ref_94","doi-asserted-by":"crossref","first-page":"1821","DOI":"10.1016\/j.jcms.2014.06.021","article-title":"Quality of life in treatment of mandibular fractures using closed reduction and maxillomandibular fixation in comparison with open reduction and internal fixation\u2014A randomized prospective study","volume":"42","author":"Omeje","year":"2014","journal-title":"J. Craniomaxillofac. Surg."},{"key":"ref_95","doi-asserted-by":"crossref","first-page":"1004","DOI":"10.1016\/j.jcms.2015.05.009","article-title":"IMF-screws or arch bars as conservative treatment for mandibular condyle fractures: Quality of life aspects","volume":"43","author":"Tuinzing","year":"2015","journal-title":"J. Craniomaxillofac. Surg."},{"key":"ref_96","doi-asserted-by":"crossref","first-page":"23","DOI":"10.7181\/acfs.2021.00549","article-title":"Comparison of intermaxillary fixation techniques for mandibular fractures with focus on patient experience","volume":"23","author":"Kim","year":"2022","journal-title":"Arch. Craniofac. Surg."},{"key":"ref_97","doi-asserted-by":"crossref","first-page":"648","DOI":"10.1016\/j.joms.2024.03.009","article-title":"Does maxillomandibular fixation technique affect occlusion quality in segmental LeFort I osteotomy?","volume":"82","author":"Han","year":"2024","journal-title":"J. Oral Maxillofac. Surg."},{"key":"ref_98","doi-asserted-by":"crossref","first-page":"728","DOI":"10.1016\/j.bjoms.2020.04.040","article-title":"Perils of intermaxillary fixation screws","volume":"58","author":"Ali","year":"2020","journal-title":"Br. J. Oral Maxillofac. Surg."},{"key":"ref_99","doi-asserted-by":"crossref","unstructured":"Sharaf, B.A., Morris, J.M., and Kuruoglu, D. (2021). EPPOCRATIS: A point-of-care utilization of virtual surgical planning and three-dimensional printing for the management of acute craniomaxillofacial trauma. J. Clin. Med., 10.","DOI":"10.3390\/jcm10235640"},{"key":"ref_100","first-page":"1427","article-title":"Craniomaxillofacial trauma: The past, present and the future","volume":"34","author":"Salinas","year":"2023","journal-title":"J. Craniofac. Surg."},{"key":"ref_101","unstructured":"Liokatis, P.G., Cornelius, C.P., Thompson, G., Gebretsadik, H., and Diaz, V. (2025). A registry study to collect clinical data on the MatrixWAVETM Mandibulo-Maxillary Fixation System (FRMatrixWAVE). Patient recruitment and data evaluation completed. In Preparation\u2014End 2025, in press."},{"key":"ref_102","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1177\/19433875231176339","article-title":"Trends in maxillomandibular fixation technique at a single academic institution","volume":"17","author":"Schopper","year":"2024","journal-title":"Craniomaxillofac. Trauma Reconstr."},{"key":"ref_103","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1089\/fpsam.2024.0113","article-title":"Maxillomandibular fixation: Understanding the risks and benefits of contemporary techniques in adults","volume":"27","author":"Johnson","year":"2025","journal-title":"Facial Plast Surg. Aesthet. Med."},{"key":"ref_104","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1097\/MOO.0000000000001043","article-title":"Techniques for maxillomandibular fixation: Old and new","volume":"33","author":"Akkina","year":"2025","journal-title":"Curr. Opin. Otolaryngol. Head Neck Surg."},{"key":"ref_105","doi-asserted-by":"crossref","first-page":"7","DOI":"10.14219\/jada.archive.1964.0034","article-title":"The simplified oral hygiene index","volume":"68","author":"Greene","year":"1964","journal-title":"J. Am. Dent. Assoc."},{"key":"ref_106","first-page":"41","article-title":"Reduced plaque formation by the chloromethyl analogue of victamine C","volume":"41","author":"Turesky","year":"1970","journal-title":"J. Periodontol."},{"key":"ref_107","doi-asserted-by":"crossref","first-page":"26","DOI":"10.14219\/jada.archive.1962.0184","article-title":"Comparative cleansing efficiency of manual and power brushing","volume":"65","author":"Quigley","year":"1962","journal-title":"J. Am. Dent. Assoc."},{"key":"ref_108","doi-asserted-by":"crossref","first-page":"1174","DOI":"10.1016\/0278-2391(95)90628-2","article-title":"A prospective study of the efficacy of various gloving techniques in the application of Erich arch bars","volume":"53","author":"Pieper","year":"1995","journal-title":"J. Oral Maxillofac. Surg."},{"key":"ref_109","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1111\/ger.12270","article-title":"General Oral Health Assessment Index: A new evaluation proposal","volume":"34","author":"Campos","year":"2017","journal-title":"Gerodontology"},{"key":"ref_110","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1016\/S0901-5027(05)80156-0","article-title":"Intermaxillary fixation using screws. Report of a technique","volume":"20","author":"Win","year":"1991","journal-title":"Int. J. Oral Maxillofac. Surg."},{"key":"ref_111","doi-asserted-by":"crossref","first-page":"e59","DOI":"10.1016\/j.bjoms.2012.04.075","article-title":"Simple way of fixing a Gunning-type splint to the bone using intermaxillary fixation screws: Technical note","volume":"51","author":"Newaskar","year":"2013","journal-title":"Br. J. Oral Maxillofac. Surg."},{"key":"ref_112","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1007\/s12663-013-0481-z","article-title":"Maxillo Mandibular Fixation in Edentulous Scenarios: Combined MMF Screws and Gunning Splints","volume":"13","author":"Chaudhary","year":"2014","journal-title":"J. Maxillofac. Oral Surg."},{"key":"ref_113","unstructured":"Wolter, D. (1989). Bone Plate Arrangement. (No. 4,794,918), U.S. Patent."},{"key":"ref_114","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1007\/s100390050055","article-title":"Universeller Titanfixateur interne.Entwicklungsgeschichte, Prinzip, Mechanik, Implantatgestaltung und operativer Einsatz. [The universal titanium internal fixator. Development, mechanics, implant design, and surgical application]","volume":"1","author":"Wolter","year":"1999","journal-title":"Trauma Berufskrankheit."},{"key":"ref_115","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1111\/joor.13303","article-title":"The mouth-opening muscular performance in adults with and without temporomandibular disorders: A systematic review","volume":"49","author":"Greenbaum","year":"2022","journal-title":"J. Oral Rehabil."},{"key":"ref_116","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1111\/ocr.12215","article-title":"Estimation of jaw-opening forces in adults","volume":"21","author":"Brunton","year":"2018","journal-title":"Orthod. Craniofac. Res."},{"key":"ref_117","doi-asserted-by":"crossref","first-page":"470","DOI":"10.11607\/jomi.2659","article-title":"Positional guidelines for orthodontic mini-implant placement in the anterior alveolar region: A systematic review","volume":"28","author":"Alsamak","year":"2013","journal-title":"Int. J. Oral. Maxillofac. Implants"},{"key":"ref_118","doi-asserted-by":"crossref","first-page":"102","DOI":"10.5152\/TurkJOrthod.2021.20070","article-title":"Cone-Beam Computed Tomographic Assessment of Bone Thickness in the Mandibular Anterior Region for Application of Orthodontic Mini-Screws","volume":"34","author":"Shalchi","year":"2021","journal-title":"Turk. J. Orthod."},{"key":"ref_119","doi-asserted-by":"crossref","first-page":"939","DOI":"10.2319\/121009-709.1","article-title":"Optimal sites for orthodontic mini-implant placement assessed by cone beam computed tomography","volume":"80","author":"Fayed","year":"2010","journal-title":"Angle Orthod."},{"key":"ref_120","doi-asserted-by":"crossref","unstructured":"Limeres Posse, J., Abeleira Pazos, M.T., Fernandez Casado, M., Outumuro Rial, M., Diz Dios, P., and Diniz-Freitas, M. (2019). Safe zones of the maxillary alveolar bone in Down syndrome for orthodontic miniscrew placement assessed with cone-beam computed tomography. Sci. Rep., 9.","DOI":"10.1038\/s41598-019-49345-0"},{"key":"ref_121","doi-asserted-by":"crossref","unstructured":"Hasani, M., Afzoon, S., Karandish, M., and Parastar, M. (2023). Three-dimensional evaluation of the cortical and cancellous bone density and thickness for miniscrew insertion: A CBCT study of interradicular area of adults with different facial growth pattern. BMC Oral Health, 23.","DOI":"10.1186\/s12903-023-03440-x"},{"key":"ref_122","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1097\/ID.0000000000000036","article-title":"Effect of 3 vertical facial patterns on alveolar bone quality at selected miniscrew implant sites","volume":"23","author":"Li","year":"2014","journal-title":"Implant Dent."},{"key":"ref_123","doi-asserted-by":"crossref","first-page":"745","DOI":"10.2319\/011117-34.1","article-title":"Bone and cortical bone thickness of mandibular buccal shelf for mini- screw insertion in adults","volume":"87","author":"Nucera","year":"2017","journal-title":"Angle Orthod."},{"key":"ref_124","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1016\/j.ajodo.2018.04.025","article-title":"Bone and cortical bone characteristics of mandibular retromolar trigone and anterior ramus region for miniscrew insertion in adults","volume":"155","author":"Nucera","year":"2019","journal-title":"Am. J. Orthod. Dentofac. Orthop."}],"container-title":["Craniomaxillofacial Trauma &amp; Reconstruction"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1943-3883\/18\/3\/33\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T18:09:47Z","timestamp":1760033387000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1943-3883\/18\/3\/33"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,15]]},"references-count":124,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2025,9]]}},"alternative-id":["cmtr18030033"],"URL":"https:\/\/doi.org\/10.3390\/cmtr18030033","relation":{},"ISSN":["1943-3883"],"issn-type":[{"type":"electronic","value":"1943-3883"}],"subject":[],"published":{"date-parts":[[2025,7,15]]}}}