{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T17:56:22Z","timestamp":1787680582602,"version":"build-2784847793"},"reference-count":24,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2020,6,5]],"date-time":"2020-06-05T00:00:00Z","timestamp":1591315200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Diagnostics"],"abstract":"<jats:p>Magnetic resonance cholangiopancreatography (MRCP) has been widely used in clinical practice, and recently developed compressed-sensing accelerated MRCP (CS-MRCP) has shown great potential in shortening the acquisition time. The purpose of this prospective study was to evaluate the clinical feasibility and image quality of optimized breath-hold CS-MRCP (BH-CS-MRCP) and conventional navigator-triggered MRCP. Data from 124 consecutive patients with suspected pancreaticobiliary diseases were analyzed by two radiologists using a five-point Likert-type scale. Communication between a cyst and the pancreatic duct (PD) was analyzed. Signal-to-noise ratio (SNR) of the common bile duct (CBD), contrast ratio between the CBD and periductal tissue, and contrast-to-noise ratio (CNR) of the CBD and liver were measured. Optimized BH-CS-MRCP showed significantly fewer artifacts with better background suppression and overall image quality. Optimized BH-CS-MRCP demonstrated communication between a cyst and the PD better than conventional MRCP (96.7% vs. 76.7%, p = 0.048). SNR, contrast ratio, and CNR were significantly higher with optimized BH-CS-MRCP (p &lt; 0.001). Optimized BH-CS-MRCP showed comparable or even better image quality than conventional MRCP, with improved visualization of communication between a cyst and the PD.<\/jats:p>","DOI":"10.3390\/diagnostics10060376","type":"journal-article","created":{"date-parts":[[2020,6,9]],"date-time":"2020-06-09T04:19:39Z","timestamp":1591676379000},"page":"376","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":21,"title":["Optimized Breath-Hold Compressed-Sensing 3D MR Cholangiopancreatography at 3T: Image Quality Analysis and Clinical Feasibility Assessment"],"prefix":"10.3390","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4264-5320","authenticated-orcid":false,"given":"Ji Soo","family":"Song","sequence":"first","affiliation":[{"name":"Department of Radiology, Jeonbuk National University Medical School and Hospital, Jeonju 54907, Korea"},{"name":"Research Institute of Clinical Medicine of Jeonbuk National University, Jeonju 54907, Korea"},{"name":"Biomedical Research Institute of Jeonbuk National University Hospital, Jeonju 54907, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7592-8060","authenticated-orcid":false,"given":"Seung Hun","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Jeonbuk National University Medical School, Jeonju 54907, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bernd","family":"Kuehn","sequence":"additional","affiliation":[{"name":"Siemens Healthineers Ltd., 91052 Erlangen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mun Young","family":"Paek","sequence":"additional","affiliation":[{"name":"Siemens Healthineers Ltd., Seoul 03737, Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2020,6,5]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1056\/NEJM199907223410407","article-title":"Magnetic resonance cholangiopancreatography","volume":"341","author":"Barish","year":"1999","journal-title":"N. Engl. J. Med."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1002\/jmri.10446","article-title":"The utility of MRCP in preoperative mapping of biliary anatomy in adult-to-adult living related liver transplant donors","volume":"19","author":"Limanond","year":"2004","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1002\/jmri.23609","article-title":"Magnetic resonance imaging findings of the mass-forming type of autoimmune pancreatitis: Comparison with pancreatic adenocarcinoma","volume":"36","author":"Hur","year":"2012","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"888","DOI":"10.1259\/bjr\/51075444","article-title":"Is magnetic resonance cholangiopancreatography the new gold standard in biliary imaging?","volume":"78","author":"Shanmugam","year":"2005","journal-title":"Br. J. Radiol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1148\/radiology.206.2.9457189","article-title":"Optimal MR cholangiopancreatographic sequence and its clinical application","volume":"206","author":"Irie","year":"1998","journal-title":"Radiology"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1097\/RCT.0b013e3181852193","article-title":"Another dimension in magnetic resonance cholangiopancreatography: Comparison of 2- and 3-dimensional magnetic resonance cholangiopancreatography for the evaluation of intraductal papillary mucinous neoplasm of the pancreas","volume":"33","author":"Yoon","year":"2009","journal-title":"J. Comput. Assist. Tomogr."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1002\/jmri.21485","article-title":"Navigator-triggered prospective acquisition correction (PACE) technique vs. conventional respiratory-triggered technique for free-breathing 3D MRCP: An initial prospective comparative study using healthy volunteers","volume":"28","author":"Morita","year":"2008","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"612","DOI":"10.1097\/RLI.0000000000000380","article-title":"Clinical Feasibility of 3-Dimensional Magnetic Resonance Cholangiopancreatography Using Compressed Sensing: Comparison of Image Quality and Diagnostic Performance","volume":"52","author":"Yoon","year":"2017","journal-title":"Invest. Radiol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"939","DOI":"10.1016\/j.mri.2005.07.002","article-title":"Magnetic resonance cholangiopancreatography using a free-breathing T2-weighted turbo spin-echo sequence with navigator-triggered prospective acquisition correction","volume":"23","author":"Asbach","year":"2005","journal-title":"Magn. Reson. Imaging"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"e513","DOI":"10.1016\/j.ejrad.2011.06.004","article-title":"Clinical usefulness of free-breathing navigator-triggered 3D MRCP in non-cooperative patients: Comparison with conventional breath-hold 2D MRCP","volume":"81","author":"Kim","year":"2012","journal-title":"Eur. J. Radiol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1148\/radiol.2016151935","article-title":"Three-dimensional MR Cholangiopancreatography in a Breath Hold with Sparsity-based Reconstruction of Highly Undersampled Data","volume":"280","author":"Chandarana","year":"2016","journal-title":"Radiology"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1289","DOI":"10.1002\/jmri.25672","article-title":"Feasibility of 3D navigator-triggered magnetic resonance cholangiopancreatography with combined parallel imaging and compressed sensing reconstruction at 3T","volume":"46","author":"Seo","year":"2017","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1097\/RLI.0000000000000421","article-title":"Compressed-Sensing Accelerated 3-Dimensional Magnetic Resonance Cholangiopancreatography: Application in Suspected Pancreatic Diseases","volume":"53","author":"Zhu","year":"2018","journal-title":"Invest. Radiol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1389","DOI":"10.1002\/jmri.26049","article-title":"Modified breath-hold compressed-sensing 3D MR cholangiopancreatography with a small field-of-view and high resolution acquisition: Clinical feasibility in biliary and pancreatic disorders","volume":"48","author":"Zhu","year":"2018","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1002\/jmri.21484","article-title":"High-spatial-resolution three-dimensional MR cholangiography using a high-sampling-efficiency technique (SPACE) at 3T: Comparison with the conventional constant flip angle sequence in healthy volunteers","volume":"28","author":"Arizono","year":"2008","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1007\/s10334-014-0471-2","article-title":"Improving the robustness of 3D turbo spin echo imaging to involuntary motion","volume":"28","author":"Li","year":"2015","journal-title":"MAGMA"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1346","DOI":"10.1002\/jmri.25289","article-title":"Usefulness of 3D hybrid profile order technique with 3T magnetic resonance cholangiography: Comparison of image quality and acquisition time","volume":"44","author":"Yokoyama","year":"2016","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1097\/RCT.0000000000000401","article-title":"Usefulness of the Short-Echo Time Cube Sequence at 3-T Magnetic Resonance Cholangiopancreatography: Prospective Comparison With the Conventional 3-Dimensional Fast Spin-Echo Sequence","volume":"40","author":"Itatani","year":"2016","journal-title":"J. Comput. Assist. Tomogr."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1313","DOI":"10.1016\/j.mri.2012.05.005","article-title":"Signal-to-noise ratio, contrast-to-noise ratio and pharmacokinetic modeling considerations in dynamic contrast-enhanced magnetic resonance imaging","volume":"30","author":"Li","year":"2012","journal-title":"Magn. Reson. Imaging"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1097\/RLI.0000000000000489","article-title":"Acceleration of Magnetic Resonance Cholangiopancreatography Using Compressed Sensing at 1.5 and 3 T: A Clinical Feasibility Study","volume":"53","author":"Taron","year":"2018","journal-title":"Invest. Radiol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"2393","DOI":"10.1007\/s00261-017-1145-0","article-title":"Transient severe motion in the arterial phase during gadoxetate disodium-enhanced MR imaging: Evaluation of patients with multiple MR examinations","volume":"42","author":"Im","year":"2017","journal-title":"Abdom. Radiol. (NY)"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1132","DOI":"10.1007\/s00330-017-5070-y","article-title":"Comparison of transient severe motion in gadoxetate disodium and gadopentetate dimeglumine-enhanced MRI: Effect of modified breath-holding method","volume":"28","author":"Song","year":"2018","journal-title":"Eur. Radiol."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"2436","DOI":"10.1007\/s00330-017-5240-y","article-title":"Magnetic resonance cholangiopancreatography with GRASE sequence at 3.0T: Does it improve image quality and acquisition time as compared with 3D TSE?","volume":"28","author":"Yoshida","year":"2018","journal-title":"Eur. Radiol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"20150487","DOI":"10.1259\/bjr.20150487","article-title":"Compressed sensing MRI: A review of the clinical literature","volume":"88","author":"Jaspan","year":"2015","journal-title":"Br. J. Radiol."}],"container-title":["Diagnostics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4418\/10\/6\/376\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T09:36:09Z","timestamp":1760175369000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4418\/10\/6\/376"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6,5]]},"references-count":24,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2020,6]]}},"alternative-id":["diagnostics10060376"],"URL":"https:\/\/doi.org\/10.3390\/diagnostics10060376","relation":{},"ISSN":["2075-4418"],"issn-type":[{"value":"2075-4418","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,6,5]]}}}