{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T22:06:52Z","timestamp":1791929212298,"version":"4.3.4"},"reference-count":39,"publisher":"MDPI AG","issue":"10","license":[{"start":{"date-parts":[[2021,10,11]],"date-time":"2021-10-11T00:00:00Z","timestamp":1633910400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Diagnostics"],"abstract":"<jats:p>Using computer tomography angiography (CTA) and computational structural analysis, we present a non-invasive method of mass flow rate\/velocity and wall stress analysis in type B aortic dissection. Three-dimensional (3D) computer models of the aorta were calculated using pre-operative (baseline) and post-operative CT data from 12 male patients (aged from 51 to 64 years) who were treated for acute type B dissection. A computational fluid dynamics (CFD) technique was used to quantify the displacement forces acting on the aortic wall in the areas of endografts placement. The mass flow rate and wall stress were measured and quantified using the CFD technique. The CFD model indicated the places with a lower value of blood velocity and shear rate, which corelated with higher blood viscosity and a probability of thrombus appearance. Moreover, with the increase in Hct, blood viscosity also increased, while the intensity of blood flow provoked changing viscosity values in these areas. Furthermore, the velocity gradient near the tear surface caused high wall WSS; this could lead to a decreased resistance in the aorta\u2019s wall with further implications to a patient.<\/jats:p>","DOI":"10.3390\/diagnostics11101866","type":"journal-article","created":{"date-parts":[[2021,10,11]],"date-time":"2021-10-11T09:16:42Z","timestamp":1633943802000},"page":"1866","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":29,"title":["Computational Fluid Dynamic Technique for Assessment of How Changing Character of Blood Flow and Different Value of Hct Influence Blood Hemodynamic in Dissected Aorta"],"prefix":"10.3390","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8894-752X","authenticated-orcid":false,"given":"Andrzej","family":"Polanczyk","sequence":"first","affiliation":[{"name":"The Faculty of Safety Engineering and Civil Protection, The Main School of Fire Service, 01-629 Warsaw, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8062-4435","authenticated-orcid":false,"given":"Aleksandra","family":"Piechota-Polanczyk","sequence":"additional","affiliation":[{"name":"Department of Medical Biotechnology, Faculty of Biochemistry, Biophysics and Biotechnology, Jagiellonian University, Gronostajowa 7 Street, 30-387 Krakow, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ihor","family":"Huk","sequence":"additional","affiliation":[{"name":"Department of Surgery, Division of Vascular Surgery, Medical University of Vienna, Spitalgasse 23, 1090 Wien, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1407-4185","authenticated-orcid":false,"given":"Christoph","family":"Neumayer","sequence":"additional","affiliation":[{"name":"Department of Surgery, Division of Vascular Surgery, Medical University of Vienna, Spitalgasse 23, 1090 Wien, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julia","family":"Balcer","sequence":"additional","affiliation":[{"name":"The Faculty of Electrical, Electronic, Computer and Control Engineering-Technologies, Lodz University of Technology, 93-924 Lodz, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9102-4929","authenticated-orcid":false,"given":"Michal","family":"Strzelecki","sequence":"additional","affiliation":[{"name":"Institute of Electronics, Lodz University of Technology, 93-590 Lodz, Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2021,10,11]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1177\/1358863X16632898","article-title":"Aortic dissection","volume":"21","author":"Salameh","year":"2016","journal-title":"Vasc. Med."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"e82","DOI":"10.1093\/ejcts\/ezs640","article-title":"Aortic dissection in the outer third of the media: What is the role of the vasa vasorum in the triggering process?","volume":"43","author":"Osada","year":"2013","journal-title":"Eur. J. Cardio-Thorac. Surg."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s40560-018-0287-7","article-title":"Management of acute aortic dissection and thoracic aortic rupture","volume":"6","author":"Fukui","year":"2018","journal-title":"J. Intensiv. Care"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1080\/14017431.2019.1660401","article-title":"Acute type A aortic dissection\u2014A review","volume":"54","author":"Gudbjartsson","year":"2020","journal-title":"Scand. Cardiovasc. J."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1007\/s00268-018-4768-6","article-title":"Outcomes Following Non-operative Management of Thoracic and Thoracoabdominal Aneurysms","volume":"43","author":"Piffaretti","year":"2019","journal-title":"World J. Surg."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.jacc.2014.08.025","article-title":"Thoracic aortic aneurysm and dissection","volume":"64","author":"Goldfinger","year":"2014","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1016\/j.jtcvs.2014.05.051","article-title":"Acute type A aortic dissection extending beyond ascending aorta: Limited or extensive distal repair","volume":"148","author":"Rylski","year":"2014","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1007\/s00059-018-4694-2","article-title":"Aortenerkrankungen","volume":"43","author":"Erbel","year":"2018","journal-title":"Herz"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1016\/j.amjcard.2010.10.039","article-title":"Usefulness of Comprehensive Cardiothoracic Computed Tomography in the Evaluation of Acute Undifferentiated Chest Discomfort in the Emergency Department (CAPTURE)","volume":"107","author":"Rogers","year":"2011","journal-title":"Am. J. Cardiol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1016\/j.ajem.2016.11.039","article-title":"MR angiography can guide ED management of suspected acute aortic dissection","volume":"35","author":"Wang","year":"2017","journal-title":"Am. J. Emerg. Med."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1016\/j.jvs.2015.02.048","article-title":"Use of computational fluid dynamics studies in predicting aneurysmal degeneration of acute type B aortic dissections","volume":"62","author":"Shang","year":"2015","journal-title":"J. Vasc. Surg."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Polanczyk, A., Piechota-Polanczyk, A., Stefa\u0144czyk, L., and Strzelecki, M. (2020). Spatial Configuration of Abdominal Aortic Aneurysm Analysis as a Useful Tool for the Estimation of Stent-Graft Migration. Diagnostics, 10.","DOI":"10.3390\/diagnostics10100737"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/j.medengphy.2008.03.005","article-title":"Analysis of type I endoleaks in a stented abdominal aortic aneurysm","volume":"31","author":"Amblard","year":"2009","journal-title":"Med. Eng. Phys."},{"key":"ref_14","first-page":"10","article-title":"Computational Approach to Optimal Transport Network Construction in Biomechanics","volume":"3044","author":"Kizilova","year":"2004","journal-title":"Lect. Notes Comput. Sci."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1109\/TMI.2009.2039579","article-title":"Reconstruction and Finite Element Mesh Generation of Abdominal Aortic Aneurysms from Computerized Tomography Angiography Data with Minimal User Interactions","volume":"29","author":"Auer","year":"2010","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1129","DOI":"10.1007\/s11517-008-0361-8","article-title":"A computational study on the biomechanical factors related to stent-graft models in the thoracic aorta","volume":"46","author":"Lam","year":"2008","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"927","DOI":"10.1007\/s10439-018-2012-z","article-title":"Coupled Morphological\u2013Hemodynamic Computational Analysis of Type B Aortic Dissection: A Longitudinal Study","volume":"46","author":"Xu","year":"2018","journal-title":"Ann. Biomed. Eng."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1111\/j.1365-2796.2006.01624.x","article-title":"Molecular mechanisms of the vascular responses to haemodynamic forces","volume":"259","author":"Lehoux","year":"2006","journal-title":"J. Intern. Med."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Polanczyk, A., Piechota-Polanczyk, A., Stefanczyk, L., and Strzelecki, M. (2020). Shape and Enhancement Analysis as a Useful Tool for the Presentation of Blood Hemodynamic Properties in the Area of Aortic Dissection. J. Clin. Med., 9.","DOI":"10.3390\/jcm9051330"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.jvs.2010.07.008","article-title":"Reporting standards for thoracic endovascular aortic repair (TEVAR)","volume":"52","author":"Fillinger","year":"2010","journal-title":"J. Vasc. Surg."},{"key":"ref_21","first-page":"4","article-title":"Optimization of image quality in pulmonary CT angiography with low dose of contrast material","volume":"23","author":"Assi","year":"2017","journal-title":"Pol. J. Med. Phys. Eng."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1007\/s00330-006-0277-3","article-title":"Image quality in CT perfusion imaging of the brain","volume":"17","author":"Koenen","year":"2007","journal-title":"Eur. Radiol."},{"key":"ref_23","first-page":"103","article-title":"Evaluating an algorithm for 3D reconstruction of blood vessels for further simulations of hemodynamic in human artery branches","volume":"5","author":"Polanczyk","year":"2016","journal-title":"IEEE Xplore Digit. Lbrary"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Polanczyk, A., Piechota-Polanczyk, A., and Stefa\u0144czyk, L. (2017). A new approach for the pre-clinical optimization of a spatial configuration of bifurcated endovascular prosthesis placed in abdominal aortic aneurysms. PLoS ONE, 12.","DOI":"10.1371\/journal.pone.0182717"},{"key":"ref_25","first-page":"13","article-title":"3D Blood Vessels Reconstruction Based on Segmented CT Data for Further Simulations of Hemodynamic in Human Artery Branches","volume":"42","author":"Strzelecki","year":"2017","journal-title":"Found. Comput. Decis. Sci."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Polanczyk, A., Podyma, M., Trebinski, L., Chrzastek, J., Zbicinski, I., and Stefanczyk, L. (2016). A Novel Attempt to Standardize Results of CFD Simulations Basing on Spatial Configuration of Aortic Stent-Grafts. PLoS ONE, 11.","DOI":"10.1371\/journal.pone.0153332"},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Polanczyk, A., Klinger, M., Nanobachvili, J., Huk, I., and Neumayer, C. (2018). Artificial Circulatory Model for Analysis of Human and Artificial Vessels. Appl. Sci., 8.","DOI":"10.3390\/app8071017"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1016\/j.jbiomech.2014.12.033","article-title":"A 3D model of thrombus formation in a stent-graft after implantation in the abdominal aorta","volume":"48","author":"Polanczyk","year":"2015","journal-title":"J. Biomech."},{"key":"ref_29","first-page":"9","article-title":"Effects of stent-graft geometry and blood hematocrit on hemodynamic in Abdominal Aortic Aneurysm","volume":"33","author":"Podyma","year":"2012","journal-title":"Chem. Process. Eng."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Polanczyk, A., Podgorski, M., Wozniak, T., Stefanczyk, L., and Strzelecki, M. (2018). Computational Fluid Dynamics as an Engineering Tool for the Reconstruction of Hemodynamics after Carotid Artery Stenosis Operation: A Case Study. Medicina, 54.","DOI":"10.3390\/medicina54030042"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1016\/j.bbe.2018.01.004","article-title":"Numerical simulations of the pulsatile blood flow in the different types of arterial fenestrations: Comparable analysis of multiple vascular geometries","volume":"38","author":"Tyfa","year":"2018","journal-title":"Biocybern. Biomed. Eng."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1016\/j.jvs.2012.02.064","article-title":"Longitudinal computational fluid dynamics study of aneurysmal dilatation in a chronic DeBakey type III aortic dissection","volume":"56","author":"Karmonik","year":"2012","journal-title":"J. Vasc. Surg."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"844","DOI":"10.1016\/j.jvs.2007.11.059","article-title":"Tear size and location impacts false lumen pressure in an ex vivo model of chronic type B aortic dissection","volume":"47","author":"Tsai","year":"2008","journal-title":"J. Vasc. Surg."},{"key":"ref_34","first-page":"13","article-title":"Prediction of thrombus formation using vortical structures presentation in Stanford type B aortic dissection: A preliminary study using CFD approach","volume":"40","author":"Ganesan","year":"2016","journal-title":"Appl. Math. Model."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1177\/0954411914540877","article-title":"Regional variation of wall shear stress in ascending thoracic aortic aneurysms","volume":"228","author":"Rinaudo","year":"2014","journal-title":"Proc. Inst. Mech. Eng. Part H J. Eng. Med."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1136\/neurintsurg-2011-010089","article-title":"Newtonian viscosity model could overestimate wall shear stress in intracranial aneurysm domes and underestimate rupture risk","volume":"4","author":"Xiang","year":"2012","journal-title":"J. NeuroInterventional Surg."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"35S","DOI":"10.1016\/j.jvs.2012.07.061","article-title":"Initial findings and potential applicability of computational simulation of the aorta in acute type B dissection","volume":"57","author":"Cheng","year":"2013","journal-title":"J. Vasc. Surg."},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Lo, E.W.C., Menezes, L.J., and Torii, R. (2019). Impact of Inflow Boundary Conditions on the Calculation of CT-Based FFR. Fluids, 4.","DOI":"10.3390\/fluids4020060"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"e3207","DOI":"10.1002\/cnm.3207","article-title":"Geometrical effects in the hemodynamics of stenotic and non-stenotic left coronary arteries\u2014Numerical and in vitro approaches","volume":"35","author":"Doutel","year":"2019","journal-title":"Int. J. Numer. Methods Biomed. Eng."}],"container-title":["Diagnostics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4418\/11\/10\/1866\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T07:11:30Z","timestamp":1760166690000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4418\/11\/10\/1866"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10,11]]},"references-count":39,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2021,10]]}},"alternative-id":["diagnostics11101866"],"URL":"https:\/\/doi.org\/10.3390\/diagnostics11101866","relation":{},"ISSN":["2075-4418"],"issn-type":[{"value":"2075-4418","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,10,11]]}}}