{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T11:00:26Z","timestamp":1790420426515,"version":"4.1.0"},"reference-count":39,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2022,1,7]],"date-time":"2022-01-07T00:00:00Z","timestamp":1641513600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Diagnostics"],"abstract":"<jats:p>Early detection of scoliosis with school screening and quick, easy, and reliable assessment of its progress are of paramount importance in the management of patients. There have been several tools described, with the most common being the analog scoliometer. Most recently, smartphone applications have entered this area with and without the use of sleeves for the device. There is no research that has evaluated the accuracy of measurements both left and right in either digital or analog devices. In this study, we evaluated the reliability and validity of a new digital scoliometer called the Scolioscope. Thirty subjects were included for the intra-rater reliability study. ICC values &gt;0.9 were calculated both for same-day and between-day measurements. The device was highly accurate with an average difference from the ones set on the sine bar of 0.03\u00b0 for right-side measurements and 0.18\u00b0 for the left. These measurements suggest a highly accurate and reliable tool.<\/jats:p>","DOI":"10.3390\/diagnostics12010142","type":"journal-article","created":{"date-parts":[[2022,1,9]],"date-time":"2022-01-09T20:29:26Z","timestamp":1641760166000},"page":"142","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Study on the Reliability and Accuracy of Scolioscope, a New Digital Scoliometer"],"prefix":"10.3390","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4760-6766","authenticated-orcid":false,"given":"Georgios","family":"Krekoukias","sequence":"first","affiliation":[{"name":"Medical School, National and Kapodistrian University of Athens, 11527 Athens, Greece"},{"name":"Laboratory of Advanced Physiotherapy, Physiotherapy Department, School of Health & Care Sciences, University of West Attica (UNIWA), 12243 Athens, Greece"},{"name":"Department of Physiotherapy, Health School, Metropolitan College, 10672 Athens, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7709-2802","authenticated-orcid":false,"given":"George A.","family":"Koumantakis","sequence":"additional","affiliation":[{"name":"Laboratory of Advanced Physiotherapy, Physiotherapy Department, School of Health & Care Sciences, University of West Attica (UNIWA), 12243 Athens, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vasileios S.","family":"Nikolaou","sequence":"additional","affiliation":[{"name":"Medical School, National and Kapodistrian University of Athens, 11527 Athens, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Konstantinos","family":"Soultanis","sequence":"additional","affiliation":[{"name":"Medical School, National and Kapodistrian University of Athens, 11527 Athens, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2022,1,7]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1527","DOI":"10.1016\/S0140-6736(08)60658-3","article-title":"Adolescent idiopathic scoliosis","volume":"371","author":"Weinstein","year":"2008","journal-title":"Lancet"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"S14","DOI":"10.1097\/BPO.0b013e3181f73c12","article-title":"Top theories for the etiopathoenesis of adolescent idiopathic scoliosis","volume":"31","author":"Wang","year":"2011","journal-title":"J. Pediatr. Orthop."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"7","DOI":"10.3109\/09593985.2010.503990","article-title":"Patient evaluation in idiopathic scoliosis: Radiographic assessment, trunk deformity and back asymmetry","volume":"27","author":"Rigo","year":"2011","journal-title":"Physiother. Theory Pract."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1007\/s11832-012-0457-4","article-title":"Epidemiology of adolescent idiopathic scoliosis","volume":"7","author":"Konieczny","year":"2013","journal-title":"J. Child Orthop."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1097\/01241398-199507000-00025","article-title":"An evaluation of the Adams forward bend test and the scoliometer in a scoliosis school screening setting","volume":"15","author":"Grossman","year":"1995","journal-title":"J. Pediatr. Orthop."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"796","DOI":"10.1097\/00007632-199804010-00011","article-title":"A study of the diagnostic accuracy and reliability of the Scoliometer and Adam\u2019s forward bend test","volume":"23","author":"Kreitz","year":"1998","journal-title":"Spine"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"2318","DOI":"10.1097\/00007632-199911150-00006","article-title":"Ten-year follow-up evaluation of a school screening program for scoliosis. Is the forward-bending test an accurate diagnostic criterion for the screening of scoliosis?","volume":"24","author":"Karachalios","year":"1999","journal-title":"Spine"},{"key":"ref_8","unstructured":"(2021, March 16). SRS\/POSNA\/AAOS\/AAP Position Statement\u2014Screening for the Early Detection for Idiopathic Scoliosis in Adolescents. Available online: https:\/\/www.srs.org\/about-srs\/news-and-announcements\/position-statement---screening-for-the-early-detection-for-idiopathic-scoliosis-in-adolescents."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"301","DOI":"10.3233\/BMR-200215","article-title":"Adolescent idiopathic scoliosis screening: Could a school-based assessment protocol be useful for an early diagnosis?","volume":"34","author":"Scaturro","year":"2020","journal-title":"J. Back Musculoskelet. Rehabil."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1590\/S1413-35552012005000081","article-title":"Scoliometer measurements of patients with idiopathic scoliosis","volume":"17","author":"Coelho","year":"2013","journal-title":"Braz. J. Phys. Ther."},{"key":"ref_11","first-page":"42","article-title":"Recent developments in scoliosis surgery","volume":"22","author":"Kiely","year":"2008","journal-title":"Orthop. Trauma"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1186\/1748-7161-4-26","article-title":"Members of the International Society on Scoliosis Orthopaedic Rehabilitation and Treatment Methodology of evaluation of morphology of the spine and thetrunk in idiopathic scoliosis and other spinal deformities\u20146thSOSORT consensus paper","volume":"4","author":"Kotwicki","year":"2009","journal-title":"Scoliosis"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1186\/1748-7161-9-4","article-title":"SOSORT 2012 consensus paper: Reducing X-ray exposureinpediatric patients with scoliosis","volume":"9","author":"Knott","year":"2014","journal-title":"Scoliosis"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1061","DOI":"10.1097\/BRS.0b013e3181bcc835","article-title":"A meta-analysis of the clinical effectiveness of school scoliosis screening","volume":"35","author":"Fong","year":"2010","journal-title":"Spine"},{"key":"ref_15","first-page":"261","article-title":"School scoliosis screening programme-a systematic review","volume":"65","author":"Sabirin","year":"2010","journal-title":"Med. J. Malays."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"2667","DOI":"10.1001\/jama.1993.03500200081038","article-title":"Screening for adolescent idiopathicscoliosis: Review article","volume":"269","author":"Sox","year":"1993","journal-title":"JAMA"},{"key":"ref_17","unstructured":"(2021, November 10). Reliability Analysis. Available online: https:\/\/www.statisticssolutions.com\/free-resources\/directory-of-statistical-analyses\/reliability-analysis\/."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1362","DOI":"10.1007\/s00586-013-2752-2","article-title":"Reliability of cervical lordosis and global sagittal spinal balance measurements in adolescent idiopathic scoliosis","volume":"22","author":"Vidal","year":"2013","journal-title":"Eur. Spine J."},{"key":"ref_19","unstructured":"Bowling, A. (2002). Research Methods in Health, Open University Press. [2nd ed.]."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"e72","DOI":"10.1097\/BPO.0b013e31826bb109","article-title":"Validation of a scoliometer smartphone app to assess scoliosis","volume":"32","author":"Franko","year":"2012","journal-title":"J. Pediatr. Orthop."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"774","DOI":"10.1097\/BPO.0000000000000195","article-title":"Validity and reliability of the iPhone to measure rib hump in scoliosis","volume":"34","author":"Balg","year":"2014","journal-title":"J. Pediatr. Orthop."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1016\/j.ijso.2020.10.001","article-title":"Inter-and intra-observer reliability of scoliogauge app to assess the axial trunk rotation of scoliosis: Prospective reliability analysis study","volume":"27","author":"Getnet","year":"2020","journal-title":"Int. J. Surg. Open"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1186\/1748-7161-7-14","article-title":"Evaluation of the iPhone with an acrylic sleeve versus the Scoliometer for rib hump measurement in scoliosis","volume":"7","author":"Izatt","year":"2012","journal-title":"Scoliosis"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Gerke, O. (2020). Reporting Standards for a Bland-Altman Agreement Analysis: A Review of Methodological Reviews. Diagnostics, 10.","DOI":"10.3390\/diagnostics10050334"},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Yanchun, L., Zhang, Y., Bao, W., Wang, W., and Liu, Y. (2021). Temperature Variation of Steel Plate with Different Thickness on Normalizing Process. J. Phys. Conf. Ser., 1820.","DOI":"10.1088\/1742-6596\/1820\/1\/012127"},{"key":"ref_26","unstructured":"Arifin, W.N. (2021, March 07). Sample Size Calculator. Available online: http:\/\/wnarifin.github.io."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"593","DOI":"10.4103\/0019-5154.193662","article-title":"Biostatistics Series Module 6: Correlation and Linear Regression","volume":"61","author":"Hazra","year":"2016","journal-title":"Indian J. Dermatol."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"O28","DOI":"10.1186\/1748-7161-10-S1-O28","article-title":"Validation of smartphone inclinometer tools for measuring rib hump in scoliosis patients","volume":"10","author":"Guardia","year":"2015","journal-title":"Scoliosis"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1615\/JLongTermEffMedImplants.2017020737","article-title":"A Systematic Review of All Smart Phone Applications Specifically Aimed for Use as a Scoliosis Screening Tool","volume":"28","author":"Naziri","year":"2018","journal-title":"J. Long Term Eff. Med. Implant."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1093\/ptj\/70.2.108","article-title":"Validity and reliability testing of the Scoliometer","volume":"70","author":"Amendt","year":"1990","journal-title":"Phys. Ther."},{"key":"ref_31","first-page":"136","article-title":"Examination of the back using the Bunnell scoliometer in a Belgian school population around puberty","volume":"64","author":"Plasschaert","year":"1998","journal-title":"Acta Orthop. Belg."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1381","DOI":"10.2106\/00004623-198466090-00010","article-title":"An objective criterion for scoliosis screening","volume":"66","author":"Bunnell","year":"1984","journal-title":"J. Bone Jt. Surg. Am."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1302\/0301-620X.65B4.6874719","article-title":"Standardised trunk asymmetry scores. A study of back contour in healthy school children","volume":"65","author":"Burwell","year":"1983","journal-title":"J. Bone Jt. Surg. Br."},{"key":"ref_34","first-page":"307","article-title":"Measurement in Medicine: The Analysis of Method Comparison Studies","volume":"32","author":"Altman","year":"1983","journal-title":"J. R. Stat. Society. Ser. D"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research","volume":"15","author":"Koo","year":"2016","journal-title":"J. Chiropr. Med."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"1661","DOI":"10.1097\/00007632-199607150-00010","article-title":"Prediction of scoliotic cobb angle with the use of the scoliometer","volume":"21","author":"Korovessis","year":"1996","journal-title":"Spine"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1097\/01.blo.0000068360.47147.30","article-title":"Prediction of Cobb angle in idiopathic adolescent scoliosis","volume":"411","author":"Sapkas","year":"2003","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1302\/0301-620X.58B1.1270497","article-title":"The rib hump in idiopathic scoliosis. Measurement, analysis and response to treatment","volume":"58","author":"Thulbourne","year":"1976","journal-title":"J. Bone Joint Surg. Br."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1186\/s12938-017-0427-7","article-title":"Application of two-parameter scoliometer values for predicting scoliotic Cobb angle","volume":"16","author":"Ma","year":"2017","journal-title":"Biomed. Eng. Online"}],"container-title":["Diagnostics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4418\/12\/1\/142\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,13]],"date-time":"2025-10-13T13:27:05Z","timestamp":1760362025000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4418\/12\/1\/142"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,7]]},"references-count":39,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,1]]}},"alternative-id":["diagnostics12010142"],"URL":"https:\/\/doi.org\/10.3390\/diagnostics12010142","relation":{},"ISSN":["2075-4418"],"issn-type":[{"value":"2075-4418","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1,7]]}}}