{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T00:17:38Z","timestamp":1785284258950,"version":"3.55.0"},"reference-count":28,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2022,2,26]],"date-time":"2022-02-26T00:00:00Z","timestamp":1645833600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["81971697"],"award-info":[{"award-number":["81971697"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Diagnostics"],"abstract":"<jats:p>This research aimed to investigate the potential differences in the parameters, including axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), flat keratometry (Kf), steep keratometry (Ks), mean keratometry (Km), astigmatism, white-to-white (WTW) distance, acquired rate, and intraocular lens (IOL) power, between the two swept-source optical coherence tomography (SS-OCT) biometers, the ANTERION (biometer A) and IOLMaster 700 (biometer B). In a prospective observational comparative case series study, we enrolled 198 eyes undergoing cataract surgery. The AL, CCT, ACD, LT, Kf, Ks, Km, astigmatism, WTW, acquired rate, and IOL power were assessed. McNemar tests compared the acquired rate, and the paired sample t-test compared the quantitative measurement results between the groups. Nineteen eyes were excluded owing to missing AL data for either biometer. Finally, data from 179 eyes were analyzed. Between the two devices, no significant difference was found in AL, astigmatism magnitude, J0, and J45, while significant differences existed in CCT, ACD, LT, Kf, Ks, Km, WTW, astigmatism axis, and IOL power; no statistical significance was found in the AL acquired rate (biometer A, 90.9% and biometer B, 93.9%). Approximately 65.4% of eyes demonstrated \u22650.5-D difference in IOL power between the two biometers. In conclusion, the two biometers showed significant differences in all measurements (CCT, ACD, LT, K, WTW, astigmatism axis, and IOL power), except for AL.<\/jats:p>","DOI":"10.3390\/diagnostics12030598","type":"journal-article","created":{"date-parts":[[2022,2,27]],"date-time":"2022-02-27T20:46:17Z","timestamp":1645994777000},"page":"598","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Comparison Study of the Two Biometers Based on Swept-Source Optical Coherence Tomography Technology"],"prefix":"10.3390","volume":"12","author":[{"given":"Jing","family":"Dong","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, First Hospital of Shanxi Medical University, Taiyuan 030001, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jinhan","family":"Yao","sequence":"additional","affiliation":[{"name":"Department of Cataract, Shanxi Eye Hospital Affiliated to Shanxi Medical University, Taiyuan 030002, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuimiao","family":"Chang","sequence":"additional","affiliation":[{"name":"Department of Cataract, Shanxi Eye Hospital Affiliated to Shanxi Medical University, Taiyuan 030002, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8036-7691","authenticated-orcid":false,"given":"Piotr","family":"Kanclerz","sequence":"additional","affiliation":[{"name":"Hygeia Clinic, 80-286 Gda\u0144sk, Poland"},{"name":"Helsinki Retina Research Group, University of Helsinki, 00014 Helsinki, Finland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6237-7773","authenticated-orcid":false,"given":"Ramin","family":"Khoramnia","sequence":"additional","affiliation":[{"name":"The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University of Heidelberg, 69120 Heidelberg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7325-3314","authenticated-orcid":false,"given":"Xiaogang","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Cataract, Shanxi Eye Hospital Affiliated to Shanxi Medical University, Taiyuan 030002, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2022,2,26]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1007\/s40123-018-0122-1","article-title":"Enhanced Penetration for Axial Length Measurement of Eyes with Dense Cataracts Using Swept Source Optical Coherence Tomography: A Consecutive Observational Study","volume":"7","author":"Hirnschall","year":"2018","journal-title":"Ophthalmol. Ther."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"2224","DOI":"10.1016\/j.jcrs.2015.03.019","article-title":"Clinical comparison of a new swept-source optical coherence to-mography-based optical biometer and a time-domain optical coherence tomography-based optical biometer","volume":"41","author":"Srivannaboon","year":"2015","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/j.jcrs.2010.07.023","article-title":"Assessment of a new averaging algorithm to increase the sensitivity of axial eye length measurement with optical biometry in eyes with dense cataract","volume":"37","author":"Hirnschall","year":"2011","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1201","DOI":"10.1136\/bjophthalmol-2015-307779","article-title":"Evaluation and comparison of the new swept source OCT-based IOLMaster 700 with the IOLMaster 500","volume":"100","author":"Akman","year":"2015","journal-title":"Br. J. Ophthalmol."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Kim, K.Y., Choi, G.S., Kang, M.S., and Kim, U.S. (2020). Comparison study of the axial length measured using the new swept-source optical coherence tomography ANTERION and the partial coherence interferometry IOL Master. PLoS ONE, 15.","DOI":"10.1371\/journal.pone.0244590"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"530","DOI":"10.1016\/j.jcrs.2016.02.029","article-title":"Macular disease detection with a swept-source optical coherence to-mography-based biometry device in patients scheduled for cataract surgery","volume":"42","author":"Hirnschall","year":"2016","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1097\/j.jcrs.0000000000000704","article-title":"Comparative analysis of 2 biometers using swept-source OCT technology","volume":"48","author":"Panthier","year":"2021","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1097\/j.jcrs.0000000000000494","article-title":"Repeatability of biometry measured by three devices and its impact on predicted intraocular lens power","volume":"47","author":"Shetty","year":"2021","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1097\/00006324-199706000-00019","article-title":"Power Vectors: An Application of Fourier Analysis to the Description and Statistical Analysis of Refractive Error","volume":"74","author":"Thibos","year":"1997","journal-title":"Optom. Vis. Sci."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1169","DOI":"10.1016\/j.jcrs.2018.07.027","article-title":"Pursuing perfection in intraocular lens calculations: IV. Rethinking astigmatism analysis for intraocular lens-based surgery: Suggested terminology, analysis, and standards for outcome reports","volume":"44","author":"Abulafia","year":"2018","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12886-021-01826-5","article-title":"Comparison of ocular biometric measurements in patients with cataract using three swept-source optical coherence tomography devices","volume":"21","author":"Oh","year":"2021","journal-title":"BMC Ophthalmol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1080\/17434440.2021.1905518","article-title":"Agreement between intraoperative anterior segment spectral-domain OCT and 2 swept-source OCT biometers","volume":"18","year":"2021","journal-title":"Expert Rev. Med Devices"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1097\/j.jcrs.0000000000000483","article-title":"Agreement between 2 swept-source OCT biometers and a Scheimpflug partial coherence interferometer","volume":"47","year":"2021","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1097\/j.jcrs.0000000000000373","article-title":"Comparison of 2 swept-source optical coherence tomography\u2013based biometry devices","volume":"47","author":"Hirnschall","year":"2021","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_15","unstructured":"Pfaeffli, O.A., Weber, A., Hoffer, K.J., Savini, G., Baenninger, P.B., Thiel, M.A., Taroni, L., and M\u00fcller, L. (2021). Agreement of IOL power calcu-lation between IOLMaster 700 and Anterion swept source optical coherence tomography-based biometers. J. Cataract Refract. Surg."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"6557","DOI":"10.1038\/s41598-019-42968-3","article-title":"Ocular biometry and refractive outcomes using two swept-source optical coherence tomography-based biometers with segmental or equivalent refractive indices","volume":"9","author":"Omoto","year":"2019","journal-title":"Sci. Rep."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1016\/j.ophtha.2015.10.002","article-title":"Toric Intraocular Lenses in the Correction of Astigmatism During Cataract Surgery: A Systematic Review and Meta-analysis","volume":"123","author":"Kessel","year":"2016","journal-title":"Ophthalmology"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1016\/j.jcrs.2005.12.139","article-title":"Prediction of the effective postoperative (intraocular lens) anterior chamber depth","volume":"32","author":"Olsen","year":"2006","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"713","DOI":"10.1016\/S0886-3350(13)80339-2","article-title":"An improved universal theoretical formula for intraocular lens power prediction","volume":"19","author":"Barrett","year":"1993","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1097\/ICU.0b013e3282f1c5ad","article-title":"Biometry and intraocular lens power calculation","volume":"19","author":"Lee","year":"2008","journal-title":"Curr. Opin. Ophthalmol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1016\/j.ajo.2016.06.020","article-title":"Agreement Between Swept-Source Optical Biometry and Scheimpflug-based Topography Measurements of Anterior Segment Parameters","volume":"169","year":"2016","journal-title":"Am. J. Ophthalmol."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"e000251","DOI":"10.1136\/bmjophth-2018-000251","article-title":"Comparison of the Kane formula with existing formulas for intraocular lens power selection","volume":"4","author":"Connell","year":"2019","journal-title":"BMJ Open Ophthalmol."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"830","DOI":"10.1016\/j.jcrs.2006.12.025","article-title":"Central and peripheral pachymetry measurements according to age using the Pentacam rotating Scheimpflug camera","volume":"33","author":"Khoramnia","year":"2007","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"7652","DOI":"10.1088\/0031-9155\/61\/21\/7652","article-title":"Spectral phase-based automatic calibration scheme for swept source-based optical coherence tomography systems","volume":"61","author":"Ratheesh","year":"2016","journal-title":"Phys. Med. Biol."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"055601","DOI":"10.1088\/1612-2011\/12\/5\/055601","article-title":"An efficient phase analysis-based wavenumber linearization scheme for swept source optical coherence tomography systems","volume":"12","author":"Meleppat","year":"2015","journal-title":"Laser Phys. Lett."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"2880","DOI":"10.4103\/ijo.IJO_2326_20","article-title":"Phakic intraocular lens: Getting the right size","volume":"68","author":"Deshpande","year":"2020","journal-title":"Indian J. Ophthalmol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"792","DOI":"10.1097\/00003226-200111000-00003","article-title":"Intraocular lens power calculation after laser in situ keratomileusis for myopia and hyperopia: A standardized approach","volume":"20","author":"Feiz","year":"2001","journal-title":"Cornea"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1016\/j.ajo.2011.08.032","article-title":"Choice of Analytic Approach for Eye-Specific Outcomes: One Eye or Two?","volume":"153","author":"Karakosta","year":"2012","journal-title":"Am. J. Ophthalmol."}],"container-title":["Diagnostics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4418\/12\/3\/598\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T22:28:12Z","timestamp":1760135292000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4418\/12\/3\/598"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,26]]},"references-count":28,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2022,3]]}},"alternative-id":["diagnostics12030598"],"URL":"https:\/\/doi.org\/10.3390\/diagnostics12030598","relation":{},"ISSN":["2075-4418"],"issn-type":[{"value":"2075-4418","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,26]]}}}