{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T19:43:34Z","timestamp":1789155814739,"version":"build-2803163510"},"reference-count":56,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2023,2,6]],"date-time":"2023-02-06T00:00:00Z","timestamp":1675641600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Diagnostics"],"abstract":"<jats:p>This short review has the aim of helping the radiologist to identify medical devices when interpreting a chest X-ray, as well as looking for their most commonly detectable complications. Nowadays, many different medical devices are used, often together, especially in critical patients. It is important for the radiologist to know what to look for and to remember the technical factors that need to be considered when checking each device\u2019s positioning.<\/jats:p>","DOI":"10.3390\/diagnostics13040599","type":"journal-article","created":{"date-parts":[[2023,2,7]],"date-time":"2023-02-07T02:28:17Z","timestamp":1675736897000},"page":"599","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Chest X-ray Interpretation: Detecting Devices and Device-Related Complications"],"prefix":"10.3390","volume":"13","author":[{"given":"Marco","family":"Gambato","sequence":"first","affiliation":[{"name":"Institute of Radiology, Department of Medicine (DIMED), University of Padova, 35121 Padua, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicola","family":"Scotti","sequence":"additional","affiliation":[{"name":"Institute of Radiology, Department of Medicine (DIMED), University of Padova, 35121 Padua, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1459-6293","authenticated-orcid":false,"given":"Giacomo","family":"Borsari","sequence":"additional","affiliation":[{"name":"Institute of Radiology, Department of Medicine (DIMED), University of Padova, 35121 Padua, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jacopo","family":"Zambon Bertoja","sequence":"additional","affiliation":[{"name":"Institute of Radiology, Department of Medicine (DIMED), University of Padova, 35121 Padua, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph-Domenico","family":"Gabrieli","sequence":"additional","affiliation":[{"name":"Department of Neuroradiology, University Hospital of Padova, 35121 Padua, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alessandro","family":"De Cassai","sequence":"additional","affiliation":[{"name":"Anesthesia and Intensive Care Unit, University Hospital of Padova, 35121 Padua, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giacomo","family":"Cester","sequence":"additional","affiliation":[{"name":"Department of Neuroradiology, University Hospital of Padova, 35121 Padua, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paolo","family":"Navalesi","sequence":"additional","affiliation":[{"name":"Anesthesia and Intensive Care Unit, Department of Medicine (DIMED), University of Padova, 35121 Padua, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2020-9365","authenticated-orcid":false,"given":"Emilio","family":"Quaia","sequence":"additional","affiliation":[{"name":"Institute of Radiology, Department of Medicine (DIMED), University of Padova, 35121 Padua, Italy"},{"name":"Institute of Radiology, University Hospital of Padova, 35121 Padua, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6491-7027","authenticated-orcid":false,"given":"Francesco","family":"Causin","sequence":"additional","affiliation":[{"name":"Department of Neuroradiology, University Hospital of Padova, 35121 Padua, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2023,2,6]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"546","DOI":"10.1016\/j.acra.2012.12.009","article-title":"Digital Tomosynthesis as a Problem-Solving Imaging Technique to Confirm or Exclude Potential Thoracic Lesions Based on Chest X-ray Radiography","volume":"20","author":"Quaia","year":"2013","journal-title":"Acad. Radiol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1725","DOI":"10.1148\/rg.246045031","article-title":"Medical Devices of the Chest","volume":"24","author":"Hunter","year":"2004","journal-title":"Radiographics"},{"key":"ref_3","first-page":"1729","article-title":"Chest radiographs of cardiac devices (Part 1): Lines, tubes, non-cardiac medical devices and materials","volume":"23","author":"Mathew","year":"2019","journal-title":"S. Afr. J. Radiol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1378","DOI":"10.1111\/pan.14030","article-title":"Routine chest X-ray following ultrasound-guided internal jugular vein catheterization in critically ill children: A prospective observational Study","volume":"30","author":"Weissbach","year":"2020","journal-title":"Pediatr. Anesthesia"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"227","DOI":"10.4103\/0366-6999.173525","article-title":"Malposition of Central Venous Catheter","volume":"129","author":"Wang","year":"2016","journal-title":"Chin. Med. J."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"633","DOI":"10.5152\/dir.2021.20497","article-title":"Chest X-ray in intensive care unit patients: What there is to know about thoracic devices","volume":"27","author":"Baratella","year":"2021","journal-title":"Diagn. Interv. Radiol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"658","DOI":"10.5811\/westjem.2015.7.26248","article-title":"Central Venous Catheter Intravascular Malpositioning: Causes, Prevention, Diagnosis, and Correction","volume":"16","author":"Roldan","year":"2015","journal-title":"West. J. Emerg."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"786","DOI":"10.1259\/bjr.73.871.11089474","article-title":"CT diagnosis of malpositioned chest tubes","volume":"73","author":"Gayer","year":"2000","journal-title":"Br. J. Radiol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"105674","DOI":"10.1016\/j.cmpb.2020.105674","article-title":"Detection of peripherally inserted central catheter (PICC) in chest X-ray images: A multi-task deep learning model","volume":"197","author":"Yu","year":"2020","journal-title":"Comput. Methods Programs Biomed."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1513","DOI":"10.1007\/s00595-014-0893-5","article-title":"Analysis of chest X-ray plain film images of intravenous ports inserted via the superior vena cava","volume":"44","author":"Fu","year":"2014","journal-title":"Surg. Today"},{"key":"ref_11","first-page":"CD003408","article-title":"Pulmonary artery catheters for adult patients in intensive care","volume":"2018","author":"Rajaram","year":"2013","journal-title":"Cochrane Database Syst. Rev."},{"key":"ref_12","first-page":"135","article-title":"Pulmonary artery rupture as a complication of Swan-Ganz catheter application. Diagnosis and endovascular treatment: A single centre\u2019s experience","volume":"12","author":"Henzel","year":"2016","journal-title":"Adv. Interv. Cardiol."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"S23","DOI":"10.4097\/kjae.2013.65.6S.S23","article-title":"Plain endotracheal tube insertion carries greater risk for malpositioning than does reinforced endotracheal tube insertion in females","volume":"65","author":"Han","year":"2013","journal-title":"Korean J. Anesthesiol."},{"key":"ref_14","first-page":"S38","article-title":"Barotrauma and pneumothorax","volume":"7","author":"Ioannidis","year":"2015","journal-title":"J. Thorac. Dis."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/S1010-7940(01)00766-7","article-title":"Esophageal perforation: Life threatening complication of endotracheal intubation","volume":"20","author":"Jougon","year":"2001","journal-title":"Eur. J. Cardio-Thoracic Surg."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"23","DOI":"10.2214\/ajr.154.1.2104719","article-title":"Radiographic detection of esophageal malpositioning of endotracheal tubes","volume":"154","author":"Smith","year":"1990","journal-title":"Am. J. Roentgenol."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"P37","DOI":"10.1186\/cc1736","article-title":"Over-inflation of the tracheal tube cuff: A case for routine monitoring","volume":"6","author":"Kumar","year":"2002","journal-title":"Crit. Care"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1007\/s001010050146","article-title":"Trachealruptur durch zu stark geblockte Tubusmanschette","volume":"44","author":"Striebel","year":"1995","journal-title":"Der Anaesthesist"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"563","DOI":"10.2214\/AJR.10.7226","article-title":"Chest Radiography in the ICU: Part 1, Evaluation of Airway, Enteric, and Pleural Tubes","volume":"198","author":"Godoy","year":"2012","journal-title":"Am. J. Roentgenol."},{"key":"ref_20","first-page":"1425","article-title":"Efficacy and Safety Of Implantable Loop Recorder: Experience Of A Center","volume":"9","author":"Silveira","year":"2016","journal-title":"J. Atr. Fibrillation"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/j.jaccas.2019.06.020","article-title":"The Case of the Migrating Loop Recorder","volume":"1","author":"Hasnie","year":"2019","journal-title":"JACC Case Rep."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1669","DOI":"10.1148\/rg.316115529","article-title":"Radiography of Cardiac Conduction Devices: A Comprehensive Review","volume":"31","author":"Aguilera","year":"2011","journal-title":"Radiographics"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1007\/s11748-016-0671-y","article-title":"Current status of the implantable LVAD","volume":"64","author":"Kadakia","year":"2016","journal-title":"Gen. Thorac. Cardiovasc. Surg."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1016\/j.jchf.2015.03.003","article-title":"Echocardiography and Continuous-Flow Left Ventricular Assist Devices","volume":"3","author":"Cohen","year":"2015","journal-title":"JACC Heart Fail."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1027","DOI":"10.1148\/rg.2018170096","article-title":"Radiographic Review of Current Therapeutic and Monitoring Devices in the Chest","volume":"38","author":"Sigakis","year":"2018","journal-title":"Radiographics"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"903","DOI":"10.1007\/s10741-021-10093-x","article-title":"Complications in children with ventricular assist devices: Systematic review and meta-analyses","volume":"27","author":"George","year":"2021","journal-title":"Heart Fail. Rev."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1016\/j.bpa.2012.03.005","article-title":"Postoperative care and complications after ventricular assist device implantation","volume":"26","author":"Allen","year":"2012","journal-title":"Best Pr. Res. Clin. Anaesthesiol."},{"key":"ref_28","first-page":"118","article-title":"The Impella Device: Historical Background, Clinical Applications and Future Directions","volume":"28","author":"Glazier","year":"2018","journal-title":"Int. J. Angiol."},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Sugimura, Y., Bauer, S., Immohr, M.B., Mehdiani, A., Rellecke, P., Westenfeld, R., Aubin, H., Boeken, U., Lichtenberg, A., and Akhyari, P. (2022). Outcome of Patients Supported by Large Impella Systems After Re-implantation Due to Continued or Recurrent Need of Temporary Mechanical Circulatory Support. Front. Cardiovasc. Med., 9.","DOI":"10.3389\/fcvm.2022.926389"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"21","DOI":"10.4103\/2156-7514.80373","article-title":"Imaging of Mechanical Cardiac Assist Devices","volume":"1","author":"Ginat","year":"2011","journal-title":"J. Clin. Imaging Sci."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/j.xjtc.2021.02.024","article-title":"Hybrid and parallel extracorporeal membrane oxygenation circuits","volume":"8","author":"Shah","year":"2021","journal-title":"JTCVS Tech."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"353","DOI":"10.2214\/ajr.158.2.1729797","article-title":"Thoracic complications of extracorporeal membrane oxygenation: Findings on chest radiographs and sonograms","volume":"158","author":"Gross","year":"1992","journal-title":"Am. J. Roentgenol."},{"key":"ref_33","unstructured":"(2023, January 31). Types of ECMO | Extracorporeal Membrane Oxygenation|ECLS. Available online: https:\/\/www.elso.org\/ecmo-resources\/types-of-ecmo.aspx."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1055\/s-0042-118885","article-title":"Extrakorporale Membranoxygenierung bei Erwachsenen\u2013Varianten, Komplikationen unter Therapie und die Rolle der radiologischen Diagnostik","volume":"189","author":"Beck","year":"2016","journal-title":"Rofo"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"58","DOI":"10.2214\/AJR.04.1672","article-title":"The Role of Imaging during Extracorporeal Membrane Oxygenation in Pediatric Respiratory Failure","volume":"186","author":"Barnacle","year":"2006","journal-title":"Am. J. Roentgenol."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1016\/j.acra.2004.11.027","article-title":"Chest and abdominal CT during extracorporeal membrane oxygenation: Clinical benefits in diagnosis and treatment1","volume":"12","author":"Lidegran","year":"2005","journal-title":"Acad. Radiol."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"151","DOI":"10.2344\/anpr-67-01-02","article-title":"Tracheopulmonary Complications of a Malpositioned Nasogastric Tube","volume":"67","author":"Guthrie","year":"2020","journal-title":"Anesthesia Prog."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"20210432","DOI":"10.1259\/bjr.20210432","article-title":"X-ray checks of NG tube position: A case for guided tube placement","volume":"94","author":"Taylor","year":"2021","journal-title":"Br. J. Radiol."},{"key":"ref_39","unstructured":"Worsfold, P., Townshend, A., and Poole, C. (2005). Encyclopedia of Analytical Science, Elsevier. [2nd ed.]."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"911","DOI":"10.4103\/ija.IJA_400_18","article-title":"Internal jaw thrust for nasogastric tube insertion","volume":"62","author":"Misra","year":"2018","journal-title":"Indian J. Anaesth."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"100879","DOI":"10.1016\/j.inat.2020.100879","article-title":"Intracranial insertion of a nasogastric tube following septoplasty: Case report and literature review","volume":"22","author":"Obiorah","year":"2020","journal-title":"Interdiscip. Neurosurg."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"106","DOI":"10.4046\/trd.2017.0107","article-title":"Chest Tube Drainage of the Pleural Space: A Concise Review for Pulmonologists","volume":"81","author":"Porcel","year":"2018","journal-title":"Tuberc. Respir. Dis."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2018\/8129341","article-title":"Unusual Malposition of a Chest Tube, Intrathoracic but Extrapleural","volume":"2018","author":"Ishaq","year":"2018","journal-title":"Case Rep. Radiol."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"1157","DOI":"10.1002\/ccr3.726","article-title":"Noninvasive management for iatrogenic splenic injury caused by chest tube insertion: A case report","volume":"4","author":"Ohtaka","year":"2016","journal-title":"Clin. Case Rep."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1002\/ccr3.1280","article-title":"Liver injury secondary to chest tube placement: A case report of conservative management and review of literature","volume":"6","author":"Serji","year":"2017","journal-title":"Clin. Case Rep."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2012\/256878","article-title":"Tube Thoracostomy: Complications and Its Management","volume":"2012","author":"Kesieme","year":"2011","journal-title":"Pulm. Med."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"1279","DOI":"10.3171\/2010.6.JNS091541","article-title":"Pulmonary hypertension after ventriculoatrial shunt implantation","volume":"113","author":"Kluge","year":"2010","journal-title":"J. Neurosurg."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"1743","DOI":"10.3348\/kjr.2021.0544","article-title":"Use of Artificial Intelligence-Based Software as Medical Devices for Chest Radiography: A Position Paper from the Korean Society of Thoracic Radiology","volume":"22","author":"Hwang","year":"2021","journal-title":"Korean J. Radiol."},{"key":"ref_49","doi-asserted-by":"crossref","unstructured":"Li, D., Pehrson, L.M., Lauridsen, C.A., T\u00f8ttrup, L., Fraccaro, M., Elliott, D., Zaj\u0105c, H.D., Darkner, S., Carlsen, J.F., and Nielsen, M.B. (2021). The Added Effect of Artificial Intelligence on Physicians\u2019 Performance in Detecting Thoracic Pathologies on CT and Chest X-ray: A Systematic Review. Diagnostics, 11.","DOI":"10.3390\/diagnostics11122206"},{"key":"ref_50","doi-asserted-by":"crossref","unstructured":"Singh, R., Kalra, M.K., Nitiwarangkul, C., Patti, J.A., Homayounieh, F., Padole, A., Rao, P., Putha, P., Muse, V.V., and Sharma, A. (2018). Deep learning in chest radiography: Detection of findings and presence of change. PLoS ONE, 13.","DOI":"10.1371\/journal.pone.0204155"},{"key":"ref_51","doi-asserted-by":"crossref","unstructured":"Irmici, G., C\u00e8, M., Caloro, E., Khenkina, N., Della Pepa, G., Ascenti, V., Martinenghi, C., Papa, S., Oliva, G., and Cellina, M. (2023). Chest X-ray in Emergency Radiology: What Artificial Intelligence Applications Are Available?. Diagnostics, 13.","DOI":"10.3390\/diagnostics13020216"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1007\/s10278-017-0025-z","article-title":"A Deep-Learning System for Fully-Automated Peripherally Inserted Central Catheter (PICC) Tip Detection","volume":"31","author":"Lee","year":"2017","journal-title":"J. Digit. Imaging"},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1177\/0846537120941671","article-title":"Artificial Intelligence Solutions for Analysis of X-ray Images","volume":"72","author":"Adams","year":"2020","journal-title":"Can. Assoc. Radiol. J."},{"key":"ref_54","doi-asserted-by":"crossref","unstructured":"Shen, D., Liu, T., Peters, T.M., Staib, L.H., Essert, C., Zhou, S., Yap, P.-T., and Khan, A. (2019). Proceedings of the Medical Image Computing and Computer Assisted Intervention\u2014MICCAI 2019, Springer International Publishing.","DOI":"10.1007\/978-3-030-32239-7"},{"key":"ref_55","doi-asserted-by":"crossref","unstructured":"Shen, D., Liu, T., Peters, T.M., Staib, L.H., Essert, C., Zhou, S., Yap, P.-T., and Khan, A. (2019). Proceedings of the Medical Image Computing and Computer Assisted Intervention\u2014MICCAI 2019, Springer International Publishing.","DOI":"10.1007\/978-3-030-32239-7"},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"e190082","DOI":"10.1148\/ryai.2020190082","article-title":"Computer-aided Assessment of Catheters and Tubes on Radiographs: How Good Is Artificial Intelligence for Assessment?","volume":"2","author":"Yi","year":"2020","journal-title":"Radiol. Artif. Intell."}],"container-title":["Diagnostics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4418\/13\/4\/599\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T18:25:56Z","timestamp":1760120756000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4418\/13\/4\/599"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,2,6]]},"references-count":56,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2023,2]]}},"alternative-id":["diagnostics13040599"],"URL":"https:\/\/doi.org\/10.3390\/diagnostics13040599","relation":{},"ISSN":["2075-4418"],"issn-type":[{"value":"2075-4418","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,2,6]]}}}