{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,29]],"date-time":"2026-08-29T17:39:03Z","timestamp":1788025143484,"version":"build-2784847793"},"reference-count":47,"publisher":"MDPI AG","issue":"23","license":[{"start":{"date-parts":[[2023,11,21]],"date-time":"2023-11-21T00:00:00Z","timestamp":1700524800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Diagnostics"],"abstract":"<jats:p>Images from 64 patients undergoing an enhanced abdominal-pelvis scan at portal phase in dual-energy CT mode for the diagnosis of colitis or bowel obstruction were retrospectively analyzed. Acquisitions were performed on a third-generation dual-source CT (DSCT) 100\/Sn150 kVp. Mixed images were generated, as well as virtual monoenergetic images (VMIs) at 40\/50\/60\/70 keV. Objective image quality was assessed on VMIs and mixed images by measuring contrast, noise and contrast-to-noise ratio (CNR). Noise, smoothing and overall image quality were subjectively analyzed by two radiologists using Likert scales. For both patient groups, the noise decreased significantly according to the energy level from 40 to 60 keV by \u221247.2 \u00b1 24.0% for bowel obstruction and \u221250.4 \u00b1 18.2% for colitis. It was similar between 60 and 70 keV (p = 0.475 and 0.059, respectively). Noise values were significantly higher in VMIs than in mixed images, except for 70 keV (p = 0.53 and 0.071, respectively). Similar results were observed for contrast values, with a decrease between 40 and 70 keV of \u221256.3 \u00b1 7.9% for bowel obstruction \u221256.2 \u00b1 10.9% for colitis. The maximum CNR value was found at 60 keV compared to other energy levels and mixed images, but there was no significant difference with the other energy levels apart from 70 keV (\u22129.7 \u00b1 9.8%) for bowel obstruction and 40 keV (\u22126.6 \u00b1 8.2%) and 70 keV (\u22125.8 \u00b1 9.2%) for colitis. The VMIs at 60 keV presented higher scores for all criteria for bowel obstruction and colitis, with no significant difference in smoothing score compared to mixed images (p = 0.119 and p = 0.888, respectively).<\/jats:p>","DOI":"10.3390\/diagnostics13233491","type":"journal-article","created":{"date-parts":[[2023,11,21]],"date-time":"2023-11-21T10:24:13Z","timestamp":1700562253000},"page":"3491","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Determining the Optimal Energy Level of Virtual Monoenergetic Images in Dual-Source CT for Diagnosis of Bowel Obstruction and Colitis"],"prefix":"10.3390","volume":"13","author":[{"given":"Loris","family":"Lahuna","sequence":"first","affiliation":[{"name":"Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, N\u00eemes University Hospital, Bd Prof Robert Debr\u00e9, CEDEX 9, 30029 N\u00eemes, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1735-5129","authenticated-orcid":false,"given":"Jo\u00ebl","family":"Greffier","sequence":"additional","affiliation":[{"name":"Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, N\u00eemes University Hospital, Bd Prof Robert Debr\u00e9, CEDEX 9, 30029 N\u00eemes, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6238-102X","authenticated-orcid":false,"given":"Jean","family":"Goupil","sequence":"additional","affiliation":[{"name":"Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, N\u00eemes University Hospital, Bd Prof Robert Debr\u00e9, CEDEX 9, 30029 N\u00eemes, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7816-8178","authenticated-orcid":false,"given":"Julien","family":"Frandon","sequence":"additional","affiliation":[{"name":"Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, N\u00eemes University Hospital, Bd Prof Robert Debr\u00e9, CEDEX 9, 30029 N\u00eemes, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maxime","family":"Pastor","sequence":"additional","affiliation":[{"name":"Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, N\u00eemes University Hospital, Bd Prof Robert Debr\u00e9, CEDEX 9, 30029 N\u00eemes, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fabien","family":"De Oliveira","sequence":"additional","affiliation":[{"name":"Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, N\u00eemes University Hospital, Bd Prof Robert Debr\u00e9, CEDEX 9, 30029 N\u00eemes, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean Paul","family":"Beregi","sequence":"additional","affiliation":[{"name":"Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, N\u00eemes University Hospital, Bd Prof Robert Debr\u00e9, CEDEX 9, 30029 N\u00eemes, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1003-1196","authenticated-orcid":false,"given":"Djamel","family":"Dabli","sequence":"additional","affiliation":[{"name":"Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, N\u00eemes University Hospital, Bd Prof Robert Debr\u00e9, CEDEX 9, 30029 N\u00eemes, France"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2023,11,21]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1016\/j.diii.2015.11.018","article-title":"Applications of dual energy computed tomography in abdominal imaging","volume":"97","author":"Lestra","year":"2016","journal-title":"Diagn. Interv. Imaging"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1148\/radiol.2019182297","article-title":"Review of Clinical Applications for Virtual Monoenergetic Dual-Energy CT","volume":"293","author":"Albrecht","year":"2019","journal-title":"Radiology"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1186\/s13244-021-01082-7","article-title":"Spectral CT of the abdomen: Where are we now?","volume":"12","author":"Adam","year":"2021","journal-title":"Insights Into Imaging"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1186\/s13244-022-01157-z","article-title":"Dual-energy CT with virtual monoenergetic images to improve the visualization of pancreatic supplying arteries: The normal anatomy and variations","volume":"13","author":"Liang","year":"2022","journal-title":"Insights Into Imaging"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1186\/s13244-021-01146-8","article-title":"Utilisation of virtual non-contrast images and virtual mono-energetic images acquired from dual-layer spectral CT for renal cell carcinoma: Image quality and radiation dose","volume":"13","author":"Zhang","year":"2022","journal-title":"Insights Into Imaging"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1148\/rg.2019180087","article-title":"Dual-Energy CT in Evaluation of the Acute Abdomen","volume":"39","author":"Murray","year":"2019","journal-title":"RadioGraphics"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"E881","DOI":"10.1002\/mp.14157","article-title":"Principles and applications of multienergy CT: Report of AAPM Task Group 291","volume":"47","author":"McCollough","year":"2020","journal-title":"Med. Phys."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1016\/j.diii.2022.11.003","article-title":"Spectral CT imaging: Technical principles of dual-energy CT and multi-energy photon-counting CT","volume":"104","author":"Greffier","year":"2023","journal-title":"Diagn. Interv. Imaging"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1016\/j.ejmp.2021.07.008","article-title":"Optimization of image quality and accuracy of low iodine concentration quantification as function of kVp pairs for abdominal imaging using dual-source CT: A phantom study","volume":"88","author":"Dabli","year":"2021","journal-title":"Phys. Medica"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1002\/acm2.13369","article-title":"Impact of four kVp combinations available in a dual-source CT on the spectral performance of abdominal imaging: A task-based image quality assessment on phantom data","volume":"22","author":"Greffier","year":"2021","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"109387","DOI":"10.1016\/j.ejrad.2020.109387","article-title":"Virtual unenhanced imaging of the liver derived from 160-mm rapid-switching dual-energy CT (rsDECT): Comparison of the accuracy of attenuation values and solid liver lesion conspicuity with native unenhanced images","volume":"133","author":"Lacroix","year":"2020","journal-title":"Eur. J. Radiol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1258\/ar.2012.110661","article-title":"Virtual non-contrast dual-energy CT compared to single-energy CT of the urinary tract: A prospective study","volume":"53","author":"Lundin","year":"2012","journal-title":"Acta Radiol."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"702","DOI":"10.1007\/s00261-016-1036-9","article-title":"Spectral detector CT-derived virtual non-contrast images: Comparison of attenuation values with unenhanced CT","volume":"42","author":"Ananthakrishnan","year":"2017","journal-title":"Abdom. Radiol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1053\/j.sult.2022.03.004","article-title":"Virtual Non-contrast Imaging in The Abdomen and The Pelvis: An Overview","volume":"43","author":"Virarkar","year":"2022","journal-title":"Semin. Ultrasound CT MRI"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1097\/RLI.0000000000000387","article-title":"Virtual Monoenergetic Imaging and Iodine Perfusion Maps Improve Diagnostic Accuracy of Dual-Energy Computed Tomography Pulmonary Angiography with Suboptimal Contrast Attenuation","volume":"52","author":"Leithner","year":"2017","journal-title":"Investig. Radiol."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"2493","DOI":"10.1007\/s00330-015-3627-1","article-title":"Assessment of an Advanced Monoenergetic Reconstruction Technique in Dual-Energy Computed Tomography of Head and Neck Cancer","volume":"25","author":"Albrecht","year":"2015","journal-title":"Eur. Radiol."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"20201276","DOI":"10.1259\/bjr.20201276","article-title":"Advantages and disadvantages of single-source dual-energy whole-body CT angiography with 50% reduced iodine dose at 40 keV reconstruction","volume":"94","author":"Noda","year":"2021","journal-title":"Br. J. Radiol."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"467","DOI":"10.2214\/AJR.18.19935","article-title":"Virtual Monochromatic Dual-Energy Aortoiliac CT Angiography with Reduced Iodine Dose: A Prospective Randomized Study","volume":"212","author":"Patino","year":"2019","journal-title":"Am. J. Roentgenol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1148\/radiol.11100978","article-title":"Virtual Monochromatic Spectral Imaging with Fast Kilovoltage Switching: Improved Image Quality as Compared with That Obtained with Conventional 120-kVp CT","volume":"259","author":"Matsumoto","year":"2011","journal-title":"Radiology"},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Winkelmann, M.T., Hagen, F., Artzner, K., Bongers, M.N., and Artzner, C. (2022). Dual-Energy CT for Accurate Discrimination of Intraperitoneal Hematoma and Intestinal Structures. Diagnostics, 12.","DOI":"10.3390\/diagnostics12102542"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"364","DOI":"10.5152\/dir.2022.21107","article-title":"Effect of acquisition techniques, latest kernels, and advanced monoenergetic post-processing for stent visualization with third-generation dual-source CT","volume":"28","author":"Artzner","year":"2022","journal-title":"Diagn. Interv. Radiol."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1016\/j.diii.2021.03.002","article-title":"Impact of dose reduction and the use of an advanced model-based iterative reconstruction algorithm on spectral performance of a dual-source CT system: A task-based image quality assessment","volume":"102","author":"Greffier","year":"2021","journal-title":"Diagn. Interv. Imaging"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.diii.2021.08.004","article-title":"Optimization of image quality and accuracy of low iodine concentration quantification as function of dose level and reconstruction algorithm for abdominal imaging using dual-source CT: A phantom study","volume":"103","author":"Dabli","year":"2022","journal-title":"Diagn. Interv. Imaging"},{"key":"ref_24","first-page":"1403957","article-title":"Image Quality and Dose Comparison of Single-Energy CT (SECT) and Dual-Energy CT (DECT)","volume":"2020","author":"Shayan","year":"2020","journal-title":"Radiol. Res. Pract."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"5324","DOI":"10.1007\/s00330-020-07671-2","article-title":"Performance of four dual-energy CT platforms for abdominal imaging: A task-based image quality assessment based on phantom data","volume":"31","author":"Greffier","year":"2021","journal-title":"Eur. Radiol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1148\/radiol.2017170896","article-title":"Intermanufacturer Comparison of Dual-Energy CT Iodine Quantification and Monochromatic Attenuation: A Phantom Study","volume":"287","author":"Jacobsen","year":"2018","journal-title":"Radiology"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"2745","DOI":"10.1007\/s00330-017-5238-5","article-title":"Dual-energy CT: A phantom comparison of different platforms for abdominal imaging","volume":"28","author":"Sellerer","year":"2018","journal-title":"Eur. Radiol."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1186\/s41747-021-00224-2","article-title":"Quantitative benchmarking of iodine imaging for two CT spectral imaging technologies: A phantom study","volume":"5","author":"Harsaker","year":"2021","journal-title":"Eur. Radiol. Exp."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1149","DOI":"10.21037\/qims-21-708","article-title":"Comparison of virtual monoenergetic imaging between a rapid kilovoltage switching dual-energy computed tomography with deep-learning and four dual-energy CTs with iterative reconstruction","volume":"12","author":"Greffier","year":"2022","journal-title":"Quant. Imaging Med. Surg."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s41747-022-00314-9","article-title":"Comparison of image quality of two versions of deep-learning image reconstruction algorithm on a rapid kV-switching CT: A phantom study","volume":"7","author":"Dabli","year":"2023","journal-title":"Eur. Radiol. Exp."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"2233","DOI":"10.1002\/mp.15558","article-title":"Phantom task-based image quality assessment of three generations of rapid kV-switching dual-energy CT systems on virtual monoenergetic images","volume":"49","author":"Greffier","year":"2022","journal-title":"Med. Phys."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"564","DOI":"10.2214\/AJR.18.19554","article-title":"Dual-Energy CT Iodine Mapping and 40-keV Monoenergetic Applications in the Diagnosis of Acute Bowel Ischemia","volume":"211","author":"Lourenco","year":"2018","journal-title":"Am. J. Roentgenol."},{"key":"ref_33","first-page":"20180546","article-title":"Dual energy computed tomography virtual monoenergetic imaging: Technique and clinical applications","volume":"92","author":"Cicero","year":"2019","journal-title":"Br. J. Radiol."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"1977","DOI":"10.1007\/s00330-017-5151-y","article-title":"Can dual-energy CT replace perfusion CT for the functional evaluation of advanced hepatocellular carcinoma?","volume":"28","author":"Pigneur","year":"2018","journal-title":"Eur. Radiol."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"2066","DOI":"10.1007\/s00261-017-1411-1","article-title":"Assessment of arterially hyper-enhancing liver lesions using virtual monoenergetic images from spectral detector CT: Phantom and patient experience","volume":"43","author":"Hokamp","year":"2018","journal-title":"Abdom. Radiol."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"1230","DOI":"10.1007\/s00261-014-0274-y","article-title":"Multireader evaluation of lesion conspicuity in small pancreatic adenocarcinomas: Complimentary value of iodine material density and low keV simulated monoenergetic images using multiphasic rapid kVp-switching dual energy CT","volume":"40","author":"McNamara","year":"2015","journal-title":"Abdom. Imaging"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"W205","DOI":"10.2214\/AJR.17.18641","article-title":"Energy-Specific Optimization of Attenuation Thresholds for Low-Energy Virtual Monoenergetic Images in Renal Lesion Evaluation","volume":"210","author":"Patel","year":"2018","journal-title":"Am. J. Roentgenol."},{"key":"ref_38","first-page":"710","article-title":"Minimal invasive surgery for multiple adhesive small bowel obstruction: Results of a comparative multicenter study","volume":"89","author":"Pedraza","year":"2021","journal-title":"Cirug\u00eda Y Cir."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"718","DOI":"10.1007\/s00261-016-1011-5","article-title":"Noise-optimized virtual monoenergetic dual-energy computed tomography: Optimization of kiloelectron volt settings in patients with gastrointestinal stromal tumors","volume":"42","author":"Martin","year":"2017","journal-title":"Abdom. Radiol."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"950","DOI":"10.1016\/j.ejrad.2016.02.019","article-title":"Virtual monoenergetic reconstruction of contrast-enhanced dual energy CT at 70keV maximizes mural enhancement in acute small bowel obstruction","volume":"85","author":"Darras","year":"2016","journal-title":"Eur. J. Radiol."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1148\/radiol.14140875","article-title":"Early Small-Bowel Ischemia: Dual-Energy CT Improves Conspicuity Compared with Conventional CT in a Swine Model","volume":"275","author":"Potretzke","year":"2015","journal-title":"Radiology"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"2525","DOI":"10.1007\/s00330-017-5215-z","article-title":"Virtual monoenergetic dual-layer, dual-energy CT enterography: Optimization of keV settings and its added value for Crohn\u2019s disease","volume":"28","author":"Lee","year":"2018","journal-title":"Eur. Radiol."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"480","DOI":"10.1148\/radiol.2020192234","article-title":"Adhesive Small Bowel Obstruction: Predictive Radiology to Improve Patient Management","volume":"296","author":"Zins","year":"2020","journal-title":"Radiology"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1002\/acm2.12223","article-title":"Evaluation of AAPM Reports 204 and 220: Estimation of effective diameter, water-equivalent diameter, and ellipticity ratios for chest, abdomen, pelvis, and head CT scans","volume":"19","author":"Burton","year":"2018","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1016\/j.pharma.2020.06.001","article-title":"Biostatistiques m\u00e9dicales avec GMRC Shiny Stats\u2014Un outil de formation par la pratique","volume":"78","author":"Fabacher","year":"2020","journal-title":"Ann. Pharm. Fran\u00e7aises"},{"key":"ref_46","doi-asserted-by":"crossref","unstructured":"Tao, S., Rajendran, K., Zhou, W., Fletcher, J.G., McCollough, C.H., and Leng, S. (2019). Improving iodine contrast to noise ratio using virtual monoenergetic imaging and prior-knowledge-aware iterative denoising (mono-PKAID). Phys. Med. Biol., 64.","DOI":"10.1088\/1361-6560\/ab17fa"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1097\/RLI.0000000000000109","article-title":"The Importance of Spectral Separation: An Assessment of Dual-Energy Spectral Separation for Quantitative Ability and Dose Efficiency","volume":"50","author":"Krauss","year":"2015","journal-title":"Investig. Radiol."}],"container-title":["Diagnostics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4418\/13\/23\/3491\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T21:25:52Z","timestamp":1760131552000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4418\/13\/23\/3491"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,21]]},"references-count":47,"journal-issue":{"issue":"23","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["diagnostics13233491"],"URL":"https:\/\/doi.org\/10.3390\/diagnostics13233491","relation":{},"ISSN":["2075-4418"],"issn-type":[{"value":"2075-4418","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11,21]]}}}