{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T21:01:29Z","timestamp":1791234089968,"version":"4.1.0"},"reference-count":31,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2023,12,21]],"date-time":"2023-12-21T00:00:00Z","timestamp":1703116800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Diagnostics"],"abstract":"<jats:p>The use of handheld point-of-care ultrasound (HH-POCUS) platforms is rapidly increasing, but the diagnostic performance of HH-POCUS in the emergency department (ED) has not been well-studied. For a period of one year, only a HH-POCUS system that uses a non-piezoelectric array (Butterfly iQ+\u2122) was available for clinical POCUS examinations in our ED. We performed a retrospective observational study of patients who underwent cardiac, thoracic, renal, biliary, or lower extremity venous (DVT) examinations from November 2021\u2013November 2022 and calculated performance characteristics of HH-POCUS relative to radiology imaging. A total of 381 HH-POCUS studies were evaluated. Cardiac image quality was significantly lower than lung (p = 0.002). Over half of the studies (213\/381) had imaging available for comparison, and HH-POCUS identified 86.5% (32\/37, (95%CI) 70.4\u201394.9) of prespecified emergent diagnoses, including acute cholecystitis, severely reduced left ventricular ejection fraction, pericardial effusion or tamponade, moderate or larger pleural effusion, pneumothorax, moderate or larger hydronephrosis, and DVT. For less emergent diagnoses, 84.3% (43\/51, (95%CI) 70.9\u201392.5) were identified. Overall, HH-POCUS using a non-piezoelectric array showed modest real-world performance in the ED for cardiac, thoracic, renal, biliary, and DVT examinations. HH-POCUS may be inadequate to rule out some common ED diagnoses, but had good specificity for certain conditions such as pericardial effusion.<\/jats:p>","DOI":"10.3390\/diagnostics14010017","type":"journal-article","created":{"date-parts":[[2023,12,21]],"date-time":"2023-12-21T05:36:12Z","timestamp":1703136972000},"page":"17","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["The Performance Characteristics of Handheld, Non-Piezoelectric Point-of-Care Ultrasound (POCUS) in the Emergency Department"],"prefix":"10.3390","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6888-0137","authenticated-orcid":false,"given":"Brandon Michael","family":"Wubben","sequence":"first","affiliation":[{"name":"Department of Emergency Medicine, University of Iowa, 200 Hawkins Drive, Iowa City, IA 52242, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3530-7788","authenticated-orcid":false,"given":"Hae In","family":"Yun","sequence":"additional","affiliation":[{"name":"Carver College of Medicine, University of Iowa, 375 Newton Road, Iowa City, IA 52242, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2023,12,21]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1007\/s40138-021-00229-6","article-title":"The use of handheld ultrasound devices in emergency medicine","volume":"9","author":"Malik","year":"2021","journal-title":"Curr. Emerg. Hosp. Med. Rep."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1826","DOI":"10.1136\/heartjnl-2021-319561","article-title":"Diagnostic accuracy of handheld cardiac ultrasound device for assessment of left ventricular structure and function: Systematic review and meta-analysis","volume":"107","author":"Jenkins","year":"2021","journal-title":"Heart"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Corte, G., Bayat, S., Tascilar, K., Valor-Mendez, L., Schuster, L., Knitza, J., Fagni, F., Schett, G., Kleyer, A., and Simon, D. (2021). Performance of a handheld ultrasound device to assess articular and periarticular pathologies in patients with inflammatory arthritis. Diagnostics, 11.","DOI":"10.3390\/diagnostics11071139"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"376","DOI":"10.5144\/0256-4947.2021.376","article-title":"Abdominal aorta measurements by a handheld ultrasound device compared with a conventional cart-based ultrasound machine","volume":"41","author":"Alfuraih","year":"2021","journal-title":"Ann. Saudi Med."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"607","DOI":"10.4187\/respcare.09239","article-title":"Portable handheld point-of-care ultrasound for detecting unrecognized esophageal intubations","volume":"67","author":"Gibson","year":"2022","journal-title":"Respir. Care"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1155","DOI":"10.1016\/j.chest.2020.09.083","article-title":"Use of handheld point-of-care ultrasound in emergency airway management","volume":"159","author":"Austin","year":"2021","journal-title":"Chest"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1017\/S1049023X22000644","article-title":"The utilization of handheld ultrasound devices in a prehospital setting","volume":"37","author":"Ienghong","year":"2022","journal-title":"Prehosp. Disaster Med."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1016\/j.jemermed.2021.07.064","article-title":"Comparing time to diagnosis and treatment of patients with ruptured ectopic pregnancy based on type of ultrasound performed: A retrospective inquiry","volume":"62","author":"Urquhart","year":"2022","journal-title":"J. Emerg. Med."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/j.ajem.2022.08.008","article-title":"ED point-of-care ultrasonography is associated with earlier drainage of pericardial effusion: A retrospective cohort study","volume":"60","author":"Hoch","year":"2022","journal-title":"Am. J. Emerg. Med."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"(2018). Appropriate use criteria for handheld\/pocket ultrasound devices. Ann. Emerg. Med., 72, e31\u2013e33.","DOI":"10.1016\/j.annemergmed.2018.07.042"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1265","DOI":"10.1016\/j.ajem.2018.03.077","article-title":"Assessment of five different probes for lung ultrasound in critically ill patients: A pilot study","volume":"36","author":"Bobbia","year":"2018","journal-title":"Am. J. Emerg. Med."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/j.ultrasmedbio.2020.09.014","article-title":"Portable pocket-sized ultrasound scanner for the evaluation of lung involvement in Coronavirus Disease 2019 patients","volume":"47","author":"Bennett","year":"2021","journal-title":"Ultrasound Med. Biol."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"R82","DOI":"10.1186\/cc11340","article-title":"Evaluation of a new pocket echoscopic device for focused cardiac ultrasonography in an emergency setting","volume":"16","author":"Biais","year":"2012","journal-title":"Crit. Care"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"552.e1","DOI":"10.1016\/j.ajog.2021.11.031","article-title":"Incorporating personal-device-based point-of-care ultrasound into obstetric care: A validation study","volume":"226","author":"Leggett","year":"2022","journal-title":"Am. J. Obstet. Gynecol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1186\/s13089-020-00200-8","article-title":"Evaluation of a novel handheld point-of-care ultrasound device in an African emergency department","volume":"12","author":"Burleson","year":"2020","journal-title":"Ultrasound J."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1016\/j.jbi.2008.08.010","article-title":"Research electronic data capture (REDCap)--a metadata-driven methodology and workflow process for providing translational research informatics support","volume":"42","author":"Harris","year":"2009","journal-title":"J. Biomed. Inform."},{"key":"ref_17","first-page":"665","article-title":"Feasibility and reliability of point-of-care pocket-sized echocardiography","volume":"12","author":"Andersen","year":"2011","journal-title":"Eur. J. Echocardiogr."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1016\/j.ahj.2003.10.010","article-title":"Feasibility of point-of-care echocardiography by internal medicine house staff","volume":"147","author":"Alexander","year":"2004","journal-title":"Am. Heart J."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1121","DOI":"10.1007\/s11739-018-1901-3","article-title":"Pocket-size ultrasound device in cholelithiasis: Diagnostic accuracy and efficacy of short-term training","volume":"13","author":"Altieri","year":"2018","journal-title":"Intern. Emerg. Med."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1262","DOI":"10.1016\/j.ajem.2018.03.076","article-title":"Compression with a pocket-sized ultrasound device to diagnose proximal deep vein thrombosis","volume":"36","author":"Pujol","year":"2018","journal-title":"Am. J. Emerg. Med."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1007\/s10396-018-0881-2","article-title":"Assessment of the renal collecting system using a pocket-sized ultrasound device","volume":"45","author":"Kameda","year":"2018","journal-title":"J. Med. Ultrason."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1195","DOI":"10.7863\/ultra.16.05077","article-title":"Feasibility and diagnostic accuracy of point-of-care abdominal sonography by pocket-sized imaging devices, performed by medical residents","volume":"36","author":"Kjesbu","year":"2017","journal-title":"J. Ultrasound Med."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"684","DOI":"10.1111\/acem.13388","article-title":"The accuracy and prognostic value of point-of-care ultrasound for nephrolithiasis in the emergency department: A systematic review and meta-analysis","volume":"25","author":"Wong","year":"2018","journal-title":"Acad. Emerg. Med."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"56","DOI":"10.3109\/14017431.2015.1009383","article-title":"Focused ultrasound of the pleural cavities and the pericardium by nurses after cardiac surgery","volume":"49","author":"Graven","year":"2015","journal-title":"Scand. Cardiovasc."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1177\/1474515114547651","article-title":"Feasibility and reliability of pocket-size ultrasound examinations of the pleural cavities and vena cava inferior performed by nurses in an outpatient heart failure clinic","volume":"14","author":"Dalen","year":"2015","journal-title":"Eur. J. Cardiovasc. Nurs."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"596","DOI":"10.1093\/icvts\/ivs223","article-title":"Incremental value of pocket-sized imaging device for bedside diagnosis of unilateral pleural effusions and ultrasound-guided thoracentesis","volume":"15","author":"Lisi","year":"2012","journal-title":"Interact. Cardiovasc. Thorac. Surg."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1016\/j.ajem.2006.02.013","article-title":"Bedside lung ultrasound in the assessment of alveolar-interstitial syndrome","volume":"24","author":"Volpicelli","year":"2006","journal-title":"Am. J. Emerg. Med."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"3139","DOI":"10.1053\/j.jvca.2020.07.004","article-title":"Handheld point-of-care ultrasound probes: The new generation of POCUS","volume":"34","author":"Baribeau","year":"2020","journal-title":"J. Cardiothorac. Vasc. Anesth."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1186\/s13089-022-00274-6","article-title":"Comparison of four handheld point-of-care ultrasound devices by expert users","volume":"14","author":"Le","year":"2022","journal-title":"Ultrasound J."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1017\/S1049023X21001357","article-title":"Point-of-care ultrasound use by EMS providers in out-of-hospital cardiac arrest","volume":"37","author":"Kreiser","year":"2022","journal-title":"Prehosp. Disaster Med."},{"key":"ref_31","first-page":"265","article-title":"Wireless point-of-care ultrasound in a multiplace hyperbaric chamber","volume":"50","author":"Tanaka","year":"2023","journal-title":"Undersea Hyperb. Med."}],"container-title":["Diagnostics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4418\/14\/1\/17\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T21:39:29Z","timestamp":1760132369000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4418\/14\/1\/17"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12,21]]},"references-count":31,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,1]]}},"alternative-id":["diagnostics14010017"],"URL":"https:\/\/doi.org\/10.3390\/diagnostics14010017","relation":{},"ISSN":["2075-4418"],"issn-type":[{"value":"2075-4418","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,12,21]]}}}