{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T16:23:10Z","timestamp":1772814190441,"version":"3.50.1"},"reference-count":17,"publisher":"MDPI AG","issue":"22","license":[{"start":{"date-parts":[[2024,11,8]],"date-time":"2024-11-08T00:00:00Z","timestamp":1731024000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Diagnostics"],"abstract":"<jats:p>Background: Transseptal puncture (TSP) is a critical step in electrophysiological (EP) procedures, as a misdirected TSP can result in life-threatening complications. Although TSP is predominantly performed under fluoroscopic guidance in EP procedures, transesophageal echocardiography (TEE) offers more precision and certainty in the localization of the transseptal needle at the interatrial septum. Despite the widespread use of TSP, evidence supporting the added value of TEE-guided TSP in EP procedures remains limited. This study evaluates the impact of additional TEE guidance on TSP-associated complications during EP procedures. Methods: This study enrolled patients who underwent left atrial or left ventricular procedures with TSP, performed either without (fluoroscopy group) or with additional TEE guidance (TEE group), at the University Heart Center Ulm, Germany. Results: A total of 932 patients were included: 443 in the TEE group (mean age 68.1 \u00b1 11.8 years, 40.6% female) and 489 in the fluoroscopy group (mean age 68.8 \u00b1 11.0 years, 38.2% female). The mean number of transseptal accesses per patient was 1.18 \u00b1 0.38 in the TEE group and 1.14 \u00b1 0.34 in the fluoroscopy group (p = 0.101). Pericardial tamponade occurred significantly less in the TEE group (0.5%) than in the fluoroscopy group (1.8%; p = 0.046). Logistic regression revealed a 91.8% lower risk of pericardial tamponade with TEE-guided TSP compared to fluoroscopy guidance alone. The overall TEE complication rate was low (0.9%). Conclusions: TEE guidance during TSP significantly reduces the risk of pericardial tamponade in EP procedures, indicating that TSP should be performed with additional sonographic guidance to increase patient safety.<\/jats:p>","DOI":"10.3390\/diagnostics14222495","type":"journal-article","created":{"date-parts":[[2024,11,8]],"date-time":"2024-11-08T04:02:54Z","timestamp":1731038574000},"page":"2495","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Transesophageal Echocardiography-Guided Transseptal Puncture Reduces Pericardial Tamponade in Electrophysiological Procedures"],"prefix":"10.3390","volume":"14","author":[{"given":"Yannick","family":"Teumer","sequence":"first","affiliation":[{"name":"Ulm University Heart Center, Ulm University, Albert-Einstein-Allee 23, 89081 Ulm, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel","family":"Eckart","sequence":"additional","affiliation":[{"name":"Ulm University Heart Center, Ulm University, Albert-Einstein-Allee 23, 89081 Ulm, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lyuboslav","family":"Katov","sequence":"additional","affiliation":[{"name":"Ulm University Heart Center, Ulm University, Albert-Einstein-Allee 23, 89081 Ulm, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0649-7364","authenticated-orcid":false,"given":"Dominik","family":"Felbel","sequence":"additional","affiliation":[{"name":"Ulm University Heart Center, Ulm University, Albert-Einstein-Allee 23, 89081 Ulm, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carlo","family":"Bothner","sequence":"additional","affiliation":[{"name":"Ulm University Heart Center, Ulm University, Albert-Einstein-Allee 23, 89081 Ulm, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wolfgang","family":"Rottbauer","sequence":"additional","affiliation":[{"name":"Ulm University Heart Center, Ulm University, Albert-Einstein-Allee 23, 89081 Ulm, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5777-2998","authenticated-orcid":false,"given":"Karolina","family":"Weinmann-Emhardt","sequence":"additional","affiliation":[{"name":"Ulm University Heart Center, Ulm University, Albert-Einstein-Allee 23, 89081 Ulm, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2024,11,8]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1798","DOI":"10.1016\/j.jacc.2009.02.022","article-title":"Prevalence and Causes of Fatal Outcome in Catheter Ablation of Atrial Fibrillation","volume":"53","author":"Cappato","year":"2009","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"euae043","DOI":"10.1093\/europace\/euae043","article-title":"2024 European Heart Rhythm Association\/Heart Rhythm Society\/Asia Pacific Heart Rhythm Society\/Latin American Heart Rhythm Society Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation","volume":"26","author":"Tzeis","year":"2024","journal-title":"Europace"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"euad378","DOI":"10.1093\/europace\/euad378","article-title":"Prevention and Treatment of Pericardial Tamponade in the Electrophysiology Laboratory: A European Heart Rhythm Association Survey","volume":"26","author":"Metzner","year":"2023","journal-title":"Europace"},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Katov, L., Teumer, Y., Lederbogen, K., Melnic, R., Rottbauer, W., Bothner, C., and Weinmann-Emhardt, K. (2024). Transesophageal Echocardiography Improves Precision in Transseptal Puncture Compared to Fluoroscopy in Left Atrial Electrophysiological Procedures. J. Clin. Med., 13.","DOI":"10.3390\/jcm13092476"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"636","DOI":"10.1016\/j.jacep.2020.01.011","article-title":"Predictors of Cardiac Perforation with Catheter Ablation of Atrial Fibrillation","volume":"6","author":"Friedman","year":"2020","journal-title":"JACC Clin. Electrophysiol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"305","DOI":"10.2174\/1573403X13666170927122036","article-title":"Transseptal Access to the Left Atrium: Tips and Tricks to Keep It Safe Derived from Single Operator Experience and Review of the Literature","volume":"13","author":"Manolis","year":"2017","journal-title":"Curr. Cardiol. Rev."},{"key":"ref_7","first-page":"2023","article-title":"Safety of Fluoroscopy-Guided Transseptal Approach for Ablation of Left-Sided Arrhythmias","volume":"19","author":"Matoshvili","year":"2017","journal-title":"EP Eur."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1007\/s10840-020-00844-5","article-title":"Does the Use of Intracardiac Echocardiography during Atrial Fibrillation Catheter Ablation Improve Outcomes and Cost? A Nationwide 14-Year Analysis from 2001 to 2014","volume":"61","author":"Isath","year":"2021","journal-title":"J. Interv. Card. Electrophysiol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1093\/europace\/eur366","article-title":"Added Value of Transoesophageal Echocardiography during Transseptal Puncture Performed by Inexperienced Operators","volume":"14","author":"Bayrak","year":"2012","journal-title":"Europace"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1161\/CIRCEP.109.859116","article-title":"Updated Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial Fibrillation","volume":"3","author":"Cappato","year":"2010","journal-title":"Circ. Arrhythm. Electrophysiol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1016\/j.joa.2015.12.005","article-title":"Impact of Transesophageal Echocardiography during Transseptal Puncture on Atrial Fibrillation Ablation","volume":"32","author":"Erden","year":"2016","journal-title":"J. Arrhythmia"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/j.ijcard.2022.01.011","article-title":"Transseptal Puncture: Review of Anatomy, Techniques, Complications and Challenges, a Critical View","volume":"351","author":"Almendarez","year":"2022","journal-title":"Int. J. Cardiol."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"720","DOI":"10.4244\/EIJ-D-20-00454","article-title":"Transseptal Puncture: Procedural Guidance, Challenging Situations and Management of Complications","volume":"17","author":"Russo","year":"2021","journal-title":"EuroIntervention"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/j.ahj.2019.11.018","article-title":"Transesophageal Echocardiography Complications Associated with Interventional Cardiology Procedures","volume":"221","author":"Beaudoin","year":"2020","journal-title":"Am. Heart J."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1871","DOI":"10.1136\/heartjnl-2014-306067","article-title":"Periprocedural Imaging and Outcomes after Catheter Ablation of Atrial Fibrillation","volume":"100","author":"Steinberg","year":"2014","journal-title":"Heart"},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Teumer, Y., Eckart, D., Katov, L., Graf, M., Bothner, C., Rottbauer, W., and Weinmann-Emhardt, K. (2024). Ultrasound-Guided Venous Puncture Reduces Groin Complications in Electrophysiological Procedures. Biomedicines, 12.","DOI":"10.3390\/biomedicines12102375"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"880","DOI":"10.1016\/j.jacep.2020.04.037","article-title":"Intracardiac Versus Transesophageal Echocardiography","volume":"6","author":"Penela","year":"2020","journal-title":"JACC Clin. Electrophysiol."}],"container-title":["Diagnostics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4418\/14\/22\/2495\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T16:28:25Z","timestamp":1760113705000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4418\/14\/22\/2495"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,8]]},"references-count":17,"journal-issue":{"issue":"22","published-online":{"date-parts":[[2024,11]]}},"alternative-id":["diagnostics14222495"],"URL":"https:\/\/doi.org\/10.3390\/diagnostics14222495","relation":{},"ISSN":["2075-4418"],"issn-type":[{"value":"2075-4418","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,11,8]]}}}