{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T16:57:51Z","timestamp":1785776271417,"version":"3.56.0"},"reference-count":38,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2025,2,13]],"date-time":"2025-02-13T00:00:00Z","timestamp":1739404800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Diagnostics"],"abstract":"<jats:p>Background\/Objectives: Robot-assisted bronchoscopy (RAB) is a novel platform for sampling peripheral pulmonary nodules (PPNs). To further clarify the role robot-assisted platforms have in diagnosing PPNs, we performed a review of the recent literature. Methods: A systematic review was performed in Medline from 2019 to 2024 using the search terms \u201crobotic bronchoscopy\u201d, \u201cdiagnostic yield\u201d, \u201csensitivity\u201d, and \u201cpositive predictive value\u201d, alone and in combination. Studies that focused on earlier electromagnetic bronchoscopies were excluded. The patient demographic information, nodule characteristics, intra-procedure imaging modality, biopsy methods, diagnostic yield, sensitivity for malignancy, and adverse outcomes were analyzed. A total of 22 studies were available for the analyses. Results: The diagnostic yield was variable and ranged from 69 to 93%, with a median of 86%. The sensitivity ranged from 69% to 91.7%, with a median of 85%. The effect of the nodule size on the diagnostic yield was variable across the literature. Obtaining an eccentric or concentric view on a radial endobronchial ultrasound (rEBUS) was associated with a higher diagnostic yield than obtaining no view. A nodule appearance on CT imaging and the location were not definitively associated with a higher diagnostic yield. Fine needle aspiration usage ranged from 93.5 to 100%, with a median of 96.95%, while the use of biopsy forceps ranged from 2.7 to 96%, with a median of 69.9%. The most common complication was a pneumothorax, which occurred in 1\u20135.7% of cases, with a median of 1.6%. Conclusions: Robot-assisted transbronchial biopsies produce diagnostic yields that approach those of transthoracic needle aspirations. The nodule location and appearance may not affect the diagnostic yield. Obtaining a concentric or eccentric view on rEBUS is likely associated with an increased diagnostic yield. Additional prospective studies would better inform practitioners as this technology becomes more widespread.<\/jats:p>","DOI":"10.3390\/diagnostics15040450","type":"journal-article","created":{"date-parts":[[2025,2,13]],"date-time":"2025-02-13T05:10:22Z","timestamp":1739423422000},"page":"450","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Outcomes of Robot-Assisted Transbronchial Biopsies of Pulmonary Nodules: A Review"],"prefix":"10.3390","volume":"15","author":[{"given":"Peter A.","family":"Ebeling","sequence":"first","affiliation":[{"name":"Interventional Pulmonary Program, Section of Pulmonary, Critical Care and Sleep Medicine, University of Oklahoma, Oklahoma City, OK 73104, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9427-6504","authenticated-orcid":false,"given":"Salim","family":"Daouk","sequence":"additional","affiliation":[{"name":"Interventional Pulmonary Program, Section of Pulmonary, Critical Care and Sleep Medicine, University of Oklahoma, Oklahoma City, OK 73104, USA"},{"name":"Section of Pulmonary, Critical Care and Sleep Medicine, The Oklahoma City VA Healthcare System, Oklahoma City, OK 73104, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8493-9477","authenticated-orcid":false,"given":"Jean I.","family":"Keddissi","sequence":"additional","affiliation":[{"name":"Interventional Pulmonary Program, Section of Pulmonary, Critical Care and Sleep Medicine, University of Oklahoma, Oklahoma City, OK 73104, USA"},{"name":"Section of Pulmonary, Critical Care and Sleep Medicine, The Oklahoma City VA Healthcare System, Oklahoma City, OK 73104, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4892-3640","authenticated-orcid":false,"given":"Houssein A.","family":"Youness","sequence":"additional","affiliation":[{"name":"Interventional Pulmonary Program, Section of Pulmonary, Critical Care and Sleep Medicine, University of Oklahoma, Oklahoma City, OK 73104, USA"},{"name":"Section of Pulmonary, Critical Care and Sleep Medicine, The Oklahoma City VA Healthcare System, Oklahoma City, OK 73104, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,2,13]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1208","DOI":"10.1164\/rccm.201505-0990OC","article-title":"Recent Trends in the Identification of Incidental Pulmonary Nodules","volume":"192","author":"Gould","year":"2015","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1007\/s00408-023-00596-9","article-title":"Solitary Lung Nodule: CT-Guided Transthoracic Biopsy vs Transbronchial Biopsy with Endobronchial Ultrasound and Flexible Bronchoscope, a Meta-Analysis of Randomized Controlled Trials","volume":"201","author":"Ho","year":"2023","journal-title":"Lung"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1159\/000355710","article-title":"Diagnostic Yield and Safety of Electromagnetic Navigation Bronchoscopy for Lung Nodules: A Systematic Review and Meta-Analysis","volume":"87","author":"Gex","year":"2014","journal-title":"Respiration"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1016\/j.jtho.2018.11.013","article-title":"Electromagnetic Navigation Bronchoscopy for Peripheral Pulmonary Lesions: One-Year Results of the Prospective, Multicenter Navigate Study","volume":"14","author":"Folch","year":"2019","journal-title":"J. Thorac. Oncol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1111\/resp.13966","article-title":"Multiplanar 3D Fluoroscopy Redefines Tool\u2013Lesion Relationship during Robotic-Assisted Bronchoscopy","volume":"26","author":"Fuentes","year":"2021","journal-title":"Respirology"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.xjon.2023.07.004","article-title":"Robotic Navigational Bronchoscopy in a Thoracic Surgery Practice: Leveraging Technology in the Management of Pulmonary Nodules Special Issue: Precision Therapy in Lung Cancer","volume":"16","author":"Brownlee","year":"2023","journal-title":"JTCVS Open"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/j.mayocpiqo.2022.02.004","article-title":"Combining Shape-Sensing Robotic Bronchoscopy with Mobile Three-Dimensional Imaging to Verify Tool-in-Lesion and Overcome Divergence: A Pilot Study","volume":"6","author":"Reisenauer","year":"2022","journal-title":"Mayo Clin. Proc. Innov. Qual. Outcomes"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1007\/s00408-021-00421-1","article-title":"Robotic-Assisted Navigation Bronchoscopy as a Paradigm Shift in Peripheral Lung Access","volume":"199","author":"Benn","year":"2021","journal-title":"Lung"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1111\/resp.14626","article-title":"Mobile Cone-Beam Computed Tomography Complementing Shape-Sensing Robotic-Assisted Bronchoscopy in the Small Pulmonary Nodule Sampling: A Multicentre Experience","volume":"29","author":"Folch","year":"2024","journal-title":"Respirology"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Bashour, S.I., Khan, A., Song, J., Chintalapani, G., Kleinszig, G., Sabath, B.F., Lin, J., Grosu, H.B., Jimenez, C.A., and Eapen, G.A. (2024). Improving Shape-Sensing Robotic-Assisted Bronchoscopy Outcomes with Mobile Cone-Beam Computed Tomography Guidance. Diagnostics, 14.","DOI":"10.3390\/diagnostics14171955"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1007\/s00408-022-00578-3","article-title":"Novel Robotic-Assisted Cryobiopsy for Peripheral Pulmonary Lesions","volume":"200","author":"Oberg","year":"2022","journal-title":"Lung"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"107967","DOI":"10.1016\/j.lungcan.2024.107967","article-title":"Cryobiopsy versus Fine-Needle Aspiration for Shape-Sensing Robotic-Assisted Sampling of Small Lung Nodules","volume":"196","author":"Khoor","year":"2024","journal-title":"Lung Cancer"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1361","DOI":"10.1016\/j.athoracsur.2021.12.041","article-title":"Factors Associated with Diagnostic Accuracy of Robotic Bronchoscopy with 12-Month Follow-Up","volume":"115","author":"Agrawal","year":"2023","journal-title":"Ann. Thorac. Surg."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Khan, F., Seaman, J., Hunter, T.D., Ribeiro, D., Laxmanan, B., Kalsekar, I., and Cumbo-Nacheli, G. (2023). Diagnostic Outcomes of Robotic-Assisted Bronchoscopy for Pulmonary Lesions in a Real-World Multicenter Community Setting. BMC Pulm. Med., 23.","DOI":"10.1186\/s12890-023-02465-w"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Hammad Altaq, H., Parmar, M., Syed Hussain, T., Salim, D.J., and Chaudry, F.A. (2023). The Use of Robotic-Assisted Bronchoscopy in the Diagnostic Evaluation of Peripheral Pulmonary Lesions: A Paradigm Shift. Diagnostics, 13.","DOI":"10.3390\/diagnostics13061049"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1016\/j.chest.2021.07.2169","article-title":"Shape-Sensing Robotic-Assisted Bronchoscopy in the Diagnosis of Pulmonary Parenchymal Lesions","volume":"161","author":"Connolly","year":"2022","journal-title":"Chest"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1007\/s00408-022-00590-7","article-title":"Shape-Sensing Robotic-Assisted Bronchoscopy with Concurrent Use of Radial Endobronchial Ultrasound and Cone Beam Computed Tomography in the Evaluation of Pulmonary Lesions","volume":"200","author":"Styrvoky","year":"2022","journal-title":"Lung"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1111\/resp.14368","article-title":"Robotic-Assisted Bronchoscopy versus CT-Guided Transthoracic Biopsy for Diagnosis of Pulmonary Nodules","volume":"28","author":"Reisenauer","year":"2023","journal-title":"Respirology"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1028","DOI":"10.1016\/j.athoracsur.2022.11.022","article-title":"Accuracy of Preliminary Pathology for Robotic Bronchoscopic Biopsy","volume":"116","author":"Vu","year":"2023","journal-title":"Ann. Thorac. Surg."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1016\/j.chest.2020.08.2047","article-title":"Robotic Bronchoscopy for Peripheral Pulmonary Lesions: A Multicenter Pilot and Feasibility Study (BENEFIT)","volume":"159","author":"Chen","year":"2021","journal-title":"Chest"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Chaddha, U., Kovacs, S.P., Manley, C., Hogarth, D.K., Cumbo-Nacheli, G., Bhavani, S.V., Kumar, R., Shende, M., Egan, J.P., and Murgu, S. (2019). Robot-Assisted Bronchoscopy for Pulmonary Lesion Diagnosis: Results from the Initial Multicenter Experience. BMC Pulm. Med., 19.","DOI":"10.1186\/s12890-019-1010-8"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1159\/000498951","article-title":"First Human Use of a New Robotic-Assisted Fiber Optic Sensing Navigation System for Small Peripheral Pulmonary Nodules","volume":"98","author":"Fielding","year":"2019","journal-title":"Respiration"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1001","DOI":"10.1007\/s11701-022-01507-5","article-title":"Novel Approaches Utilizing Robotic Navigational Bronchoscopy: A Single Institution Experience","volume":"17","author":"Iwamoto","year":"2023","journal-title":"J. Robot. Surg."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"977","DOI":"10.1016\/j.chest.2022.10.019","article-title":"Shape-Sensing Robotic-Assisted Bronchoscopy vs Digital Tomosynthesis-Corrected Electromagnetic Navigation Bronchoscopy: A Comparative Cohort Study of Diagnostic Performance","volume":"163","author":"Low","year":"2023","journal-title":"Chest"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"e0981","DOI":"10.1097\/LBR.0000000000000981","article-title":"Shape-Sensing Robotic-Assisted Bronchoscopy (SS-RAB) in Sampling Peripheral Pulmonary Nodules: A Prospective, Multicenter Clinical Feasibility Study in China","volume":"31","author":"Xie","year":"2024","journal-title":"J. Bronchol. Interv. Pulmonol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"634","DOI":"10.1164\/rccm.202401-0192ST","article-title":"American Thoracic Society Documents Assessment of Advanced Diagnostic Bronchoscopy Outcomes for Peripheral Lung Lesions: A Delphi Consensus Definition of Diagnostic Yield and Recommendations for Patient-Centered Study Designs","volume":"209","author":"Gonzalez","year":"2024","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1007\/s11701-024-01898-7","article-title":"Matthew Early Comparison Robotic Bronchoscopy versus Electromagnetic Navigational Bronchoscopy for Biopsy of Pulmonary Nodules in a Thoracic Surgery Practice","volume":"18","author":"Trimble","year":"2024","journal-title":"J. Robot. Surg."},{"key":"ref_28","first-page":"S498","article-title":"Diagnostic Bronchoscopy--Current and Future Perspectives","volume":"5","author":"Leong","year":"2013","journal-title":"J. Thorac. Dis."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.1378\/chest.117.4.1049","article-title":"Diagnostic Yield of Fiberoptic Bronchoscopy in Evaluating Solitary Pulmonary Nodules","volume":"117","author":"Baaklini","year":"2000","journal-title":"Chest"},{"key":"ref_30","first-page":"S304","article-title":"Transthoracic Needle Biopsy of the Lung","volume":"7","author":"Yarmus","year":"2015","journal-title":"J. Thorac. Dis."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1007\/s00330-016-4357-8","article-title":"Complication Rates of CT-Guided Transthoracic Lung Biopsy: Meta-Analysis","volume":"27","author":"Heerink","year":"2017","journal-title":"Eur. Radiol."},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Diddams, M.J., and Lee, H.J. (2023). Robotic Bronchoscopy: Review of Three Systems. Life, 13.","DOI":"10.3390\/life13020354"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1555","DOI":"10.1016\/j.chest.2023.12.024","article-title":"Diagnostic Yield vs Diagnostic Accuracy for Peripheral Lung Biopsy Evaluation: Evidence Supporting a Future Pragmatic End Point","volume":"165","author":"Leonard","year":"2024","journal-title":"Chest"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1164\/rccm.201507-1332OC","article-title":"Diagnostic Yield and Complications of Bronchoscopy for Peripheral Lung Lesions: Results of the AQuIRE Registry","volume":"193","author":"Ost","year":"2016","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1016\/j.lungcan.2005.10.019","article-title":"Percutaneous CT-Guided Fine Needle Aspiration for Lung Cancer Smaller than 2 Cm and Revealed by Ground-Glass Opacity at CT","volume":"51","author":"Shimizu","year":"2006","journal-title":"Lung Cancer"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"234","DOI":"10.2214\/AJR.07.2441","article-title":"Diagnostic Accuracy of CT-Guided Core Biopsy of Ground-Glass Opacity Pulmonary Lesions","volume":"190","author":"Tae","year":"2008","journal-title":"Am. J. Roentgenol."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"106357","DOI":"10.1016\/j.rmed.2021.106357","article-title":"Lesion Characteristics Affecting Yield of Electromagnetic Navigational Bronchoscopy","volume":"180","author":"Bellinger","year":"2021","journal-title":"Respir. Med."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"3279","DOI":"10.21037\/jtd.2020.03.35","article-title":"Robotic Bronchoscopy for Pulmonary Lesions: A Review of Existing Technologies and Clinical Data","volume":"12","author":"Agrawal","year":"2020","journal-title":"J. Thorac. Dis."}],"container-title":["Diagnostics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4418\/15\/4\/450\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T16:32:28Z","timestamp":1760027548000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4418\/15\/4\/450"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,13]]},"references-count":38,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2025,2]]}},"alternative-id":["diagnostics15040450"],"URL":"https:\/\/doi.org\/10.3390\/diagnostics15040450","relation":{},"ISSN":["2075-4418"],"issn-type":[{"value":"2075-4418","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,13]]}}}