{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,29]],"date-time":"2026-06-29T11:37:12Z","timestamp":1782733032012,"version":"3.54.5"},"reference-count":24,"publisher":"MDPI AG","issue":"20","license":[{"start":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T00:00:00Z","timestamp":1761004800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Diagnostics"],"abstract":"<jats:p>Background: Computed tomography (CT) is the standard of reference for diagnosis and follow-up in aortic dissection (AD). Localizing the entry and identifying false and true lumen are as important as differing post-treatment changes from contrast media extravasations. Photon-counting detector CT (PCDCT) allows for virtual monoenergetic (VME) reconstructions, which can augment contrast media effects on lower energy levels, and for virtual non-contrast (VNC) reconstructions. The aim of this study was to analyze the influence of VME reconstructions on contrast media effects in different dissection compartments as well as compare true and VNC series in AD patients. Methods: We retrospectively analyzed PCDCT datasets from 28 patients with aortic dissections, with different dissection types and different treatment statuses. Attenuation and standard deviation values of the ascending and descending aorta, as well as CT values of the false lumen, were measured. These measurements were obtained from VME images at energy levels ranging from 40 to 190 keV in 10 keV increments, as well as from non-contrast (NC) and VNC reconstructions. The signal-to-noise ratio (SNR) was calculated. Additionally, subjective values for dissection assessability and native aspects of the images were acquired for different reconstructions. Results: CT values decreased with higher energy levels in VME imaging. Ascending aorta showed higher attenuation values than descending aorta, which was higher than false lumen (e.g., at 70 keV ascending 357 [310; 419] HU, descending 346 [305; 401] HU and false lumen 298 [248; 363] HU). These differences increased on lower VME reconstructions with statistical significance for the comparisons of ascending and descending aorta with the false lumen on all energy levels. In line with this, SNR showed highest values for ascending aorta compared to descending aorta and false lumen on all energy levels. For NC comparisons, VNC and VME at 190 keV reconstructions showed higher CT values than NC reconstructions (e.g., overall data NC 48 [42; 55] HU, VNC 66 [57; 73] HU, 190 keV 97 [89; 105] HU). Subjective ratings were worse with VNC than with NC images. Conclusions: VME reconstructions on lower energy levels can be helpful in differentiating between true and false lumen in aortic dissections.<\/jats:p>","DOI":"10.3390\/diagnostics15202655","type":"journal-article","created":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T14:24:02Z","timestamp":1761056642000},"page":"2655","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Advancing Aortic Dissection Imaging: First Clinical Experience of Photon-Counting CT with Ultra-Fast Spectral Imaging"],"prefix":"10.3390","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2088-0167","authenticated-orcid":false,"given":"Daniel","family":"Dillinger","sequence":"first","affiliation":[{"name":"Department of Vascular and Endovascular Surgery, Federal Armed Services Hospital Koblenz, 56072 Koblenz, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria","family":"Weiss","sequence":"additional","affiliation":[{"name":"Department of Vascular and Endovascular Surgery, Federal Armed Services Hospital Koblenz, 56072 Koblenz, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6208-3425","authenticated-orcid":false,"given":"Hanns L.","family":"Kaatsch","sequence":"additional","affiliation":[{"name":"Department of Radiology and Neuroradiology, Federal Armed Services Hospital Koblenz, 56072 Koblenz, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Bauer","sequence":"additional","affiliation":[{"name":"Department of Radiology and Neuroradiology, Federal Armed Services Hospital Koblenz, 56072 Koblenz, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Achim","family":"Hagen","sequence":"additional","affiliation":[{"name":"Department of Vascular and Endovascular Surgery, Federal Armed Services Hospital Koblenz, 56072 Koblenz, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8501-2147","authenticated-orcid":false,"given":"Matthias F.","family":"Froelich","sequence":"additional","affiliation":[{"name":"Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, 68167 Manheim, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephan","family":"Waldeck","sequence":"additional","affiliation":[{"name":"Department of Radiology and Neuroradiology, Federal Armed Services Hospital Koblenz, 56072 Koblenz, Germany"},{"name":"Institute of Neuroradiology, University Medical Centre, Johannes Gutenberg University Mainz, 55131 Mainz, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Overhoff","sequence":"additional","affiliation":[{"name":"Department of Radiology and Neuroradiology, Federal Armed Services Hospital Koblenz, 56072 Koblenz, Germany"},{"name":"Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, 68167 Manheim, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,10,21]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"326","DOI":"10.1016\/j.ijcard.2017.05.024","article-title":"Insight into the incidence of acute aortic dissection in the German region of Berlin and Brandenburg","volume":"241","author":"Kurz","year":"2017","journal-title":"Int. J. Cardiol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"e230421186875","DOI":"10.2174\/1573403X16666201014142930","article-title":"Aortic Dissection: A Review of the Pathophysiology, Management and Prospective Advances","volume":"17","author":"Sayed","year":"2021","journal-title":"Curr. Cardiol. Rev."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1093\/icvts\/ivz281","article-title":"Aortic dissection reconsidered: Type, entry site, malperfusion classification adding clarity and enabling outcome prediction","volume":"30","author":"Sievers","year":"2020","journal-title":"Interact. Cardiovasc. Thorac. Surg."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"ezad426","DOI":"10.1093\/ejcts\/ezad426","article-title":"EACTS\/STS Guidelines for diagnosing and treating acute and chronic syndromes of the aortic organ","volume":"65","author":"Czerny","year":"2024","journal-title":"Eur. J. Cardiothorac. Surg."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1136\/heartjnl-2019-314897","article-title":"Imaging for acute aortic syndromes","volume":"106","author":"Carroll","year":"2020","journal-title":"Heart"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1007\/s11886-021-01541-z","article-title":"Computed Tomography Imaging of Aortic Dissections with Endovascular Treatment Considerations","volume":"23","author":"Vargo","year":"2021","journal-title":"Curr. Cardiol. Rep."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"2461","DOI":"10.1007\/s00330-022-09278-1","article-title":"Initial experience on abdominal photon-counting computed tomography in clinical routine: General image quality and dose exposure","volume":"33","author":"Becker","year":"2023","journal-title":"Eur. Radiol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"5578","DOI":"10.1007\/s00330-023-09511-5","article-title":"Photon-Counting Computed Tomography (PC-CT) of the spine: Impact on diagnostic confidence and radiation dose","volume":"33","author":"Rau","year":"2023","journal-title":"Eur. Radiol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1055\/a-2018-3396","article-title":"Photon-Counting Computed Tomography\u2014Basic Principles, Potenzial Benefits, and Initial Clinical Experience","volume":"195","author":"Stein","year":"2023","journal-title":"Rofo"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Dillinger, D., Overhoff, D., Ayx, I., Kaatsch, H.L., Hagen, A., Schonberg, S.O., and Waldeck, S. (2024). Optimizing Arterial Vessel Contrast in Portal Venous Phase with Virtual Monoenergetic Images from Photon-Counting Detector CT Scans of the Abdomen-First Clinical Experiences. Diagnostics, 14.","DOI":"10.3390\/diagnostics14060627"},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Dillinger, D., Overhoff, D., Booz, C., Kaatsch, H.L., Piechotka, J., Hagen, A., Froelich, M.F., Vogl, T.J., and Waldeck, S. (2023). Impact of CT Photon-Counting Virtual Monoenergetic Imaging on Visualization of Abdominal Arterial Vessels. Diagnostics, 13.","DOI":"10.3390\/diagnostics13050938"},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Dillinger, D., Overhoff, D., Froelich, M.F., Kaatsch, H.L., Booz, C., Hagen, A., Vogl, T.J., Schonberg, S.O., and Waldeck, S. (2024). Photon-Counting Detector CT Virtual Monoenergetic Images in Cervical Trauma Imaging-Optimization of Dental Metal Artifacts and Image Quality. Diagnostics, 14.","DOI":"10.3390\/diagnostics14060626"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Kaatsch, H.L., Vollmecke, M.F., Becker, B.V., Dillinger, D., Kubitscheck, L., Wohler, A., Schaaf, S., Piechotka, J., Schreyer, C., and Schwab, R. (2024). Improved Discriminability of Severe Lung Injury and Atelectasis in Thoracic Trauma at Low keV Virtual Monoenergetic Images from Photon-Counting Detector CT. Diagnostics, 14.","DOI":"10.3390\/diagnostics14192231"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"111125","DOI":"10.1016\/j.ejrad.2023.111125","article-title":"Multiphase photon counting detector CT data sets\u2014Which combination of contrast phase and virtual non-contrast algorithm is best suited to replace true non-contrast series in the assessment of active bleeding?","volume":"168","author":"Risch","year":"2023","journal-title":"Eur. J. Radiol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"159","DOI":"10.2307\/2529310","article-title":"The measurement of observer agreement for categorical data","volume":"33","author":"Landis","year":"1977","journal-title":"Biometrics"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1257","DOI":"10.1016\/j.jvir.2017.06.011","article-title":"Noise-Optimized Virtual Monoenergetic Dual-Energy CT Improves Diagnostic Accuracy for the Detection of Active Arterial Bleeding of the Abdomen","volume":"28","author":"Martin","year":"2017","journal-title":"J. Vasc. Interv. Radiol."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1097\/RCT.0b013e31824258cb","article-title":"\u201cSweet spot\u201d for endoleak detection: Optimizing contrast to noise using low keV reconstructions from fast-switch kVp dual-energy CT","volume":"36","author":"Maturen","year":"2012","journal-title":"J. Comput. Assist. Tomogr."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Sun, X., Niwa, T., Nomura, T., Yoshida, R., Koyanagi, K., and Hashimoto, J. (2025). Low-keV Virtual Monoenergetic Imaging for Bronchial Artery Visualization on Photon-Counting Detector Computed Tomography. Diagnostics, 15.","DOI":"10.3390\/diagnostics15111354"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"100666","DOI":"10.1016\/j.ejro.2025.100666","article-title":"High-pitch photon-counting detector computed tomography angiography of the coronary arteries: Qualitative and quantitative evaluation of monoenergetic image reconstructions","volume":"15","author":"Strassl","year":"2025","journal-title":"Eur. J. Radiol. Open"},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Chu, S., Kilinc, O., Pradella, M., Weiss, E., Baraboo, J., Maroun, A., Jarvis, K., Mehta, C.K., Malaisrie, S.C., and Hoel, A.W. (2022). Baseline 4D Flow-Derived in vivo Hemodynamic Parameters Stratify Descending Aortic Dissection Patients with Enlarging Aortas. Front. Cardiovasc. Med., 9.","DOI":"10.3389\/fcvm.2022.905718"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1752","DOI":"10.1002\/jmri.28432","article-title":"Hemodynamic Evaluation of Type B Aortic Dissection Using Compressed Sensing Accelerated 4D Flow MRI","volume":"57","author":"Kilinc","year":"2023","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"816","DOI":"10.1097\/RLI.0000000000000993","article-title":"Photon-Counting Detector CT Angiography for Endoleak Detection After Endovascular Aortic Repair: Triphasic CT with True Noncontrast Versus Biphasic CT with Virtual Noniodine Imaging","volume":"58","author":"Mergen","year":"2023","journal-title":"Investig. Radiol."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1148\/radiol.213260","article-title":"Virtual Noncontrast Abdominal Imaging with Photon-counting Detector CT","volume":"305","author":"Mergen","year":"2022","journal-title":"Radiology"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1148\/radiol.211931","article-title":"Quantum Iterative Reconstruction for Abdominal Photon-counting Detector CT Improves Image Quality","volume":"303","author":"Sartoretti","year":"2022","journal-title":"Radiology"}],"container-title":["Diagnostics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4418\/15\/20\/2655\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T14:38:49Z","timestamp":1761057529000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4418\/15\/20\/2655"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,21]]},"references-count":24,"journal-issue":{"issue":"20","published-online":{"date-parts":[[2025,10]]}},"alternative-id":["diagnostics15202655"],"URL":"https:\/\/doi.org\/10.3390\/diagnostics15202655","relation":{},"ISSN":["2075-4418"],"issn-type":[{"value":"2075-4418","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,21]]}}}