{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T04:38:56Z","timestamp":1787027936995,"version":"build-2736575974"},"reference-count":71,"publisher":"MDPI AG","issue":"24","license":[{"start":{"date-parts":[[2025,12,8]],"date-time":"2025-12-08T00:00:00Z","timestamp":1765152000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Diagnostics"],"abstract":"<jats:p>Purpose: The purpose of this work was to conduct a comprehensive literature review of the challenges encountered in ocular biometry and intraocular lens (IOL) power calculations in patients with keratoconus undergoing cataract surgery and to evaluate the performance of various biometric techniques and IOL power calculation formulas in this population. Methods: A comprehensive literature search was conducted in PubMed for studies published until October 2025. Keywords included \u201ckeratoconus\u201d, \u201cbiometry\u201d, \u201cIOL power calculation\u201d, \u201ccataract surgery\u201d, \u201ckeratometry\u201d, and related terms. Studies evaluating the repeatability of biometric measurement, the accuracy of IOL formulas, and surgical outcomes in keratoconus patients were included. Study quality was assessed using standardized criteria, including study design, measurement standardization, and statistical appropriateness. Results: Twenty studies comprising 1596 eyes with keratoconus were analyzed. Biometric challenges include reduced keratometry repeatability (especially with K &gt; 55 D), altered anterior-to-posterior corneal curvature ratios, anterior chamber depth, unreliable corneal power measurements, and tear film instability affecting measurement consistency. Keratoconus-specific formulas (Barrett\u2019s True-K for keratoconus and Kane\u2019s formula for keratoconus) demonstrated superior accuracy compared to standard formulas. The Barrett True-K formula with predicted posterior corneal astigmatism showed median absolute errors of 0.10\u20130.35 D across all severity stages, with 39\u201372% of eyes within \u00b10.50 D of target refraction. Traditional formulas (excluding SRK\/T) produced hyperopic prediction errors that increased with disease severity. Swept-source optical coherence tomography biometry with total keratometry measurements improved prediction accuracy, particularly in severe keratoconus. Conclusions: IOL power calculation in keratoconus remains challenging due to multiple biometric measurement errors. Keratoconus-specific formulas significantly improve refractive outcomes compared to standard formulas. The use of total keratometry and swept-source OCT biometry, as well as the incorporation of posterior corneal power measurements, enhances accuracy. A multimodal approach combining advanced biometry devices with keratoconus-specific formulas is recommended for optimal outcomes.<\/jats:p>","DOI":"10.3390\/diagnostics15243121","type":"journal-article","created":{"date-parts":[[2025,12,8]],"date-time":"2025-12-08T14:52:24Z","timestamp":1765205544000},"page":"3121","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Challenges in Biometry and Intraocular Lens Power Calculations in Keratoconus: A Review"],"prefix":"10.3390","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0667-3700","authenticated-orcid":false,"given":"Mayank A.","family":"Nanavaty","sequence":"first","affiliation":[{"name":"Sussex Eye Hospital, University Hospitals Sussex NHS Foundation Trust, Brighton BN2 5BF, UK"},{"name":"Brighton & Sussex Medical School, University of Sussex, Falmer, Brighton BN1 9PX, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,12,8]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1016\/j.joco.2019.01.011","article-title":"Intraocular lens power calculation in keratoconus; A review of literature","volume":"31","author":"Ghiasian","year":"2019","journal-title":"J. Curr. Ophthalmol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1016\/j.ajo.2023.03.037","article-title":"Intraocular Lens Power Calculations in Keratoconus Eyes Comparing Keratometry, Total Keratometry, and Newer Formulae","volume":"253","author":"Heath","year":"2023","journal-title":"Am. J. Ophthalmol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1016\/j.survophthal.2023.09.005","article-title":"Refractive surgical correction and treatment of keratoconus","volume":"69","author":"Bagaglia","year":"2024","journal-title":"Surv. Ophthalmol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1097\/ICO.0000000000002150","article-title":"The Prevalence and Risk Factors for Keratoconus: A Systematic Review and Meta-Analysis","volume":"39","author":"Hashemi","year":"2020","journal-title":"Cornea"},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Helaly, H.A., Ibrahim, T.M., Hassan, M.S., and El-Mansy, M.S. (2025). Studying the effect of keratoconus severity on the accuracy of intraocular lens power calculation using newer keratoconus-specific formulas. BMC Ophthalmol., 25.","DOI":"10.1186\/s12886-025-04040-9"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"349","DOI":"10.4103\/sjopt.sjopt_15_24","article-title":"Intraocular lens power calculation in challenging cases","volume":"39","author":"Ma","year":"2024","journal-title":"Saudi J. Ophthalmol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1437","DOI":"10.1038\/s41433-025-03742-0","article-title":"Understanding the relationship between astigmatism, posterior cornea and corneal thickness: A move to total corneal power","volume":"39","author":"Nanavaty","year":"2025","journal-title":"Eye"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1037","DOI":"10.1016\/j.ophtha.2020.02.008","article-title":"Accuracy of Intraocular Lens Power Formulas Modified for Patients with Keratoconus","volume":"127","author":"Kane","year":"2020","journal-title":"Ophthalmology"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1136\/bjophthalmol-2013-303829","article-title":"Cataract surgery outcome in eyes with keratoconus","volume":"98","author":"Watson","year":"2014","journal-title":"Br. J. Ophthalmol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"742","DOI":"10.1016\/j.jcrs.2006.01.063","article-title":"Refractive lens exchange in keratoconus","volume":"32","author":"Leccisotti","year":"2006","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1080\/08820538.2022.2112702","article-title":"Cataract surgery in Keratoconus revisited\u2014An update on preoperative and intraoperative considerations and postoperative outcomes","volume":"38","author":"Singh","year":"2023","journal-title":"Semin. Ophthalmol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1007\/s10792-025-03430-8","article-title":"Intraocular lens power calculation in cataract patients with keratoconus: Bayesian network meta-analysis","volume":"45","author":"Tian","year":"2025","journal-title":"Int. Ophthalmol."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"434","DOI":"10.1007\/s10792-024-03332-1","article-title":"Total keratometry versus standard keratometry for intraocular lens power calculation in eyes with keratoconus","volume":"44","year":"2024","journal-title":"Int. Ophthalmol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1839","DOI":"10.1007\/s00417-024-06371-7","article-title":"Accuracy of intraocular lens power formulas in eyes with keratoconus: Multi-center study in Japan","volume":"262","author":"Yokogawa","year":"2024","journal-title":"Graefes Arch. Clin. Exp. Ophthalmol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1097\/j.jcrs.0000000000001088","article-title":"Accuracy of intraocular lens calculations in eyes with keratoconus","volume":"49","author":"Vandevenne","year":"2022","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_16","first-page":"967","article-title":"Impact of ultrasound and optical biometry on refractive outcomes of cataract surgery after penetrating keratoplasty in keratoconus","volume":"12","author":"Krysik","year":"2019","journal-title":"Int. J. Ophthalmol."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"576","DOI":"10.1016\/j.jcrs.2018.11.029","article-title":"Intraocular lens power calculation in eyes with keratoconus","volume":"45","author":"Savini","year":"2019","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1389","DOI":"10.1097\/j.jcrs.0000000000000638","article-title":"Toric intraocular lens power calculation in cataract patients with keratoconus","volume":"47","author":"Ton","year":"2021","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1065","DOI":"10.1016\/j.jcrs.2014.08.043","article-title":"Effect of keratoconus grades on repeatability of keratometry readings: Comparison of 5 devices","volume":"41","author":"Hashemi","year":"2015","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Kamiya, K., Kono, Y., Takahashi, M., and Shoji, N. (2018). Comparison of Simulated Keratometry and Total Refractive Power for Keratoconus According to the Stage of Amsler-Krumeich Classification. Sci. Rep., 8.","DOI":"10.1038\/s41598-018-31008-1"},{"key":"ref_21","first-page":"412","article-title":"Association between keratoconus disease severity and repeatability in measurements of parameters for detection of progression","volume":"98","author":"Gustafsson","year":"2020","journal-title":"Acta Ophthalmologica"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/j.joco.2019.01.010","article-title":"Comparison of Anterior Chamber Depth between Normal and Keratoconic Eyes: A Systematic Review and Meta-analysis","volume":"32","author":"Hashemi","year":"2020","journal-title":"J. Curr. Ophthalmol."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"508","DOI":"10.4103\/IJO.IJO_1241_23","article-title":"Current concepts in the management of cataract with keratoconus","volume":"72","author":"Nicholson","year":"2024","journal-title":"Indian J. Ophthalmol."},{"key":"ref_24","first-page":"25158414251348882","article-title":"Advances in IOL calculations in patients with keratoconus","volume":"17","author":"Gershoni","year":"2025","journal-title":"Ther. Adv. Ophthalmol."},{"key":"ref_25","first-page":"25158414211063283","article-title":"Agreement in anterior segment measurements between swept-source and Scheimpflug-based optical biometries in keratoconic eyes: A pilot study","volume":"14","author":"Chalkiadaki","year":"2022","journal-title":"Ther. Adv. Ophthalmol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"884","DOI":"10.3928\/1081597X-20121106-02","article-title":"Outcomes of pseudophakic toric intraocular lens implantation in Keratoconic eyes with cataract","volume":"28","author":"Nanavaty","year":"2012","journal-title":"J. Refract. Surg."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"2187","DOI":"10.1016\/j.ophtha.2006.06.036","article-title":"Potential complications of ocular surgery in patients with coexistent keratoconus and Fuchs\u2019 endothelial dystrophy","volume":"113","author":"Jurkunas","year":"2006","journal-title":"Ophthalmology."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1016\/S0886-3350(13)80338-0","article-title":"The Hoffer Q formula: A comparison of theoretic and regression formulas","volume":"19","author":"Hoffer","year":"1993","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1097\/00003226-199205000-00011","article-title":"Axial length in keratoconus","volume":"11","author":"Lanier","year":"1992","journal-title":"Cornea"},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Bamdad, S., Fathian, A., Khalili, M.R., Mohammadi, M., and Attar, A. (2025). Biometry and keratometry measurements after intracorneal ring segment implantation in keratoconus patients: A pilot comparison between Pentacam AXL and IOL Master 700. BMC Ophthalmol., 25.","DOI":"10.1186\/s12886-025-03914-2"},{"key":"ref_31","first-page":"7589816","article-title":"Surgical Options for the Refractive Correction of Keratoconus: Myth or Reality","volume":"2017","author":"Romano","year":"2017","journal-title":"J. Ophthalmol."},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Yahalomi, T., Achiron, A., Hecht, I., Arnon, R., Levinger, E., Pikkel, J., and Tuuminen, R. (2022). Refractive Outcomes of Non-Toric and Toric Intraocular Lenses in Mild, Moderate and Advanced Keratoconus: A Systematic Review and Meta-Analysis. J. Clin. Med., 11.","DOI":"10.3390\/jcm11092456"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1201","DOI":"10.1136\/bjophthalmol-2015-307779","article-title":"Evaluation and comparison of the new swept source OCT-based IOLMaster 700 with the IOLMaster 500","volume":"100","author":"Akman","year":"2016","journal-title":"Br. J. Ophthalmol."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"577","DOI":"10.2147\/OPTH.S487889","article-title":"A Retrospective Trial Comparing Prediction Accuracy of Three Biometers in Short, Medium, and Long Eyes","volume":"19","author":"Multack","year":"2025","journal-title":"Clin. Ophthalmol."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1167\/tvst.13.10.40","article-title":"A New Intraocular Lens Power Formula Integrating an Artificial Intelligence-Powered Estimation for Effective Lens Position Based on Chinese Eyes","volume":"13","author":"Lou","year":"2024","journal-title":"Transl. Vis. Sci. Technol."},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Stopyra, W., Voytsekhivskyy, O., and Grzybowski, A. (2025). Prediction of Seven Artificial Intelligence-Based Intraocular Lens Power Calculation Formulas in Medium-Long Caucasian Eyes. Life, 15.","DOI":"10.3390\/life15010045"},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Bagheri, N.M., Kadkhodaei, M., Pirhadi, S., and Mosaddegh, P. (2021). Effects of intracorneal ring segments implementation technique and design on corneal biomechanics and keratometry in a personalized computational analysis. Sci. Rep., 11.","DOI":"10.1038\/s41598-021-93821-5"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1167\/tvst.11.3.19","article-title":"Optical Evaluation of Intracorneal Ring Segment Surgery in Keratoconus","volume":"11","author":"Alejandre","year":"2022","journal-title":"Transl. Vis. Sci. Technol."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"1411","DOI":"10.1097\/j.jcrs.0000000000000642","article-title":"New treatment algorithm for keratoconus and cataract: Small-aperture IOL insertion with sequential topography-guided photorefractive keratectomy and simultaneous accelerated corneal crosslinking","volume":"47","author":"Northey","year":"2021","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"2609","DOI":"10.1007\/s10792-021-01820-2","article-title":"Outcomes and complications of implantable collamer lens for mild to advance keratoconus","volume":"41","author":"Fairaq","year":"2021","journal-title":"Int. Ophthalmol."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"1539","DOI":"10.2147\/OPTH.S44741","article-title":"Revisiting keratoconus diagnosis and progression classification based on evaluation of corneal asymmetry indices, derived from Scheimpflug imaging in keratoconic and suspect cases","volume":"7","author":"Kanellopoulos","year":"2013","journal-title":"Clin. Ophthalmol."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/j.clae.2015.01.008","article-title":"Characteristics and associations of keratoconus patients","volume":"38","author":"Naderan","year":"2015","journal-title":"Cont. Lens Anterior Eye"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"e486","DOI":"10.1111\/aos.13298","article-title":"Comparison of corneal measurements in keratoconus using swept-source optical coherence tomography and combined Placido-Scheimpflug imaging","volume":"95","author":"Chan","year":"2017","journal-title":"Acta Ophthalmol."},{"key":"ref_44","first-page":"481238","article-title":"Comparison of Optical versus Ultrasonic Biometry in Keratoconic Eyes","volume":"2013","author":"Cingu","year":"2013","journal-title":"J. Ophthalmol."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1016\/j.jcrs.2014.04.039","article-title":"Repeatability and reproducibility of a new optical biometer in normal and keratoconic eyes","volume":"41","author":"Yagci","year":"2015","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"2213","DOI":"10.1038\/s41433-020-01238-7","article-title":"Repeatability and reliability of measurements obtained by the combined Scheimpflug and Placido-disk tomography in different stages of keratoconus","volume":"35","author":"Akbas","year":"2021","journal-title":"Eye"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1016\/j.ajo.2020.06.013","article-title":"Repeatability of the Pentacam HR in Various Grades of Keratoconus","volume":"219","author":"Kreps","year":"2020","journal-title":"Am. J. Ophthalmol."},{"key":"ref_48","first-page":"25158414241232258","article-title":"Keratoconus: Exploring fundamentals and future perspectives\u2014A comprehensive systematic review","volume":"16","author":"Niazi","year":"2024","journal-title":"Ther. Adv. Ophthalmol."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"201","DOI":"10.4103\/sjopt.sjopt_184_21","article-title":"Cataract in keratoconus: Six-month results and a comparison of standard intraocular lens power calculation formulas","volume":"36","author":"Said","year":"2022","journal-title":"Saudi J. Ophthalmol."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1097\/ICU.0000000000000908","article-title":"Cataract surgery considerations in patients with prior history of keratoconus and ectasia","volume":"34","author":"Moshirfar","year":"2023","journal-title":"Curr. Opin. Ophthalmol."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"1532","DOI":"10.1177\/1120672120960585","article-title":"Long-term refractive outcomes in patients with cataracts and keratoconus after phacoemulsification with toric intraocular lens implant","volume":"31","year":"2021","journal-title":"Eur. J. Ophthalmol."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"2190","DOI":"10.1016\/j.jcrs.2015.11.001","article-title":"Intraocular lens power calculation in cases with posterior keratoconus","volume":"41","author":"Tamaoki","year":"2015","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"1052","DOI":"10.1016\/j.jfo.2020.11.031","article-title":"The role of posterior corneal power in 21st century biometry: A review","volume":"44","author":"Lu","year":"2021","journal-title":"J. Fr. Ophtalmol."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"e253","DOI":"10.3928\/1081597X-20240311-06","article-title":"Differences Between Simulated Keratometry and Total Corneal Power in Eyes with Keratoconus and a Formula to Improve IOL Power Calculation Results","volume":"40","author":"Coutinho","year":"2024","journal-title":"J. Refract. Surg."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1080\/08164622.2023.2215382","article-title":"Prediction of total corneal power in keratoconus using anterior surface data","volume":"107","author":"Camellin","year":"2024","journal-title":"Clin. Exp. Optom."},{"key":"ref_56","first-page":"44","article-title":"A comprehensive review on corneal crosslinking","volume":"14","author":"Naranjo","year":"2024","journal-title":"Taiwan J. Ophthalmol."},{"key":"ref_57","doi-asserted-by":"crossref","unstructured":"Papachristoforou, N., Ueno, A., Ledwos, K., Bartus, J., Nowinska, A., and Karska-Basta, I. (2025). A Review of Keratoconus Cross-Linking Treatment Methods. J. Clin. Med., 14.","DOI":"10.3390\/jcm14051702"},{"key":"ref_58","doi-asserted-by":"crossref","unstructured":"Wang, Z., Ma, H., Zhang, Y., Yuan, Y., Liu, Y., and Chen, Y. (2024). Differences in anterior chamber depth in keratoconus patients with binocular very asymmetry ectasia. BMC Ophthalmol., 24.","DOI":"10.1186\/s12886-024-03353-5"},{"key":"ref_59","doi-asserted-by":"crossref","unstructured":"Ortiz-Toquero, S., Fuente, C., Auladell, C., and Arnalich-Montiel, F. (2023). Influence of Keratoconus Severity on Detecting True Progression with Scheimpflug Imaging and Anterior Segment Optical Coherence Tomography. Life, 13.","DOI":"10.3390\/life13071474"},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"310","DOI":"10.3928\/1081597X-20220404-02","article-title":"Flattening of Central, Paracentral, and Peripheral Cones After Non-accelerated and Accelerated Epithelium-off CXL in Keratoconus: A Multicenter Study","volume":"38","author":"Ashena","year":"2022","journal-title":"J. Refract. Surg."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1111\/cxo.12927","article-title":"Impact of classifying keratoconus location based on keratometry or pachymetry on progression parameters","volume":"103","author":"Bardan","year":"2020","journal-title":"Clin. Exp. Optom."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"690","DOI":"10.3928\/1081597X-20180824-01","article-title":"Outcomes of Simultaneous and Sequential Cross-linking with Excimer Laser Surface Ablation in Keratoconus","volume":"34","author":"Bardan","year":"2018","journal-title":"J. Refract. Surg."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1080\/02713683.2023.2270727","article-title":"Development of a Web-Based Algorithm for Understanding the Intraocular Lens-Based Surgery in Stable and Progressing Keratoconus for Non-Specialist Ophthalmologists","volume":"49","author":"Nanavaty","year":"2024","journal-title":"Curr. Eye Res."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"6647993","DOI":"10.1155\/joph\/6647993","article-title":"The Combined Utilization of Epithelial Thickness and Tomographic Parameters in Keratoconus Detection","volume":"2025","author":"Salman","year":"2025","journal-title":"J. Ophthalmol."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1038\/eye.2014.230","article-title":"Safety and efficacy of epithelium removal and transepithelial corneal collagen crosslinking for keratoconus","volume":"29","author":"Shalchi","year":"2015","journal-title":"Eye"},{"key":"ref_66","doi-asserted-by":"crossref","unstructured":"Gustafsson, I., Bizios, D., Ivarsen, A., and Hjortdal, J.O. (2023). Patient experience and repeatability of measurements made with the Pentacam HR in patients with keratoconus. BMC Ophthalmol., 23.","DOI":"10.1186\/s12886-023-02930-4"},{"key":"ref_67","doi-asserted-by":"crossref","unstructured":"Aramberri, J., Hoffer, K.J., Olsen, T., Savini, G., and Shammas, H.J. (2024). Emmetropia Verifying Optical (EVO) Formula. Intraocular Lens Calculations, Springer International Publishing.","DOI":"10.1007\/978-3-031-50666-6"},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"778","DOI":"10.1097\/j.jcrs.0000000000000082","article-title":"Intraocular lens power calculation in eyes with keratoconus","volume":"46","author":"Garzon","year":"2020","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/j.ajo.2019.11.019","article-title":"Accuracy of Intraocular Lens Formulas in Eyes with Keratoconus","volume":"212","author":"Wang","year":"2020","journal-title":"Am. J. Ophthalmol."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"3739","DOI":"10.2147\/OPTH.S492253","article-title":"Fluctuations of Anterior Chamber Depth and Astigmatism in Pseudophakic Eyes","volume":"18","author":"Tutchenko","year":"2024","journal-title":"Clin. Ophthalmol."},{"key":"ref_71","doi-asserted-by":"crossref","unstructured":"Ramsauer, M., Luft, N., Vounotrypidis, E., Priglinger, S.G., and Mayer, W.J. (2024). Accuracy of toric intraocular lens power calculation depending on different keratometry values using a novel network based software platform. Front. Med., 11.","DOI":"10.3389\/fmed.2024.1363286"}],"container-title":["Diagnostics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4418\/15\/24\/3121\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,8]],"date-time":"2025-12-08T15:02:54Z","timestamp":1765206174000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4418\/15\/24\/3121"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,8]]},"references-count":71,"journal-issue":{"issue":"24","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["diagnostics15243121"],"URL":"https:\/\/doi.org\/10.3390\/diagnostics15243121","relation":{},"ISSN":["2075-4418"],"issn-type":[{"value":"2075-4418","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,8]]}}}