{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,3]],"date-time":"2026-02-03T01:14:32Z","timestamp":1770081272301,"version":"3.49.0"},"reference-count":45,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2026,2,1]],"date-time":"2026-02-01T00:00:00Z","timestamp":1769904000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Diagnostics"],"abstract":"<jats:p>Background: Age-related macular degeneration (AMD) is a major cause of vision loss, yet publicly available Optical Coherence Tomography (OCT) datasets lack demographic diversity, particularly from South Asian populations. Existing datasets largely represent Western cohorts, limiting AI generalizability. Moreover, raw OCT volumes contain redundant spatial information and speckle noise, hindering efficient analysis. Methods: We introduce BanglaOCT2025, a retrospective dataset collected from the National Institute of Ophthalmology and Hospital (NIOH), Bangladesh, using Nidek RS-330 Duo 2 and RS-3000 Advance systems. We propose a novel preprocessing pipeline comprising two stages: (1) A constraint-based centroid minimization algorithm automatically localizes the foveal center and extracts a fixed 33-slice macular sub-volume, robust to retinal tilt and acquisition variability; and (2) A self-supervised volumetric denoising module based on a Flip-Flop Swin Transformer (FFSwin) backbone suppresses speckle noise without requiring paired clean reference data. Results: The dataset comprises 1585 OCT volumes (202,880 B-scans), including 857 expert-annotated cases (54 DryAMD, 61 WetAMD, and 742 NonAMD). Denoising quality was evaluated using reference-free volumetric metrics, paired statistical analysis, and blinded clinical review by a retinal specialist, confirming preservation of pathological biomarkers and absence of hallucination. Under a controlled paired evaluation using the same classifier with frozen weights, downstream AMD classification accuracy improved from 69.08% to 99.88%, interpreted as an upper-bound estimate of diagnostic signal recoverability rather than independent generalization. Conclusions: BanglaOCT2025 is the first clinically validated OCT dataset representing the Bengali population and establishes a reproducible fovea-centric volumetric preprocessing and restoration framework for AMD analysis, with future validation across independent and multi-centre test cohorts.<\/jats:p>","DOI":"10.3390\/diagnostics16030420","type":"journal-article","created":{"date-parts":[[2026,2,2]],"date-time":"2026-02-02T12:49:44Z","timestamp":1770036584000},"page":"420","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["BanglaOCT2025: A Population-Specific Fovea-Centric OCT Dataset with Self-Supervised Volumetric Restoration Using Flip-Flop Swin Transformers"],"prefix":"10.3390","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5837-2099","authenticated-orcid":false,"given":"Chinmay","family":"Bepery","sequence":"first","affiliation":[{"name":"Department of Computer Science and Information Technology, Patuakhali Science and Technology University, Patuakhali 8602, Bangladesh"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G. M. Atiqur","family":"Rahaman","sequence":"additional","affiliation":[{"name":"Computer Science and Engineering Discipline, Khulna University, Khulna 9208, Bangladesh"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rameswar","family":"Debnath","sequence":"additional","affiliation":[{"name":"Computer Science and Engineering Discipline, Khulna University, Khulna 9208, Bangladesh"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sajib","family":"Saha","sequence":"additional","affiliation":[{"name":"The Australian e-Health Research Centre, CSIRO, Perth, WA 6151,    Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Md. Shafiqul","family":"Islam","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Sher-e-Bangla Medical College Hospital, Barishal 8200, Bangladesh"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-6624-8643","authenticated-orcid":false,"given":"Md. Emranul Islam","family":"Abir","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Khulna Medical College Hospital, Khulna 9100, Bangladesh"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-9304-3826","authenticated-orcid":false,"given":"Sanjay Kumar","family":"Sarker","sequence":"additional","affiliation":[{"name":"Department of Vitreo-Retina, National Institute of Ophthalmology and Hospital, Dhaka 1207, Bangladesh"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2026,2,1]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1178","DOI":"10.1126\/science.1957169","article-title":"Optical Coherence Tomography","volume":"254","author":"Huang","year":"1991","journal-title":"Science"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Drexler, W., and Fujimoto, J.G. (2008). Optical Coherence Tomography: Technology and Applications, Springer Science & Business Media.","DOI":"10.1007\/978-3-540-77550-8"},{"key":"ref_3","first-page":"1","article-title":"A Paradigm Shift in Imaging Biomarkers in Neovascular Age-Related Macular Degeneration","volume":"50","author":"Waldstein","year":"2016","journal-title":"Prog. Retin. Eye Res."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1016\/j.ophtha.2013.07.013","article-title":"Quantitative Classification of Eyes with and without Intermediate Age-Related Macular Degeneration Using Optical Coherence Tomography","volume":"121","author":"Farsiu","year":"2014","journal-title":"Ophthalmology"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"103092","DOI":"10.1016\/j.media.2024.103092","article-title":"OCTA-500: A Retinal Dataset for Optical Coherence Tomography Angiography Study","volume":"93","author":"Li","year":"2024","journal-title":"Med. Image Anal."},{"key":"ref_6","first-page":"375","article-title":"Annotated Retinal Optical Coherence Tomography Images (AROI) Database for Joint Retinal Layer and Fluid Segmentation","volume":"62","author":"Vatavuk","year":"2021","journal-title":"Autom. \u010casopis Autom. Mjer. Elektron. Ra\u010dunarstvo Komun."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"625","DOI":"10.1167\/iovs.10-5886","article-title":"Race- and Sex-Related Differences in Retinal Thickness and Foveal Pit Morphology","volume":"52","author":"Dubis","year":"2011","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1038\/s41591-018-0316-z","article-title":"A Guide to Deep Learning in Healthcare","volume":"25","author":"Esteva","year":"2019","journal-title":"Nat. Med."},{"key":"ref_9","unstructured":"NIDEK Co., Ltd. (2025, November 07). Available online: https:\/\/www.nidek-intl.com\/."},{"key":"ref_10","unstructured":"(2025, December 16). Logiciel NAVIS-EX\u2014NIDEK France. Available online: https:\/\/www.nidek.fr\/en\/logiciel-navis-ex\/logiciel-navis-ex-2\/."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"2012","DOI":"10.1167\/iovs.04-0335","article-title":"Macular Segmentation with Optical Coherence Tomography","volume":"46","author":"Ishikawa","year":"2005","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"e39","DOI":"10.1016\/j.ophtha.2008.05.017","article-title":"Time Course of Morphologic Effects on Different Retinal Compartments after Ranibizumab Therapy in Age-Related Macular Degeneration","volume":"115","author":"Ahlers","year":"2008","journal-title":"Ophthalmology"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1453","DOI":"10.1136\/bjo.2008.153643","article-title":"Comparison of Retinal Thickness Measurements and Segmentation Performance of Four Different Spectral and Time Domain OCT Devices in Neovascular Age-Related Macular Degeneration","volume":"93","author":"Mylonas","year":"2009","journal-title":"Br. J. Ophthalmol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"748","DOI":"10.1016\/j.media.2011.06.005","article-title":"Automated Macular Pathology Diagnosis in Retinal OCT Images Using Multi-Scale Spatial Pyramid and Local Binary Patterns in Texture and Shape Encoding","volume":"15","author":"Liu","year":"2011","journal-title":"Med. Image Anal."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1145","DOI":"10.1364\/JOSA.66.001145","article-title":"Some Fundamental Properties of Speckle","volume":"66","author":"Goodman","year":"1976","journal-title":"J. Opt. Soc. Am."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"046003","DOI":"10.1117\/1.JBO.26.4.046003","article-title":"Deep Feature Loss to Denoise OCT Images Using Deep Neural Networks","volume":"26","author":"Mehdizadeh","year":"2021","journal-title":"J. Biomed. Opt."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Li, F., Wu, Q., Jia, B., and Yang, Z. (2025). Speckle Noise Removal in OCT Images via Wavelet Transform and DnCNN. Appl. Sci., 15.","DOI":"10.3390\/app15126557"},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Bepery, C., Rahaman, G.M.A., Debnath, R., and Saha, S. (2025, January 13\u201315). Forward Autoencoder Approach for Denoising Retinal OCT Images. Proceedings of the 2025 International Conference on Electrical, Computer and Communication Engineering, ECCE, Chittagong, Bangladesh.","DOI":"10.1109\/ECCE64574.2025.11013051"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"34008","DOI":"10.1117\/1.JMI.11.3.034008","article-title":"Transformer Enhanced Autoencoder Rendering Cleaning of Noisy Optical Coherence Tomography Images","volume":"11","author":"Ahmed","year":"2024","journal-title":"J. Med. Imaging"},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"\u00d6zkan, A., Stoykova, E., Sikora, T., and Madjarova, V. (2024). Denoising OCT Images Using Steered Mixture of Experts with Multi-Model Inference. arXiv.","DOI":"10.1117\/12.3000625"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1090","DOI":"10.1038\/s41592-018-0216-7","article-title":"Content-Aware Image Restoration: Pushing the Limits of Fluorescence Microscopy","volume":"15","author":"Weigert","year":"2018","journal-title":"Nat. Methods"},{"key":"ref_22","unstructured":"(2025, November 07). Download NAVIS-EX by NIDEK Co., Ltd.. Available online: https:\/\/navis-ex.software.informer.com\/download\/."},{"key":"ref_23","unstructured":"(2025, December 16). RS-330\u2014NIDEK France. Available online: https:\/\/www.nidek.fr\/en\/oct-angiographie\/rs-330\/."},{"key":"ref_24","unstructured":"(2025, December 16). RS-3000 Advance 2\u2014NIDEK France. Available online: https:\/\/www.nidek.fr\/en\/oct-angiographie\/rs-3000-advance-2\/."},{"key":"ref_25","unstructured":"(2025, December 16). RS-330 Manual|ManualsLib. Available online: https:\/\/www.manualslib.com\/manual\/3952363\/Nidek-Medical-Rs-330.html#manual."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1001\/archopht.1995.01100030081025","article-title":"Optical Coherence Tomography of the Human Retina","volume":"113","author":"Hee","year":"1995","journal-title":"Arch. Ophthalmol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"2211","DOI":"10.1001\/jama.2017.18152","article-title":"Development and Validation of a Deep Learning System for Diabetic Retinopathy and Related Eye Diseases Using Retinal Images from Multiethnic Populations with Diabetes","volume":"318","author":"Ting","year":"2017","journal-title":"JAMA"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"159","DOI":"10.2307\/2529310","article-title":"The Measurement of Observer Agreement for Categorical Data","volume":"33","author":"Landis","year":"1977","journal-title":"Biometrics"},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Diabetic Retinopathy Clinical Research Network, Browning, D.J., Glassman, A.R., Aiello, L.P., Beck, R.W., Brown, D.M., Fong, D.S., Bressler, N.M., Danis, R.P., and Kinyoun, J.L. (2007). Relationship between Optical Coherence Tomography\u2013Measured Central Retinal Thickness and Visual Acuity in Diabetic Macular Edema. Ophthalmology, 114, 525\u2013536.","DOI":"10.1016\/j.ophtha.2006.06.052"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"19413","DOI":"10.1364\/OE.18.019413","article-title":"Automatic Segmentation of Seven Retinal Layers in SDOCT Images Congruent with Expert Manual Segmentation","volume":"18","author":"Chiu","year":"2010","journal-title":"Opt. Express"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"1436","DOI":"10.1109\/TMI.2009.2016958","article-title":"Automated 3-D Intraretinal Layer Segmentation of Macular Spectral-Domain Optical Coherence Tomography Images","volume":"28","author":"Garvin","year":"2009","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Goodman, J.W. (1975). Statistical Properties of Laser Speckle Patterns. Laser Speckle and Related Phenomena, Springer.","DOI":"10.1007\/978-3-662-43205-1_2"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1117\/1.429925","article-title":"Speckle in Optical Coherence Tomography","volume":"4","author":"Schmitt","year":"1999","journal-title":"J. Biomed. Opt."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"2034","DOI":"10.1109\/TMI.2013.2271904","article-title":"Fast Acquisition and Reconstruction of Optical Coherence Tomography Images via Sparse Representation","volume":"32","author":"Fang","year":"2013","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Liu, Z., Lin, Y., Cao, Y., Hu, H., Wei, Y., Zhang, Z., Lin, S., and Guo, B. (2021, January 10\u201317). Swin Transformer: Hierarchical Vision Transformer Using Shifted Windows. Proceedings of the IEEE\/CVF International Conference on Computer Vision, Montreal, QC, Canada.","DOI":"10.1109\/ICCV48922.2021.00986"},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Hatamizadeh, A., Tang, Y., Nath, V., Yang, D., Myronenko, A., Landman, B., Roth, H.R., and Xu, D. (2022, January 3\u20138). Unetr: Transformers for 3d Medical Image Segmentation. Proceedings of the IEEE\/CVF Winter Conference on Applications of Computer Vision, Waikoloa, HI, USA.","DOI":"10.1109\/WACV51458.2022.00181"},{"key":"ref_37","unstructured":"Lehtinen, J., Munkberg, J., Hasselgren, J., Laine, S., Karras, T., Aittala, M., and Aila, T. (2018, January 10\u201315). Noise2Noise: Learning Image Restoration without Clean Data. Proceedings of the 35th International Conference on Machine Learning, Stockholm, Sweden."},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Krull, A., Buchholz, T.-O., and Jug, F. (2019, January 15\u201320). Noise2Void\u2014Learning Denoising From Single Noisy Images. Proceedings of the 2019 IEEE\/CVF Conference on Computer Vision and Pattern Recognition (CVPR), Long Beach, CA, USA.","DOI":"10.1109\/CVPR.2019.00223"},{"key":"ref_39","unstructured":"Batson, J., and Royer, L. (2019). Noise2Self: Blind Denoising by Self-Supervision. arXiv."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1109\/TCI.2016.2644865","article-title":"Loss Functions for Image Restoration With Neural Networks","volume":"3","author":"Zhao","year":"2017","journal-title":"IEEE Trans. Comput. Imaging"},{"key":"ref_41","unstructured":"Goodfellow, I., Bengio, Y., Courville, A., and Bengio, Y. (2016). Deep Learning, MIT Press."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1109\/34.56205","article-title":"Scale-Space and Edge Detection Using Anisotropic Diffusion","volume":"12","author":"Perona","year":"1990","journal-title":"IEEE Trans. Pattern Anal. Mach. Intell."},{"key":"ref_43","unstructured":"Sobel, I., and Feldman, G. (1968). A 3\u00d73 Isotropic Gradient Operator for Image Processing, Stanford Artificial Intelligence Project (SAIL)."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1002\/j.1538-7305.1948.tb01338.x","article-title":"A Mathematical Theory of Communication","volume":"27","author":"Shannon","year":"1948","journal-title":"Bell Syst. Tech. J."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1109\/MSP.2008.930649","article-title":"Mean Squared Error: Love It or Leave It? A New Look at Signal Fidelity Measures","volume":"26","author":"Wang","year":"2009","journal-title":"IEEE Signal Process. Mag."}],"container-title":["Diagnostics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4418\/16\/3\/420\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,2]],"date-time":"2026-02-02T13:00:35Z","timestamp":1770037235000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4418\/16\/3\/420"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,1]]},"references-count":45,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2026,2]]}},"alternative-id":["diagnostics16030420"],"URL":"https:\/\/doi.org\/10.3390\/diagnostics16030420","relation":{},"ISSN":["2075-4418"],"issn-type":[{"value":"2075-4418","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,1]]}}}