{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T18:46:49Z","timestamp":1790880409926,"version":"4.1.0"},"reference-count":28,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T00:00:00Z","timestamp":1770681600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Diagnostics"],"abstract":"<jats:p>Objectives: This study aims to evaluate the intrasession repeatability of the HBM-1 (Huvitz) optical biometer and to assess its agreement with the IOLMaster 700 (Zeiss) for the main biometric parameters used in intraocular lens (IOL) power calculation and in myopia management. Methods: A cross-sectional observational study was conducted in 82 eyes of 82 patients with the following age distribution: pediatric 26.8%, young adults 35.4%, and older adults 37.8% (total range 6\u201379 years). Optical biometry was performed three consecutive times with both biometers in the same session by a single trained examiner. HBM-1 repeatability was assessed using the within-subject standard deviation (Sw), the repeatability coefficient, and the intraclass correlation coefficient (ICC). Agreement between biometers was analyzed using Bland\u2013Altman plots (limits of agreement, LoA). Results: The HBM-1 showed excellent intrasession repeatability, with very low Sw values\u2014on the order of hundredths of a millimeter for axial length (AL), anterior chamber depth (ACD), and lens thickness (LT), and hundredths of a diopter for keratometry\u2014with ICC \u2265 0.97 for most parameters. The mean bias (HBM-1 vs. IOLMaster 700) was small: AL 0.012 \u00b1 0.052 mm (p = 0.045; LoA: \u22120.09 to 0.11 mm), ACD 0.059 \u00b1 0.068 mm (p &lt; 0.001; \u22120.07 to 0.19 mm), LT 0.052 \u00b1 0.090 mm (p &lt; 0.001; \u22120.12 to 0.23 mm), and central corneal thickness 0.82 \u00b1 7.12 \u03bcm (p = 0.301; \u221213.1 to 14.8 \u03bcm). For corneal diameter and corneal curvature, mean differences were small (\u22640.07 D) and not statistically significant in most cases. Age was not associated with discrepancies in AL but showed weak correlations with some anterior segment differences, without clear clinical relevance. Conclusions: The HBM-1 demonstrated excellent intrasession repeatability and a good level of clinical agreement with the IOLMaster 700 in a broad population that included children, young adults, and older adults.<\/jats:p>","DOI":"10.3390\/diagnostics16040526","type":"journal-article","created":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T12:07:06Z","timestamp":1770725226000},"page":"526","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Clinical Comparative Evaluation of Two New-Generation Optical Biometers: Intrasession Repeatability and Agreement of Biometric Parameters"],"prefix":"10.3390","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0009-0006-4267-550X","authenticated-orcid":false,"given":"Farid J.","family":"Bedr\u00e1n","sequence":"first","affiliation":[{"name":"Group of Optics and Visual Perception, Department of Optics, Pharmacology and Anatomy, University of Alicante, 03690 Alicante, Spain"},{"name":"Cl\u00ednica de Oftalmolog\u00eda San Diego, Medell\u00edn 050016, Colombia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1546-4807","authenticated-orcid":false,"given":"David P.","family":"Pi\u00f1ero","sequence":"additional","affiliation":[{"name":"Group of Optics and Visual Perception, Department of Optics, Pharmacology and Anatomy, University of Alicante, 03690 Alicante, Spain"},{"name":"Advanced Clinic Optometry Unit, Department of Ophthalmology, Vithas Medimar International, 03016 Alicante, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,2,10]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"196","DOI":"10.4103\/tjosr.tjosr_44_17","article-title":"Update on optical biometry and intraocular lens power calculation","volume":"55","author":"Nazm","year":"2017","journal-title":"TNOA J. Ophthalmic Sci. Res."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"802","DOI":"10.1097\/j.jcrs.0000000000000551","article-title":"Ocular biometry with swept-source optical coherence tomography","volume":"47","year":"2021","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"e94","DOI":"10.1016\/j.ophtha.2020.08.010","article-title":"Intraocular Lens Power Formulas, Biometry, and Intraoperative Aberrometry: A Review","volume":"128","author":"Kane","year":"2021","journal-title":"Ophthalmology"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1167\/iovs.66.9.7","article-title":"IMI\u2014Instrumentation for Myopia Management","volume":"66","author":"Jones","year":"2025","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"ref_5","first-page":"437","article-title":"Agreement and clinical comparison between a new swept-source optical coherence tomography-based optical biometer and an optical low-coherence reflectometry biometer","volume":"31","year":"2016","journal-title":"Eye"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1016\/j.jcrs.2015.07.039","article-title":"Repeatability and agreement in optical biometry of a new swept-source optical coherence tomography-based biometer versus partial coherence interferometry and optical low-coherence reflectometry","volume":"42","author":"Kunert","year":"2016","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1201","DOI":"10.1136\/bjophthalmol-2015-307779","article-title":"Evaluation and comparison of the new swept source OCT-based IOLMaster 700 with the IOLMaster 500","volume":"100","author":"Akman","year":"2016","journal-title":"Br. J. Ophthalmol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1097\/j.jcrs.0000000000000541","article-title":"Comparison of an upgraded optical biometer with 2 validated optical biometers","volume":"47","author":"Kanclerz","year":"2021","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"860","DOI":"10.1111\/opo.13148","article-title":"Feasibility and repeatability of ocular biometry measured with IOLMaster 700 in a large population-based study","volume":"43","author":"Michael","year":"2023","journal-title":"Ophthalmic Physiol. Opt."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Langenbucher, A., Szentm\u00e1ry, N., Cayless, A., Hoffmann, P., Wendelstein, J., and Cooke, D. (2024). Repeatability of biometric measures from the IOLMaster 700 in a cataractous population. PLoS ONE, 19.","DOI":"10.1371\/journal.pone.0297869"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"22151","DOI":"10.1038\/s41598-024-73206-0","article-title":"Evaluation of repeatability and agreement of two optical biometers for intraocular lens power calculation","volume":"14","author":"Alberquilla","year":"2024","journal-title":"Sci. Rep."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1017","DOI":"10.1111\/opo.13332","article-title":"Suitability of multifunction devices Myah and Myopia Master for monitoring myopia progression in children and adults","volume":"44","author":"Chow","year":"2024","journal-title":"Ophthalmic Physiol. Opt."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Mart\u00ednez-Plaza, E., Molina-Mart\u00edn, A., Arias-Puente, A., and Pi\u00f1ero, D.P. (2022). Clinical validation of a new optical biometer for myopia control in a healthy pediatric population. Children, 9.","DOI":"10.3390\/children9111713"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1306","DOI":"10.1055\/a-2117-9335","article-title":"A comparison of optical biometers used in children for myopia control","volume":"240","author":"Mattern","year":"2023","journal-title":"Klin. Monatsbl\u00e4tter Augenheilkd."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1080\/08164622.2022.2152312","article-title":"Repeatability and agreement of swept-source optical coherence tomography and partial coherence interferometry biometers in myopes","volume":"106","author":"Mateos","year":"2023","journal-title":"Clin. Exp. Optom."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1016\/S0886-3350(00)00797-5","article-title":"Power vector analysis of the optical outcome of refractive surgery","volume":"27","author":"Thibos","year":"2001","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1007\/s00417-016-3555-z","article-title":"Evaluation of the repeatability of a swept-source ocular biometer for measuring ocular biometric parameters","volume":"255","author":"Aloy","year":"2017","journal-title":"Graefes Arch. Clin. Exp. Ophthalmol."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"14440","DOI":"10.1038\/s41598-020-71192-7","article-title":"Repeatability, reproducibility, and comparison of ocular biometry using a new optical coherence tomography-based system and another device","volume":"10","author":"Bolek","year":"2020","journal-title":"Sci. Rep."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Yang, C.M., Lim, D.H., Kim, H.J., and Chung, T.Y. (2019). Comparison of two swept-source optical coherence tomography biometers and a partial coherence interferometer. PLoS ONE, 14.","DOI":"10.1371\/journal.pone.0223114"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"153","DOI":"10.4103\/joco.joco_30_23","article-title":"Agreement between a spectral-domain ocular coherence tomography biometer with a swept-source ocular coherence tomography biometer and an optical low-coherence reflectometry biometer in eyes with cataract","volume":"35","author":"Nikpayam","year":"2023","journal-title":"J. Curr. Ophthalmol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"19478","DOI":"10.1038\/s41598-022-24017-8","article-title":"Evaluation of three biometric devices: Ocular parameters and calculated intraocular lens power","volume":"12","author":"Lender","year":"2022","journal-title":"Sci. Rep."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"2912","DOI":"10.7150\/ijms.99907","article-title":"The refractive accuracy between topographic keratometry and biometric keratometry for extended depth-of-focus intraocular lens implantation","volume":"21","author":"Lee","year":"2024","journal-title":"Int. J. Med. Sci."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"2423","DOI":"10.2147\/OPTH.S407538","article-title":"Randomized trial comparing prediction accuracy of two swept source optical coherence tomography biometers","volume":"17","author":"Multack","year":"2023","journal-title":"Clin. Ophthalmol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"257","DOI":"10.3341\/kjo.2017.0091","article-title":"Comparison of ocular biometry using new swept-source optical coherence tomography-based optical biometer with other devices","volume":"32","author":"Cho","year":"2018","journal-title":"Korean J. Ophthalmol."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Ruan, X., Yang, G.Y., Xia, Z., Zhang, J., Gu, X., Tan, Y., Liu, Z., and Luo, L. (2022). Agreement of anterior segment parameter measurements with CASIA 2 and IOLMaster 700. Front. Med., 9.","DOI":"10.3389\/fmed.2022.777443"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"6557","DOI":"10.1038\/s41598-019-42968-3","article-title":"Ocular biometry and refractive outcomes using two swept-source optical coherence tomography-based biometers with segmental or equivalent refractive indices","volume":"9","author":"Omoto","year":"2019","journal-title":"Sci. Rep."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Porwolik, M., Porwolik, A., and Mrukwa-Kominek, E. (2024). Evaluation of selected biometric parameters in cataract patients\u2014A comparison between Argos\u00ae and IOLMaster 700\u00ae: Two swept-source optical coherence tomography-based biometers. Medicina, 60.","DOI":"10.3390\/medicina60071057"},{"key":"ref_28","first-page":"296","article-title":"Comparison of optical biometers ARGOS and IOL Master 700","volume":"77","year":"2021","journal-title":"Ceska Slov. Oftalmol."}],"container-title":["Diagnostics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4418\/16\/4\/526\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T12:24:17Z","timestamp":1770726257000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4418\/16\/4\/526"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,10]]},"references-count":28,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2026,2]]}},"alternative-id":["diagnostics16040526"],"URL":"https:\/\/doi.org\/10.3390\/diagnostics16040526","relation":{},"ISSN":["2075-4418"],"issn-type":[{"value":"2075-4418","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,10]]}}}