{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,9]],"date-time":"2026-11-09T14:01:27Z","timestamp":1794232887793,"version":"4.9.0"},"reference-count":76,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2026,3,16]],"date-time":"2026-03-16T00:00:00Z","timestamp":1773619200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Deanship of Scientific Research (DSR) at King Abdulaziz University, Jeddah, Saudi Arabia","award":["803-142-2025"],"award-info":[{"award-number":["803-142-2025"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Diagnostics"],"abstract":"<jats:p>Objective: To evaluate the performance of photon-counting detector CT (PCD-CT) angiography for the detection and quantification of vascular stenosis. Methods: Web of Science, PubMed, and Cochrane databases were searched from January 1980 to December 2025 to identify studies assessing PCD-CT angiography for the detection and quantification of vascular stenosis, using invasive angiography as the reference standard. The risk of bias of the included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Diagnostic performance metrics, including sensitivity and specificity and quantification values, were extracted from the included studies and a formal narrative synthesis was performed. The meta-analysis included studies reporting true-positive, false-positive, true-negative, and false-negative data. A meta-analysis was conducted only when a minimum of two eligible studies assessed diagnostic performance within the given vascular territory. Statistical analyses were performed using R software (v4.5.0), applying a random-effects model for the meta-analysis. Results: Of 415 identified studies, 20 were included in the systematic review, comprising a total of 9165 participants, with the majority (17\/20, 85%) focusing on coronary artery stenosis. In the meta-analysis of three studies, ultra-high-resolution (UHR) PCD-CT demonstrated excellent diagnostic performance for detecting coronary stenosis for patients with \u226550%, having a pooled sensitivity of 96.1% (95% confidence level (CI): 89.3\u201399.6), specificity of 87.5% (95% CI: 78.2\u201393.3), positive predictive value (PPV) of 91.9% (95% CI: 70.3\u201398.2), and negative predictive value (NPV) of 94.8% (95% CI: 86.0\u201398.6). Compared with conventional energy-integrating detector CT (EID-CT), PCD-CT consistently showed superior diagnostic performance, particularly in the specificity and PPV. In terms of stenosis quantification, PCD-CT showed closer agreement with reference standards than EID-CT, leading to the reclassification of coronary stenosis severity in up to 49% of patients. Evidence for non-coronary vascular territories, including intracranial and peripheral arteries remains limited but suggests promising diagnostic performance. For lower-limb arterial stenosis, the reported sensitivity was 77.4\u201391%, and specificity was 72.1\u201391%. For intracranial in-stent stenosis, PCD-CT demonstrated a sensitivity of 100% and a specificity of 89%. Conclusions: PCD-CT angiography provides high diagnostic performance and improved stenosis quantification for coronary artery stenosis. UHR PCD-CT has excellent diagnostic performance for detecting coronary stenosis and consistently outperforms conventional EID-CT, especially in the specificity and positive predictive value.<\/jats:p>","DOI":"10.3390\/diagnostics16060881","type":"journal-article","created":{"date-parts":[[2026,3,16]],"date-time":"2026-03-16T13:32:07Z","timestamp":1773667927000},"page":"881","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Diagnostic Performance of Photon-Counting CT Angiography in Vascular Stenosis Assessment: A Systematic Review and Meta-Analysis"],"prefix":"10.3390","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3196-2061","authenticated-orcid":false,"given":"Nasser M.","family":"Alzahrani","sequence":"first","affiliation":[{"name":"Radiologic Sciences Department, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Awad","family":"Alzahrani","sequence":"additional","affiliation":[{"name":"Radiologic Sciences Department, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0337-0571","authenticated-orcid":false,"given":"Zyad M.","family":"Almutlaq","sequence":"additional","affiliation":[{"name":"Radiology and Medical Imaging Department, College of Applied Medical Sciences, King Saud Bin Abdulaziz University of Health Sciences, Riyadh P.O. Box 3660, Saudi Arabia"},{"name":"King Abdullah International Medical Research Center, Ministry of National Guard Health Affairs, Riyadh 22384, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmed","family":"Alghamdi","sequence":"additional","affiliation":[{"name":"Diagnostic Radiology Department, College of Applied Medical Sciences, King Khalid University, Abha 61421, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yazeed","family":"Almukhlifi","sequence":"additional","affiliation":[{"name":"Department of Radiological Sciences and Medical Imaging, College of Applied Medical Sciences, Majmaah University, Al Majmaah 15341, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-7798-1168","authenticated-orcid":false,"given":"Sultan A.","family":"Alotaibi","sequence":"additional","affiliation":[{"name":"Department of Radiological Sciences and Medical Imaging, College of Applied Medical Sciences, Majmaah University, Al Majmaah 15341, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaber","family":"Alyami","sequence":"additional","affiliation":[{"name":"Radiologic Sciences Department, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah, Saudi Arabia"},{"name":"King Fahd Medical Research Center, King Abdulaziz University, Jeddah 22252, Saudi Arabia"},{"name":"Smart Medical Imaging Research Group, King Abdulaziz University, Jeddah 22252, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,3,16]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"2982","DOI":"10.1016\/j.jacc.2020.11.010","article-title":"Global Burden of Cardiovascular Diseases and Risk Factors, 1990\u20132019","volume":"76","author":"Roth","year":"2020","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"17767","DOI":"10.1007\/s00521-024-10199-x","article-title":"Machine learning applications for vascular stenosis detection in computed tomography angiography: A systematic review and meta-analysis","volume":"36","author":"Anwer","year":"2024","journal-title":"Neural Comput. Appl."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1016\/j.rcl.2020.02.011","article-title":"Updates in Vascular Computed Tomography","volume":"58","author":"Rajiah","year":"2020","journal-title":"Radiol. Clin. N. Am."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Meloni, A., Cademartiri, F., Pistoia, L., Degiorgi, G., Clemente, A., De Gori, C., Positano, V., Celi, S., Berti, S., and Emdin, M. (2023). Dual-Source Photon-Counting Computed Tomography-Part III: Clinical Overview of Vascular Applications beyond Cardiac and Neuro Imaging. J. Clin. Med., 12.","DOI":"10.3390\/jcm12113798"},{"key":"ref_5","first-page":"e596","article-title":"2019 ACC\/AHA Guideline on the Primary Prevention of Cardiovascular Disease: A Report of the American College of Cardiology\/American Heart Association Task Force on Clinical Practice Guidelines","volume":"140","author":"Arnett","year":"2019","journal-title":"Circulation"},{"key":"ref_6","first-page":"e368","article-title":"2021 AHA\/ACC\/ASE\/CHEST\/SAEM\/SCCT\/SCMR Guideline for the Evaluation and Diagnosis of Chest Pain: A Report of the American College of Cardiology\/American Heart Association Joint Committee on Clinical Practice Guidelines","volume":"144","author":"Gulati","year":"2021","journal-title":"Circulation"},{"key":"ref_7","first-page":"524","article-title":"2021 ESC\/EACTS Guidelines for the management of valvular heart disease: Developed by the Task Force for the management of valvular heart disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS)","volume":"75","author":"Vahanian","year":"2022","journal-title":"Rev. Espa\u00f1ola Cardiol. Engl. Ed."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"e25","DOI":"10.1016\/j.jacc.2020.11.018","article-title":"2020 ACC\/AHA Guideline for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology\/American Heart Association Joint Committee on Clinical Practice Guidelines","volume":"77","author":"Otto","year":"2021","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1111\/j.1755-5922.2010.00155.x","article-title":"In-stent restenosis","volume":"29","author":"Kim","year":"2011","journal-title":"Cardiovasc. Ther."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1016\/j.ejrad.2008.10.025","article-title":"Diagnostic accuracy of 64 multislice CT angiography in the assessment of coronary in-stent restenosis: A meta-analysis","volume":"73","author":"Sun","year":"2010","journal-title":"Eur. J. Radiol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"3101","DOI":"10.1007\/s10554-021-02277-1","article-title":"Lower extremity CT angiography in peripheral arterial disease: From the established approach to evolving technical developments","volume":"37","author":"Shwaiki","year":"2021","journal-title":"Int. J. Cardiovasc. Imaging"},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Cademartiri, F., Meloni, A., Pistoia, L., Degiorgi, G., Clemente, A., Gori, C., Positano, V., Celi, S., Berti, S., and Emdin, M. (2023). Dual-Source Photon-Counting Computed Tomography-Part I: Clinical Overview of Cardiac CT and Coronary CT Angiography Applications. J. Clin. Med., 12.","DOI":"10.3390\/jcm12113627"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1016\/j.jcct.2021.03.007","article-title":"The accuracy of coronary CT angiography in patients with coronary calcium score above 1000 Agatston Units: Comparison with quantitative coronary angiography","volume":"15","author":"Kwan","year":"2021","journal-title":"J. Cardiovasc. Comput. Tomogr."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"e007720","DOI":"10.1161\/CIRCIMAGING.118.007720","article-title":"Contemporary Discrepancies of Stenosis Assessment by Computed Tomography and Invasive Coronary Angiography","volume":"12","author":"Song","year":"2019","journal-title":"Circ. Cardiovasc. Imaging"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1148\/radiol.11110537","article-title":"Coronary artery stenoses: Accuracy of 64-detector row CT angiography in segments with mild, moderate, or severe calcification--a subanalysis of the CORE-64 trial","volume":"261","author":"Vavere","year":"2011","journal-title":"Radiology"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1007\/s00330-009-1555-7","article-title":"Do the cardiovascular risk profile and the degree of arterial wall calcification influence the performance of MDCT angiography of lower extremity arteries?","volume":"20","author":"Meyer","year":"2010","journal-title":"Eur. Radiol."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"e70100","DOI":"10.1111\/echo.70100","article-title":"Value of Ultrahigh-Resolution Photon-Counting Detector Computed Tomography in Cardiac Imaging","volume":"42","author":"Kravchenko","year":"2025","journal-title":"Echocardiography"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"818","DOI":"10.1007\/s00330-005-0062-8","article-title":"64-slice multidetector coronary CT angiography: In vitro evaluation of 68 different stents","volume":"16","author":"Maintz","year":"2006","journal-title":"Eur. Radiol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1097\/RTI.0b013e3181b5d813","article-title":"Evaluation of coronary artery in-stent restenosis by 64-section computed tomography: Factors affecting assessment and accurate diagnosis","volume":"25","author":"Chung","year":"2010","journal-title":"J. Thorac. Imaging"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"2204","DOI":"10.1016\/j.jacc.2007.02.045","article-title":"Usefulness of 64-slice multislice computed tomography coronary angiography to assess in-stent restenosis","volume":"49","author":"Cademartiri","year":"2007","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"2627","DOI":"10.1007\/s00330-019-06357-8","article-title":"CT and MR imaging prior to transcatheter aortic valve implantation: Standardisation of scanning protocols, measurements and reporting\u2014A consensus document by the European Society of Cardiovascular Radiology (ESCR)","volume":"30","author":"Francone","year":"2020","journal-title":"Eur. Radiol."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"338","DOI":"10.1016\/j.jcct.2017.06.001","article-title":"CT angiography to evaluate coronary artery disease and revascularization requirement before trans-catheter aortic valve replacement","volume":"11","author":"Rossi","year":"2017","journal-title":"J. Cardiovasc. Comput. Tomogr."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"536","DOI":"10.1016\/j.jcct.2022.07.002","article-title":"CAD-RADS\u2122 2.0\u20142022 Coronary Artery Disease-Reporting and Data System: An Expert Consensus Document of the Society of Cardiovascular Computed Tomography (SCCT), the American College of Cardiology (ACC), the American College of Radiology (ACR), and the North America Society of Cardiovascular Imaging (NASCI)","volume":"16","author":"Cury","year":"2022","journal-title":"J. Cardiovasc. Comput. Tomogr."},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Meloni, A., Frijia, F., Panetta, D., Degiorgi, G., De Gori, C., Maffei, E., Clemente, A., Positano, V., and Cademartiri, F. (2023). Photon-Counting Computed Tomography (PCCT): Technical Background and Cardio-Vascular Applications. Diagnostics, 13.","DOI":"10.3390\/diagnostics13040645"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1148\/radiol.2018172656","article-title":"Photon-counting CT: Technical Principles and Clinical Prospects","volume":"289","author":"Willemink","year":"2018","journal-title":"Radiology"},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Tortora, M., Gemini, L., D\u2019Iglio, I., Ugga, L., Spadarella, G., and Cuocolo, R. (2022). Spectral Photon-Counting Computed Tomography: A Review on Technical Principles and Clinical Applications. J. Imaging, 8.","DOI":"10.3390\/jimaging8040112"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"2362","DOI":"10.1016\/j.acra.2023.05.029","article-title":"Photon Counting CT: Technical Principles, Clinical Applications, and Future Prospects","volume":"30","author":"Wu","year":"2023","journal-title":"Acad. Radiol."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1097\/RLI.0000000000001109","article-title":"Quantification of Coronary Artery Stenosis in Very-High-Risk Patients Using Ultra-High Resolution Spectral Photon-Counting CT","volume":"60","author":"Fahrni","year":"2025","journal-title":"Investig. Radiol."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"111834","DOI":"10.1016\/j.ejrad.2024.111834","article-title":"Diagnostic performance of Photon-counting CT angiography in peripheral artery disease compared to DSA as gold standard","volume":"182","author":"Ghibes","year":"2025","journal-title":"Eur. J. Radiol."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1016\/j.jcmg.2024.11.005","article-title":"Benchmarking Photon-Counting Computed Tomography Angiography Against Invasive Assessment of Coronary Stenosis: Implications for Severely Calcified Coronaries","volume":"18","author":"Kotronias","year":"2025","journal-title":"JACC Cardiovasc. Imaging"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"n71","DOI":"10.1136\/bmj.n71","article-title":"The PRISMA 2020 statement: An updated guideline for reporting systematic reviews","volume":"372","author":"Page","year":"2021","journal-title":"BMJ"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"529","DOI":"10.7326\/0003-4819-155-8-201110180-00009","article-title":"QUADAS-2: A revised tool for the quality assessment of diagnostic accuracy studies","volume":"155","author":"Whiting","year":"2011","journal-title":"Ann. Intern. Med."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1136\/bmj.327.7414.557","article-title":"Measuring inconsistency in meta-analyses","volume":"327","author":"Higgins","year":"2003","journal-title":"BMJ"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"2973","DOI":"10.1016\/j.acra.2024.02.008","article-title":"Photon-Counting Detector CT Angiography Versus Digital Subtraction Angiography in Patients with Peripheral Arterial Disease","volume":"31","author":"Augustin","year":"2024","journal-title":"Acad. Radiol."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1007\/s10554-024-03273-x","article-title":"Diagnostic performance of high and ultra-high-resolution photon counting CT for detection of coronary artery disease in patients evaluated for transcatheter aortic valve implantation","volume":"42","author":"Sharma","year":"2024","journal-title":"Int. J. Cardiovasc. Imaging"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"112154","DOI":"10.1016\/j.ejrad.2025.112154","article-title":"Ultra-high resolution photon-counting detector coronary CT minimizes overestimation bias compared to invasive reference","volume":"188","author":"Laux","year":"2025","journal-title":"Eur. J. Radiol."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"6568","DOI":"10.1007\/s00330-024-10760-1","article-title":"Improvement of coronary stent visualization using ultra-high-resolution photon-counting detector CT","volume":"34","author":"Qin","year":"2024","journal-title":"Eur. Radiol."},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Boussoussou, M., Vecsey-Nagy, M., Jokkel, Z., Vattay, B., Kubovje, A., Sipos, B., Kolossv\u00e1ry, M., Nagy, A.I., Sz\u00e1raz, L., and Beke, S. (2025). Comparative analysis of photon-counting and energy-integrating detector CT to identify obstructive coronary artery disease. Eur. Radiol.","DOI":"10.1007\/s00330-025-12118-7"},{"key":"ref_39","doi-asserted-by":"crossref","unstructured":"Mergen, V., Rusek, S., Civaia, F., Rossi, P., Rajagopal, R., B\u00e4ttig, E., Manka, R., Candreva, A., Eberhard, M., and Alkadhi, H. (2024). Virtual calcium removal in calcified coronary arteries with photon-counting detector CT-first in-vivo experience. Front. Cardiovasc. Med., 11.","DOI":"10.3389\/fcvm.2024.1367463"},{"key":"ref_40","first-page":"e017112","article-title":"Intraindividual Comparison of Ultrahigh-Spatial-Resolution Photon-Counting Detector CT and Energy-Integrating Detector CT for Coronary Stenosis Measurement","volume":"17","author":"Tremamunno","year":"2024","journal-title":"Circ. Cardiovasc. Imaging"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"e2330481","DOI":"10.2214\/AJR.23.30481","article-title":"Photon-Counting Detector CT Virtual Monoenergetic Images for Coronary Artery Stenosis Quantification: Phantom and In Vivo Evaluation","volume":"222","author":"Wolf","year":"2024","journal-title":"AJR Am. J. Roentgenol."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"669","DOI":"10.1007\/s00062-025-01519-2","article-title":"Photon-Counting CT-Angiography to Assess Intracranial Stents and Flow Diverters in Comparison to Digital Subtraction Angiography","volume":"35","author":"Wuyts","year":"2025","journal-title":"Clin. Neuroradiol."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1016\/j.diii.2024.01.010","article-title":"Coronary artery disease evaluation during transcatheter aortic valve replacement work-up using photon-counting CT and artificial intelligence","volume":"105","author":"Brendel","year":"2024","journal-title":"Diagn Interv. Imaging"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"e223305","DOI":"10.1148\/radiol.223305","article-title":"Accuracy of Ultrahigh-Resolution Photon-counting CT for Detecting Coronary Artery Disease in a High-Risk Population","volume":"307","author":"Hagar","year":"2023","journal-title":"Radiology"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"4273","DOI":"10.1007\/s00330-023-10516-3","article-title":"Ultra-high-resolution photon-counting detector CT in evaluating coronary stent patency: A comparison to invasive coronary angiography","volume":"34","author":"Hagar","year":"2024","journal-title":"Eur. Radiol."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1016\/j.jacc.2024.10.069","article-title":"Diagnostic Performance and Clinical Impact of Photon-Counting Detector Computed Tomography in Coronary Artery Disease","volume":"85","author":"Sakai","year":"2025","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Soschynski, M., Hagen, F., Baumann, S., Hagar, M.T., Weiss, J., Krauss, T., Schlett, C.L., von Zur M\u00fchlen, C., Bamberg, F., and Nikolaou, K. (2022). High Temporal Resolution Dual-Source Photon-Counting CT for Coronary Artery Disease: Initial Multicenter Clinical Experience. J. Clin. Med., 11.","DOI":"10.3390\/jcm11206003"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"e2533021","DOI":"10.2214\/AJR.25.33021","article-title":"Photon-Counting Detector CTA in Standard- and Ultrahigh-Resolution Modes for Diagnosing Coronary Artery Stenosis Using Invasive Angiography as the Reference: A Prospective Study","volume":"225","author":"Wang","year":"2025","journal-title":"AJR Am. J. Roentgenol."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"111354","DOI":"10.1016\/j.ejrad.2024.111354","article-title":"Diagnostic improvements of calcium-removal image reconstruction algorithm using photon-counting detector CT for calcified coronary lesions","volume":"172","author":"Nishihara","year":"2024","journal-title":"Eur. J. Radiol."},{"key":"ref_50","doi-asserted-by":"crossref","unstructured":"Demmert, T.T., Klambauer, K., Moser, L.J., Michel, J., Kasel, M., Manka, R., Mergen, V., Flohr, T., Eberhard, M., and Alkadhi, H. (2025). Ultra-high resolution photon-counting detector coronary CT angiography: Diagnostic accuracy in patients with high Agatston scores. Eur. Radiol., Online ahead of print.","DOI":"10.1007\/s00330-025-12158-z"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1148\/radiol.211780","article-title":"Coronary CT Angiography with Photon-counting CT: First-In-Human Results","volume":"303","author":"Boccalini","year":"2022","journal-title":"Radiology"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"3322","DOI":"10.1093\/eurheartj\/ehy267","article-title":"The performance of non-invasive tests to rule-in and rule-out significant coronary artery stenosis in patients with stable angina: A meta-analysis focused on post-test disease probability","volume":"39","author":"Knuuti","year":"2018","journal-title":"Eur. Heart J."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1016\/j.jcct.2020.11.001","article-title":"SCCT 2021 Expert Consensus Document on Coronary Computed Tomographic Angiography: A Report of the Society of Cardiovascular Computed Tomography","volume":"15","author":"Narula","year":"2021","journal-title":"J. Cardiovasc. Comput. Tomogr."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"961","DOI":"10.1093\/ehjci\/jeu027","article-title":"The diagnostic accuracy and outcomes after coronary computed tomography angiography vs. conventional functional testing in patients with stable angina pectoris: A systematic review and meta-analysis","volume":"15","author":"Nielsen","year":"2014","journal-title":"Eur. Heart J. Cardiovasc. Imaging"},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"713","DOI":"10.1016\/j.jacc.2021.06.019","article-title":"Coronary Computed Tomographic Angiography for Complete Assessment of Coronary Artery Disease","volume":"78","author":"Serruys","year":"2021","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"943","DOI":"10.1007\/s10554-011-9902-6","article-title":"Influence of coronary calcification on the diagnostic accuracy of 64-slice computed tomography coronary angiography: A systematic review and meta-analysis","volume":"28","author":"Abdulla","year":"2012","journal-title":"Int. J. Cardiovasc. Imaging"},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1007\/s10554-025-03491-x","article-title":"Cardiac imaging using photon counting CT\u2014Benefits, challenges and prospects","volume":"42","author":"Rajendran","year":"2025","journal-title":"Int. J. Cardiovasc. Imaging"},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"e240338","DOI":"10.1148\/ryct.240338","article-title":"Coronary Stent Imaging with Photon-counting Detector CT","volume":"7","author":"Sharma","year":"2025","journal-title":"Radiol. Cardiothorac. Imaging"},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1016\/j.ejrad.2009.05.030","article-title":"Diagnostic accuracy of 64-slice multidetector CT for detection of in-stent restenosis in an unselected, consecutive patient population","volume":"76","author":"Haraldsdottir","year":"2010","journal-title":"Eur. J. Radiol."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"1677","DOI":"10.1007\/s00330-011-2099-1","article-title":"Dual-energy CT angiography in peripheral arterial occlusive disease\u2014Accuracy of maximum intensity projections in clinical routine and subgroup analysis","volume":"21","author":"Kau","year":"2011","journal-title":"Eur. Radiol."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"e2329778","DOI":"10.2214\/AJR.23.29778","article-title":"Infrapopliteal Segments on Lower Extremity CTA: Prospective Intraindividual Comparison of Energy-Integrating Detector CT and Photon-Counting Detector CT","volume":"222","author":"Yalon","year":"2024","journal-title":"Am. J. Roentgenol."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1186\/s41747-025-00656-0","article-title":"Ultra-high spatial resolution at photon-counting computed tomography: Technical insights and sustainable applications in cardiothoracic imaging","volume":"10","author":"Occhipinti","year":"2026","journal-title":"Eur. Radiol. Exp."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1016\/j.jcmg.2023.10.004","article-title":"Coronary Stenosis Quantification With Ultra-High-Resolution Photon-Counting Detector CT Angiography: Comparison With 3D Quantitative Coronary Angiography","volume":"17","author":"Eberhard","year":"2024","journal-title":"JACC Cardiovasc. Imaging"},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.jcct.2023.11.079","article-title":"Photon-counting detector CT reduces the rate of referrals to invasive coronary angiography as compared to CT with whole heart coverage energy-integrating detector","volume":"18","author":"Simon","year":"2024","journal-title":"J. Cardiovasc. Comput. Tomogr."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/j.jcct.2023.10.009","article-title":"Coronary artery stenosis quantification in patients with dense calcifications using ultra-high-resolution photon-counting-detector computed tomography","volume":"18","author":"Koons","year":"2024","journal-title":"J. Cardiovasc. Comput. Tomogr."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"e231956","DOI":"10.1148\/radiol.231956","article-title":"Ultrahigh-Spatial-Resolution Photon-counting Detector CT Angiography of Coronary Artery Disease for Stenosis Assessment","volume":"310","author":"Halfmann","year":"2024","journal-title":"Radiology"},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"1591","DOI":"10.1056\/NEJMoa2200963","article-title":"CT or invasive coronary angiography in stable chest pain","volume":"386","author":"Group","year":"2022","journal-title":"N. Engl. J. Med."},{"key":"ref_68","first-page":"160","article-title":"The Impact and Pathophysiologic Consequences of Coronary Artery Calcium Deposition in Percutaneous Coronary Interventions","volume":"28","author":"Lee","year":"2016","journal-title":"J. Invasive Cardiol."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1097\/RLI.0000000000000961","article-title":"High-Pitch Multienergy Coronary CT Angiography in Dual-Source Photon-Counting Detector CT Scanner at Low Iodinated Contrast Dose","volume":"58","author":"Rajiah","year":"2023","journal-title":"Investig. Radiol."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1097\/RLI.0000000000000610","article-title":"Spectral Photon-Counting Computed Tomography for Coronary Stent Imaging: Evaluation of the Potential Clinical Impact for the Delineation of In-Stent Restenosis","volume":"55","author":"Bratke","year":"2020","journal-title":"Investig. Radiol."},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1097\/RLI.0000000000000853","article-title":"Photon-Counting Detector CT-Based Vascular Calcium Removal Algorithm: Assessment Using a Cardiac Motion Phantom","volume":"57","author":"Allmendinger","year":"2022","journal-title":"Investig. Radiol."},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"6211","DOI":"10.1007\/s00330-021-08092-5","article-title":"Subtraction improves the accuracy of coronary CT angiography for detecting obstructive disease in severely calcified segments","volume":"31","author":"Xu","year":"2021","journal-title":"Eur. Radiol."},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"2794","DOI":"10.1007\/s00330-016-4675-x","article-title":"Diagnostic performance of calcification-suppressed coronary CT angiography using rapid kilovolt-switching dual-energy CT","volume":"27","author":"Yunaga","year":"2017","journal-title":"Eur. Radiol."},{"key":"ref_74","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1007\/s10554-025-03392-z","article-title":"Assessing beam hardening artifacts in coronary stent imaging using different CT acquisition parameters on photon-counting detector computed tomography","volume":"42","author":"Adolf","year":"2025","journal-title":"Int. J. Cardiovasc. Imaging"},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"4089","DOI":"10.1007\/s00330-023-10403-x","article-title":"Reduction of contrast medium for transcatheter aortic valve replacement planning using a spectral detector CT: A prospective clinical trial","volume":"34","author":"Langenbach","year":"2024","journal-title":"Eur. Radiol."},{"key":"ref_76","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1016\/j.acra.2023.06.025","article-title":"Saving Contrast Media in Coronary CT Angiography with Photon-Counting Detector CT","volume":"31","author":"Cundari","year":"2024","journal-title":"Acad. Radiol."}],"container-title":["Diagnostics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4418\/16\/6\/881\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,16]],"date-time":"2026-03-16T13:49:10Z","timestamp":1773668950000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4418\/16\/6\/881"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,16]]},"references-count":76,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2026,3]]}},"alternative-id":["diagnostics16060881"],"URL":"https:\/\/doi.org\/10.3390\/diagnostics16060881","relation":{},"ISSN":["2075-4418"],"issn-type":[{"value":"2075-4418","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,16]]}}}