{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T22:09:05Z","timestamp":1789769345747,"version":"4.0.1"},"reference-count":40,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2026,3,20]],"date-time":"2026-03-20T00:00:00Z","timestamp":1773964800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Diagnostics"],"abstract":"<jats:p>Molecular point-of-care testing (POCT) for respiratory infections has undergone remarkable advancement over the past two decades, driven by technological innovation and urgent clinical needs highlighted by the COVID-19 pandemic. This comprehensive systematic review was conducted following PRISMA 2020 guidelines, synthesizing evidence from 254 peer-reviewed studies published between 2006 and 2026, with detailed analysis of the 30 most relevant papers selected through a rigorous four-stage screening process. The review examines the evolution of molecular POCT technologies, including reverse transcription polymerase chain reaction (RT-PCR), loop-mediated isothermal amplification (LAMP), recombinase polymerase amplification (RPA), and CRISPR-based detection systems. Key findings demonstrate that modern molecular POCT platforms achieve diagnostic performance comparable to laboratory-based testing, with sensitivities ranging from 88% to 100% and specificities from 98% to 100%, while delivering results in 15 to 80 min. These technologies enable rapid, accurate detection of major respiratory pathogens, including SARS-CoV-2, influenza A\/B, respiratory syncytial virus (RSV), and atypical bacteria. The integration of microfluidic systems, portable devices, and smartphone-based analysis has expanded access to testing in resource-limited settings, emergency departments, and wearable platforms. This review provides critical insights for clinicians, researchers, and policymakers regarding the current state, clinical applications, and future directions of molecular POCT for respiratory infections.<\/jats:p>","DOI":"10.3390\/diagnostics16060930","type":"journal-article","created":{"date-parts":[[2026,3,20]],"date-time":"2026-03-20T17:02:43Z","timestamp":1774026163000},"page":"930","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Molecular Point-of-Care Testing for Respiratory Infections: A Comprehensive Literature Review (2006\u20132026)"],"prefix":"10.3390","volume":"16","author":[{"given":"Ahmed J.","family":"Alzahrani","sequence":"first","affiliation":[{"name":"College of Medicine, Al-Imam Mohammed Ibn Saud Islamic University, Riyadh 11432, Saudi Arabia"},{"name":"Laboratory Department, Dr. Sulaiman Al Habib Medical Group, Riyadh 11372, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,3,20]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"105706","DOI":"10.1016\/j.jcv.2024.105706","article-title":"Clinical performance of the Roche Cobas Liat SARS-CoV-2 & influenza A\/B assay: A systematic review and meta-analysis","volume":"175","author":"Chang","year":"2024","journal-title":"J. Clin. Virol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"e0145924","DOI":"10.1128\/jcm.01459-24","article-title":"A multicenter study to assess the performance of the point-of-care RT-PCR Cobas SARS-CoV-2 & Influenza A\/B nucleic acid test for use on the Cobas Liat system in comparison with centralized assays across healthcare facilities in the United States","volume":"63","author":"Robbins","year":"2025","journal-title":"J. Clin. Microbiol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1453","DOI":"10.1007\/s10096-020-03860-5","article-title":"Performance and ease of use of a molecular point-of-care test for influenza A\/B and RSV in patients presenting to primary care","volume":"39","author":"Verbakel","year":"2020","journal-title":"Eur. J. Clin. Microbiol. Infect. Dis."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Abdullah, A., Sam, I.-C., Ong, Y.J., Theo, C.H., Pukhari, M.H., and Chan, Y.F. (2023). Comparative Evaluation of a Standard M10 Assay with Xpert Xpress for the Rapid Molecular Diagnosis of SARS-CoV-2, Influenza A\/B Virus, and Respiratory Syncytial Virus. Diagnostics, 13.","DOI":"10.20944\/preprints202309.1037.v1"},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Domnich, A., Orsi, A., Trombetta, C.-S., Costa, E., Guarona, G., Lucente, M., Ricucci, V., Bruzzone, B., and Icardi, G. (2022). Comparative Diagnostic Accuracy of the STANDARD M10 Assay for the Molecular Diagnosis of SARS-CoV-2 in the Point-of-Care and Critical Care Settings. J. Clin. Med., 11.","DOI":"10.3390\/jcm11092465"},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Maignan, M., Viglino, D., Hablot, M., Masson, N.T., Lebeugle, A., Muret, R.C., Makele, P.M., Guglielmetti, V., Morand, P., and Lupo, J. (2019). Diagnostic accuracy of a rapid RT-PCR assay for point-of-care detection of influenza A\/B virus at emergency department admission: A prospective evaluation during the 2017\/2018 influenza season. PLoS ONE, 14.","DOI":"10.1371\/journal.pone.0216308"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"e0203324","DOI":"10.1128\/spectrum.02033-24","article-title":"Clinical performance of Abbott ID NOW\u2122 COVID-19 2.0 rapid molecular point-of-care test compared to three real-time RT-PCR assays","volume":"13","author":"Bowie","year":"2025","journal-title":"Microbiol. Spectr."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Jee, H., Choi, M., Park, I.S., Lee, J., Jang, W.S., and Lim, C.S. (2023). Simple Point-of-Care Nucleic Acid Amplification Test for Rapid SARS-CoV-2 Infection Diagnosis. Diagnostics, 13.","DOI":"10.3390\/diagnostics13183001"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1186\/s12985-020-01435-6","article-title":"Rapid point-of-care detection of SARS-CoV-2 using reverse transcription loop-mediated isothermal amplification (RT-LAMP)","volume":"17","author":"Mautner","year":"2020","journal-title":"Virol. J."},{"key":"ref_10","first-page":"708","article-title":"A One-Pot RT-LAMP Diagnostic Assay for SARS-CoV 2 from Saliva Samples","volume":"5","author":"Mora","year":"2025","journal-title":"ACS Meas. Sci. Au"},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Garneret, P., Coz, E., Martin, E., Manuguerra, J.-C., Brient-Litzler, E., Enouf, V., Obando, D.F.G., Olivo-Marin, J.-C., Monti, F., and van der Werf, S. (2020). Highly performing point-of-care molecular testing for SARS-CoV-2 with RNA extraction and isothermal amplification. medRxiv.","DOI":"10.1101\/2020.08.01.20166538"},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Kshirsagar, A., DeRosa, D., Politza, A.J., Liu, T., Dong, M., and Guan, W. (2025). Point-Of-Need One-Pot Multiplexed RT-LAMP Test for Detecting Three Common Respiratory Viruses in Saliva. Biosens. Bioelectron., 288.","DOI":"10.1016\/j.bios.2025.117836"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"4058","DOI":"10.1021\/acssensors.4c00992","article-title":"Point-of-Care Multiplex Detection of Respiratory Viruses","volume":"9","author":"Lim","year":"2024","journal-title":"ACS Sens."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"3507","DOI":"10.1039\/C8LC00841H","article-title":"Rapid detection of multiple respiratory viruses based on microfluidic isothermal amplification and a real-time colorimetric method","volume":"18","author":"Wang","year":"2018","journal-title":"Lab Chip"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"113167","DOI":"10.1016\/j.bios.2021.113167","article-title":"Rapid and sensitive multiplex molecular diagnosis of respiratory pathogens using plasmonic isothermal RPA array chip","volume":"193","author":"Woo","year":"2021","journal-title":"Biosens. Bioelectron."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"2467","DOI":"10.1007\/s15010-025-02581-1","article-title":"Evaluation of an internet of things device for isothermal molecular detection","volume":"53","author":"Weidmann","year":"2025","journal-title":"Infection"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"118269","DOI":"10.1016\/j.bios.2025.118269","article-title":"Smart bioelectronic facemask for non-invasive detection of respiratory infections","volume":"271","author":"Shi","year":"2026","journal-title":"Biosens. Bioelectron."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"001519","DOI":"10.1099\/jmm.0.001519","article-title":"An isothermal amplification-coupled dipstick for the rapid detection of COVID-19","volume":"71","author":"Shanmugakani","year":"2022","journal-title":"J. Med. Microbiol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"117244","DOI":"10.1016\/j.diagmicrobio.2025.117244","article-title":"Rapid detection of respiratory syncytial virus using RT-LAMP-CRISPR\/Cas12b on a gravity-driven microfluidic chip","volume":"111","author":"Liu","year":"2026","journal-title":"Diagn. Microbiol. Infect. Dis."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Dorta-Gorr\u00edn, A., Navas-M\u00e9ndez, J., Gozalo-Marg\u00fcello, M., Miralles, L., and Garc\u00eda-Hevia, L. (2023). Detection of SARS-CoV-2 based on nucleic acid amplification tests (NAATs) and its integration into nanomedicine and microfluidic devices as point-of-care testing. Int. J. Mol. Sci., 24.","DOI":"10.3390\/ijms241210233"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1552","DOI":"10.1039\/D4LC00704B","article-title":"A Sample-to-answer Digital Microfluidic Multiplexed PCR System for Syndromic Pathogen Detection in Respiratory Tract Infection","volume":"25","author":"Bai","year":"2025","journal-title":"Lab Chip"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"117194","DOI":"10.1016\/j.bios.2025.117194","article-title":"Portable, quantitative, real-time isothermal nucleic acid amplification test using microfluidic device-coupled UV-LED photodiode detector","volume":"270","author":"Kumar","year":"2025","journal-title":"Biosens. Bioelectron."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Van Ngoc, H., Quyen, T.L., Vinayaka, A.C., Bang, D.D., and Wolff, A. (2022). Point-of-care system for rapid real-time detection of SARS-CoV-2 virus based on commercially available Arduino platforms. Front. Bioeng. Biotechnol., 10.","DOI":"10.3389\/fbioe.2022.917573"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"116765","DOI":"10.1016\/j.jpba.2025.116765","article-title":"An ultra-sensitive, multiplexed, and cost-effective POCT system for the detection of co-infecting respiratory viruses, including SARS-CoV-2, Flu A, Flu B, and RSV, within 30 min","volume":"260","author":"Chen","year":"2025","journal-title":"J. Pharm. Biomed. Anal."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"727","DOI":"10.1056\/NEJMoa2001017","article-title":"A Novel Coronavirus from Patients with Pneumonia in China, 2019","volume":"382","author":"Zhu","year":"2020","journal-title":"N. Engl. J. Med."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"e00926-20","DOI":"10.1128\/JCM.00926-20","article-title":"Multicenter Evaluation of the Cepheid Xpert Xpress SARS-CoV-2 Test","volume":"58","author":"Loeffelholz","year":"2020","journal-title":"J. Clin. Microbiol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"e59","DOI":"10.1093\/labmed\/lmaa039","article-title":"Types of Assays for SARS-CoV-2 Testing: A Review","volume":"51","author":"Smithgall","year":"2020","journal-title":"Lab. Med."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1391","DOI":"10.1007\/s10142-022-00900-5","article-title":"Colorimetric and fluorometric reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for diagnosis of SARS-CoV-2","volume":"22","author":"Alhamid","year":"2022","journal-title":"Funct. Integr."},{"key":"ref_29","first-page":"45","article-title":"Development and Clinical Validation of a Rapid One-Step Reverse Transcription Loop-Mediated Isothermal Amplification Assay for Detection of SARS-CoV-2","volume":"51","author":"Hanifehpour","year":"2024","journal-title":"Mol. Biol. Rep."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Lau, Y.L., Ismail, I., Mustapa, N.I., Lai, M.Y., Tuan Soh, T.S., Hassan, A., Peariasamy, K.M., Lee, Y.L., Lim, L.H., and Khor, C.S. (2021). Development of a Reverse Transcription Recombinase Polymerase Amplification Assay for Rapid and Direct Visual Detection of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2). PLoS ONE, 16.","DOI":"10.1371\/journal.pone.0249100"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"858806","DOI":"10.3389\/fmicb.2022.858806","article-title":"Development of a Rapid and Efficient RPA-CRISPR\/Cas12a Assay for Mycoplasma pneumoniae Detection","volume":"13","author":"Li","year":"2022","journal-title":"Front Microbiol."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1093\/infdis\/jiaa641","article-title":"Rapid, Sensitive and Specific SARS Coronavirus-2 Detection: A Multi-Center Comparison Between Standard qRT-PCR and CRISPR Based DETECTR","volume":"223","author":"Brandsma","year":"2021","journal-title":"J. Infect. Dis."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1528","DOI":"10.1128\/JCM.03368-12","article-title":"Comparison of the Biofire FilmArray RP, Genmark eSensor RVP, Luminex xTAG RVPv1, and Luminex xTAG RVP Fast Multiplex Assays for Detection of Respiratory Viruses","volume":"51","author":"Popowitch","year":"2013","journal-title":"J. Clin. Microbiol."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"e01691-17","DOI":"10.1128\/JCM.01691-17","article-title":"Parallel Validation of Three Molecular Devices for Simultaneous Detection and Identification of Influenza A, B and Respiratory Syncytial Viruses","volume":"56","author":"Ling","year":"2018","journal-title":"J. Clin. Microbiol."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"897","DOI":"10.3109\/00365548.2014.951681","article-title":"Comparison of the FilmArray assay and in-house real-time PCR for detection of respiratory infection","volume":"46","author":"Andersson","year":"2014","journal-title":"Scand. J. Infect. Dis."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1111\/avj.70022","article-title":"Real-time fluorometric isothermal assays for detection of Streptococcus equi subspecies equi and Streptococcus equi subspecies zooepidemicus in horses: Validation, comparison and evaluation of their clinical application","volume":"104","author":"Jelocnik","year":"2025","journal-title":"Aust. Vet. J."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"855","DOI":"10.1007\/s10096-025-05370-8","article-title":"Impact of point-of-care multiplex PCR for Mycoplasma pneumoniae community-acquired pneumonia in the emergency department","volume":"45","author":"Guenezan","year":"2025","journal-title":"Eur. J. Clin. Microbiol. Infect. Dis."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"e53","DOI":"10.1093\/labmed\/lmx038","article-title":"Prospective and Retrospective Evaluation of the Performance of the FDA-Approved Cepheid Xpert Flu\/RSV XC Assay","volume":"48","author":"Arbefeville","year":"2017","journal-title":"Lab. Med."},{"key":"ref_39","doi-asserted-by":"crossref","unstructured":"Andrews, D., Chetty, Y., Cooper, B.S., Virk, M., Glass, S.K., Letters, A., Kelly, P.A., Sudhanva, M., and Jeyaratnam, D. (2017). Multiplex PCR point of care testing versus routine, laboratory-based testing in the treatment of adults with respiratory tract infections: A quasi-randomised study assessing impact on length of stay and antimicrobial use. BMC Infect. Dis., 17.","DOI":"10.1186\/s12879-017-2784-z"},{"key":"ref_40","doi-asserted-by":"crossref","unstructured":"Brendish, N.J., Malachira, A.K., and Clark, T.W. (2017). Molecular point-of-care testing for respiratory viruses versus routine clinical care in adults with acute respiratory illness presenting to secondary care: A pragmatic randomised controlled trial. BMC Infect. Dis., 17.","DOI":"10.1186\/s12879-017-2219-x"}],"container-title":["Diagnostics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4418\/16\/6\/930\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,25]],"date-time":"2026-03-25T05:16:45Z","timestamp":1774415805000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4418\/16\/6\/930"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,20]]},"references-count":40,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2026,3]]}},"alternative-id":["diagnostics16060930"],"URL":"https:\/\/doi.org\/10.3390\/diagnostics16060930","relation":{},"ISSN":["2075-4418"],"issn-type":[{"value":"2075-4418","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,20]]}}}