{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T22:06:42Z","timestamp":1790633202272,"version":"4.1.0"},"reference-count":30,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T00:00:00Z","timestamp":1780358400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Diagnostics"],"abstract":"<jats:p>Background\/Objectives: Weaning failure from mechanical ventilation affects 10\u201320% of critically ill patients. Cardiovascular dysfunction\u2014particularly diastolic dysfunction with elevated left atrial pressure (LAP)\u2014underlies up to 50\u201360% of failed spontaneous breathing trials (SBTs) and frequently remains undetected without targeted echocardiographic assessment. This narrative review synthesises current evidence on the echocardiographic evaluation of weaning failure, with emphasis on LAP estimation, right ventricular (RV) dysfunction, and the integration of lung and diaphragm ultrasound. Methods: A structured literature search of PubMed\/MEDLINE and EMBASE was performed for publications from January 2000 to April 2026, supplemented by hand-searching of reference lists and current society guidelines. This article is reported as a narrative review; no formal systematic review protocol was registered. A qualitative synthesis emphasising pathophysiological mechanisms, echocardiographic phenotypes, and clinical applicability was performed. Results: Positive pressure ventilation with PEEP provides active LV afterload reduction; extubation abruptly removes this unloading and may precipitate acute filling pressure elevation in vulnerable patients. Multiparametric echocardiographic LAP assessment\u2014integrating the E\/e\u2019 ratio, deceleration time, and pulmonary vein flow\u2014supports pre-extubation risk stratification. The dynamic PEEP reduction test, although not yet standardised or multicentre-validated, may identify patients with load-dependent cardiac decompensation before extubation. RV dysfunction is present in 20\u201350% of ventilated patients and worsens weaning outcomes through ventricular interdependence. Complementary lung ultrasound B-line quantification and diaphragm thickening fraction assessment together support a phenotype-specific diagnostic approach. Conclusions: A structured multimodal ultrasound framework integrating echocardiography, lung ultrasound, and diaphragm ultrasound may support identification and targeted treatment of the dominant mechanism of weaning failure before extubation. Prospective multicentre validation of the integrated protocol as a whole remains a priority research need.<\/jats:p>","DOI":"10.3390\/diagnostics16111709","type":"journal-article","created":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T10:14:57Z","timestamp":1780395297000},"page":"1709","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Beyond the Spontaneous Breathing Trial: Echocardiographic and Integrated Ultrasound Assessment During Weaning from Mechanical Ventilation"],"prefix":"10.3390","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0646-0465","authenticated-orcid":false,"given":"Saeed","family":"Torabi","sequence":"first","affiliation":[{"name":"Department of Anaesthesiology and Intensive Care Medicine, University Hospital of Cologne, Faculty of Medicine, University of Cologne, 50937 Cologne, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-4907-1852","authenticated-orcid":false,"given":"Philipp K.","family":"Omuro","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology and Intensive Care Medicine, University Hospital of Cologne, Faculty of Medicine, University of Cologne, 50937 Cologne, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,6,2]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1033","DOI":"10.1183\/09031936.00010206","article-title":"Weaning from mechanical ventilation","volume":"29","author":"Boles","year":"2007","journal-title":"Eur. Respir. J."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1465","DOI":"10.1001\/jama.2019.14901","article-title":"Effect of postextubation high-flow nasal oxygen with noninvasive ventilation vs high-flow nasal oxygen alone on reintubation among patients at high risk of extubation failure: A randomized clinical trial","volume":"322","author":"Thille","year":"2019","journal-title":"JAMA"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"772","DOI":"10.1164\/rccm.201602-0320OC","article-title":"Epidemiology of weaning outcome according to a new definition. The WIND Study","volume":"195","author":"Pham","year":"2017","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"R81","DOI":"10.1186\/cc11339","article-title":"Transthoracic echocardiography with Doppler tissue imaging predicts weaning failure from mechanical ventilation","volume":"16","author":"Moschietto","year":"2012","journal-title":"Crit. Care"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1512","DOI":"10.1097\/CCM.0b013e31819f13d0","article-title":"Echocardiographic diagnosis of pulmonary artery occlusion pressure elevation during weaning from mechanical ventilation","volume":"37","author":"Lamia","year":"2009","journal-title":"Crit. Care Med."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"R120","DOI":"10.1186\/cc9076","article-title":"Echocardiography: A help in the weaning process","volume":"14","author":"Caille","year":"2010","journal-title":"Crit. Care"},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Vignon, P. (2023). Cardiopulmonary interactions during ventilator weaning. Front. Physiol., 14.","DOI":"10.3389\/fphys.2023.1275100"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1186\/s13054-019-2601-8","article-title":"Myocardial ischemia during ventilator weaning: A prospective multicenter cohort study","volume":"23","author":"Bedet","year":"2019","journal-title":"Crit. Care"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"354","DOI":"10.21037\/atm.2018.05.46","article-title":"Cardiovascular failure and weaning","volume":"6","author":"Vignon","year":"2018","journal-title":"Ann. Transl. Med."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Keller, M., Magunia, H., Rosenberger, P., and Koeppen, M. (2023). Echocardiography as a tool to assess cardiac function in critical care\u2014A review. Diagnostics, 13.","DOI":"10.3390\/diagnostics13050839"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1441","DOI":"10.1016\/j.bja.2025.02.024","article-title":"Weaning failure from mechanical ventilation: A scoping review of the utility of ultrasonography in the weaning process","volume":"135","author":"Gallardo","year":"2025","journal-title":"Br. J. Anaesth."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1441","DOI":"10.1007\/s00134-017-4928-4","article-title":"Critical illness-associated diaphragm weakness","volume":"43","author":"Dres","year":"2017","journal-title":"Intensive Care Med."},{"key":"ref_13","first-page":"1503","article-title":"Diaphragm dysfunction on admission to the ICU: Prevalence, risk factors, and prognostic impact\u2014A prospective study","volume":"39","author":"Demoule","year":"2013","journal-title":"Intensive Care Med."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1164\/rccm.201703-0536OC","article-title":"Mechanical ventilation-induced diaphragm atrophy strongly impacts clinical outcomes","volume":"197","author":"Goligher","year":"2018","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1016\/j.jcrc.2016.03.007","article-title":"Diastolic dysfunction as a predictor of weaning failure: A systematic review and meta-analysis","volume":"34","author":"Nedel","year":"2016","journal-title":"J. Crit. Care"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1371","DOI":"10.1007\/s00134-020-06061-y","article-title":"Left ventricular overloading identified by critical care echocardiography is key in weaning-induced pulmonary edema","volume":"46","author":"Goudelin","year":"2020","journal-title":"Intensive Care Med."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1007\/s00134-019-05573-6","article-title":"Lung ultrasound allows the diagnosis of weaning-induced pulmonary oedema","volume":"45","author":"Guillot","year":"2019","journal-title":"Intensive Care Med."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1007\/s00134-019-05902-9","article-title":"Use of combined cardiac and lung ultrasound to predict weaning failure in elderly, high-risk cardiac patients: A pilot study","volume":"46","author":"Bouhemad","year":"2020","journal-title":"Intensive Care Med."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"642","DOI":"10.1007\/s00134-015-3687-3","article-title":"Measuring diaphragm thickness with ultrasound in mechanically ventilated patients: Feasibility, reproducibility and validity","volume":"41","author":"Goligher","year":"2015","journal-title":"Intensive Care Med."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1186\/s13054-023-04430-9","article-title":"Effectiveness of diaphragmatic ultrasound as a predictor of successful weaning from mechanical ventilation: A systematic review and meta-analysis","volume":"27","author":"Tibaduiza","year":"2023","journal-title":"Crit. Care"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"862","DOI":"10.1007\/s00134-015-4141-2","article-title":"Acute cor pulmonale during protective ventilation for acute respiratory distress syndrome: Prevalence, predictors, and outcomes","volume":"42","author":"Boissier","year":"2016","journal-title":"Intensive Care Med."},{"key":"ref_22","first-page":"528","article-title":"Heart\u2013lung interactions","volume":"13","author":"Pinsky","year":"2007","journal-title":"Curr. Opin. Crit. Care"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1186\/cc710","article-title":"Using heart\u2013lung interactions to assess fluid responsiveness during mechanical ventilation","volume":"4","author":"Michard","year":"2000","journal-title":"Crit. Care"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"739","DOI":"10.1007\/s00134-016-4326-3","article-title":"Experts\u2019 opinion on management of hemodynamics in ARDS patients: Focus on the effects of mechanical ventilation","volume":"42","author":"Matthay","year":"2016","journal-title":"Intensive Care Med."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1098","DOI":"10.1177\/08850666211003475","article-title":"Transthoracic right heart echocardiography for the intensivist","volume":"36","author":"Hockstein","year":"2021","journal-title":"J. Intensive Care Med."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1016\/j.echo.2016.01.011","article-title":"Recommendations for the evaluation of left ventricular diastolic function by echocardiography: An update from the ASE and EACVI","volume":"29","author":"Nagueh","year":"2016","journal-title":"J. Am. Soc. Echocardiogr."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"3200","DOI":"10.1053\/j.jvca.2024.08.014","article-title":"Correlation between Tissue Doppler Imaging method (E\/e\u2032) and invasive measurements of left ventricular filling pressures: A systematic review, meta-analysis, and meta-regression","volume":"38","author":"Orso","year":"2024","journal-title":"J. Cardiothorac. Vasc. Anesth."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1079","DOI":"10.1016\/j.chest.2020.03.071","article-title":"Longitudinal competence programs for basic point-of-care ultrasound in critical care: A systematic review","volume":"158","author":"Rajamani","year":"2020","journal-title":"Chest"},{"key":"ref_29","first-page":"1063","article-title":"Critical care ultrasonography in acute respiratory failure","volume":"149","author":"Vignon","year":"2016","journal-title":"Chest"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1378\/chest.07-2800","article-title":"Relevance of lung ultrasound in the diagnosis of acute respiratory failure: The BLUE protocol","volume":"134","author":"Lichtenstein","year":"2008","journal-title":"Chest"}],"container-title":["Diagnostics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4418\/16\/11\/1709\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T10:37:12Z","timestamp":1780396632000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4418\/16\/11\/1709"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,2]]},"references-count":30,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2026,6]]}},"alternative-id":["diagnostics16111709"],"URL":"https:\/\/doi.org\/10.3390\/diagnostics16111709","relation":{},"ISSN":["2075-4418"],"issn-type":[{"value":"2075-4418","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,2]]}}}