{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,12]],"date-time":"2026-08-12T08:36:00Z","timestamp":1786523760267,"version":"build-2736575974"},"reference-count":30,"publisher":"MDPI AG","issue":"16","license":[{"start":{"date-parts":[[2026,8,12]],"date-time":"2026-08-12T00:00:00Z","timestamp":1786492800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Diagnostics"],"abstract":"<jats:p>Background: The Six Sigma metric benchmarks analytical performance, but most reports assess one platform at one time point, merging trueness with imprecision. Using routine peer-group internal quality control (IQC), we profiled two clinical chemistry platforms over five months. Because peer-group IQC compares imprecision directly but positions trueness only against same-method peers, we characterise rather than rank cross-platform trueness. Methods: Bio-Rad Unity peer-group IQC (January\u2013May 2026) spanned two Siemens Dimension EXL analysers and two Roche cobas pro channels, two QC levels, and 30 analytes. TEa followed the CLIA 2024 Final Rule (25 analytes; provisional EFLM goals for five non-CLIA analytes). The Standard Deviation Index (SDI) referenced trueness to same-method peers, the CV ratio (CVR) imprecision, Sigma = (TEa \u2212 |bias|)\/CV. Analyte-level comparison used Wilcoxon signed-rank testing, a confirmatory mixed-effects model, and Westgard SQC mapping. Results: Across 25 CLIA-regulated analytes, median Sigma was 5.9 (IQR 4.8\u20138.2) for cobas pro versus 4.0 (2.3\u20136.1) for Dimension EXL: a Hodges\u2013Lehmann difference of 2.4 (95% CI 1.7\u20133.2; p &lt; 0.001), confirmed by CLIA-only (2.51) and mixed-effects (2.7) analyses. Both aligned with their peers (SDI near zero); the gap reflected imprecision (median CV 1.7% vs. 2.5%; CVR 0.83 vs. 1.02), stable across months and instruments. The ranking reversed for iron, GGT and amylase; sodium, chloride, urea and creatinine were TEa-limited. The SQC redesign averaged N = 6 versus N = 3 controls\/run (Dimension vs. cobas pro). Conclusions: A precision-driven difference separated the platforms as implemented here. Cross-platform trueness could not be ranked, yet decomposing Sigma localised precision limits, isolated calibration outliers, and produced analyte-specific SQC strategies needing prospective validation.<\/jats:p>","DOI":"10.3390\/diagnostics16162537","type":"journal-article","created":{"date-parts":[[2026,8,12]],"date-time":"2026-08-12T07:57:26Z","timestamp":1786521446000},"page":"2537","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Longitudinal Sigma-Metric Profiling of Two Clinical Chemistry Platforms Using Peer-Group Internal Quality Control"],"prefix":"10.3390","volume":"16","author":[{"given":"Indah","family":"Meyliza","sequence":"first","affiliation":[{"name":"Clinical Pathology Subspecialization Program, Faculty of Medicine, Universitas Airlangga, Surabaya 60115, Indonesia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9055-0177","authenticated-orcid":false,"given":"Aryati","family":"Aryati","sequence":"additional","affiliation":[{"name":"Department of Clinical Pathology, Faculty of Medicine, Universitas Airlangga, Surabaya 60115, Indonesia"},{"name":"Dr. Soetomo General Academic Hospital, Surabaya 60286, Indonesia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6570-1877","authenticated-orcid":false,"given":"Ferdy Royland","family":"Marpaung","sequence":"additional","affiliation":[{"name":"Department of Clinical Pathology, Faculty of Medicine, Universitas Airlangga, Surabaya 60115, Indonesia"},{"name":"Dr. Soetomo General Academic Hospital, Surabaya 60286, Indonesia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,8,12]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"120240","DOI":"10.1016\/j.cca.2025.120240","article-title":"Ensuring internal quality control practices in medical laboratories: IFCC recommendations for practical applications based on ISO 15189:2022","volume":"571","author":"Giannoli","year":"2025","journal-title":"Clin. Chim. Acta"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/j.cca.2022.05.012","article-title":"Sigma metrics in laboratory medicine: A call for harmonization","volume":"532","author":"Wauthier","year":"2022","journal-title":"Clin. Chim. Acta"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Gruber, L., Hausch, A., and Mueller, T. (2024). Internal quality controls in the medical laboratory: A narrative review of the basic principles of an appropriate quality control plan. Diagnostics, 14.","DOI":"10.3390\/diagnostics14192223"},{"key":"ref_4","unstructured":"Westgard, J.O., and Westgard, S.A. (2006). Six Sigma Quality Design and Control: Desirable Precision and Requisite QC, Westgard QC. [2nd ed.]."},{"key":"ref_5","unstructured":"Clinical and Laboratory Standards Institute (2016). Statistical Quality Control for Quantitative Measurement Procedures: Principles and Definitions. CLSI Guideline C24, CLSI. [4th ed.]."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1177\/00045632251330163","article-title":"Sigma metrics for assessing the analytical performance of 14 biochemical analytes in Mansoura University children\u2019s hospital laboratories using CLIA limits 1988 and 2024","volume":"62","author":"Karam","year":"2025","journal-title":"Ann. Clin. Biochem."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1264","DOI":"10.1093\/jalm\/jfab028","article-title":"A survey of Sigma metrics across three academic medical centers","volume":"6","author":"Feldhammer","year":"2021","journal-title":"J. Appl. Lab. Med."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.6026\/973206300191043","article-title":"Analysis of biochemical analytes using six sigma metrics with two analyzers at an Indian lab setting","volume":"19","author":"Gadde","year":"2023","journal-title":"Bioinformation"},{"key":"ref_9","first-page":"e51386","article-title":"The evaluation of the quality performance of biochemical analytes in clinical biochemistry laboratory using Six Sigma matrices","volume":"15","author":"Panda","year":"2023","journal-title":"Cureus"},{"key":"ref_10","first-page":"282","article-title":"The analytical performance evaluation of routine clinical chemistry parameters by Six Sigma approach: An effective tool for laboratory quality management","volume":"30","author":"Rasheed","year":"2024","journal-title":"Ann. King Edw. Med. Univ."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"119971","DOI":"10.1016\/j.cca.2024.119971","article-title":"Beyond the basics: Sigma scores in laboratory medicine with variable total allowable errors (TEa)","volume":"565","author":"Yadav","year":"2025","journal-title":"Clin. Chim. Acta"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"020502","DOI":"10.11613\/BM.2018.020502","article-title":"Analytical Sigma metrics: A review of Six Sigma implementation tools for medical laboratories","volume":"28","author":"Westgard","year":"2018","journal-title":"Biochem. Medica"},{"key":"ref_13","first-page":"e74693","article-title":"Achieving high standards in clinical biochemistry: Integrating Six Sigma, Quality Goal Index (QGI), and Operating Specifications (OPSpecs) for targeted quality enhancement","volume":"16","author":"Panchal","year":"2024","journal-title":"Cureus"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"27","DOI":"10.33086\/ijmlst.v6i1.4930","article-title":"Comparison of the sigma metrics using the total error allowable algorithm with variation of bias source","volume":"6","author":"Rinaldi","year":"2024","journal-title":"Indones. J. Med. Lab. Sci. Technol."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Bhatnagar, S., Westgard, S., Dung, N.T.T., Que, T.N., Khanh, B.Q., and Thanh, N.H. (2024). Applying sigma metrics to assess quality control processes in the transfusion transmissible infection screening laboratory of a blood center. PLoS ONE, 19.","DOI":"10.1371\/journal.pone.0312422"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1007\/s12291-021-00994-x","article-title":"Evaluation of sigma metrics and Westgard rule selection and implementation of internal quality control in clinical chemistry reference laboratory, Ethiopian Public Health Institute","volume":"37","author":"Geto","year":"2022","journal-title":"Indian J. Clin. Biochem."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"2435","DOI":"10.1515\/cclm-2024-0859","article-title":"External quality assessment performance in ten countries: An IFCC global laboratory quality project","volume":"62","author":"Bais","year":"2024","journal-title":"Clin. Chem. Lab. Med."},{"key":"ref_18","unstructured":"Centers for Medicare & Medicaid Services (2022). Clinical Laboratory Improvement Amendments of 1988 (CLIA) proficiency testing regulations related to analytes and acceptable performance; final rule (CMS-3355-F). Fed. Regist., 87, 41194\u201341242."},{"key":"ref_19","unstructured":"Aarsand, A.K., Webster, C., Fernandez-Calle, P., Jonker, N., Diaz-Garzon, J., Coskun, A., Sufrate-Vergara, B., Moreno-Parro, I., Galior, K., and Topcu, D. (2026, June 21). The EFLM Biological Variation Database. European Federation of Clinical Chemistry and Laboratory Medicine. Available online: https:\/\/biologicalvariation.eu."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1483","DOI":"10.1515\/cclm-2024-0108","article-title":"Analytical performance specifications based on biological variation data\u2014Considerations, strengths and limitations","volume":"62","author":"Sandberg","year":"2024","journal-title":"Clin. Chem. Lab. Med."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1512","DOI":"10.1515\/cclm-2024-0102","article-title":"Using analytical performance specifications in a medical laboratory","volume":"62","author":"Jones","year":"2024","journal-title":"Clin. Chem. Lab. Med."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1515\/cclm-2024-0489","article-title":"A standard to report biological variation data studies based on an expert opinion","volume":"63","author":"Bartlett","year":"2025","journal-title":"Clin. Chem. Lab. Med."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"973","DOI":"10.1515\/cclm-2013-1090","article-title":"Sigma metrics used to assess analytical quality of clinical chemistry assays: Importance of the allowable total error (TEa) target","volume":"52","author":"Hens","year":"2014","journal-title":"Clin. Chem. Lab. Med."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"252","DOI":"10.55691\/2278-344X.1035","article-title":"Sigma-metric analysis to evaluate quality management of analytical processes using RCA and QGI in a clinical biochemistry laboratory, South India","volume":"11","author":"Nilakantam","year":"2023","journal-title":"Int. J. Health Allied Sci."},{"key":"ref_25","first-page":"030704","article-title":"Refining quality control strategies in highly automated laboratories: Experience in the integration of multistage statistical designs and risk management","volume":"35","author":"Canyelles","year":"2025","journal-title":"Biochem. Medica"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"194","DOI":"10.4103\/JLP.JLP_102_17","article-title":"Sigma metrics as a tool for evaluating the performance of internal quality control in a clinical chemistry laboratory","volume":"10","author":"Kumar","year":"2018","journal-title":"J. Lab. Physicians"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1016\/j.clinbiochem.2023.02.005","article-title":"Application of a six sigma model to evaluate the analytical performance of cerebrospinal fluid biochemical analytes and the design of quality control strategies for these assays: A single-centre study","volume":"114","author":"Liu","year":"2023","journal-title":"Clin. Biochem."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"774","DOI":"10.4103\/jfmpc.jfmpc_1768_25","article-title":"A comparative study of sigma metrics and statistical quality control rules in clinical biochemistry laboratories using a cobas pure analyzer","volume":"15","author":"Ahmad","year":"2026","journal-title":"J. Fam. Med. Prim. Care"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1524","DOI":"10.18203\/2349-3933.ijam20194155","article-title":"Application of Six Sigma metrics and method decision charts in improvising clinical chemistry laboratory performance enhancement","volume":"6","author":"Aggarwal","year":"2019","journal-title":"Int. J. Adv. Med."},{"key":"ref_30","unstructured":"(2022). Medical Laboratories\u2014Requirements for Quality and Competence (Standard No. ISO 15189:2022)."}],"container-title":["Diagnostics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4418\/16\/16\/2537\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,12]],"date-time":"2026-08-12T08:11:54Z","timestamp":1786522314000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4418\/16\/16\/2537"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,12]]},"references-count":30,"journal-issue":{"issue":"16","published-online":{"date-parts":[[2026,8]]}},"alternative-id":["diagnostics16162537"],"URL":"https:\/\/doi.org\/10.3390\/diagnostics16162537","relation":{},"ISSN":["2075-4418"],"issn-type":[{"value":"2075-4418","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,12]]}}}