{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T14:31:17Z","timestamp":1787581877468,"version":"build-2736575974"},"reference-count":33,"publisher":"MDPI AG","issue":"16","license":[{"start":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T00:00:00Z","timestamp":1787011200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Diagnostics"],"abstract":"<jats:p>Background\/Objectives: Lung cancer remains one of the leading causes of cancer-related mortality worldwide. Conventional computed tomography (CT) is the preferred imaging modality for evaluating pulmonary nodules because of its high spatial resolution; however, it primarily provides morphological information, including lesion size, shape, and density. Dual-energy CT (DECT), a more recent imaging technique, uses two different energy levels to enable material decomposition and quantitative parameter assessment. These parameters may provide additional information regarding tumor perfusion, vascularization, and tissue composition. This rapid review aimed to evaluate the current evidence regarding the clinical utility of DECT in the detection, characterization, and staging of lung tumors. Methods: This rapid review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. A literature search was performed in the PubMed and Cochrane Library databases for studies published between 2005 and 2026. Studies were included if they evaluated the detection, characterization, or staging of lung tumors using quantitative DECT parameters. Case reports, editorials, duplicate studies, and studies without quantitative DECT data were excluded. Descriptive data analysis was performed using Microsoft Excel. Results: A total of 24 studies were included, comprising 18 retrospective (75%) and 6 prospective studies (25%). Only one study evaluated the role of DECT in lung tumor detection, demonstrating improved detection of mixed ground-glass nodules and invasive adenocarcinoma. Significant correlations were found between iodine uptake and tumor perfusion, highlighting the potential of DECT to improve differentiation between benign and malignant lesions. Several studies also demonstrated associations between DECT parameters and tumor biomarkers, including Ki-67 Proliferation Index (Ki-67) expression, Epidermal Growth Factor Receptor (EGFR) mutation status, Programmed Death-Ligand 1 (PD-L1) expression, and treatment response in non-small cell lung cancer. In addition, DECT provided complementary metabolic information regarding tumor malignancy and showed correlations between iodine uptake and fluorodeoxyglucose (FDG) parameters. Associations between iodine volume and tumor differentiation grade were also reported. One study demonstrated the potential role of DECT in tumor staging by predicting mediastinal lymph node metastasis. Across all included studies, iodine-based parameters (50%), radiomics and material decomposition parameters (16.67% each), and spectral attenuation parameters (12.50%) were the most frequently investigated DECT metrics. Conclusions: DECT appears to be a promising complementary imaging technique that provides quantitative perfusion-related and compositional surrogate information beyond the morphological assessment offered by conventional CT. However, the current evidence remains heterogeneous and is largely based on retrospective studies with relatively small patient cohorts. Larger prospective studies with standardized imaging protocols are necessary to further establish the clinical utility of DECT in lung tumors.<\/jats:p>","DOI":"10.3390\/diagnostics16162611","type":"journal-article","created":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T08:08:41Z","timestamp":1787040521000},"page":"2611","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Clinical Utility of Dual-Energy CT for Detection, Characterization, and Staging of Lung Tumors: A Rapid Review"],"prefix":"10.3390","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0009-0001-5247-2814","authenticated-orcid":false,"given":"Hassibullah","family":"Sidiqy","sequence":"first","affiliation":[{"name":"\u201cGeorge Emil Palade\u201d University of Medicine, Pharmacy, Science and Technology of T\u00e2rgu Mure\u0219, 540142\u00a0T\u00e2rgu Mure\u0219, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Khalida","family":"Sidiqy","sequence":"additional","affiliation":[{"name":"Doctari GmbH, 10247 Berlin, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claudia Raluca","family":"Mariean","sequence":"additional","affiliation":[{"name":"Pathophysiology Department, \u201cGeorge Emil Palade\u201d University of Medicine, Pharmacy, Science and Technology of T\u00e2rgu Mure\u0219, 540142 T\u00e2rgu Mure\u0219, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5324-9780","authenticated-orcid":false,"given":"Marian","family":"Pop","sequence":"additional","affiliation":[{"name":"Department ME2, \u201cGeorge Emil Palade\u201d University of Medicine, Pharmacy, Science and Technology, 540142 T\u00e2rgu Mure\u0219, Romania"},{"name":"Department of Radiology, Mure\u0219 County Clinical Emergency Hospital, 540142 T\u00e2rgu Mure\u0219, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,8,18]]},"reference":[{"key":"ref_1","first-page":"229","article-title":"Global cancer statistics 2022: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries","volume":"74","author":"Bray","year":"2024","journal-title":"CA Cancer J. Clin."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"5901","DOI":"10.1007\/s00432-022-04543-8","article-title":"Dual-layer spectral detector CT (SDCT) can improve the detection of mixed ground-glass lung nodules","volume":"149","author":"Zhang","year":"2023","journal-title":"J. Cancer Res. Clin. Oncol."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"He, C., Liu, J., Li, Y., Lin, L., Qing, H., Guo, L., Hu, S., and Zhou, P. (2022). Quantitative parameters of enhanced dual-energy computed tomography for differentiating lung cancers from benign lesions in solid pulmonary nodules. Front. Oncol., 12.","DOI":"10.3389\/fonc.2022.1027985"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"95","DOI":"10.21037\/atm.2018.01.25","article-title":"The role of positron emission tomography in the diagnosis, staging and response assessment of non-small cell lung cancer","volume":"6","author":"Volpi","year":"2018","journal-title":"Ann. Transl. Med."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"e70020","DOI":"10.1002\/acm2.70020","article-title":"Review of the application of dual-energy CT combined with radiomics in the diagnosis and analysis of lung cancer","volume":"26","author":"Zhang","year":"2025","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"S40","DOI":"10.2214\/AJR.12.9112","article-title":"Dual-energy CT of the lung","volume":"199","author":"Lu","year":"2012","journal-title":"AJR Am. J. Roentgenol."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Perrella, A., Bagnacci, G., Di Meglio, N., Di Martino, V., and Mazzei, M.A. (2023). Thoracic diseases: Technique and applications of dual-energy CT. Diagnostics, 13.","DOI":"10.3390\/diagnostics13142440"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"145","DOI":"10.21037\/jtd-2025-1-2449","article-title":"Application of dual-energy computed tomography combined with radiomics in the clinical diagnosis of lung cancer: A systematic review and meta-analysis","volume":"18","author":"Zhang","year":"2026","journal-title":"J. Thorac. Dis."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Luna, A., Vilanova, J.C., Hygino da Cruz, L.C., and Rossi, S.E. (2014). Dual-energy and spectral energy computed tomography: Oncological body applications in clinical use. Functional Imaging in Oncology: Biophysical Basis and Technical Approaches\u2014Volume 1, Springer.","DOI":"10.1007\/978-3-642-40412-2"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1148\/radiol.2492071956","article-title":"Clinical utility of dual-energy CT in the evaluation of solitary pulmonary nodules: Initial experience","volume":"249","author":"Chae","year":"2008","journal-title":"Radiology"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"702","DOI":"10.3348\/kjr.2012.13.6.702","article-title":"Dual-energy CT in patients treated with anti-angiogenic agents for non-small cell lung cancer: New method of monitoring tumor response?","volume":"13","author":"Kim","year":"2012","journal-title":"Korean J. Radiol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"20150224","DOI":"10.1259\/bjr.20150224","article-title":"Evaluation of lung cancer by enhanced dual-energy CT: Association between three-dimensional iodine concentration and tumour differentiation","volume":"88","author":"Iwano","year":"2015","journal-title":"Br. J. Radiol."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"e7479","DOI":"10.1097\/MD.0000000000007479","article-title":"Correlation of iodine uptake and perfusion parameters between dual-energy CT imaging and first-pass dual-input perfusion CT in lung cancer","volume":"96","author":"Chen","year":"2017","journal-title":"Medicine"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"3459","DOI":"10.21873\/anticanres.14332","article-title":"Correlation of iodine quantification and FDG uptake in early therapy response assessment of non-small cell lung cancer: Possible benefit of dual-energy CT scan as an integral part of PET\/CT examination","volume":"40","author":"Baxa","year":"2020","journal-title":"Anticancer Res."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Zegad\u0142o, A., \u017babicka, M., Kania-Pud\u0142o, M., Maliborski, A., R\u00f3\u017cyk, A., and So\u015bnicki, W. (2020). Assessment of solitary pulmonary nodules based on virtual monochrome images and iodine-dependent images using a single-source dual-energy CT with fast kVp switching. J. Clin. Med., 9.","DOI":"10.3390\/jcm9082514"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1002","DOI":"10.1007\/s00330-020-07195-9","article-title":"Improved differentiation between primary lung cancer and pulmonary metastasis by combining dual-energy CT-derived biomarkers with conventional CT attenuation","volume":"31","author":"Deniffel","year":"2021","journal-title":"Eur. Radiol."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"275","DOI":"10.5152\/dir.2021.20016","article-title":"A comparison study of dual-energy spectral CT and 18F-FDG PET\/CT in primary tumors and lymph nodes of lung cancer","volume":"27","author":"Kupik","year":"2021","journal-title":"Diagn. Interv. Radiol."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Li, Q., Fan, X., Luo, T.Y., Lv, F.J., and Huang, X.T. (2021). Differentiating malignant and benign necrotic lung lesions using kVp-switching dual-energy spectral computed tomography. BMC Med. Imaging, 21.","DOI":"10.1186\/s12880-021-00611-6"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1770","DOI":"10.3390\/tomography8040149","article-title":"Assessment of correlation between dual-energy CT (DE-CT)-derived iodine concentration and local flourodeoxyglucose (FDG) uptake in patients with primary non-small-cell lung cancer","volume":"8","author":"Andersen","year":"2022","journal-title":"Tomography"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"e29444","DOI":"10.1097\/MD.0000000000029444","article-title":"Application of dual-energy computed tomography in preoperative evaluation of Ki-67 expression levels in solid non-small cell lung cancer","volume":"101","author":"Tian","year":"2022","journal-title":"Medicine"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"15425","DOI":"10.1007\/s00432-023-05311-y","article-title":"Preoperative predicting invasiveness of lung adenocarcinoma manifesting as ground-glass nodules based on multimodal images of dual-layer spectral detector CT radiomics models","volume":"149","author":"Chang","year":"2023","journal-title":"J. Cancer Res. Clin. Oncol."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"8121","DOI":"10.21037\/qims-23-736","article-title":"Extracellular volume fraction as a potential predictor to differentiate lung cancer from benign lung lesions with dual-layer detector spectral CT","volume":"13","author":"Jiang","year":"2023","journal-title":"Quant. Imaging Med. Surg."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Zheng, Y., Han, X., Jia, X., Ding, C., Zhang, K., Li, H., Cao, X., Zhang, X., Zhang, X., and Shi, H. (2023). Dual-energy CT-based radiomics for predicting invasiveness of lung adenocarcinoma appearing as ground-glass nodules. Front. Oncol., 13.","DOI":"10.3389\/fonc.2023.1208758"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"e40014","DOI":"10.1097\/MD.0000000000040014","article-title":"Assessment of solitary pulmonary nodules using dual-layer spectral detector computed tomography","volume":"103","author":"Ko","year":"2024","journal-title":"Medicine"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"e24372","DOI":"10.1016\/j.heliyon.2024.e24372","article-title":"Dual-energy CT-based radiomics in predicting EGFR mutation status non-invasively in lung adenocarcinoma","volume":"10","author":"Ma","year":"2024","journal-title":"Heliyon"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"255","DOI":"10.3390\/tomography10020020","article-title":"Differentiation of hamartomas and malignant lung tumors in single-phased dual-energy computed tomography","volume":"10","author":"Winkelmann","year":"2024","journal-title":"Tomography"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"749","DOI":"10.21037\/qims-23-447","article-title":"Value of dual-layer spectral detector CT in predicting lymph node metastasis of non-small cell lung cancer","volume":"14","author":"Xie","year":"2024","journal-title":"Quant. Imaging Med. Surg."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"18310","DOI":"10.1038\/s41598-024-69470-9","article-title":"Three-dimensional iodine mapping quantified by dual-energy CT for predicting programmed death-ligand 1 expression in invasive pulmonary adenocarcinoma","volume":"14","author":"Yamagata","year":"2024","journal-title":"Sci. Rep."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"e14616","DOI":"10.1002\/acm2.14616","article-title":"Radiomics based on dual-layer spectral detector CT for predicting EGFR mutation status in non-small cell lung cancer","volume":"26","author":"Jin","year":"2025","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"320","DOI":"10.4314\/ahs.v25i2.38","article-title":"Multiparametric dual-energy computed tomography in the diagnosis of lung adenocarcinoma patients and its correlation with tissue Ki-67 expression level","volume":"25","author":"Su","year":"2025","journal-title":"Afr. Health Sci."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"4858","DOI":"10.21037\/jtd-2025-516","article-title":"The value of dual-energy spectral CT in differentiating the pathological grades of T1-size lung adenocarcinoma","volume":"17","author":"Yu","year":"2025","journal-title":"J. Thorac. Dis."},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Mariean, C.R., Tiuc\u0103, O.M., Al-Akel, C.F., and Cotoi, O.S. (2025). HISLIS: Histology, sarcopenia, and lung inflammation score\u2014A new perspective for lung cancer patients?. Life, 15.","DOI":"10.3390\/life15060963"},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Pop, M., and M\u0103ru\u015fteri, M. (2023). Fat Hounsfield unit reference interval derived through an indirect method. Diagnostics, 13.","DOI":"10.3390\/diagnostics13111913"}],"container-title":["Diagnostics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4418\/16\/16\/2611\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T13:35:13Z","timestamp":1787578513000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4418\/16\/16\/2611"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,18]]},"references-count":33,"journal-issue":{"issue":"16","published-online":{"date-parts":[[2026,8]]}},"alternative-id":["diagnostics16162611"],"URL":"https:\/\/doi.org\/10.3390\/diagnostics16162611","relation":{},"ISSN":["2075-4418"],"issn-type":[{"value":"2075-4418","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,18]]}}}