{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T13:32:02Z","timestamp":1787146322388,"version":"build-2736575974"},"reference-count":17,"publisher":"MDPI AG","issue":"16","license":[{"start":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T00:00:00Z","timestamp":1787097600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Diagnostics"],"abstract":"<jats:p>Background\/Objectives: Modern automated hematology analyzers combine quantitative cell counting with proprietary algorithms for automated morphological interpretation. While analytical validation traditionally focuses on measurement agreement, less attention has been paid to the evaluation of algorithm-assisted morphological interpretation. This study compared the analytical performance and automated morphological flagging of the Sysmex XN-9100 and Mindray BC-7800\/BC-7900 platforms under routine laboratory conditions. Methods: A total of 183 peripheral blood samples collected between October 2025 and February 2026 were analyzed in parallel using both platforms. The study population included healthy individuals and patients with hematological and non-hematological disorders. Analytical agreement for complete blood count (CBC) and leukocyte differential parameters was assessed using Passing\u2013Bablok regression and Bland\u2013Altman analyses. Automated morphological flagging was evaluated in 157 samples using expert optical microscopy as the reference standard. McNemar\u2019s test, Cohen\u2019s kappa coefficient, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy were calculated. Results: Excellent agreement was observed for the principal CBC parameters, including white blood cell count, red blood cell count, hemoglobin, hematocrit, mean corpuscular volume, and platelet count (correlation coefficients: 0.981\u20131.000), with minimal proportional bias. Greater variability was found for monocytes, eosinophils, and basophils, particularly at low cell concentrations. Although analytical performance was highly comparable, the two platforms showed different morphological flagging profiles. Both analyzers achieved high negative predictive values (&gt;90%), while differences in sensitivity and specificity across individual flag categories reflected distinct algorithm-assisted classification strategies. Agreement with expert microscopy ranged from fair to moderate for most pathological flags. Conclusions: The Mindray BC-7800\/BC-7900 and Sysmex XN-9100 demonstrated excellent analytical agreement for routine CBC testing. However, comparable analytical performance did not necessarily correspond to identical automated morphological interpretation. These results indicate that evaluation of modern hematology analyzers should include both analytical performance and agreement between automated flags and expert microscopy.<\/jats:p>","DOI":"10.3390\/diagnostics16162642","type":"journal-article","created":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T13:14:01Z","timestamp":1787145241000},"page":"2642","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Beyond Analytical Agreement: Integrating Analytical Performance and Algorithm-Assisted Morphological Interpretation in a Comparative Evaluation of the Mindray BC-7800\/BC-7900 and Sysmex XN-9100 Hematology Platforms"],"prefix":"10.3390","volume":"16","author":[{"given":"Sara","family":"Ciullini Mannurita","sequence":"first","affiliation":[{"name":"General Laboratory, Azienda Ospedaliero-Universitaria Careggi, 50134 Florence, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-8960-1633","authenticated-orcid":false,"given":"Domenico","family":"Romeo","sequence":"additional","affiliation":[{"name":"General Laboratory, Azienda Ospedaliero-Universitaria Careggi, 50134 Florence, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9136-822X","authenticated-orcid":false,"given":"Alessandro","family":"Bonari","sequence":"additional","affiliation":[{"name":"General Laboratory, Azienda Ospedaliero-Universitaria Careggi, 50134 Florence, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edda","family":"Russo","sequence":"additional","affiliation":[{"name":"Clinical Pathology Laboratory Unit, S. Giuseppe Hospital, Azienda USL Toscana Centro, 50053 Empoli, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pamela","family":"Nardiello","sequence":"additional","affiliation":[{"name":"General Laboratory, Azienda Ospedaliero-Universitaria Careggi, 50134 Florence, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2711-0088","authenticated-orcid":false,"given":"Valentina","family":"Becherucci","sequence":"additional","affiliation":[{"name":"Clinical Pathology Laboratory, Santa Maria Annunziata Hospital, 50134 Florence, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniela","family":"Vitali","sequence":"additional","affiliation":[{"name":"General Laboratory, Azienda Ospedaliero-Universitaria Careggi, 50134 Florence, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alessandra","family":"Fanelli","sequence":"additional","affiliation":[{"name":"General Laboratory, Azienda Ospedaliero-Universitaria Careggi, 50134 Florence, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesca","family":"Romano","sequence":"additional","affiliation":[{"name":"General Laboratory, Azienda Ospedaliero-Universitaria Careggi, 50134 Florence, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,8,19]]},"reference":[{"key":"ref_1","first-page":"S11","article-title":"Advances of the past decade in automated hematology","volume":"98","author":"Gulati","year":"1992","journal-title":"Am. J. Clin. Pathol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.cll.2014.11.003","article-title":"Development, history, and future of automated cell counters","volume":"35","author":"Green","year":"2015","journal-title":"Clin. Lab. Med."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/j.cll.2014.10.005","article-title":"Digital image analysis of blood cells","volume":"35","year":"2015","journal-title":"Clin. Lab. Med."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"15","DOI":"10.4103\/JLP.JLP_124_17","article-title":"Automated hematology analyzers: Recent trends and applications","volume":"10","author":"Chhabra","year":"2018","journal-title":"J. Lab. Physicians"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1024","DOI":"10.1136\/jclinpath-2012-200930","article-title":"Performance evaluation of the Sysmex haematology XN modular system","volume":"65","author":"Briggs","year":"2012","journal-title":"J. Clin. Pathol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1136\/jclinpath-2014-202640","article-title":"The value of the white precursor cell channel (WPC) on the Sysmex XN-1000 analyser in a specialist paediatric hospital","volume":"68","author":"Jones","year":"2015","journal-title":"J. Clin. Pathol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"869","DOI":"10.1111\/ijlh.12421","article-title":"Comparison of white blood cell counts by WNR, WDF, and WPC channels in Sysmex XN hematology analyzer","volume":"37","author":"Kim","year":"2015","journal-title":"Int. J. Lab. Hematol."},{"key":"ref_8","first-page":"1503","article-title":"Performance of the XN-2000 WPC channel-flagging to differentiate reactive and neoplastic leukocytosis","volume":"54","author":"Kohlschein","year":"2016","journal-title":"Clin. Chem. Lab. Med."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"734","DOI":"10.1111\/ijlh.13274","article-title":"Performance of the Sysmex White Precursor Channel to discover circulating leukemic blast cells","volume":"42","author":"Sejrup","year":"2020","journal-title":"Int. J. Lab. Hematol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1111\/ijlh.12254","article-title":"Performance evaluation of the new hematology analyzer Sysmex XN-series","volume":"37","author":"Seo","year":"2015","journal-title":"Int. J. Lab. Hematol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1093\/ajcp\/97.3.345","article-title":"Evaluation of four automated hematology analyzers. A comparative study of differential counts (imprecision and inaccuracy)","volume":"97","author":"Buttarello","year":"1992","journal-title":"Am. J. Clin. Pathol."},{"key":"ref_12","unstructured":"Clinical and Laboratory Standards Institute (CLSI) (2007). Reference Leukocyte (WBC) Differential Count (Proportional) and Evaluation of Instrumental Methods, Clinical and Laboratory Standards Institute. Approved Standard\u2014Second Edition. CLSI document H20-A2."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"2185","DOI":"10.7754\/Clin.Lab.2025.250124","article-title":"Performance Validation and Evaluation of the Mindray BC-7900 Automated Hematology Analyzer","volume":"71","author":"Jin","year":"2025","journal-title":"Clin. Lab."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1111\/j.1365-2141.2010.08366.x","article-title":"A European consensus report on blood cell identification: Terminology utilized and morphological diagnosis concordance among 28 experts from 17 countries within the European LeukemiaNet network WP10, on behalf of the ELN Morphology Faculty","volume":"151","author":"Zini","year":"2010","journal-title":"Br. J. Haematol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1532\/LH96.05019","article-title":"The International Consensus Group for Hematology Review: Suggested criteria for action following automated CBC and WBC differential analysis","volume":"11","author":"Barnes","year":"2005","journal-title":"Lab. Hematol."},{"key":"ref_16","unstructured":"Python Software Foundation (2025, December 10). Python: A Programming Language. Available online: https:\/\/www.python.org."},{"key":"ref_17","unstructured":"Microsoft Corporation (2025, December 10). Visual Studio Code. Available online: https:\/\/code.visualstudio.com\/."}],"container-title":["Diagnostics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4418\/16\/16\/2642\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T13:23:04Z","timestamp":1787145784000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4418\/16\/16\/2642"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,19]]},"references-count":17,"journal-issue":{"issue":"16","published-online":{"date-parts":[[2026,8]]}},"alternative-id":["diagnostics16162642"],"URL":"https:\/\/doi.org\/10.3390\/diagnostics16162642","relation":{},"ISSN":["2075-4418"],"issn-type":[{"value":"2075-4418","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,19]]}}}