{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T05:05:53Z","timestamp":1789103153607,"version":"build-2803163510"},"reference-count":16,"publisher":"MDPI AG","issue":"18","license":[{"start":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T00:00:00Z","timestamp":1788912000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Diagnostics"],"abstract":"<jats:p>Objectives: We aimed to determine quantitative photon-counting CT (PCCT)-derived iodine map (IM) attenuation associated with visual detectability of parenchymal hyperattenuation on conventional brain window (BW) images after mechanical thrombectomy (MT) and to assess corresponding relative BW attenuation changes. Methods: In this retrospective single-center study, 12 patients with anterior circulation large vessel occlusion underwent MT followed by post-interventional PCCT. BW, IM, and virtual non-contrast reconstructions were generated. Follow-up non-contrast CT served as reference for final infarction extent. Of 54 ASPECTS regions with final infarction, 40 showed IM hyperattenuation and were included in the detectability analysis. Two blinded readers assessed visual detectability. IM attenuation and relative BW attenuation increase (%\u0394HU) were evaluated using ROC analysis with clustered bootstrap resampling. Thresholds were determined using the Youden index. Results: Across all 54 regions with final infarction, median IM attenuation was significantly higher in infarcted than contralateral regions (6.39 vs. 2.18 HU, p &lt; 0.001), while absolute BW attenuation did not differ significantly. Among the 40 regions with IM hyperattenuation, 15 were visually detectable on BW images. ROC analysis showed excellent performance for IM (AUC = 0.997) and %\u0394HU (AUC = 0.984). The optimal IM threshold in the original cohort was 8.33 HU (sensitivity 100%, specificity 96.0%), and the optimal %\u0394HU threshold was 3.06% (sensitivity 100%, specificity 92.0%). Bootstrap-derived median thresholds were 11.69 HU (95% interval 8.33\u201312.67) for IM and 3.06% (3.06\u201320.16%) for %\u0394HU. Inter-reader agreement was excellent (\u03ba = 0.81\u20130.86). Conclusions: PCCT-derived iodine quantification enables objective assessment of visual detectability of post-interventional parenchymal hyperattenuation. In this cohort, an internally derived IM cutoff of 8.33 HU was associated with BW visibility. These preliminary findings require validation in larger, independent multicenter cohorts.<\/jats:p>","DOI":"10.3390\/diagnostics16182915","type":"journal-article","created":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T14:02:48Z","timestamp":1788962568000},"page":"2915","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["From Iodine Maps to Brain Window Images: Quantitative Visibility Thresholds of Iodine Staining Using Photon-Counting CT\u2014A Retrospective Observational Study"],"prefix":"10.3390","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1148-8799","authenticated-orcid":false,"given":"Marie-Christine","family":"Pali","sequence":"first","affiliation":[{"name":"Department of Radiology, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria"},{"name":"Neuroimaging Research Core Facility, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5790-2724","authenticated-orcid":false,"given":"Stephanie","family":"Mangesius","sequence":"additional","affiliation":[{"name":"Department of Radiology, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria"},{"name":"Neuroimaging Research Core Facility, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-4845-8315","authenticated-orcid":false,"given":"Constantin Emanuel","family":"Eisenschink","sequence":"additional","affiliation":[{"name":"Department of Radiology, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria"},{"name":"Neuroimaging Research Core Facility, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-2228-0398","authenticated-orcid":false,"given":"Philipp","family":"Deisl","sequence":"additional","affiliation":[{"name":"Department of Radiology, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria"},{"name":"Neuroimaging Research Core Facility, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3263-5724","authenticated-orcid":false,"given":"Lukas","family":"Neumann","sequence":"additional","affiliation":[{"name":"Department of Basic Sciences in Engineering Sciences, University of Innsbruck, 6020 Innsbruck, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5576-6562","authenticated-orcid":false,"given":"Michael","family":"Knoflach","sequence":"additional","affiliation":[{"name":"Department of Neurology, Medical University of Innsbruck, 6020 Innsbruck, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raimund","family":"Pechlaner","sequence":"additional","affiliation":[{"name":"Department of Neurology, Medical University of Innsbruck, 6020 Innsbruck, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bernhard","family":"Glodny","sequence":"additional","affiliation":[{"name":"Department of Radiology, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1716-1057","authenticated-orcid":false,"given":"Lukas","family":"Lenhart","sequence":"additional","affiliation":[{"name":"Department of Radiology, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria"},{"name":"Neuroimaging Research Core Facility, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6859-8377","authenticated-orcid":false,"given":"Elke Ruth","family":"Gizewski","sequence":"additional","affiliation":[{"name":"Department of Radiology, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria"},{"name":"Neuroimaging Research Core Facility, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2304-3946","authenticated-orcid":false,"given":"Astrid Ellen","family":"Grams","sequence":"additional","affiliation":[{"name":"Department of Radiology, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria"},{"name":"Neuroimaging Research Core Facility, Medical University of Innsbruck, Anichstrasse 35, 6020 Innsbruck, Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,9,9]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"e8","DOI":"10.1136\/neurintsurg-2018-014569","article-title":"European Stroke Organisation (ESO)\u2014European Society for Minimally Invasive Neurological Therapy (ESMINT) Guidelines on Mechanical Thrombectomy in Acute Ischemic Stroke","volume":"15","author":"Turc","year":"2023","journal-title":"J. Neurointerv. Surg."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"4138","DOI":"10.1007\/s00330-020-07543-9","article-title":"Dual-energy computed tomography in acute ischemic stroke: State-of-the-art","volume":"31","author":"Mangesius","year":"2021","journal-title":"Eur. Radiol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"907","DOI":"10.1007\/s00330-016-4412-5","article-title":"Prediction of infarction development after endovascular stroke therapy with dual-energy computed tomography","volume":"27","author":"Djurdjevic","year":"2017","journal-title":"Eur. Radiol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"2205","DOI":"10.3174\/ajnr.A5872","article-title":"Differentiation of Hemorrhage from Iodine Using Spectral Detector CT: A Phantom Study","volume":"39","author":"Hokamp","year":"2018","journal-title":"Am. J. Neuroradiol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"441","DOI":"10.3174\/ajnr.A5513","article-title":"Iodine Extravasation Quantification on Dual-Energy CT of the Brain Performed after Mechanical Thrombectomy for Acute Ischemic Stroke Can Predict Hemorrhagic Complications","volume":"39","author":"Bonatti","year":"2018","journal-title":"Am. J. Neuroradiol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"64","DOI":"10.3174\/ajnr.A6345","article-title":"Prediction of Hemorrhage after Successful Recanalization in Patients with Acute Ischemic Stroke: Improved Risk Stratification Using Dual-Energy CT Parenchymal Iodine Concentration Ratio Relative to the Superior Sagittal Sinus","volume":"41","author":"Byrne","year":"2020","journal-title":"Am. J. Neuroradiol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"183","DOI":"10.3174\/ajnr.A8093","article-title":"Discrimination of Hemorrhage and Contrast Media in a Head Phantom on Photon-Counting Detector CT Data","volume":"45","author":"Risch","year":"2024","journal-title":"Am. J. Neuroradiol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"3752","DOI":"10.1002\/mp.14241","article-title":"Multi-energy computed tomography and material quantification: Current barriers and opportunities for advancement","volume":"47","author":"Jacobsen","year":"2020","journal-title":"Med. Phys."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"729","DOI":"10.1148\/rg.2019180115","article-title":"Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology","volume":"39","author":"Leng","year":"2019","journal-title":"Radiographics"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"472","DOI":"10.1097\/RLI.0000000000000984","article-title":"Advanced Neuroimaging With Photon-Counting Detector CT","volume":"58","author":"Abel","year":"2023","journal-title":"Investig. Radiol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"e881","DOI":"10.1002\/mp.14157","article-title":"Principles and applications of multienergy CT: Report of AAPM Task Group 291","volume":"47","author":"McCollough","year":"2020","journal-title":"Med. Phys."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1589","DOI":"10.3174\/ajnr.A7671","article-title":"Quantitative Intracerebral Iodine Extravasation in Risk Stratification for Intracranial Hemorrhage in Patients with Acute Ischemic Stroke","volume":"43","author":"Ma","year":"2022","journal-title":"Am. J. Neuroradiol."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1148\/radiol.10091806","article-title":"Evaluation of dual-energy CT for differentiating intracerebral hemorrhage from iodinated contrast material staining","volume":"257","author":"Gupta","year":"2010","journal-title":"Radiology"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1088","DOI":"10.3174\/ajnr.A2909","article-title":"Differentiation of hemorrhage from iodinated contrast in different intracranial compartments using dual-energy head CT","volume":"33","author":"Phan","year":"2012","journal-title":"Am. J. Neuroradiol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"e1068","DOI":"10.1212\/WNL.0000000000008093","article-title":"Dual energy CT after stroke thrombectomy alters assessment of hemorrhagic complications","volume":"93","author":"Almqvist","year":"2019","journal-title":"Neurology"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"834","DOI":"10.1007\/s00330-013-3073-x","article-title":"The role of dual energy CT in differentiating between brain haemorrhage and contrast medium after mechanical revascularisation in acute ischaemic stroke","volume":"24","author":"Tijssen","year":"2014","journal-title":"Eur. Radiol."}],"container-title":["Diagnostics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4418\/16\/18\/2915\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T04:11:33Z","timestamp":1789099893000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4418\/16\/18\/2915"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,9]]},"references-count":16,"journal-issue":{"issue":"18","published-online":{"date-parts":[[2026,9]]}},"alternative-id":["diagnostics16182915"],"URL":"https:\/\/doi.org\/10.3390\/diagnostics16182915","relation":{},"ISSN":["2075-4418"],"issn-type":[{"value":"2075-4418","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,9]]}}}