{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T14:09:31Z","timestamp":1789999771495,"version":"4.0.1"},"reference-count":20,"publisher":"MDPI AG","issue":"18","license":[{"start":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T00:00:00Z","timestamp":1789689600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Diagnostics"],"abstract":"<jats:p>Background: Analytical variability in magnesium (Mg) assays is widely recognized, yet distinguishing its impact from intrinsic clinical risk remains under-emphasized in laboratory training. Methods: A routine delta check identified atypical Mg result shifts, prompting investigation and retesting on an alternate analyzer. Analytical error magnitude was quantified using absolute and percent difference and total allowable error (TEa), with clinical relevance assessed through integrated analytical verification, agreement analysis, and patient-level risk stratification. Results: A lapse in delta check containment allowed continued reporting after initial error detection. Root cause analysis (RCA) identified Mg reagent contamination and incomplete cuvette drying, causing carryover and positive bias. Among 93 samples, 59 were impacted, with deviations reaching 147.4%, and 63% (59\/93) exceeded TEa. Despite substantial analytical bias, clinical impact was limited: 27% (16\/59) remained within the reference interval and 53% (31\/59) had \u22643.5 mg\/dL, requiring no urgent attention. The remaining 20% (12\/59) were &gt;3.5 mg\/dL, and 11\/12 lacked an Mg-elevating condition (e.g., chronic kidney disease (CKD)) and required no intervention. The single CKD patient had persistently elevated Mg levels before and after correction, with no effect on interpretation, management, or monitoring. All affected results were corrected and communicated to providers. Only 1\/59 (~2%) required follow-up monitoring, with no definite cause identified. Conclusions: This investigation demonstrates that the significance of analytical error is defined as much by clinical context as magnitude. The study identifies assay-specific and system-level vulnerabilities, particularly a gap between error detection and response. These findings underscore the need for integrated analytical, clinical, and operational safeguards and formalizing these competencies within training programs to improve laboratory quality, reliability, and practice consistency.<\/jats:p>","DOI":"10.3390\/diagnostics16183029","type":"journal-article","created":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T12:50:03Z","timestamp":1789995003000},"page":"3029","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Beyond the Numbers: Assessing Clinical Risk Associated with Significant Magnesium Assay Bias"],"prefix":"10.3390","volume":"16","author":[{"given":"Mizanu","family":"Berihun","sequence":"first","affiliation":[{"name":"William P. Jr. Clements University Hospital, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kefyalew","family":"Jaleta","sequence":"additional","affiliation":[{"name":"William P. Jr. Clements University Hospital, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shishir","family":"Adhikari","sequence":"additional","affiliation":[{"name":"William P. Jr. Clements University Hospital, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kimberly","family":"Fankhauser","sequence":"additional","affiliation":[{"name":"William P. Jr. Clements University Hospital, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alagarraju","family":"Muthukumar","sequence":"additional","affiliation":[{"name":"William P. Jr. Clements University Hospital, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA"},{"name":"Department of Pathology, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Madhusudhanan","family":"Narasimhan","sequence":"additional","affiliation":[{"name":"William P. Jr. Clements University Hospital, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA"},{"name":"Department of Pathology, University of Texas Southwestern Medical Center, Dallas, TX 75235, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,9,18]]},"reference":[{"key":"ref_1","first-page":"e68385","article-title":"A Comprehensive review on understanding magnesium disorders: Pathophysiology, clinical manifestations, and management strategies","volume":"16","author":"Kothari","year":"2024","journal-title":"Cureus"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1515\/cclm-2023-0537","article-title":"Improving diagnosis and treatment of hypomagnesemia","volume":"62","author":"Salinas","year":"2023","journal-title":"Clin. Chem. Lab Med."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1042\/CS20120045","article-title":"Drug-induced alterations in Mg homoeostasis","volume":"123","author":"Lameris","year":"2012","journal-title":"Clin. Sci."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Ma, C., Li, X., Luo, W., Hou, L., Sun, D., Liu, L., Liu, X., Zhang, Y., Xu, J., and Qiu, L. (2026). Real-world study: Assessing the impact of hemolysis on 48 biochemical and immunological analytes through big data analysis and its feasibility validation. PLoS ONE, 21.","DOI":"10.1371\/journal.pone.0340265"},{"key":"ref_5","first-page":"e49835","article-title":"The laboratory and clinical perspectives of magnesium imbalance","volume":"15","author":"Nordin","year":"2023","journal-title":"Cureus"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1093\/jalm\/jfaf160","article-title":"An overview of allowable total error in the clinical laboratory","volume":"11","author":"Campbell","year":"2026","journal-title":"J. Appl. Lab Med."},{"key":"ref_7","first-page":"417","article-title":"Estimation of change limits (deltacheck) in clinical laboratory","volume":"2","year":"2021","journal-title":"Adv. Lab Med."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1373\/jalm.2016.022020","article-title":"To delta check or not to delta check? That is the question","volume":"1","author":"Karger","year":"2017","journal-title":"J. Appl. Lab Med."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"813","DOI":"10.5858\/arpa.2016-0161-CP","article-title":"Delta Check Practices and Outcomes: A Q-probes study involving 49 health care facilities and 6541 delta check alerts","volume":"141","author":"Schifman","year":"2017","journal-title":"Arch. Pathol. Lab Med."},{"key":"ref_10","unstructured":"Yu, A.S.L., and Gupta, A. (2026, July 14). Hypermagnesemia: Clinical Manifestations and Management. UpToDate, Available online: https:\/\/www.uptodate.com\/contents\/hypermagnesemia-causes-clinical-manifestations-evaluation-and-treatment\/print."},{"key":"ref_11","unstructured":"Longo, D.L.F.A., Kasper, D., Hauser, L., Jameson, S.L., and Loscalzo, J.L. (2012). Bone and mineral metabolism in health and disease. Harrison\u2019s Principles of Internal Medicine, McGraw-Hill. [18th ed.]."},{"key":"ref_12","first-page":"504","article-title":"Interpreting magnesium status to enhance clinical care: Key indicators","volume":"20","author":"Costello","year":"2017","journal-title":"Curr. Opin. Clin. Nutr. Metab. Care"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1001","DOI":"10.1093\/jalm\/jfae066","article-title":"Selection of Single-Analyte Delta Check Rules with Logistic Regression for Detection of Intravenous Fluid Contamination in a Clinical Chemistry Laboratory","volume":"9","author":"Yang","year":"2024","journal-title":"J. Appl. Lab Med."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"8853568","DOI":"10.1155\/ianc\/8853568","article-title":"Comparative Analysis of serum magnesium ion levels using three measurement methods: Spectrophotometry, atomic absorption spectrophotometry, and inductively coupled plasma with optical emission spectrophotometry","volume":"2025","author":"Kurniati","year":"2025","journal-title":"Int. J. Anal. Chem."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"921","DOI":"10.7754\/Clin.Lab.2015.150944","article-title":"Evaluation of the bias of serum magnesium measurements and the commutability of processed materials","volume":"62","author":"Ge","year":"2016","journal-title":"Clin. Lab"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1515\/CCLM.2010.024","article-title":"Managing quality vs. measuring uncertainty in the medical laboratory","volume":"48","author":"Westgard","year":"2010","journal-title":"Clin. Chem. Lab Med."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"e24306","DOI":"10.1016\/j.heliyon.2024.e24306","article-title":"Ensure the accuracy and consistency of biochemical analyzer test results: Chemometrics for instrument and inter-instrument item comparison in Chinese hospital laboratory","volume":"10","author":"Song","year":"2024","journal-title":"Heliyon"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"705","DOI":"10.1309\/MMLEYHNBY4WA12J6","article-title":"Reagent carryover studies: Preventing analytical error with open clinical chemistry systems","volume":"36","author":"Boneno","year":"2005","journal-title":"Lab Med."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1363","DOI":"10.1373\/clinchem.2018.300954","article-title":"Toward a framework for outcome-based analytical performance specifications: A methodology review of indirect methods for evaluating the impact of measurement uncertainty on clinical outcomes","volume":"65","author":"Smith","year":"2019","journal-title":"Clin. Chem."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1317","DOI":"10.1093\/clinchem\/hvad132","article-title":"Linking laboratory testing to clinical outcomes: Bridging the gap through outcome-based studies in laboratory medicine","volume":"69","author":"Gounden","year":"2023","journal-title":"Clin. Chem."}],"container-title":["Diagnostics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4418\/16\/18\/3029\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T13:19:43Z","timestamp":1789996783000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4418\/16\/18\/3029"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,18]]},"references-count":20,"journal-issue":{"issue":"18","published-online":{"date-parts":[[2026,9]]}},"alternative-id":["diagnostics16183029"],"URL":"https:\/\/doi.org\/10.3390\/diagnostics16183029","relation":{},"ISSN":["2075-4418"],"issn-type":[{"value":"2075-4418","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,18]]}}}