{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T09:05:37Z","timestamp":1790759137129,"version":"4.1.0"},"reference-count":40,"publisher":"MDPI AG","issue":"19","license":[{"start":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T00:00:00Z","timestamp":1790726400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Diagnostics"],"abstract":"<jats:p>Background\/Objectives: Fractures of the distal humerus and olecranon often require surgical intervention due to their complexity and intra-articular fracture pattern. Precise implant positioning and articular surface reconstruction are crucial for optimal outcomes. Intraoperative 3D imaging offers advantages over 2D fluoroscopy by providing enhanced visualization of fracture reduction and implant alignment. However, limited space in the prone position restricts the use of standard 3D imaging with complete orbital rotation. This cadaver study investigates the feasibility and intra-articular screw detection performance of intraoperative 3D tomosynthesis with reduced orbital rotation at the elbow. Methods: In this cadaver study, six distal humeri and six olecranons were examined using an isocentric 3D C-arm with a complete 200\u00b0 acquisition. The disarticulated upper extremities were positioned to reproduce the prone surgical setup. Reduced-angle datasets ranging from 200\u00b0 to 100\u00b0 were reconstructed retrospectively from the complete acquisition, with and without metal artifact reduction (MAR). Double-plate osteosynthesis was applied to the distal humerus, while an anatomic olecranon plate was used for fixation on the olecranon. To evaluate detection capabilities, screw positions were deliberately modified to include both correct placements and intra-articular malpositions. Image quality (5-point Likert scale) and certainty of intra-articular screw assessment were evaluated by three blinded raters; sensitivity and specificity were calculated relative to the complete 200\u00b0 imaging-based reference condition. Results: Image quality, sensitivity, and specificity decreased with reduced orbital rotation. MAR significantly improved image quality and specificity, but not sensitivity. At an orbital rotation of 160\u00b0, MAR-reconstructed tomosynthesis achieved acceptable image quality (3.36 \u00b1 0.53), high sensitivity (94.9%), and high specificity (93.9%) for detecting intra-articular screws. Conclusions: Intraoperative tomosynthesis with MAR provides acceptable image quality and high performance for intra-articular screw detection at the elbow under the present experimental conditions. This approach may support intraoperative assessment in prone-position elbow surgery when full orbital rotation is not feasible. Clinical studies are needed to confirm its value in routine practice.<\/jats:p>","DOI":"10.3390\/diagnostics16193178","type":"journal-article","created":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T08:17:27Z","timestamp":1790756247000},"page":"3178","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Intraoperative 3D Tomosynthesis of the Elbow in a Simulated Prone-Position Setup: A Cadaveric Study"],"prefix":"10.3390","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0009-0003-3539-4839","authenticated-orcid":false,"given":"Benno","family":"Bullert","sequence":"first","affiliation":[{"name":"BG Klinik Ludwigshafen, Department for Orthopaedics and Trauma Surgery at Heidelberg University, 67071 Ludwigshafen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"conceptualization","vocabulary":"credit"},{"role":"methodology","vocabulary":"credit"},{"role":"formal-analysis","vocabulary":"credit"},{"role":"visualization","vocabulary":"credit"},{"role":"supervision","vocabulary":"credit"},{"role":"project-administration","vocabulary":"credit"},{"role":"writing-original-draft","vocabulary":"credit"}]},{"given":"Livia","family":"Morlock","sequence":"additional","affiliation":[{"name":"BG Klinik Ludwigshafen, Department for Orthopaedics and Trauma Surgery at Heidelberg University, 67071 Ludwigshafen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"software","vocabulary":"credit"},{"role":"formal-analysis","vocabulary":"credit"},{"role":"investigation","vocabulary":"credit"},{"role":"data-curation","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-8113-3786","authenticated-orcid":false,"given":"Fenna","family":"Brunken","sequence":"additional","affiliation":[{"name":"BG Klinik Ludwigshafen, Department for Orthopaedics and Trauma Surgery at Heidelberg University, 67071 Ludwigshafen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"conceptualization","vocabulary":"credit"},{"role":"investigation","vocabulary":"credit"},{"role":"data-curation","vocabulary":"credit"},{"role":"project-administration","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"}]},{"given":"Jula","family":"Gierse","sequence":"additional","affiliation":[{"name":"BG Klinik Ludwigshafen, Department for Orthopaedics and Trauma Surgery at Heidelberg University, 67071 Ludwigshafen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"conceptualization","vocabulary":"credit"},{"role":"methodology","vocabulary":"credit"},{"role":"supervision","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0730-4782","authenticated-orcid":false,"given":"Paul A.","family":"Gruetzner","sequence":"additional","affiliation":[{"name":"BG Klinik Ludwigshafen, Department for Orthopaedics and Trauma Surgery at Heidelberg University, 67071 Ludwigshafen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8024-9276","authenticated-orcid":false,"given":"Sven Y.","family":"Vetter","sequence":"additional","affiliation":[{"name":"BG Klinik Ludwigshafen, Department for Orthopaedics and Trauma Surgery at Heidelberg University, 67071 Ludwigshafen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nils","family":"Beisemann","sequence":"additional","affiliation":[{"name":"BG Klinik Ludwigshafen, Department for Orthopaedics and Trauma Surgery at Heidelberg University, 67071 Ludwigshafen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"},{"role":"conceptualization","vocabulary":"credit"},{"role":"investigation","vocabulary":"credit"},{"role":"data-curation","vocabulary":"credit"},{"role":"supervision","vocabulary":"credit"},{"role":"writing-review-editing","vocabulary":"credit"}]}],"member":"1968","published-online":{"date-parts":[[2026,9,30]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1016\/j.injury.2006.04.130","article-title":"Epidemiology of adult fractures: A review","volume":"37","author":"Caesar","year":"2006","journal-title":"Injury"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s12306-016-0449-5","article-title":"The treatment of olecranon fractures in adults","volume":"101","author":"Powell","year":"2017","journal-title":"Musculoskelet. Surg."},{"key":"ref_3","first-page":"Cd009890","article-title":"Surgical interventions for treating distal humeral fractures in adults","volume":"2013","author":"Wang","year":"2013","journal-title":"Cochrane Database Syst. Rev."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"686","DOI":"10.2106\/JBJS.J.00845","article-title":"Distal humeral fractures in adults","volume":"93","author":"Nauth","year":"2011","journal-title":"J. Bone Jt. Surg."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1007\/s00113-013-2359-4","article-title":"Intraoperative 3-dimensional imaging\u2014Beneficial or necessary?","volume":"116","author":"Franke","year":"2013","journal-title":"Unfallchirurg"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1007\/s00068-022-02083-x","article-title":"Intraoperative revision rates due to three-dimensional imaging in orthopedic trauma surgery: Results of a case series of 4721 patients","volume":"49","author":"Keil","year":"2023","journal-title":"Eur. J. Trauma Emerg. Surg."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1007\/s001130170055","article-title":"Comparative study of the quality of C-arm based 3D imaging of the talus","volume":"104","author":"Euler","year":"2001","journal-title":"Unfallchirurg"},{"key":"ref_8","first-page":"232","article-title":"Intraoperative 3D imaging: Value and consequences in 248 cases","volume":"66","author":"Kendoff","year":"2009","journal-title":"J. Trauma"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"4019","DOI":"10.1016\/j.ejrad.2012.06.021","article-title":"Accuracy and consequences of 3D-fluoroscopy in upper and lower extremity fracture treatment: A systematic review","volume":"81","author":"Beerekamp","year":"2012","journal-title":"Eur. J. Radiol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.knee.2008.07.012","article-title":"Improved intra-operative reduction control using a three-dimensional mobile image intensifier\u2014A proximal tibia cadaver study","volume":"16","author":"Gosling","year":"2009","journal-title":"Knee"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"587","DOI":"10.1007\/s00113-011-2008-8","article-title":"The isocentric C-arm. Visualization of fracture reduction and screw position in the radius","volume":"114","author":"Meier","year":"2011","journal-title":"Unfallchirurg"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1491","DOI":"10.1007\/s00402-017-2763-2","article-title":"Detection of primary screw perforation in locking plate osteosynthesis of proximal humerus fracture by intra-operative 3D fluoroscopy","volume":"137","author":"Theopold","year":"2017","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1007\/s00402-018-2867-3","article-title":"Intraoperative three-dimensional imaging in the treatment of distal radius fractures","volume":"138","author":"Schnetzke","year":"2018","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"ref_14","first-page":"437","article-title":"Multiplanar reconstruction with mobile 3D image intensifier. Surgical treatment of proximal humerus fractures","volume":"117","author":"Hepp","year":"2014","journal-title":"Unfallchirurg"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1016\/j.jcot.2021.04.030","article-title":"Does the use of intraoperative CT scan improve outcomes in Orthopaedic surgery? A systematic review and meta-analysis of 871 cases","volume":"18","author":"Kumar","year":"2021","journal-title":"J. Clin. Orthop. Trauma"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"e72","DOI":"10.2106\/JBJS.L.01220","article-title":"Intraoperative Three-Dimensional Imaging in the Treatment of Calcaneal Fractures","volume":"96","author":"Franke","year":"2014","journal-title":"J. Bone Jt. Surg."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1386","DOI":"10.2106\/JBJS.K.01122","article-title":"Intraoperative Three-Dimensional Imaging in the Treatment of Acute Unstable Syndesmotic Injuries","volume":"94","author":"Franke","year":"2012","journal-title":"J. Bone Jt. Surg."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"e221200","DOI":"10.1148\/radiol.221200","article-title":"Twin Robotic Gantry-Free Cone-Beam CT in Acute Elbow Trauma","volume":"306","author":"Kunz","year":"2023","journal-title":"Radiology"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1186\/s41747-020-00177-y","article-title":"3D cone-beam CT with a twin robotic x-ray system in elbow imaging: Comparison of image quality to high-resolution multidetector CT","volume":"4","author":"Grunz","year":"2020","journal-title":"Eur. Radiol. Exp."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1795","DOI":"10.2106\/00004623-200608000-00016","article-title":"Two and Three-Dimensional Computed Tomography for the Classification and Management of Distal Humeral Fractures: Evaluation of Reliability and Diagnostic Accuracy","volume":"88","author":"Doornberg","year":"2006","journal-title":"J. Bone Jt. Surg."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Schnetzke, M., Fuchs, J., Vetter, S.Y., Beisemann, N., Keil, H., Gr\u00fctzner, P.-A., and Franke, J. (2016). Intraoperative 3D imaging in the treatment of elbow fractures\u2014A retrospective analysis of indications, intraoperative revision rates, and implications in 36 cases. BMC Med. Imaging, 16.","DOI":"10.1186\/s12880-016-0126-z"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1007\/s00064-016-0474-4","article-title":"Distale Humerusfraktur\u2014Zug\u00e4nge und Erweiterungen","volume":"29","author":"Beeres","year":"2017","journal-title":"Oper. Orthop. Traumatol."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1007\/s00117-020-00686-2","article-title":"Diagnosis of upper arm, elbow, and proximal lower arm fractures","volume":"60","author":"Gierer","year":"2020","journal-title":"Radiologe"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"014301","DOI":"10.1118\/1.4770279","article-title":"A review of breast tomosynthesis. Part I. The image acquisition process","volume":"40","author":"Sechopoulos","year":"2013","journal-title":"Med. Phys."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1956","DOI":"10.1118\/1.3120285","article-title":"Tomosynthesis imaging: At a translational crossroads","volume":"36","author":"Dobbins","year":"2009","journal-title":"Med. Phys."},{"key":"ref_26","first-page":"821","article-title":"Comparative study of different intraoperative 3-D image intensifiers in orthopedic trauma care","volume":"66","author":"Kendoff","year":"2009","journal-title":"J. Trauma"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1037\/0033-2909.112.1.155","article-title":"A power primer","volume":"112","author":"Cohen","year":"1992","journal-title":"Psychol. Bull."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1037\/1040-3590.6.4.284","article-title":"Guidelines, criteria, and rules of thumb for evaluating normed and standardized assessment instruments in psychology","volume":"6","author":"Cicchetti","year":"1994","journal-title":"Psychol. Assess."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"4664","DOI":"10.1118\/1.2799492","article-title":"Image quality and localization accuracy in C-arm tomosynthesis-guided head and neck surgery","volume":"34","author":"Bachar","year":"2007","journal-title":"Med. Phys."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1288","DOI":"10.3174\/ajnr.A3851","article-title":"Artifact Reduction of Different Metallic Implants in Flat Detector C-Arm CT","volume":"35","author":"Hung","year":"2014","journal-title":"Am. J. Neuroradiol."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"1136","DOI":"10.1007\/s10278-020-00324-2","article-title":"Evaluation of Software-Based Metal Artifact Reduction in Intraoperative 3D Imaging of the Spine Using a Mobile Cone Beam CT","volume":"33","author":"Privalov","year":"2020","journal-title":"J. Digit. Imaging"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1523","DOI":"10.1007\/s00256-016-2466-8","article-title":"Digital tomosynthesis with metal artifact reduction for assessing cementless hip arthroplasty: A diagnostic cohort study of 48 patients","volume":"45","author":"Tang","year":"2016","journal-title":"Skelet. Radiol."},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Zhang, Z., Yan, M., Tao, K., Xuan, X., Sabol, J., and Lai, H. (2015). Metal Artifact Reduction in Tomosynthesis Imaging, SPIE.","DOI":"10.1117\/12.2080923"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"1419","DOI":"10.1007\/s00402-008-0740-5","article-title":"Does intraoperative fluoroscopic 3D imaging provide extra information for fracture surgery?","volume":"128","author":"Carelsen","year":"2008","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"S19","DOI":"10.1016\/j.otsr.2019.05.021","article-title":"Role of 3D intraoperative imaging in orthopedic and trauma surgery","volume":"106","author":"Tonetti","year":"2020","journal-title":"Orthop. Traumatol. Surg. Res."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"4530","DOI":"10.1038\/s41598-020-61267-w","article-title":"Diagnostic accuracy of intraoperative CT-imaging in complex articular fractures\u2014A cadaveric study","volume":"10","author":"Luxenhofer","year":"2020","journal-title":"Sci. Rep."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"1252","DOI":"10.2106\/00004623-199408000-00016","article-title":"Complex Fractures of the Distal Part of the Humerus and Associated Complications","volume":"76","author":"Jupiter","year":"1994","journal-title":"J. Bone Jt. Surg."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1016\/j.jse.2007.08.012","article-title":"Functional outcome of complex intercondylar fractures of the distal humerus treated through a triceps-sparing approach","volume":"17","author":"Ek","year":"2008","journal-title":"J. Shoulder Elb. Surg."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1016\/j.jhsa.2008.10.023","article-title":"Elbow Fractures: Distal Humerus","volume":"34","author":"Wong","year":"2009","journal-title":"J. Hand Surg."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"055028","DOI":"10.1088\/1361-6560\/ad278e","article-title":"Recovery of the spatially-variant deformations in dual-panel PET reconstructions using deep-learning","volume":"69","author":"Raj","year":"2024","journal-title":"Phys. Med. Biol."}],"container-title":["Diagnostics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2075-4418\/16\/19\/3178\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T08:36:35Z","timestamp":1790757395000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2075-4418\/16\/19\/3178"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,30]]},"references-count":40,"journal-issue":{"issue":"19","published-online":{"date-parts":[[2026,10]]}},"alternative-id":["diagnostics16193178"],"URL":"https:\/\/doi.org\/10.3390\/diagnostics16193178","relation":{},"ISSN":["2075-4418"],"issn-type":[{"value":"2075-4418","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,30]]}}}