{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T03:36:29Z","timestamp":1773200189747,"version":"3.50.1"},"reference-count":55,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2025,3,29]],"date-time":"2025-03-29T00:00:00Z","timestamp":1743206400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Dentistry Journal"],"abstract":"<jats:p>Background: Digital planning and the use of a static surgical guide for implant placement provide predictability and safety for patients and practitioners. The aim of this study was to investigate differences in the accuracy and fit of long and short guides. Methods: In patients with at least one missing tooth, long (supported by the entire dental arch) and short templates (supported by two teeth, mesial and distal) were compared via intraoral scans and the superimposition of the STL files of the initial planning and the actual position in the patient\u2019s mouth along the X-, Y- and Z-axes. Furthermore, this study evaluated the conditions (e.g., mouth opening, the implant position) under which fully guided implantation can be realized. Results: The largest deviation was observed in the Z-axis, although this deviation was not as high for the short templates (0.2275 mm) as it was for the long templates (0.4007 mm). With respect to the 3D deviation (dXYZ), the average deviation from the mean value was 0.2953 mm for the short guides and 0.4360 mm for the long guides (p = 0.002). The effect size (Cohen\u2019s d) was 0.709, which was between the medium (0.50) and large effect sizes (0.80). The shorter templates showed a smaller deviation from the actual plan by 80%. With a mouth opening \u226550 mm, fully guided surgery can be performed in the molar region. In the premolar region, the lower limit was 32 mm. Conclusions: The 3D accuracy was significantly higher for the shorter template, which could therefore be favored.<\/jats:p>","DOI":"10.3390\/dj13040150","type":"journal-article","created":{"date-parts":[[2025,3,31]],"date-time":"2025-03-31T02:50:16Z","timestamp":1743389416000},"page":"150","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Accuracy of Three-Dimensional Computer-Aided Implant Surgical Guides: A Prospective In Vivo Study of the Impact of Template Design"],"prefix":"10.3390","volume":"13","author":[{"given":"Noel","family":"Vartan","sequence":"first","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg, Gl\u00fcckstrasse 11, 91054 Erlangen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lotta","family":"Gath","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg, Gl\u00fcckstrasse 11, 91054 Erlangen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Manuel","family":"Olmos","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg, Gl\u00fcckstrasse 11, 91054 Erlangen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Konstantin","family":"Plewe","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, University Hospital Erlangen of Friedrich-Alexander Universit\u00e4t Erlangen-N\u00fcrnberg, Gl\u00fcckstrasse 11, 91054 Erlangen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christoph","family":"Vogl","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg, Gl\u00fcckstrasse 11, 91054 Erlangen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4317-6834","authenticated-orcid":false,"given":"Marco Rainer","family":"Kesting","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg, Gl\u00fcckstrasse 11, 91054 Erlangen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Manfred","family":"Wichmann","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, University Hospital Erlangen of Friedrich-Alexander Universit\u00e4t Erlangen-N\u00fcrnberg, Gl\u00fcckstrasse 11, 91054 Erlangen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5900-1273","authenticated-orcid":false,"given":"Ragai Edward","family":"Matta","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, University Hospital Erlangen of Friedrich-Alexander Universit\u00e4t Erlangen-N\u00fcrnberg, Gl\u00fcckstrasse 11, 91054 Erlangen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8295-9714","authenticated-orcid":false,"given":"Mayte","family":"Buchbender","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg, Gl\u00fcckstrasse 11, 91054 Erlangen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2025,3,29]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"167","DOI":"10.4012\/dmj.2019-140","article-title":"The development and future of dental implants","volume":"39","author":"Alghamdi","year":"2020","journal-title":"Dent. Mater. J."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1159","DOI":"10.11607\/jomi.7942","article-title":"Fully Guided Versus Half-Guided and Freehand Implant Placement: Systematic Review and Meta-analysis","volume":"35","author":"Barootchi","year":"2020","journal-title":"Int. J. Oral Maxillofac. Implants."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"889","DOI":"10.1111\/clr.13635","article-title":"Static computer-aided, partially guided, and free-handed implant placement: A systematic review and meta-analysis of randomized controlled trials","volume":"31","author":"Tattan","year":"2020","journal-title":"Clin. Oral Implants Res."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1111\/cid.12980","article-title":"Accuracy evaluation of partially guided and fully guided templates applied to implant surgery of anterior teeth: A randomized controlled trial","volume":"23","author":"Lou","year":"2021","journal-title":"Clin. Implant. Dent. Relat. Res."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"29","DOI":"10.2186\/jpr.JPR_D_20_00184","article-title":"The accuracy of implant placement with computer-guided surgery in partially edentulous patients and possible influencing factors: A systematic review and meta-analysis","volume":"66","author":"Putra","year":"2022","journal-title":"J. Prosthodont. Res."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1111\/jcpe.12897","article-title":"A randomized controlled study on the accuracy of free-handed, pilot-drill guided and fully guided implant surgery in partially edentulous patients","volume":"45","author":"Younes","year":"2018","journal-title":"J. Clin. Periodontol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1111\/prd.12175","article-title":"Current state of the art of computer-guided implant surgery","volume":"73","author":"Ackhurst","year":"2017","journal-title":"Periodontol. 2000"},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Khaohoen, A., Powcharoen, W., Sornsuwan, T., Chaijareenont, P., Rungsiyakull, C., and Rungsiyakull, P. (2024). Accuracy of implant placement with computer-aided static, dynamic, and robot-assisted surgery: A systematic review and meta-analysis of clinical trials. BMC Oral Health., 24.","DOI":"10.1186\/s12903-024-04033-y"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1111\/clr.14061","article-title":"An in-vitro analysis of the accuracy of different guided surgery systems \u2014They are not all the same","volume":"34","author":"Guentsch","year":"2023","journal-title":"Clin. Oral Implants Res."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1111\/clr.13904","article-title":"Precision and trueness of computer-assisted implant placement using static surgical guides with open and closed sleeves: An in vitro analysis","volume":"33","author":"Guentsch","year":"2022","journal-title":"Clin. Oral Implants Res."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1147","DOI":"10.1111\/clr.12930","article-title":"Deviations of different systems for guided implant surgery","volume":"28","author":"Laederach","year":"2017","journal-title":"Clin. Oral Implants Res."},{"key":"ref_12","first-page":"e60233","article-title":"Preoperative Assessment for Surgical Accuracy in Maxillofacial Surgery Cases Using Stereolithographic Models","volume":"16","author":"Sameer","year":"2024","journal-title":"Cureus"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1016\/j.sdentj.2023.12.002","article-title":"Computer-assisted navigation in oral and maxillofacial surgery: A systematic review","volume":"36","author":"Alkhayatt","year":"2024","journal-title":"Saudi Dent. J."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"109514","DOI":"10.1016\/j.ejso.2024.109514","article-title":"Intraoperative surgical navigation improves margin status in advanced malignancies of the anterior craniofacial area: A prospective observational study with systematic review of the literature and meta-analysis","volume":"51","author":"Ferrari","year":"2025","journal-title":"Eur. J. Surg. Oncol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1274","DOI":"10.1016\/j.jcms.2024.08.010","article-title":"3-Dimensional accuracy of navigation-guided bimaxillary orthognathic surgery: A systematic review and meta-analysis","volume":"52","author":"Saigo","year":"2024","journal-title":"J. Cranio Maxillofac. Surg."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Einsiedel, D., Giacaman, S.K., Seidel, A., Berger, L., Buchbender, M., Wichmann, M., and Matta, R.E. (2024). Accuracy of full-guided versus half-guided implant procedures carried out with digital implant planning software by students as part of a university curriculum. BMC Med. Educ., 24.","DOI":"10.1186\/s12909-024-06280-7"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1111\/prd.12284","article-title":"Anatomic factors as contributing risk factors in implant therapy","volume":"81","author":"Ramanauskaite","year":"2019","journal-title":"Periodontol. 2000"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1111\/prd.12411","article-title":"Reducing errors in guided implant surgery to optimize treatment outcomes","volume":"88","author":"Chackartchi","year":"2022","journal-title":"Periodontol. 2000"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1111\/clr.13136","article-title":"Static computer-aided implant surgery (s-CAIS) analysing patient-reported outcome measures (PROMs), economics and surgical complications: A systematic review","volume":"29","author":"Joda","year":"2018","journal-title":"Clin. Oral Implants Res."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.aanat.2019.04.005","article-title":"Advantages and disadvantages of implant navigation surgery. A systematic review","volume":"225","author":"Barootchi","year":"2019","journal-title":"Ann. Anat."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"47","DOI":"10.11607\/jomi.8440","article-title":"Vertical Mouth Opening Requirements for CAD\/CAM Fully Guided Implant Surgery: An Analysis of Different Implant Systems","volume":"225","author":"Limmeechokchai","year":"2024","journal-title":"Int. J. Oral Maxillofac. Implants."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Kernen, F., Kramer, J., Wanner, L., Wismeijer, D., Nelson, K., and Flugge, T. (2020). A review of virtual planning software for guided implant surgery\u2014Data import and visualization, drill guide design and manufacturing. BMC Oral Health., 20.","DOI":"10.1186\/s12903-020-01208-1"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"534","DOI":"10.1111\/jopr.13161","article-title":"Comparison of the Accuracy of Implant Position Using Surgical Guides Fabricated by Additive and Subtractive Techniques","volume":"29","author":"Henprasert","year":"2020","journal-title":"J. Prosthodont."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1038\/sj.bdj.2019.44","article-title":"Digital implant planning and guided implant surgery\u2014Workflow and reliability","volume":"226","author":"Schubert","year":"2019","journal-title":"Br. Dent. J."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"804","DOI":"10.1016\/j.jcms.2017.02.015","article-title":"The impact of the fabrication method on the three-dimensional accuracy of an implant surgery template","volume":"45","author":"Matta","year":"2017","journal-title":"J. Cranio Maxillofac. Surg."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research","volume":"15","author":"Koo","year":"2016","journal-title":"J. Chiropr. Med."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1037\/0033-2909.112.1.155","article-title":"A power primer","volume":"112","author":"Cohen","year":"1992","journal-title":"Psychol. Bull."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"175","DOI":"10.3758\/BF03193146","article-title":"G*Power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciences","volume":"39","author":"Faul","year":"2007","journal-title":"Behav. Res. Methods."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"416","DOI":"10.1111\/eje.12964","article-title":"Introducing a novel educational training programme in dental implantology for pregraduate dental students","volume":"28","author":"Fischer","year":"2024","journal-title":"Eur. J. Dent. Educ."},{"key":"ref_30","first-page":"175","article-title":"Accuracy of semi-occlusive CAD\/CAM titanium mesh using the reverse guided bone regeneration digital protocol: A preliminary clinical study","volume":"17","author":"Pellegrino","year":"2024","journal-title":"Int. J. Oral Implantol."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1038\/s41432-021-0216-9","article-title":"Conventional free-hand, dynamic navigation and static guided implant surgery produce similar short-term patient-reported outcome measures and experiences","volume":"22","author":"Afrashtehfar","year":"2021","journal-title":"Evid. Based Dent."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1111\/clr.13862","article-title":"Time and costs related to computer-assisted versus non-computer-assisted implant planning and surgery. A systematic review","volume":"32","author":"Graf","year":"2021","journal-title":"Clin. Oral Implants Res."},{"key":"ref_33","first-page":"105","article-title":"Comparison of the accuracy of pilot-drill-guided and fully guided implant surgery with dynamic navigation. In vitro model study","volume":"51","author":"Demetoglu","year":"2021","journal-title":"J. Oral Implantol."},{"key":"ref_34","unstructured":"Werny, J.G., Fan, S., Diaz, L., Al-Nawas, B., Sagheb, K., Gielisch, M., and Schiegnitz, E. (Clin. Oral Implants Res., 2021). Evaluation of the Accuracy, Surgical Time, and Learning Curve of Freehand, Static, and Dynamic Computer-Assisted Implant Surgery in an In Vitro Study, Clin. Oral Implants Res., ahead of print."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"821","DOI":"10.1016\/j.prosdent.2019.05.027","article-title":"Accuracy and precision of 3D-printed implant surgical guides with different implant systems: An in vitro study","volume":"123","author":"Yeung","year":"2020","journal-title":"J. Prosthet. Dent."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1111\/j.1708-8208.2010.00275.x","article-title":"Accuracy and complications using computer-designed stereolithographic surgical guides for oral rehabilitation by means of dental implants: A review of the literature","volume":"14","author":"Komiyama","year":"2012","journal-title":"Clin. Implant. Dent. Relat. Res."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"101","DOI":"10.11607\/jomi.5556","article-title":"Accuracy of Implant Placement with Computer-Guided Surgery: A Systematic Review and Meta-Analysis Comparing Cadaver, Clinical, and In Vitro Studies","volume":"33","year":"2018","journal-title":"Int. J. Oral Maxillofac. Implants."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"1067","DOI":"10.1111\/clr.13520","article-title":"Influence of surgical guide support and implant site location on accuracy of static Computer-Assisted Implant Surgery","volume":"30","author":"Lazarin","year":"2019","journal-title":"Clin. Oral Implants Res."},{"key":"ref_39","first-page":"234","article-title":"Accuracy of computer-aided oral implant surgery: A clinical and radiographic study","volume":"24","author":"Valente","year":"2009","journal-title":"Int. J. Oral Maxillofac. Implants."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1111\/clr.14384","article-title":"Prospective Clinical Study on the Accuracy of Static Computer-Assisted Implant Surgery in Patients With Distal Free-End Implants. Conventional Versus CAD-CAM Surgical Guides","volume":"36","author":"Berta","year":"2025","journal-title":"Clin. Oral Implants Res."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1563\/aaid-joi-D-21-00055","article-title":"Accuracy of Different Surgical Guide Designs for Static Computer-Assisted Implant Surgery: An In Vitro Study","volume":"48","author":"Wu","year":"2022","journal-title":"J. Oral Implantol."},{"key":"ref_42","doi-asserted-by":"crossref","unstructured":"Nuytens, P., D\u2019Haese, R., and Vandeweghe, S. (2022). Reliability and Time Efficiency of Digital vs. Analog Bite Registration Technique for the Manufacture of Full-Arch Fixed Implant Prostheses. J. Clin. Med, 11.","DOI":"10.3390\/jcm11102882"},{"key":"ref_43","doi-asserted-by":"crossref","unstructured":"Cristache, C.M., Burlacu Vatamanu, O.E., Butnarasu, C.C., Mihut, T., and Sgiea, E.D. (2024). Predictable Full Digital Workflow Using Stackable Surgical Templates for Complete Dental Arch Rehabilitation with Implant-Supported Fixed Restorations-Case Series and Proof of Concept. Dent. J., 12.","DOI":"10.3390\/dj12110347"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"162.e1","DOI":"10.1016\/j.prosdent.2024.09.015","article-title":"Correlation between implant angulation and crestal bone changes: A 5-year retrospective study","volume":"133","author":"Kim","year":"2025","journal-title":"J. Prosthet. Dent."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"690","DOI":"10.1902\/jop.2016.150571","article-title":"Influence of Soft Tissue Thickness on Peri-Implant Marginal Bone Loss: A Systematic Review and Meta-Analysis","volume":"87","author":"Lin","year":"2016","journal-title":"J. Periodontol."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1002\/JPER.19-0716","article-title":"Peri-implant soft tissue phenotype modification and its impact on peri-implant health: A systematic review and network meta-analysis","volume":"92","author":"Tavelli","year":"2021","journal-title":"J. Periodontol."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1111\/prd.12532","article-title":"Emerging factors affecting peri-implant bone metabolism","volume":"94","author":"Insua","year":"2024","journal-title":"Periodontol. 2000"},{"key":"ref_48","doi-asserted-by":"crossref","unstructured":"Schmidt, A., Klussmann, L., Wostmann, B., and Schlenz, M.A. (2020). Accuracy of Digital and Conventional Full-Arch Impressions in Patients: An Update. J. Clin. Med., 9.","DOI":"10.3390\/jcm9030688"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"e12096","DOI":"10.1002\/jeo2.12096","article-title":"Applications and accuracy of 3D-printed surgical guides in traumatology and orthopaedic surgery: A systematic review and meta-analysis","volume":"11","author":"Hess","year":"2024","journal-title":"J. Exp. Orthop."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"328","DOI":"10.11607\/jomi.5799","article-title":"Accuracy of a Template-Guided Implant Surgery System with a CAD\/CAM-Based Measurement Method: An In Vitro Study","volume":"33","author":"Brandt","year":"2018","journal-title":"Int. J. Oral Maxillofac. Implants."},{"key":"ref_51","doi-asserted-by":"crossref","unstructured":"de Almeida, J.C., Soares, M.Q.S., Mamani, M.P., Franco, A., and Junqueira, J.L.C. (J. Prosthet. Dent., 2024). Influence of surgeon experience on implant placement in guided surgeries: A systematic review and meta-analysis of randomized clinical trials, J. Prosthet. Dent., ahead of print.","DOI":"10.1016\/j.prosdent.2024.01.004"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1111\/eje.12447","article-title":"Exploring training dental implant placement using computer-guided implant navigation system for predoctoral students: A pilot study","volume":"23","author":"Bencharit","year":"2019","journal-title":"Eur. J. Dent. Educ."},{"key":"ref_53","doi-asserted-by":"crossref","unstructured":"Wang, X., Shujaat, S., Meeus, J., Shaheen, E., Legrand, P., Lahoud, P., Gerhardt, M.D.N., and Jacobs, R. (2023). Performance of novice versus experienced surgeons for dental implant placement with freehand, static guided and dynamic navigation approaches. Sci. Rep., 13.","DOI":"10.1038\/s41598-023-29633-6"},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"684.e1","DOI":"10.1016\/j.prosdent.2020.06.028","article-title":"Influence of zirconia crown artifacts on cone beam computed tomography scans and image superimposition of tomographic image and tooth surface scan: An in vitro study","volume":"125","author":"Alaidrous","year":"2021","journal-title":"J. Prosthet. Dent."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"S267","DOI":"10.1111\/jcpe.12955","article-title":"The etiology of hard- and soft-tissue deficiencies at dental implants: A narrative review","volume":"45","author":"Hammerle","year":"2018","journal-title":"J. Clin. Periodontol."}],"container-title":["Dentistry Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2304-6767\/13\/4\/150\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T17:05:35Z","timestamp":1760029535000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2304-6767\/13\/4\/150"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,29]]},"references-count":55,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2025,4]]}},"alternative-id":["dj13040150"],"URL":"https:\/\/doi.org\/10.3390\/dj13040150","relation":{},"ISSN":["2304-6767"],"issn-type":[{"value":"2304-6767","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,29]]}}}