{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T12:11:38Z","timestamp":1791807098101,"version":"4.3.4"},"reference-count":53,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T00:00:00Z","timestamp":1780272000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Spanish Government","award":["PID2022-137496OB-I00"],"award-info":[{"award-number":["PID2022-137496OB-I00"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Dentistry Journal"],"abstract":"<jats:p>Background\/Objectives: Peri-implantitis is a common complication affecting approximately 24% of dental implants and is characterized by progressive bone loss and reduced implant stability. Implantoplasty, an intraoral procedure used to remove biofilm by machining the titanium implant surface, has become increasingly common in clinical practice. However, this procedure may compromise the mechanical integrity of implants, especially when combined with peri-implant bone loss, potentially leading to premature fatigue failure. This study evaluated the effect of different marginal bone resection depths, with and without implantoplasty, on the cyclic mechanical behavior of dental implants. Methods: A total of 200 commercially pure grade 4 titanium implants were embedded in resin simulating human bone at depths of 3, 4, and 5 mm. A subset of implants underwent implantoplasty with a 0.4 mm surface reduction corresponding to the thread width. Finite element analysis was performed to evaluate von Mises stress distribution and predict fatigue behavior. Numerical results were experimentally validated using a servo-hydraulic MTS Bionix system under ISO 14801:2016 conditions. Fatigue limits were determined from the asymptotic region of the load\u2013cycles-to-failure (S\u2013N) curves, and fracture surfaces were examined by scanning electron microscopy. Results: Maximum von Mises stresses were concentrated at the thread\u2013body transition and increased with greater marginal resection depth, with additional stress amplification observed after implantoplasty. Fatigue limits for untreated implants were approximately 351 N, 285 N, and 210 N for 3-, 4-, and 5 mm resections, respectively. Implants subjected to 0.4 mm implantoplasty showed fatigue limits of 311 N, 270 N, and 90 N, respectively. Failure patterns were load-dependent: higher loads produced coronal fractures, whereas lower loads resulted in failure at the implant\u2013abutment connection. Finite element predictions showed strong agreement with the experimental results. Conclusions: Excessive marginal resection significantly decreases the fatigue resistance and long-term mechanical reliability of dental implants, particularly when combined with implantoplasty. The main limitations of this study include is in vitro design, the assumptions inherent to the numerical models, and the variability associated with implantoplasty procedures.<\/jats:p>","DOI":"10.3390\/dj14060329","type":"journal-article","created":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T17:11:01Z","timestamp":1780333861000},"page":"329","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Fatigue Behavior of Dental Implants Affected by Peri-Implantitis-Related Bone Loss: Influence of Implantoplasty Evaluated Through In Vitro Testing and Finite Element Modeling"],"prefix":"10.3390","volume":"14","author":[{"given":"Esteban","family":"Padull\u00e9s-Roig","sequence":"first","affiliation":[{"name":"Faculty of Dentistry, Universitat Internacional de Catalunya, Josep Trueta s\/n, 08195 Sant Cugat del Vall\u00e9s, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Darcio","family":"Fonseca","sequence":"additional","affiliation":[{"name":"Bioinspired Oral Biomaterials and Interfaces, Department Ciencia e Ingenieria de Materiales, Escola Enginyeria Barcelona Est, Universitat Polit\u00e8cnica de Catalunya, Av. Eduard Maristany 16, 08019 Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juan Antonio","family":"Callejas-Cano","sequence":"additional","affiliation":[{"name":"Bioinspired Oral Biomaterials and Interfaces, Department Ciencia e Ingenieria de Materiales, Escola Enginyeria Barcelona Est, Universitat Polit\u00e8cnica de Catalunya, Av. Eduard Maristany 16, 08019 Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7094-2966","authenticated-orcid":false,"given":"Luis M.","family":"Delgado","sequence":"additional","affiliation":[{"name":"Bioinspired Oral Biomaterials and Interfaces, Department Expresion Gr\u00e1fica a la Ingenier\u00eda ETSEIAAT, Colom 1, 08222 Terrassa, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Esther","family":"L\u00f3pez-Oliva","sequence":"additional","affiliation":[{"name":"Bioinspired Oral Biomaterials and Interfaces, Department Expresion Gr\u00e1fica a la Ingenier\u00eda ETSEIAAT, Colom 1, 08222 Terrassa, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2969-6067","authenticated-orcid":false,"given":"Conrado","family":"Aparicio","sequence":"additional","affiliation":[{"name":"Bioinspired Oral Biomaterials and Interfaces, Department Ciencia e Ingenieria de Materiales, Escola Enginyeria Barcelona Est, Universitat Polit\u00e8cnica de Catalunya, Av. Eduard Maristany 16, 08019 Barcelona, Spain"},{"name":"ICREA, Instituci\u00f3 Catalana de Recerca i Estudis Avan\u00e7ats, Generalitat de Catalunya, 08010 Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0228-484X","authenticated-orcid":false,"given":"Eugenio","family":"Velasco-Ortega","sequence":"additional","affiliation":[{"name":"Department of Stomatology, Faculty of Dentistry, University of Seville, c\/Avicena s\/n, 41009 Sevilla, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6824-1412","authenticated-orcid":false,"given":"Javier","family":"Gil","sequence":"additional","affiliation":[{"name":"Bioinspired Oral Biomaterials and Interfaces, Department Ciencia e Ingenieria de Materiales, Escola Enginyeria Barcelona Est, Universitat Polit\u00e8cnica de Catalunya, Av. Eduard Maristany 16, 08019 Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,6,1]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"S246","DOI":"10.1111\/jcpe.12954","article-title":"Peri-implantitis","volume":"45","author":"Schwarz","year":"2018","journal-title":"J. Clin. Periodontol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"660","DOI":"10.11607\/jomi.9659","article-title":"Surgical and Nonsurgical Treatment Protocols for Peri-implantitis: An overview of Systematic Reviews","volume":"37","author":"Martins","year":"2022","journal-title":"Int. J. Oral Maxillofac. Implant."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1002\/JPER.21-0103","article-title":"Resolution of peri-implantitis by means of implantoplasty as adjunct to surgical therapy: A retrospective study","volume":"93","author":"Monje","year":"2022","journal-title":"J. Periodontol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1111\/j.1600-051X.2008.01276.x","article-title":"Non-surgical treatment of peri-implant mucositis and peri-implantitis: A literature review","volume":"35","author":"Renvert","year":"2022","journal-title":"J. Clin. Periodontol."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Diaz, P., Gonzalo, E., Villagra, L.J.G., Miegimolle, B., and Suarez, M.J. (2022). What is the prevalence of periimplantitis? A systematic review and meta-analysis. BMC Oral Health, 22.","DOI":"10.1186\/s12903-022-02493-8"},{"key":"ref_6","unstructured":"Thakkar, R. (2025, January 12). Trends in Dental Implants 2022. American Academy of Implant Dentistry. Available online: https:\/\/connect.aaid-implant.org\/blog\/trends-in-dental-implants-2022."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"S146","DOI":"10.4103\/jpbs.jpbs_430_23","article-title":"Impact of the Habit of Alcohol Consumption on the Success of the Implants: A Retrospective Study","volume":"16","author":"Bhatia","year":"2024","journal-title":"J. Pharm. Bioallied Sci."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"2203","DOI":"10.1007\/s00784-020-03534-8","article-title":"Does implantoplasty affect the failure strength of narrow and regular diameter implants? A laboratory study","volume":"25","author":"Bertl","year":"2021","journal-title":"Clin. Oral Investig."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Toledano-Serrabona, J., Gil, F.J., Camps-Font, O., Valmaseda-Castell\u00f3n, E., Gay-Escoda, C., and S\u00e1nchez-Garc\u00e9s, M.\u00c1. (2021). Physicochemical and Biological Characterization of Ti6Al4V Particles Obtained by Implantoplasty: An In Vitro Study. Part I. Materials, 14.","DOI":"10.3390\/ma14216507"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Wu, X., Cai, C., Gil, J., Jantz, E., Al Sakka, Y., Padial-Molina, M., and Su\u00e1rez-L\u00f3pez Del Amo, F. (2022). Characteristics of Particles and Debris Released after Implantoplasty: A Comparative Study. Materials, 15.","DOI":"10.3390\/ma15020602"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1038\/s41529-024-00514-1","article-title":"Dynamic assessment of titanium surface oxides following mechanical damage reveals only partial passivation under inflammatory conditions","volume":"8","author":"Kotsakis","year":"2024","journal-title":"npj Mater. Degrad."},{"key":"ref_12","first-page":"725","article-title":"Effect of Electrolytic Cleaning on Mechanical Properties for Titanium Dental Implants with Surface Contamination","volume":"40","author":"Fonseca","year":"2025","journal-title":"Int. J. Oral Maxillofac. Implant."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1095","DOI":"10.1111\/jre.13273","article-title":"Implant surface modifications and their impact on osseointegration and peri-implant diseases through epigenetic changes: A scoping review","volume":"59","author":"Kunrath","year":"2024","journal-title":"J. Periodontal Res."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"809","DOI":"10.1902\/jop.2016.150684","article-title":"Antimicrobial Agents Used in the Treatment of Peri-Implantitis Alter the Physicochemistry and Cytocompatibility of Titanium Surfaces","volume":"87","author":"Kotsakis","year":"2016","journal-title":"J. Periodontol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1111\/cid.12875","article-title":"Cleaning potential of different air abrasive powders and their impact on implant surface roughness","volume":"22","author":"Matsubara","year":"2020","journal-title":"Clin. Implant Dent. Relat. Res."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"S192","DOI":"10.4103\/jpbs.jpbs_453_23","article-title":"Comparison of the Impact of Two Interdental Cleaning Devices on the Reduction of Bleeding Around Implants","volume":"16","author":"Mahajani","year":"2024","journal-title":"J. Pharm. Bioallied Sci."},{"key":"ref_17","unstructured":"(2016). Dentistry\u2014Implants\u2014Dynamic Loading Test for Endosseous Dental Implants (Standard No. ISO 14801:2016)."},{"key":"ref_18","unstructured":"Callister, W.D., and Rethwisch, D.G. (2018). Materials Science and Engineering: An Introduction, Wiley. [10th ed.]."},{"key":"ref_19","unstructured":"Ramberg, W., and Osgood, W.R. (1943). Description of Stress-Strain Curves by Three Parameters, National Advisory Committee for Aeronautics. Technical Note No. 902."},{"key":"ref_20","unstructured":"Brandt, R., and Rosner, B. (2025, February 25). Fundamentals of Biostatistics, Available online: http:\/\/www.stat.ubc.ca\/~rollin\/stats\/ssize\/n2.html."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1034\/j.1600-051x.2001.028003258.x","article-title":"Osseintegration following treatment of peri-implantitis and replacement of implant components. An experimental study in the dog","volume":"28","author":"Persson","year":"2001","journal-title":"J. Clin. Periodontol."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"106928","DOI":"10.1016\/j.jmbbm.2025.106928","article-title":"Effects of tensile and compressive stress on bone resorption and formation parameters surrounding dental implants","volume":"165","author":"Li","year":"2025","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"758","DOI":"10.1111\/cid.12773","article-title":"Two to six-year disease resolution and marginal bone stability rates of a modified resective-implantoplasty therapy in 32 peri-implantitis cases","volume":"21","author":"Bianchini","year":"2019","journal-title":"Clin. Implant Dent. Relat. Res."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1016\/S0921-5093(97)00806-X","article-title":"Mechanical properties of biomedical titanium alloys","volume":"243","author":"Niinomi","year":"1998","journal-title":"Mater. Sci. Eng. A"},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Fonseca, D., de Tapia, B., Pons, R., Aparicio, C., Guerra, F., Messias, A., and Gil, J. (2024). The Effect of Implantoplasty on the Fatigue Behavior and Corrosion Resistance in Titanium Dental Implants. Materials, 17.","DOI":"10.3390\/ma17122944"},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Toledano-Serrabona, J., S\u00e1nchez-Garc\u00e9s, M.A., Gay-Escoda, C., Valmaseda-Castellon, E., Camps-Font, O., Verdeguer, P., Molmeneu, M., and Gil, F.J. (2021). Mechanical properties and corrosi\u00f3n behavior of Ti6Al4V particles obtained by Implatoplasty. An in vivo study. Part. II. Materials, 14.","DOI":"10.3390\/ma14216519"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"416","DOI":"10.1016\/j.jmbbm.2010.03.006","article-title":"Effect of surface treatments on the fatigue life of titanium for biomedical applications","volume":"3","author":"Pazos","year":"2010","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1825","DOI":"10.1007\/s10856-014-5211-7","article-title":"Implant-abutment connections: Influence of the design on the microgap and their fatigue and fracture behavior of dental implants","volume":"25","author":"Gil","year":"2014","journal-title":"J. Mater. Sci. Mater. Med."},{"key":"ref_29","unstructured":"Sevilla, P. (2025, January 6\u20137). Finite element method in dental implant with implantoplasty treatment. Proceedings of the Congreso Nacional de Materiales, San Sebastian, Spain."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Pissu, G., Flores-Fraile, J., Zubizarreta-Macho, \u00c1., Montiel-Company, J.M., and Lobo-Galindo, A.B. (2025). Effect of the implantoplasty techniques on the fracture resistance of dental implants. Systematic review and meta-analysis. Front Dent. Med., 6.","DOI":"10.3389\/fdmed.2025.1568465"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"e13409","DOI":"10.1111\/cid.13409","article-title":"The Effect of Implantoplasty on Fracture Resistance and Implant Surface Changes: An In Vitro and Finite Element Analysis Study","volume":"27","author":"Goh","year":"2025","journal-title":"Clin. Implant Dent. Relat. Res."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"2270","DOI":"10.1016\/j.joms.2021.06.015","article-title":"Is Implantoplasty Efficacious at Treating Peri-Implantitis? A Systematic Review and Meta-Analysis","volume":"79","author":"Abreu","year":"2021","journal-title":"J. Oral Maxillofac. Surg."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s12663-020-01437-5","article-title":"Surface Roughness of Dental Implant and Osseointegration","volume":"20","author":"Matos","year":"2021","journal-title":"J. Maxillofac. Oral Surg."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1111\/cid.12742","article-title":"On osseointegration in relation to implant surfaces","volume":"21","author":"Albrektsson","year":"2019","journal-title":"Clin. Implant Dent. Relat. Res."},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Sanju\u00e1n \u00c1lvarez, M., Robles, D., Mur, J.G., Fern\u00e1ndez-Hern\u00e1ndez, S., P\u00e9rez-Pevida, E., and Brizuela-Velasco, A. (2024). Residual Stress Homogenization of Hybrid Implants. Bioengineering, 11.","DOI":"10.3390\/bioengineering11111149"},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Zhao, B., Liu, J., Li, X., Liu, C., Gao, J., and Hu, M. (2025). Comparison of residual stress distribution between root-analogue implant and threaded cylindrical implant. BMC Oral Health, 25.","DOI":"10.1186\/s12903-025-06412-5"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"106896","DOI":"10.1016\/j.jmbbm.2025.106896","article-title":"From model validation to biomechanical analysis: In silico study of multirooted root analogue implants using 3D finite element analysis","volume":"164","author":"Aldesoki","year":"2025","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Klein, A., Rasperini, G., Gruber, R., Andrukhov, O., and Rausch-Fan, X. (2025). Electrolytic Cleaning of Dental Implants: A Scoping Review of Clinical Studies. Dent. J., 13.","DOI":"10.3390\/dj13040172"},{"key":"ref_39","doi-asserted-by":"crossref","unstructured":"Schlee, M., Rathe, F., Brodbeck, U., Ratka, C., Weigl, P., and Zipprich, H. (2019). Treatment of Peri-implantitis-Electrolytic Cleaning Versus Mechanical and Electrolytic Cleaning-A Randomized Controlled Clinical Trial-Six-Month Results. J. Clin. Med., 8.","DOI":"10.3390\/jcm8111909"},{"key":"ref_40","first-page":"1043","article-title":"Decontamination of titanium implant surface and re-osseointegration to treat peri-implantitis: A literature review","volume":"27","author":"Subramani","year":"2012","journal-title":"Int. J. Oral Maxillofac. Implant."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"3735","DOI":"10.1007\/s00784-021-04345-1","article-title":"Evidence of re-osseointegration after electrolytic cleaning and regenerative therapy of peri-implantitis in humans: A case report with four implants","volume":"26","author":"Bosshardt","year":"2022","journal-title":"Clin. Oral Investig."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1080\/00016357.2021.1945142","article-title":"Implantoplasty-provoking or reducing inflammation?\u2014A systematic scoping review","volume":"80","author":"Verket","year":"2022","journal-title":"Acta Odontol. Scand."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"210","DOI":"10.4103\/jips.jips_102_23","article-title":"Efficacy of implantoplasty in management of peri-implantitis: A systematic review","volume":"23","author":"Dasgupta","year":"2023","journal-title":"J. Indian Prosthodont. Soc."},{"key":"ref_44","first-page":"7502566","article-title":"Implantoplasty-Aided Prosthetic Rehabilitation for the Management of Peri-Implantitis in Maxilla Reconstructed with Free Fibula Flap: A Clinical Report","volume":"2025","author":"Yerramsetti","year":"2025","journal-title":"Case Rep. Dent."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1002\/cap.10310","article-title":"Ten-year follow-up after peri-implantitis treatment using resective surgery: A case report","volume":"15","author":"Lazarin","year":"2025","journal-title":"Clin. Adv. Periodontics"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1902\/cap.2015.150035","article-title":"Multidisciplinary Treatment for Peri-Implantitis: A 24-Month Follow-Up Case Report","volume":"6","author":"Sapata","year":"2016","journal-title":"Clin. Adv. Periodontics"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"20406223231174816","DOI":"10.1177\/20406223231174816","article-title":"Peri-implantitis management by resective surgery combined with implantoplasty and Er:YAG laser irradiation, accompanied by free gingival graft: A case report","volume":"14","author":"Shiba","year":"2023","journal-title":"Ther. Adv. Chronic Dis."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"e70104","DOI":"10.1002\/cre2.70104","article-title":"Advancing Peri-Implantitis Treatment: A Scoping Review of Breakthroughs in Implantoplasty and Er:YAG Laser Therapies","volume":"11","author":"Mojaver","year":"2025","journal-title":"Clin. Exp. Dent. Res."},{"key":"ref_49","doi-asserted-by":"crossref","unstructured":"Martins, O., Sahrmann, P., Ramos, J., Caramelo, F., Matos, S., and Baptista, I.P. (2022). Implantoplasty Improves Clinical Parameters over a 2-Year Follow-Up: A Case Series. Medicina, 58.","DOI":"10.3390\/medicina58010113"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"466","DOI":"10.11607\/prd.6756","article-title":"Clinical and Radiographic Outcomes of Resective Surgery with Adjunctive Implantoplasty Over a 6- to 11-Year Follow-up: A Case Series","volume":"44","author":"Bianchini","year":"2024","journal-title":"Int. J. Periodontics Restor. Dent."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"761","DOI":"10.1111\/clr.12183","article-title":"Clinical and radiographic outcomes of a combined resective and regenerative approach in the treatment of peri-implantitis: A prospective case series","volume":"25","author":"Matarasso","year":"2014","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_52","first-page":"313","article-title":"Treatment modalities for peri-implant mucositis and peri-implantitis","volume":"26","author":"Renvert","year":"2013","journal-title":"Am. J. Dent."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1111\/idj.12505","article-title":"Surgical treatment of peri-implantitis\u2014Consensus report of working group 4","volume":"69","author":"Khoury","year":"2019","journal-title":"Int. Dent. J."}],"container-title":["Dentistry Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2304-6767\/14\/6\/329\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T17:29:31Z","timestamp":1780334971000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2304-6767\/14\/6\/329"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,1]]},"references-count":53,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2026,6]]}},"alternative-id":["dj14060329"],"URL":"https:\/\/doi.org\/10.3390\/dj14060329","relation":{},"ISSN":["2304-6767"],"issn-type":[{"value":"2304-6767","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,1]]}}}