{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T10:21:20Z","timestamp":1783074080973,"version":"3.54.6"},"reference-count":45,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T00:00:00Z","timestamp":1783036800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Dentistry Journal"],"abstract":"<jats:p>Background: Digital workflows based on computer-aided design and computer-aided manufacturing (CAD\/CAM) enable the modification of the vertical dimension of occlusion (VDO) during occlusal splint design; however, the clinical reproducibility of these digital adjustments compared with conventional methods remains unclear. Objective: This in vitro study aimed to evaluate the accuracy and reproducibility of vertical dimension increase achieved with three different dental CAD software systems. Methods: A standardized STL dataset was used to design occlusal splints with three CAD software systems: ExoCAD DentalCAD (Exocad GmbH, Darmstadt, Germany), InLab SW 23 (Dentsply Sirona, Bensheim, Germany), and Medit Link (Medit Corp., Seoul, South Korea). A conventional articulator-derived condition served as the comparator. Splints were manufactured using Night Guard Firm 2 Midnight resin (SprintRay Inc., Los Angeles, CA, USA), and the vertical dimension was measured with a digital caliper (Mitutoyo Corp., Kanagawa, Japan). Representative STL superimposition was performed using OraCheck 5.0 (Dentsply Sirona, Bensheim, Germany), and biomechanical behavior was assessed using ANSYS Mechanical 2025 R2 (ANSYS Inc., Canonsburg, PA, USA). Data were analyzed using one-way ANOVA followed by Tukey\u2019s HSD post hoc tests, with the significance level set at \u03b1 = 0.05. Results: The CAD systems showed variable accuracy in reproducing the reference vertical dimension; the Medit Link group yielded values closest to the reference (22.80 mm vs. 22.68 mm), the InLab group demonstrated marked overestimation (26.70 mm), and the ExoCAD group presented intermediate values (24.36 mm). One-way ANOVA confirmed statistically significant differences between the four groups for both sides (p &lt; 0.001) with very large effect sizes (\u03b72 &gt; 0.98). Three-dimensional superimposition revealed that the InLab splint presented the smallest mean surface deviation from the control (0.36 mm) and the highest proportion of points within 0.1 mm (59%), whereas Medit Link and ExoCAD showed larger mean global distances (0.83 mm and 0.70 mm, respectively). FEA revealed differences in biomechanical behavior, with the highest representative von Mises stress in the Medit Link geometry and the highest representative total deformation in the ExoCAD geometry. Conclusions: Digital modification of VDO is feasible, but its accuracy and reproducibility depend on the CAD system used. Careful verification of CAD design parameters against a conventional clinical reference is advisable before manufacturing occlusal splints involving vertical dimension modification, while representative 3D superimposition may provide complementary descriptive information.<\/jats:p>","DOI":"10.3390\/dj14070402","type":"journal-article","created":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T07:59:47Z","timestamp":1783065587000},"page":"402","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Accuracy and Reproducibility of Digital Vertical Dimension Increase in Occlusal Splint Design: A Comparative In Vitro Study of Three CAD Software Systems"],"prefix":"10.3390","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5326-681X","authenticated-orcid":false,"given":"Cristian","family":"Abad-Coronel","sequence":"first","affiliation":[{"name":"Research Group in Digital Dentistry and CAD\/CAM Materials, Faculty of Dentistry, Universidad de Cuenca, Cuenca 010107, Ecuador"},{"name":"Faculty of Dentistry, Universidad de Cuenca, Cuenca 010107, Ecuador"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lesly Abigail","family":"Ortiz Miranda","sequence":"additional","affiliation":[{"name":"Faculty of Dentistry, Universidad de Cuenca, Cuenca 010107, Ecuador"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cristina Adelaida","family":"Mari\u00f1o Ar\u00e9valo","sequence":"additional","affiliation":[{"name":"Faculty of Dentistry, Universidad de Cuenca, Cuenca 010107, Ecuador"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8673-0909","authenticated-orcid":false,"given":"C\u00e9sar A.","family":"Palt\u00e1n","sequence":"additional","affiliation":[{"name":"New Materials and Transformation Processes Research Group GiMaT, Universidad Polit\u00e9cnica Salesiana, Cuenca 010107, Ecuador"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1047-398X","authenticated-orcid":false,"given":"Jorge I.","family":"Fajardo","sequence":"additional","affiliation":[{"name":"New Materials and Transformation Processes Research Group GiMaT, Universidad Polit\u00e9cnica Salesiana, Cuenca 010107, Ecuador"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaime","family":"Larriva","sequence":"additional","affiliation":[{"name":"Faculty of Dentistry, Universidad de Cuenca, Cuenca 010107, Ecuador"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carolina","family":"Encalada","sequence":"additional","affiliation":[{"name":"Faculty of Dentistry, Universidad de Cuenca, Cuenca 010107, Ecuador"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,7,3]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"104813","DOI":"10.1016\/j.jmbbm.2021.104813","article-title":"Characterization of occlusal splint materials: CAD-CAM versus conventional resins","volume":"124","author":"Gibreel","year":"2021","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"957","DOI":"10.1016\/j.dental.2023.08.178","article-title":"Evaluation of flexible three-dimensionally printed occlusal splint materials: An in vitro study","volume":"39","author":"Gibreel","year":"2023","journal-title":"Dent. Mater."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Pillai, S., Upadhyay, A., Khayambashi, P., Farooq, I., Sabri, H., Tarar, M., Lee, K.T., Harb, I., Zhou, S., and Wang, Y. (2021). Dental 3D-Printing: Transferring Art from the Laboratories to the Clinics. Polymers, 13.","DOI":"10.3390\/polym13010157"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1080\/23337931.2018.1497491","article-title":"Clinical comparison of conventional and additive manufactured stabilization splints","volume":"4","author":"Berntsen","year":"2018","journal-title":"Acta Biomater. Odontol. Scand."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"419","DOI":"10.11607\/ijp.7270","article-title":"Digital and Analog Vertical Dimension Measurements: A Clinical Observational Study","volume":"34","author":"Mosier","year":"2021","journal-title":"Int. J. Prosthodont."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Ainoosah, S., Farghal, A.E., Alzemei, M.S., Saini, R.S., Gurumurthy, V., Quadri, S.A., Okshah, A., Mosaddad, S.A., and Heboyan, A. (2024). Comparative analysis of different types of occlusal splints for the management of sleep bruxism: A systematic review. BMC Oral Health, 24.","DOI":"10.1186\/s12903-023-03782-6"},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Yildiz Domanic, K., Aslan, Y.U., and Ozkan, Y. (2020). Two-body wear of occlusal splint materials against different antagonists. BMC Oral Health, 20.","DOI":"10.1186\/s12903-020-01165-9"},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Abad-Coronel, C., Ruano Espinosa, C., Ord\u00f3\u00f1ez Palacios, S., Palt\u00e1n, C.A., and Fajardo, J.I. (2023). Comparative Analysis between Conventional Acrylic, CAD\/CAM Milled, and 3D CAD\/CAM Printed Occlusal Splints. Materials, 16.","DOI":"10.3390\/ma16186269"},{"key":"ref_9","first-page":"181","article-title":"CAD\/CAM splints for the functional and esthetic evaluation of newly defined occlusal dimensions","volume":"48","author":"Edelhoff","year":"2017","journal-title":"Quintessence Int."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Abad-Coronel, C., Portocarrero Miranda, M., and Malla Bernal, K. (2025). Assessment of the intercanine gingival zenith (or CEJ) distance as a method for determining occlusal vertical dimension (OVD): A cross-sectional observational study. BMC Res. Notes, 19.","DOI":"10.1186\/s13104-025-07571-y"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"135","DOI":"10.2147\/CCIDE.S453704","article-title":"Increasing Vertical Dimension of Occlusion (VDO): Review","volume":"16","author":"Yadfout","year":"2024","journal-title":"Clin. Cosmet. Investig. Dent."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1080\/08869634.2020.1853464","article-title":"Can hard and\/or soft occlusal splints reduce the bite force transmitted to the teeth and temporomandibular joint discs? A finite element method analysis","volume":"41","author":"Silva","year":"2023","journal-title":"Cranio"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Gholampour, S., Gholampour, H., and Khanmohammadi, H. (2019). Finite element analysis of occlusal splint therapy in patients with bruxism. BMC Oral Health, 19.","DOI":"10.1186\/s12903-019-0897-z"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"e277","DOI":"10.1016\/j.ajodo.2021.09.011","article-title":"Finite element analysis of various thickness occlusal stabilization splint therapy on unilateral temporomandibular joint anterior disc displacement without reduction","volume":"161","author":"He","year":"2022","journal-title":"Am. J. Orthod. Dentofac. Orthop."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1016\/j.prosdent.2017.12.023","article-title":"Parafunctional loading and occlusal device on stress distribution around implants: A 3D finite element analysis","volume":"120","author":"Idogava","year":"2018","journal-title":"J. Prosthet. Dent."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"530","DOI":"10.1590\/S1806-83242012005000026","article-title":"The effect of a Lucia jig for 30 minutes on neuromuscular re-programming, in normal subjects","volume":"26","author":"Nassar","year":"2012","journal-title":"Braz. Oral Res."},{"key":"ref_17","first-page":"639","article-title":"CAD\/CAM\u2014The Future Is Here: Overview of Restorative Digital Footprint","volume":"47","author":"Neiva","year":"2019","journal-title":"J. Calif. Dent. Assoc."},{"key":"ref_18","unstructured":"ExoCAD (2019). DentalCAD, ExoCAD. Available online: https:\/\/ExoCAD.com\/fileadmin\/content\/brochures\/ExoCAD_brochure_DentalCAD_es_screen.pdf."},{"key":"ref_19","unstructured":"Dentsply Sirona (2019). InLab SW, Dentsply Sirona. Available online: https:\/\/manuals.sirona.com\/."},{"key":"ref_20","unstructured":"MEDIT Corp (2025). Medit Link, MEDIT Corp.. Available online: https:\/\/www.medit.com\/es\/medit-link\/."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1177\/20501684231154320","article-title":"Aesthetic and functional rehabilitation of collapsed occlusal vertical dimension using an advanced digital workflow","volume":"12","author":"Zhivago","year":"2023","journal-title":"Prim. Dent. J."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1699","DOI":"10.1111\/joor.14032","article-title":"Comparative Efficacy of Digital 3D-Printed and Conventional Stable Occlusal Splints in the Treatment of Temporomandibular Disorders","volume":"52","author":"Qin","year":"2025","journal-title":"J. Oral Rehabil."},{"key":"ref_23","unstructured":"(1994). Accuracy (Trueness and Precision) of Measurement Methods and Results\u2014Part 1: General Principles and Definitions (Standard No. ISO 5725-1:1994)."},{"key":"ref_24","unstructured":"Dentsply Sirona (2023). OraCheck 5.0\u2014Software for the Comparative Evaluation of STL Datasets, Version 5.0, Dentsply Sirona. Available online: https:\/\/www.dentsplysirona.com\/."},{"key":"ref_25","unstructured":"Cohen, J. (1988). Statistical Power Analysis for the Behavioral Sciences, Lawrence Erlbaum Associates. [2nd ed.]."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1016\/j.prosdent.2015.09.011","article-title":"In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions","volume":"115","author":"Ender","year":"2016","journal-title":"J. Prosthet. Dent."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1038\/sj.bdj.4802708","article-title":"The estimation of cement film thickness by an in vivo technique","volume":"131","author":"McLean","year":"1971","journal-title":"Br. Dent. J."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1111\/joor.12205","article-title":"A systematic review of CAD\/CAM fit restoration evaluations","volume":"41","author":"Boitelle","year":"2014","journal-title":"J. Oral Rehabil."},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Imburgia, M., Logozzo, S., Hauschild, U., Veronesi, G., Mangano, C., and Mangano, F.G. (2017). Accuracy of four intraoral scanners in oral implantology: A comparative in vitro study. BMC Oral Health, 17.","DOI":"10.1186\/s12903-017-0383-4"},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Mangano, F., Gandolfi, A., Luongo, G., and Logozzo, S. (2017). Intraoral scanners in dentistry: A review of the current literature. BMC Oral Health, 17.","DOI":"10.1186\/s12903-017-0442-x"},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Lin, Y.C., Scialabba, R., Lee, J.D., Sun, J., and Lee, S.J. (2022). Assessment of Occlusal Vertical Dimension Change in Mechanical and Virtual Articulation: A Pilot Study. Dent. J., 10.","DOI":"10.3390\/dj10110212"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1007\/s44445-025-00066-3","article-title":"Comparative evaluation of virtual articulators in simulating occlusal contacts: An in vitro study","volume":"37","author":"Martani","year":"2025","journal-title":"Saudi Dent. J."},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"\u0160imunovi\u0107, L., \u0106imi\u0107, S., and Me\u0161trovi\u0107, S. (2025). Three-Dimensionally Printed Splints in Dentistry: A Comprehensive Review. Dent. J., 13.","DOI":"10.3390\/dj13070312"},{"key":"ref_34","first-page":"441","article-title":"Applications of 3D printing techniques for occlusal splints used in bruxism","volume":"16","author":"Popescu","year":"2024","journal-title":"Rom. J. Oral Rehabil."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1016\/j.prosdent.2016.09.024","article-title":"Evaluation of the accuracy of 7 digital scanners: An in vitro analysis based on 3-dimensional comparisons","volume":"118","author":"Renne","year":"2017","journal-title":"J. Prosthet. Dent."},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Mangano, F.G., Hauschild, U., Veronesi, G., Imburgia, M., Mangano, C., and Admakin, O. (2019). Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: A comparative in vitro study. BMC Oral Health, 19.","DOI":"10.1186\/s12903-019-0792-7"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1177\/23202068251317825","article-title":"3D-Printed Occlusal Splints: A Narrative Literature Review","volume":"16","author":"Tribst","year":"2025","journal-title":"J. Adv. Oral Res."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"105461","DOI":"10.1016\/j.jdent.2024.105461","article-title":"Accuracy of occlusal splints printed in different orientations by liquid crystal display technology: An in vitro study","volume":"152","author":"Simionato","year":"2025","journal-title":"J. Dent."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"4607","DOI":"10.1007\/s00784-020-03329-x","article-title":"Accuracy of CAD\/CAM-fabricated bite splints: Milling vs 3D printing","volume":"24","author":"Marcel","year":"2020","journal-title":"Clin. Oral Investig."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/j.jdent.2017.12.006","article-title":"Accuracy and precision of 3 intraoral scanners and accuracy of conventional impressions: A novel in vivo analysis method","volume":"69","author":"Nedelcu","year":"2018","journal-title":"J. Dent."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"1271","DOI":"10.1111\/jerd.13080","article-title":"CAD-CAM and analog occlusal splints comparison based on the amount of occlusal adjustments. 3D analysis of the volumetric changes: A pilot study","volume":"35","author":"Blasi","year":"2023","journal-title":"J. Esthet. Restor. Dent."},{"key":"ref_42","doi-asserted-by":"crossref","unstructured":"Somogyi, A., V\u00e9gh, D., R\u00f3th, I., Heged\u00fcs, T., Schmidt, P., Hermann, P., and G\u00e9czi, Z. (2023). Therapy for Temporomandibular Disorders: 3D-Printed Splints from Planning to Evaluation. Dent. J., 11.","DOI":"10.3390\/dj11050126"},{"key":"ref_43","first-page":"e77451","article-title":"Effectiveness of Occlusal Splints in the Management of Temporomandibular Disorders: Comparisons of Treatment Approaches and Digital Versus Conventional Fabrication Techniques","volume":"17","author":"Albagieh","year":"2025","journal-title":"Cureus"},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Vl\u0103du\u021bu, D.E., Mercu\u021b, R., V\u0103ru\u021b, M.C., Stef\u00e2r\u021b\u0103, A., Mercu\u021b, V., R\u0103doi, A.M., Br\u0103toiu, M.R., Popa, A.D., Popescu, A.M., and Dic\u0103, \u0218. (2025). Assessment of Occlusal Contacts Recorded with the Medit Intraoral Scanner vs. ExoCAD Software. J. Clin. Med., 14.","DOI":"10.3390\/jcm14207378"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"895","DOI":"10.1016\/j.prosdent.2018.01.035","article-title":"Accuracy of nine intraoral scanners at different clinical-relevant ranges","volume":"120","author":"Kim","year":"2018","journal-title":"J. Prosthet. Dent."}],"container-title":["Dentistry Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2304-6767\/14\/7\/402\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T09:55:58Z","timestamp":1783072558000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2304-6767\/14\/7\/402"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,3]]},"references-count":45,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2026,7]]}},"alternative-id":["dj14070402"],"URL":"https:\/\/doi.org\/10.3390\/dj14070402","relation":{},"ISSN":["2304-6767"],"issn-type":[{"value":"2304-6767","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,3]]}}}