{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T09:29:50Z","timestamp":1786699790027,"version":"build-2736575974"},"reference-count":34,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T00:00:00Z","timestamp":1786579200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Dent. J.","Dentistry Journal"],"abstract":"<jats:p>Background: Accurate three-dimensional positioning of dental implants is fundamental for long-term prosthetic success. While static guided surgery and traditional dynamic navigation present intrinsic limitations related to physical bulk or hand\u2013eye coordination (the \u201clook-away\u201d phenomenon), Augmented Reality (AR) via Head-Mounted Displays (HMDs) promises to overcome these barriers by superimposing virtual holograms directly onto the surgical field. Objectives: The aim of this scoping review is to map the existing literature to evaluate the positioning accuracy, workflow efficiency, and ergonomic\/technical barriers of HMD-based AR navigation systems in implant dentistry. Methods: A systematic search was conducted across the PubMed, Scopus, Web of Science, and Cochrane Library databases, following the PRISMA-ScR guidelines. In vitro, ex vivo, and clinical studies utilizing AR headsets (e.g., HoloLens) for implant guidance, reporting quantitative data on accuracy and\/or qualitative data on usability issues, were included. Results: Eleven studies were included (7 in vitro, 1 ex vivo, 3 clinical). Accuracy showed a strong dependence on case complexity: for standard implants, the mean error at the entry point ranged between 0.33 and 1.51 mm, which is comparable to s-CAIS techniques. However, in complex scenarios (zygomatic implants), significant deviations were reported (up to 5.64 mm and 9.60\u00b0). The main barriers to routine adoption identified include tracking instability due to line-of-sight interruption, device weight, and the vergence\u2013accommodation conflict. Conclusions: AR dynamic navigation demonstrates promising potential. Nevertheless, current evidence relies predominantly on in vitro studies that fail to fully replicate real-world surgical complexities. Persistent technical and ergonomic barriers, such as tracking instability and hardware limitations, indicate that the technology remains largely in a preclinical phase and is not yet suitable for routine clinical application. Further advancements toward markerless tracking systems, lighter headsets, and rigorous in vivo trials are required.<\/jats:p>","DOI":"10.3390\/dj14080518","type":"journal-article","created":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T09:31:09Z","timestamp":1786613469000},"page":"518","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Wearable Augmented Reality for Dental Implant Navigation: From Experimental Models to Clinical Application\u2014A Scoping Review"],"prefix":"10.3390","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-9225-9521","authenticated-orcid":false,"given":"Angelo","family":"Auricchio","sequence":"first","affiliation":[{"name":"Department of Medicine, Surgery and Dentistry \u201cScuola Medica Salernitana\u201d, DIPMED, University of Salerno, Via S. Allende, 84084 Baronissi, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2935-4668","authenticated-orcid":false,"given":"Antonio","family":"Lanza","sequence":"additional","affiliation":[{"name":"Department of Medicine, Surgery and Dentistry \u201cScuola Medica Salernitana\u201d, DIPMED, University of Salerno, Via S. Allende, 84084 Baronissi, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-5694-5636","authenticated-orcid":false,"given":"Roberto","family":"Duraccio","sequence":"additional","affiliation":[{"name":"Private Practice, Via Roma 72, 80047 San Giuseppe Vesuviano, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,8,13]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1111\/j.1600-0501.2012.02547.x","article-title":"Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years","volume":"23","author":"Jung","year":"2012","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"176S","DOI":"10.1177\/0022034513504949","article-title":"Long-term Stability of Early Implant Placement with Contour Augmentation","volume":"92","author":"Buser","year":"2013","journal-title":"J. Dent. Res."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"436","DOI":"10.1111\/clr.13309","article-title":"Group 5 ITI Consensus Report: Digital technologies","volume":"29","author":"Wismeijer","year":"2018","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"105256","DOI":"10.1016\/j.jdent.2024.105256","article-title":"Implant placement using mixed reality-based dynamic navigation: A proof of concept","volume":"149","author":"Shusterman","year":"2024","journal-title":"J. Dent."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.jobcr.2024.12.005","article-title":"Dental implant placement accuracy with robotic surgery compared to free-hand, static and dynamic computer assisted techniques: Systematic review and meta-analysis","volume":"15","author":"Sankar","year":"2024","journal-title":"J. Oral Biol. Craniofacial Res."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"416","DOI":"10.1111\/clr.13346","article-title":"The accuracy of static computer-aided implant surgery: A systematic review and meta-analysis","volume":"29","author":"Tahmaseb","year":"2018","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1315","DOI":"10.1111\/clr.12460","article-title":"Depth and lateral deviations in guided implant surgery: An RCT comparing guided surgery with mental navigation or the use of a pilot-drill template","volume":"26","author":"Vercruyssen","year":"2014","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1111\/clr.13136","article-title":"Static computer-aided implant surgery (s-CAIS) analysing patient-reported outcome measures (PROMs), economics and surgical complications: A systematic review","volume":"29","author":"Joda","year":"2018","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1016\/j.joms.2015.09.022","article-title":"Static or Dynamic Navigation for Implant Placement\u2014Choosing the Method of Guidance","volume":"74","author":"Block","year":"2016","journal-title":"J. Oral Maxillofac. Surg."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"S44","DOI":"10.1016\/j.jds.2024.09.004","article-title":"Implant position accuracy using dynamic computer-assisted implant surgery (CAIS) combined with augmented reality: A randomized controlled clinical trial","volume":"19","author":"Arunjaroensuk","year":"2024","journal-title":"J. Dent. Sci."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1162\/pres.1997.6.4.355","article-title":"A Survey of Augmented Reality","volume":"6","author":"Azuma","year":"1997","journal-title":"PRESENCE Virtual Augment. Real."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"610","DOI":"10.1034\/j.1600-0501.2002.130606.x","article-title":"Computer-enhanced stereoscopic vision in a head-mounted display for oral implant surgery","volume":"13","author":"Wanschitz","year":"2002","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_13","first-page":"1321","article-title":"A Taxonomy of Mixed Reality Visual Displays","volume":"E77-D","author":"Milgram","year":"1994","journal-title":"IEICE Trans. Inf. Syst."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Ayoub, A., and Pulijala, Y. (2019). The application of virtual reality and augmented reality in Oral & Maxillofacial Surgery. BMC Oral Health, 19.","DOI":"10.1186\/s12903-019-0937-8"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Farronato, M., Maspero, C., Lanteri, V., Fama, A., Ferrati, F., Pettenuzzo, A., and Farronato, D. (2019). Current state of the art in the use of augmented reality in dentistry: A systematic review of the literature. BMC Oral Health, 19.","DOI":"10.1186\/s12903-019-0808-3"},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Akulauskas, M., Butkus, K., Rutk\u016bnas, V., Bla\u017eauskas, T., and Jegelevi\u010dius, D. (2023). Implementation of Augmented Reality in Dental Surgery Using HoloLens 2: An In Vitro Study and Accuracy Assessment. Appl. Sci., 13.","DOI":"10.3390\/app13148315"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"104485","DOI":"10.1016\/j.jdent.2023.104485","article-title":"Artificial intelligence and augmented reality for guided implant surgery planning: A proof of concept","volume":"133","author":"Mangano","year":"2023","journal-title":"J. Dent."},{"key":"ref_18","first-page":"101","article-title":"A system for context-aware intraoperative augmented reality in dental implant surgery","volume":"10","author":"Spengler","year":"2014","journal-title":"Int. J. Comput. Assist. Radiol. Surg."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Pellegrino, G., Mangano, C., Mangano, R., Ferri, A., Taraschi, V., and Marchetti, C. (2019). Augmented reality for dental implantology: A pilot clinical report of two cases. BMC Oral Heal., 19.","DOI":"10.1186\/s12903-019-0853-y"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"107560","DOI":"10.1016\/j.compbiomed.2023.107560","article-title":"A novel mixed reality-guided dental implant placement navigation system based on virtual-actual registration","volume":"166","author":"Fan","year":"2023","journal-title":"Comput. Biol. Med."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Rieder, M., Remschmidt, B., Gsaxner, C., Gaessler, J., Payer, M., Zemann, W., and Wallner, J. (2024). Augmented Reality-Guided Extraction of Fully Impacted Lower Third Molars Based on Maxillofacial CBCT Scans. Bioengineering, 11.","DOI":"10.3390\/bioengineering11060625"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"e42040","DOI":"10.2196\/42040","article-title":"Accuracy of Augmented Reality\u2013Assisted Navigation in Dental Implant Surgery: Systematic Review and Meta-analysis","volume":"25","author":"Mai","year":"2023","journal-title":"J. Med. Internet Res."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"e2523","DOI":"10.1002\/rcs.2523","article-title":"Application of an effective marker-less augmented reality image guidance method in dental implant surgery","volume":"19","author":"Dong","year":"2023","journal-title":"Int. J. Med. Robot. Comput. Assist. Surg."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"105052","DOI":"10.1016\/j.jdent.2024.105052","article-title":"Accuracy of implant placement using a mixed reality-based dynamic navigation system versus static computer-assisted and freehand surgery: An in Vitro study","volume":"146","author":"Shusterman","year":"2024","journal-title":"J. Dent."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Baashar, Y., Alkawsi, G., Ahmad, W.N.W., Alomari, M.A., Alhussian, H., and Tiong, S.K. (2023). Towards Wearable Augmented Reality in Healthcare: A Comparative Survey and Analysis of Head-Mounted Displays. Int. J. Environ. Res. Public Health, 20.","DOI":"10.3390\/ijerph20053940"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1016\/j.kjms.2018.01.009","article-title":"Augmented reality (AR) and virtual reality (VR) applied in dentistry","volume":"34","author":"Huang","year":"2018","journal-title":"Kaohsiung J. Med. Sci."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1080\/00016357.2018.1441437","article-title":"Augmented reality in dentistry: A current perspective","volume":"76","author":"Kwon","year":"2018","journal-title":"Acta Odontol. Scand."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"102757","DOI":"10.1016\/j.media.2023.102757","article-title":"The HoloLens in medicine: A systematic review and taxonomy","volume":"85","author":"Gsaxner","year":"2023","journal-title":"Med. Image Anal."},{"key":"ref_29","first-page":"e1035","article-title":"Accuracy of zygomatic dental implant placement using computer-aided static and dynamic navigation systems compared with a mixed reality appliance. An in vitro study","volume":"15","year":"2023","journal-title":"J. Clin. Exp. Dent."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"e18468","DOI":"10.7717\/peerj.18468","article-title":"Accuracy of augmented reality navigated surgery for placement of zygomatic implants: A human cadaver study","volume":"12","author":"Heijtmeijer","year":"2024","journal-title":"PeerJ"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"467","DOI":"10.7326\/M18-0850","article-title":"PRISMA Extension for Scoping Reviews (PRISMA-ScR): Checklist and Explanation","volume":"169","author":"Tricco","year":"2018","journal-title":"Ann. Intern. Med."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"104070","DOI":"10.1016\/j.jdent.2022.104070","article-title":"Accuracy of dental implant placement using augmented reality-based navigation, static computer assisted implant surgery, and the free-hand method: An in vitro study","volume":"119","author":"Kivovics","year":"2022","journal-title":"J. Dent."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"106568","DOI":"10.1016\/j.compbiomed.2023.106568","article-title":"A mixed reality-based navigation method for dental implant navigation method: A pilot study","volume":"154","author":"Liu","year":"2023","journal-title":"Comput. Biol. Med."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1016\/j.jds.2023.05.006","article-title":"Comparison of the accuracy of dental implant placement using dynamic and augmented reality-based dynamic navigation: An in vitro study","volume":"19","author":"Tao","year":"2023","journal-title":"J. Dent. Sci."}],"container-title":["Dentistry Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2304-6767\/14\/8\/518\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T08:41:17Z","timestamp":1786696877000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2304-6767\/14\/8\/518"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,13]]},"references-count":34,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2026,8]]}},"alternative-id":["dj14080518"],"URL":"https:\/\/doi.org\/10.3390\/dj14080518","relation":{},"ISSN":["2304-6767"],"issn-type":[{"value":"2304-6767","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,13]]}}}