{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,27]],"date-time":"2026-05-27T18:18:25Z","timestamp":1779905905028,"version":"3.53.1"},"reference-count":88,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2022,3,31]],"date-time":"2022-03-31T00:00:00Z","timestamp":1648684800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Electronics"],"abstract":"<jats:p>Onboard charging systems (OBCs) convert AC power from an external charging source into a DC voltage used to charge the battery pack of an electric vehicle (EV). OBCs are versatile since they can convert energy from almost every AC source, including standard household electrical receptacles, without needing wall chargers or charging stations. Since the same motor-drive electronics are reconfigured for onboard charging, weight and cost barely increase. However, the power quality and reliability of the OBCs are essential elements for proper grid interconnection. This article reviews the failures of power electronic converters that can be used for onboard charging and their most prominent fault-tolerance techniques. The various fault-tolerance methods are evaluated and compared in terms of complexity, cost, and performance to provide insights for future developments and research directions.<\/jats:p>","DOI":"10.3390\/electronics11071107","type":"journal-article","created":{"date-parts":[[2022,3,31]],"date-time":"2022-03-31T21:33:03Z","timestamp":1648762383000},"page":"1107","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["An Overview on Fault Management for Electric Vehicle Onboard Chargers"],"prefix":"10.3390","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1752-3126","authenticated-orcid":false,"given":"Luis-Fernando","family":"Gaona-C\u00e1rdenas","sequence":"first","affiliation":[{"name":"Electronics Department, Tecnol\u00f3gico Nacional de M\u00e9xico en Celaya, Celaya 38010, Mexico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6363-513X","authenticated-orcid":false,"given":"Nimrod","family":"V\u00e1zquez-Nava","sequence":"additional","affiliation":[{"name":"Electronics Department, Tecnol\u00f3gico Nacional de M\u00e9xico en Celaya, Celaya 38010, Mexico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0853-4950","authenticated-orcid":false,"given":"Omar-Fernando","family":"Ru\u00edz-Mart\u00ednez","sequence":"additional","affiliation":[{"name":"Faculty of Engineering, Universidad Panamericana, Josemaria Escriva de Balaguer 101, Aguascalientes 20290, Mexico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7128-4712","authenticated-orcid":false,"given":"Alejandro","family":"Espinosa-Calder\u00f3n","sequence":"additional","affiliation":[{"name":"Tecnol\u00f3gico Nacional de M\u00e9xico, Regional Center for Optimization and Device Development (CRODE), Diego Arenas Guzm\u00e1n No. 901, Fracc. Zona de Oro 1, Celaya 38020, Mexico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5050-6208","authenticated-orcid":false,"given":"Alejandro-Israel","family":"Barranco-Guti\u00e9rrez","sequence":"additional","affiliation":[{"name":"CONACYT-Tecnol\u00f3gico Nacional de M\u00e9xico en Celaya, Celaya 38010, Mexico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2178-4804","authenticated-orcid":false,"given":"Mart\u00edn-Antonio","family":"Rodr\u00edguez-Licea","sequence":"additional","affiliation":[{"name":"CONACYT-Tecnol\u00f3gico Nacional de M\u00e9xico en Celaya, Celaya 38010, Mexico"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2022,3,31]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"6319","DOI":"10.1109\/TPEL.2014.2304561","article-title":"Survey on Fault-Tolerant Techniques for Power Electronic Converters","volume":"29","author":"Zhang","year":"2014","journal-title":"IEEE Trans. Power Electron."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Kim, S.H., Kim, S.M., Park, S., and Lee, K.B. (2020). Switch Open-Fault Detection for a Three-Phase Hybrid Active Neutral-Point-Clamped Rectifier. Electronics, 9.","DOI":"10.3390\/electronics9091437"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Witczak, M., Mrugalski, M., and Lipiec, B. (2021). Remaining Useful Life Prediction of MOSFETs via the Takagi\u2013Sugeno Framework. Energies, 14.","DOI":"10.3390\/en14082135"},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Li, L. (2016). Fault Detection and Fault-Tolerant Control for Nonlinear Systems, Springer.","DOI":"10.1007\/978-3-658-13020-6"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"4715","DOI":"10.1109\/JESTPE.2020.3016338","article-title":"Modified SVPWM Scheme for Fault-Tolerant Control of AC\u2013DC PWM Converter","volume":"9","author":"Qin","year":"2021","journal-title":"IEEE J. Emerg. Sel. Top. Power Electron."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Im, W.S., Moon, J.J., Kim, J.M., Lee, D.C., and Lee, K.B. (2012, January 5\u20139). Fault tolerant control strategy of 3-phase AC-DC PWM converter under multiple open-switch faults conditions. Proceedings of the 2012 Twenty-Seventh Annual IEEE Applied Power Electronics Conference and Exposition (APEC), Orlando, FL, USA.","DOI":"10.1109\/APEC.2012.6165909"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1539","DOI":"10.1109\/TIA.2013.2255111","article-title":"Diagnosis and Fault-Tolerant Control of Three-Phase AC\u2013DC PWM Converter Systems","volume":"49","author":"Im","year":"2013","journal-title":"IEEE Trans. Ind. Appl."},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Zakaria, A., Marei, M.I., and Sattar, A.A. (2016, January 27\u201329). A fault-tolerant strategy for current controlled PWM rectifier. Proceedings of the 2016 Eighteenth International Middle East Power Systems Conference (MEPCON), Cairo, Egypt.","DOI":"10.1109\/MEPCON.2016.7836931"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"7112","DOI":"10.1109\/JESTPE.2021.3084803","article-title":"Diagnosis and Tolerant Control Methods for an Open-Switch Fault in a Vienna Rectifier","volume":"9","author":"Park","year":"2021","journal-title":"IEEE J. Emerg. Sel. Top. Power Electron."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Chen, J., Chen, A., Xing, X., and Zhang, C. (2017, January 26\u201330). Fault-tolerant control strategy for T-type three-level inverter with neutral-point voltage balancing. Proceedings of the 2017 IEEE Applied Power Electronics Conference and Exposition (APEC), Tampa, FL, USA.","DOI":"10.1109\/APEC.2017.7931187"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"57","DOI":"10.6113\/JPE.2016.16.1.57","article-title":"Fault-Tolerant Strategy to Control a Reverse Matrix Converter for Open-Switch Faults in the Rectifier Stage","volume":"16","year":"2016","journal-title":"J. Power Electron."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1625","DOI":"10.1109\/TIE.2010.2098355","article-title":"A Failure-Detection Strategy for IGBT Based on Gate-Voltage Behavior Applied to a Motor Drive System","volume":"58","author":"Theilliol","year":"2011","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Sobanski, P., and Orlowska-Kowalska, T. (2017, January 22\u201325). Open switch fault diagnosis methods for an AC\/DC line-side converter. Proceedings of the 2017 IEEE International Conference on Industrial Technology (ICIT), Toronto, ON, Canada.","DOI":"10.1109\/ICIT.2017.7915604"},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Zhou, D., and Tang, Y. (2018, January 20\u201324). An Online Open-Circuit Fault Diagnosis and Fault Tolerant Scheme for Three-Phase AC-DC Converters with Model Predictive control. Proceedings of the 2018 International Power Electronics Conference (IPEC-Niigata 2018-ECCE Asia), Niigata, Japan.","DOI":"10.23919\/IPEC.2018.8507836"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"2158","DOI":"10.1109\/JESTPE.2018.2888879","article-title":"A Model Predictive Control-Based Open-Circuit Fault Diagnosis and Tolerant Scheme of Three-Phase AC\u2013DC Rectifiers","volume":"7","author":"Zhou","year":"2019","journal-title":"IEEE J. Emerg. Sel. Top. Power Electron."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"4299","DOI":"10.1109\/TIE.2008.2005244","article-title":"FPGA-Based Real-Time Power Converter Failure Diagnosis for Wind Energy Conversion Systems","volume":"55","author":"Karimi","year":"2008","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"3360","DOI":"10.1109\/TIE.2012.2200214","article-title":"FPGA-Based Reconfigurable Control for Fault-Tolerant Back-to-Back Converter without Redundancy","volume":"60","author":"Shahbazi","year":"2013","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Sobanski, P., and Orlowska-Kowalska, T. (2017, January 19\u201321). IGBT open-circuit fault diagnosis based on the voltage estimation in the line-side AC\/DC converter. Proceedings of the 2017 IEEE 26th International Symposium on Industrial Electronics (ISIE), Edinburgh, UK.","DOI":"10.1109\/ISIE.2017.8001527"},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Cheng, H., Chen, W., Wang, C., and Deng, J. (2018). Open Circuit Fault Diagnosis and Fault Tolerance of Three-Phase Bridgeless Rectifier. Electronics, 7.","DOI":"10.3390\/electronics7110291"},{"key":"ref_20","unstructured":"Bouzekri, A., and Allaoui, T. Fuzzy-Expert System Fault Tolerant Control of IGBT Open Switch Fault for RSC in Wind Turbine System. Proceedings of the 4th International Conference on Electrical Engineering and Control Applications."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Li, J., Lv, H., Shang, S., and Jin, N. (2018, January 20\u201322). Topology and Control of Two-Stage Bidirectional AC\/DC Fault Tolerant Converter. Proceedings of the 2018 5th International Conference on Information Science and Control Engineering (ICISCE), Zhengzhou, China.","DOI":"10.1109\/ICISCE.2018.00207"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"3731","DOI":"10.1109\/TPEL.2016.2582834","article-title":"An Embedded Closed-Loop Fault-Tolerant Control Scheme for Nonredundant VSI-Fed Induction Motor Drives","volume":"32","author":"Zhou","year":"2017","journal-title":"IEEE Trans. Power Electron."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Sun, D., He, Z., He, Y., and Guan, Y. (2007, January 3\u20135). Four-Switch Inverter Fed PMSM DTC with SVM approach for Fault Tolerant operation. Proceedings of the 2007 IEEE International Electric Machines Drives Conference, Antalya, Turkey.","DOI":"10.1109\/IEMDC.2007.382682"},{"key":"ref_24","first-page":"472","article-title":"A comparison of fault-tolerant control strategies for a pmsg-based marine current turbine system under generator-side converter faulty conditions","volume":"13","author":"Toumi","year":"2017","journal-title":"J. Electr. Syst."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"6068","DOI":"10.1109\/TPEL.2020.3030237","article-title":"Fault-Tolerant Control for Multiple Open-Leg Faults in Open-End Winding Permanent Magnet Synchronous Motor System Based on Winding Reconnection","volume":"36","author":"Zuo","year":"2021","journal-title":"IEEE Trans. Power Electron."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Zhou, W., Sun, D., Chen, M., and Lin, B. (2015, January 20\u201324). Simplified PWM for fault tolerant control of open winding PMSM fed by hybrid inverter. Proceedings of the 2015 IEEE Energy Conversion Congress and Exposition (ECCE), Montreal, QC, Canada.","DOI":"10.1109\/ECCE.2015.7310068"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"6790","DOI":"10.1109\/TIE.2016.2581761","article-title":"Independent Control Scheme for Nonredundant Two-Leg Fault-Tolerant Back-to-Back Converter-Fed Induction Motor Drives","volume":"63","author":"Zhou","year":"2016","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"2689","DOI":"10.1109\/TPEL.2014.2342506","article-title":"Multiple Open-Circuit Faults Diagnosis in Back-to-Back Converters of PMSG Drives for Wind Turbine Systems","volume":"30","author":"Jlassi","year":"2015","journal-title":"IEEE Trans. Power Electron."},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Shahbazi, M., Zolghadri, M.R., Poure, P., and Saadate, S. (2013, January 25\u201328). Wind energy conversion system based on DFIG with open switch fault tolerant six-legs AC-DC-AC converter. Proceedings of the 2013 IEEE International Conference on Industrial Technology (ICIT), Cape Town, South Africa.","DOI":"10.1109\/ICIT.2013.6505922"},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Sahraoui, K., Gaoui, B., Mokrani, L., and Belarbi, K. (2016, January 15\u201317). Fault tolerant control of redundant topology of PWM AC-DC-AC converter supplying an electromechanical drive. Proceedings of the 2016 8th International Conference on Modelling, Identification and Control (ICMIC), Algiers, Algeria.","DOI":"10.1109\/ICMIC.2016.7804140"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"2284","DOI":"10.1109\/TIE.2012.2191754","article-title":"Fault-Tolerant Five-Leg Converter Topology with FPGA-Based Reconfigurable Control","volume":"60","author":"Shahbazi","year":"2013","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Khodabakhsh, J., and Moschopoulos, G. (2019, January 17\u201321). A Fault Tolerant Three-Phase Isolated AC-DC Converter. Proceedings of the 2019 IEEE Applied Power Electronics Conference and Exposition (APEC), Anaheim, CA, USA.","DOI":"10.1109\/APEC.2019.8722311"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"9226","DOI":"10.1109\/TPEL.2020.2974992","article-title":"A Single-Stage Fault-Tolerant Three-Phase Bidirectional AC\/DC Converter with Symmetric High-Frequency Y-\u0394 Connected Transformers","volume":"35","author":"Gu","year":"2020","journal-title":"IEEE Trans. Power Electron."},{"key":"ref_34","first-page":"4989","article-title":"Space-Vector-Based Hybrid PWM Strategy for Reduced DC-Link Capacitor Current Stress in the Postfault Grid-Connected Three-Phase Rectifier","volume":"63","author":"Zeng","year":"2016","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Jin, N., Zhao, C., and Guo, L. (2018, January 20\u201324). Model Predictive Fault Tolerant Control of Bidirectional AC\/DC Converter with Voltage Balance of Split Capacitor. Proceedings of the 2018 International Power Electronics Conference (IPEC-Niigata 2018-ECCE Asia), Niigata, Japan.","DOI":"10.23919\/IPEC.2018.8507868"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"819","DOI":"10.1109\/TIE.2017.2686342","article-title":"Finite States Model Predictive Control for Fault-Tolerant Operation of a Three-Phase Bidirectional AC\/DC Converter Under Unbalanced Grid Voltages","volume":"65","author":"Jin","year":"2018","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Guo, L., Zhang, K., Cao, L., Dai, L., Jin, N., and Li, Y. (2019, January 11\u201314). A Double-Voltage Vector Based Model Predictive Control Method for Three Phase Four-Switch Fault-Tolerant Converter. Proceedings of the 2019 22nd International Conference on Electrical Machines and Systems (ICEMS), Harbin, China.","DOI":"10.1109\/ICEMS.2019.8921843"},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Zhang, Z., Cai, K., and Kennel, R. (November, January 29). Current based open-circuit fault diagnosis and fault-tolerant control for two-level power converters with direct model predictive control. Proceedings of the IECON 2017\u201443rd Annual Conference of the IEEE Industrial Electronics Society, Beijing, China.","DOI":"10.1109\/IECON.2017.8216537"},{"key":"ref_39","doi-asserted-by":"crossref","unstructured":"Jin, N., Guo, L., and Yao, G. (2017). Model Predictive Direct Power Control for Nonredundant Fault Tolerant Grid-Connected Bidirectional Voltage Source Converter. Energies, 10.","DOI":"10.3390\/en10081133"},{"key":"ref_40","doi-asserted-by":"crossref","unstructured":"Li, Y., Li, G., Wu, Z., Hu, S., Jin, N., Guo, L., and Luo, K. (June, January 31). Multi-vector Model Predictive Direct Power Control for Fault-tolerant Bidirectional AC\/DC Converter. Proceedings of the 2019 IEEE International Symposium on Predictive Control of Electrical Drives and Power Electronics (PRECEDE), Quanzhou, China.","DOI":"10.1109\/PRECEDE.2019.8753316"},{"key":"ref_41","doi-asserted-by":"crossref","unstructured":"Jin, N., Guo, L., Zhao, C., Dou, Z., and Cui, G. (2018, January 4\u20138). Finite states model predictive direct power control for phase leg faults tolerant operation of bidirectional AC\/DC converter. Proceedings of the 2018 IEEE Applied Power Electronics Conference and Exposition (APEC), San Antonio, TX, USA.","DOI":"10.1109\/APEC.2018.8341341"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"1795","DOI":"10.1049\/el.2016.2713","article-title":"Current kernel density estimation based transistor open-circuit fault diagnosis in two-level three phase rectifier","volume":"52","author":"Tian","year":"2016","journal-title":"Electron. Lett."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"3935","DOI":"10.1109\/TPEL.2016.2587339","article-title":"Current Similarity Analysis-Based Open-Circuit Fault Diagnosis for Two-Level Three-Phase PWM Rectifier","volume":"32","author":"Wu","year":"2017","journal-title":"IEEE Trans. Power Electron."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"4681","DOI":"10.1109\/TIE.2009.2023640","article-title":"Open-transistor fault diagnostics in voltage-source inverters by analyzing the load current","volume":"56","author":"Sleszynski","year":"2009","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1109\/TIE.2011.2151818","article-title":"Improvement of Matrix Converter Drive Reliability by Online Fault Detection and a Fault-Tolerant Switching Strategy","volume":"59","author":"Liu","year":"2012","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"5953","DOI":"10.1109\/TIE.2016.2558139","article-title":"Open-Switch Fault Diagnosis and Fault Tolerant for Matrix Converter with Finite Control Set-Model Predictive Control","volume":"63","author":"Peng","year":"2016","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Tran, V. (2016, January 19\u201321). Short circuit fault tolerant system for Matrix Converter. Proceedings of the 8th IET International Conference on Power Electronics, Machines and Drives (PEMD 2016), Glasgow, UK.","DOI":"10.1049\/cp.2016.0373"},{"key":"ref_48","unstructured":"Kwak, S., and Kim, T. (2008, January 15\u201319). Design of matrix converter topology and modulation algorithms with shorted and opened failure tolerance. Proceedings of the 2008 IEEE Power Electronics Specialists Conference, Rhodes, Greece."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"855","DOI":"10.1109\/TEC.2006.888018","article-title":"An Approach to Fault-Tolerant Three-Phase Matrix Converter Drives","volume":"22","author":"Kwak","year":"2007","journal-title":"IEEE Trans. Energy Convers."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1109\/TIE.2011.2143378","article-title":"Four-Leg-Based Fault-Tolerant Matrix Converter Schemes Based on Switching Function and Space Vector Methods","volume":"59","author":"Kwak","year":"2012","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_51","doi-asserted-by":"crossref","unstructured":"Jung, J.H., Ku, H.K., Son, Y.D., and Kim, J.M. (2019). Open-Switch Fault Diagnosis Algorithm and Tolerant Control Method of the Three-Phase Three-Level NPC Active Rectifier. Energies, 12.","DOI":"10.3390\/en12132495"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"519","DOI":"10.1109\/TPEL.2011.2143430","article-title":"Analysis and Design of Active NPC (ANPC) Inverters for Fault-Tolerant Operation of High-Power Electrical Drives","volume":"27","author":"Li","year":"2012","journal-title":"IEEE Trans. Power Electron."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"1669","DOI":"10.1109\/TIE.2014.2341558","article-title":"Real-Time IGBT Open-Circuit Fault Diagnosis in Three-Level Neutral-Point-Clamped Voltage-Source Rectifiers Based on Instant Voltage Error","volume":"62","author":"Caseiro","year":"2015","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"26739","DOI":"10.1109\/ACCESS.2020.2970725","article-title":"Adaptive Carrier-Based PDPWM Control for Modular Multilevel Converter with Fault-Tolerant Capability","volume":"8","author":"Hashfi","year":"2020","journal-title":"IEEE Access"},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"2840","DOI":"10.1109\/TIA.2016.2608940","article-title":"An Integrated Control Strategy with Fault Detection and Tolerant Control Capability Based on Capacitor Voltage Estimation for Modular Multilevel Converters","volume":"53","author":"Abdelsalam","year":"2017","journal-title":"IEEE Trans. Ind. Appl."},{"key":"ref_56","doi-asserted-by":"crossref","unstructured":"Wang, S., Teodorescu, R., and Chaudhary, S.K. (2018, January 4\u20137). Capacitor Voltage Ripple Reduction Methods of Modular Multilevel Converter under Unbalanced Fault Conditions: A Comparison. Proceedings of the 2018 IEEE International Power Electronics and Application Conference and Exposition (PEAC), Shenzhen, China.","DOI":"10.1109\/PEAC.2018.8590514"},{"key":"ref_57","doi-asserted-by":"crossref","unstructured":"Ruffing, P., Petino, C., and Schnettler, A. (2017, January 14\u201316). Dynamic internal overcurrent control for undetected DC faults for modular multilevel converters. Proceedings of the 13th IET International Conference on AC and DC Power Transmission (ACDC 2017), Manchester, UK.","DOI":"10.1049\/cp.2017.0070"},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"872","DOI":"10.1109\/JESTPE.2020.2974570","article-title":"A General Fault-Tolerant Operation Strategy Under Switch Fault for Modular Series\u2013Parallel DC\u2013DC Converter","volume":"9","author":"Wang","year":"2021","journal-title":"IEEE J. Emerg. Sel. Top. Power Electron."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1109\/63.491644","article-title":"Regulation of a PWM rectifier in the unbalanced network state using a generalized model","volume":"11","author":"Rioual","year":"1996","journal-title":"IEEE Trans. Power Electron."},{"key":"ref_60","doi-asserted-by":"crossref","unstructured":"Gong, Z., Khan Jadoon, H.U., Huang, D., Qin, N., and Ma, L. (2019, January 5\u20137). Fault Diagnosis and Tolerant Control for Sensors of PWM Rectifier Under High Switching Frequency. Proceedings of the 2019 CAA Symposium on Fault Detection, Supervision and Safety for Technical Processes (SAFEPROCESS), Xiamen, China.","DOI":"10.1109\/SAFEPROCESS45799.2019.9213426"},{"key":"ref_61","first-page":"384","article-title":"Fault Diagnosis Method of Voltage Sensor in 3-phase AC\/DC PWM Converters","volume":"1","author":"Kim","year":"2012","journal-title":"J. Int. Conf. Electr. Mach. Syst."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"695","DOI":"10.6113\/JPE.2014.14.4.695","article-title":"Fault tolerant control of DC-link voltage sensor for three-phase AC\/DC\/AC PWM converters","volume":"14","author":"Kim","year":"2014","journal-title":"J. Power Electron."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"48175","DOI":"10.1109\/ACCESS.2019.2908428","article-title":"Tolerant Control of Voltage Signal Fault for Converter Station Based Multi-Terminal HVDC Systems","volume":"7","author":"Wang","year":"2019","journal-title":"IEEE Access"},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"2809","DOI":"10.1109\/TSG.2016.2620803","article-title":"Fault-Tolerant Supervisory Controller for a Hybrid AC\/DC Micro-Grid","volume":"9","author":"Hosseinzadeh","year":"2018","journal-title":"IEEE Trans. Smart Grid"},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"5842","DOI":"10.1109\/TPEL.2013.2257862","article-title":"State Observer-Based Sensor Fault Detection and Isolation, and Fault Tolerant Control of a Single-Phase PWM Rectifier for Electric Railway Traction","volume":"28","author":"Youssef","year":"2013","journal-title":"IEEE Trans. Power Electron."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"1662","DOI":"10.1109\/TIE.2010.2055775","article-title":"Detection and Isolation of Speed-, DC-Link Voltage-, and Current-Sensor Faults Based on an Adaptive Observer in Induction-Motor Drives","volume":"58","author":"Najafabadi","year":"2011","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"825","DOI":"10.1109\/TIA.2006.873673","article-title":"Control scheme in hybrid synchronous stationary frame for PWM AC\/DC converter under generalized unbalanced operating conditions","volume":"42","author":"Suh","year":"2006","journal-title":"IEEE Trans. Ind. Appl."},{"key":"ref_68","doi-asserted-by":"crossref","unstructured":"Feng, D., Chen, Z., Jiang, Z., Yan, L., Qian, N., and Zong, X. (2020, January 12\u201314). Analysis and Treatment of Three-Phase Unbalance Problem. Proceedings of the 2020 IEEE 4th Information Technology, Networking, Electronic and Automation Control Conference (ITNEC), Chongqing, China.","DOI":"10.1109\/ITNEC48623.2020.9084963"},{"key":"ref_69","unstructured":"Lin, C., Chen, C., and Huang, C. (1992, January 13). Calculating approach and implementation for active filters in unbalanced three-phase system using synchronous detection method. Proceedings of the 1992 International Conference on Industrial Electronics, Control, Instrumentation, and Automation, San Diego, CA, USA."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"2521","DOI":"10.1109\/TPEL.2010.2049030","article-title":"Control of Three-Phase Boost-Type PWM Rectifier in Stationary Frame Under Unbalanced Input Voltage","volume":"25","author":"Li","year":"2010","journal-title":"IEEE Trans. Power Electron."},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"5892","DOI":"10.1109\/TPEL.2014.2371469","article-title":"Direct Power Control of a Pulse Width Modulation Rectifier Using Space Vector Modulation Under Unbalanced Grid Voltages","volume":"30","author":"Zhang","year":"2015","journal-title":"IEEE Trans. Power Electron."},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"6850","DOI":"10.1109\/TIE.2018.2798583","article-title":"Multivector Model Predictive Power Control of Three-Phase Rectifiers with Reduced Power Ripples Under Nonideal Grid Conditions","volume":"65","author":"Zhou","year":"2018","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_73","doi-asserted-by":"crossref","unstructured":"Roiu, D., Bojoi, R., Limongi, L.R., and Tenconi, A. (2008, January 5\u20139). New Stationary Frame Control Scheme for Three Phase PWM Rectifiers under Unbalanced Voltage Dips Conditions. Proceedings of the 2008 IEEE Industry Applications Society Annual Meeting, Edmonton, AB, Canada.","DOI":"10.1109\/08IAS.2008.320"},{"key":"ref_74","doi-asserted-by":"crossref","first-page":"e12389","DOI":"10.1002\/2050-7038.12389","article-title":"Three-phase converter power control under grid imbalance with consideration of instantaneous power components limitation","volume":"30","author":"Wodyk","year":"2020","journal-title":"Int. Trans. Electr. Energy Syst."},{"key":"ref_75","doi-asserted-by":"crossref","unstructured":"Jin, N., Pan, C., Li, Y., Hu, S., and Fang, J. (2020). Model Predictive Control for Virtual Synchronous Generator with Improved Vector Selection and Reconstructed Current. Energies, 13.","DOI":"10.3390\/en13205435"},{"key":"ref_76","doi-asserted-by":"crossref","first-page":"765","DOI":"10.1049\/ip-epa:20045099","article-title":"Time and frequency domain analysis of fault-tolerant space vector PWM VSI-fed induction motor drive","volume":"152","author":"Klima","year":"2005","journal-title":"IEE Proc.-Electr. Power Appl."},{"key":"ref_77","doi-asserted-by":"crossref","unstructured":"Valouch, V., \u0160imek, P., and \u0160kraml\u00edk, J. (2018, January 16\u201318). Experimental investigation of fault tolerant converter connected to unbalanced grid. Proceedings of the 2018 19th International Scientific Conference on Electric Power Engineering (EPE), Brno, Czech Republic.","DOI":"10.1109\/EPE.2018.8395992"},{"key":"ref_78","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1109\/TPWRD.2015.2435796","article-title":"DC Voltage Compensation Strategy for Parallel Hybrid Multilevel Voltage-Source Converter","volume":"31","author":"Yang","year":"2016","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_79","doi-asserted-by":"crossref","unstructured":"Amankwah, E., Watson, A., Feldman, R., Clare, J., and Wheeler, P. (2013, January 17\u201321). Experimental validation of a parallel hybrid modular multilevel voltage source converter for HVDC transmission. Proceedings of the 2013 Twenty-Eighth Annual IEEE Applied Power Electronics Conference and Exposition (APEC), Long Beach, CA, USA.","DOI":"10.1109\/APEC.2013.6520512"},{"key":"ref_80","doi-asserted-by":"crossref","unstructured":"Patro, S.K., Ghat, M.B., and Shukla, A. (2018, January 23\u201327). DC Fault Tolerant Modified Parallel Hybrid Converter with Enhanced Operating Range. Proceedings of the 2018 IEEE Energy Conversion Congress and Exposition (ECCE), Portland, OR, USA.","DOI":"10.1109\/ECCE.2018.8558227"},{"key":"ref_81","doi-asserted-by":"crossref","unstructured":"Park, J.W., Jung, J.H., Kim, J.M., and Son, Y.D. (2017, January 3\u20137). Fault tolerant control of three phase 2-parallel AC\/DC PWM converter systems. Proceedings of the 2017 IEEE 3rd International Future Energy Electronics Conference and ECCE Asia (IFEEC 2017\u2014ECCE Asia), Kaohsiung, Taiwan.","DOI":"10.1109\/IFEEC.2017.7992150"},{"key":"ref_82","doi-asserted-by":"crossref","unstructured":"Wei, L., Hang, W., Gen, C., Wen, Z.J., and Xu, C. (2020, January 6\u20139). Optimal Fault-tolerant Control for Improving the Availability of Parallel Wind Power Converters. Proceedings of the 2020 4th International Conference on HVDC (HVDC), Xi\u2019an, China.","DOI":"10.1109\/HVDC50696.2020.9292818"},{"key":"ref_83","doi-asserted-by":"crossref","unstructured":"Singh, R.K., and Mishra, S. (2012, January 16\u201319). A digital optimal battery charger with the inbuilt fault detection property. Proceedings of the 2012 IEEE International Conference on Power Electronics, Drives and Energy Systems (PEDES), Bengaluru, India.","DOI":"10.1109\/PEDES.2012.6484353"},{"key":"ref_84","doi-asserted-by":"crossref","first-page":"12122","DOI":"10.1109\/TPEL.2020.2986798","article-title":"A Three-Phase Integrated Battery Charger for EVs Based on Six-Phase Open-End Winding Machine","volume":"35","author":"Raherimihaja","year":"2020","journal-title":"IEEE Trans. Power Electron."},{"key":"ref_85","doi-asserted-by":"crossref","unstructured":"Viana, C., Keshani, M., and Lehn, P.W. (2019, January 17\u201320). Interleaved Buck-Boost Integrated DC Fast Charger with Bidirectional Fault Blocking Capability. Proceedings of the 2019 20th Workshop on Control and Modeling for Power Electronics (COMPEL), Toronto, ON, Canada.","DOI":"10.1109\/COMPEL.2019.8769656"},{"key":"ref_86","doi-asserted-by":"crossref","unstructured":"Zhang, Y., Li, T., Yan, X., Wang, L., Zhang, J., Diao, X., and Li, B. (2021). Electric Vehicle Charging Fault Monitoring and Warning Method Based on Battery Model. World Electr. Veh. J., 12.","DOI":"10.3390\/wevj12010014"},{"key":"ref_87","doi-asserted-by":"crossref","unstructured":"Abdel-Majeed, M.S., Shawier, A., Abdel-Khalik, A.S., Hamad, M.S., Sedky, M.M., and Elmalhy, N.A. (2022). General Current Control of Six-Phase-Based Non-Isolated Integrated On-Board Charger with Low Order Harmonic Compensation. Sustainability, 14.","DOI":"10.3390\/su14031088"},{"key":"ref_88","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1109\/TSG.2014.2360685","article-title":"Single-Phase On-Board Bidirectional PEV Charger for V2G Reactive Power Operation","volume":"6","author":"Kisacikoglu","year":"2015","journal-title":"IEEE Trans. Smart Grid"}],"container-title":["Electronics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2079-9292\/11\/7\/1107\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T22:47:28Z","timestamp":1760136448000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2079-9292\/11\/7\/1107"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3,31]]},"references-count":88,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2022,4]]}},"alternative-id":["electronics11071107"],"URL":"https:\/\/doi.org\/10.3390\/electronics11071107","relation":{},"ISSN":["2079-9292"],"issn-type":[{"value":"2079-9292","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,3,31]]}}}