{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T09:26:19Z","timestamp":1787217979987,"version":"build-2736575974"},"reference-count":30,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T00:00:00Z","timestamp":1787184000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100002850","name":"FONDECYT Regular","doi-asserted-by":"publisher","award":["1251313"],"award-info":[{"award-number":["1251313"]}],"id":[{"id":"10.13039\/501100002850","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Gels"],"abstract":"<jats:p>Gadolinium-doped polymer gel dosimeters enable experimental evaluation of dose enhancement in low-energy radiotherapy, although the high Gd concentrations required substantially alter their magnetic relaxation properties, making the optimal Magnetic Resonance Imaging (MRI) readout uncertain. This study characterized the dosimetric response of PAGAT and Gd-PAGAT (9 mg\/mL Gd) irradiated with a 150 kVp X-ray beam from 1 to 10 Gy using quantitative 1.5 T MRI. Quantitative R1 and R2 maps were obtained from variable flip-angle spoiled gradient echo (SPGR) and multi-echo spin echo (MSE) sequences, respectively, and validated by UV-Vis spectrophotometry. R1 showed no significant dose dependence in Gd-PAGAT because of severe T1 shortening. In contrast, R2 exhibited a robust response, with second-order polynomial fits (R2 = 0.9984 for PAGAT and 0.9969 for Gd-PAGAT) and linear behavior between 1 and 7 Gy. The dose sensitivity of Gd-PAGAT was 2.84 \u00b1 0.19 times higher than that of PAGAT (0.5328 vs. 0.1949 s\u22121\u00b7Gy\u22121). Spectrophotometry confirmed the PAGAT calibration but showed markedly lower sensitivity for Gd-PAGAT, particularly at low doses. These findings demonstrate that R2 mapping overcomes the limitations imposed by extreme T1 shortening, extending the applicability of Gd-PAGAT dosimeters for three-dimensional dose enhancement studies in low-energy radiotherapy.<\/jats:p>","DOI":"10.3390\/gels12080745","type":"journal-article","created":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T08:10:20Z","timestamp":1787213420000},"page":"745","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Dosimetric Characterization Using Quantitative Magnetic Resonance Imaging of PAGAT and Gd-PAGAT Polymer Gel Dosimeters at High Gd Concentration"],"prefix":"10.3390","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0009-0005-8048-8521","authenticated-orcid":false,"given":"Melani","family":"Fuentealba","sequence":"first","affiliation":[{"name":"Departamento de Cs. F\u00edsicas, Universidad de La Frontera, Temuco 4811230, Chile"},{"name":"Laboratorio de Metrolog\u00eda de Radiaciones Ionizantes, Universidad de La Frontera, Temuco 4811230, Chile"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gerardo","family":"Belmar","sequence":"additional","affiliation":[{"name":"Departamento de Tecnolog\u00eda M\u00e9dica, Universidad de Concepci\u00f3n, Concepci\u00f3n 4070386, Chile"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mauricio","family":"Santib\u00e1\u00f1ez","sequence":"additional","affiliation":[{"name":"Departamento de Cs. F\u00edsicas, Universidad de La Frontera, Temuco 4811230, Chile"},{"name":"Laboratorio de Metrolog\u00eda de Radiaciones Ionizantes, Universidad de La Frontera, Temuco 4811230, Chile"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,8,20]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"De Deene, Y. (2022). Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D. Gels, 8.","DOI":"10.3390\/gels8090599"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Sagsoz, M.E., Korkut, O., and Gallo, S. (2025). Advancements in Tissue-Equivalent Gel Dosimeters. Gels, 11.","DOI":"10.3390\/gels11020081"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"3875","DOI":"10.1088\/0031-9155\/50\/16\/015","article-title":"Investigation of the PAGAT Polymer Gel Dosimeter Using Magnetic Resonance Imaging","volume":"50","author":"Venning","year":"2005","journal-title":"Phys. Med. Biol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"012033","DOI":"10.1088\/1742-6596\/164\/1\/012033","article-title":"Review of Quantitative MRI Principles for Gel Dosimetry","volume":"164","author":"Deene","year":"2009","journal-title":"J. Phys. Conf. Ser."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Khan, M., Heilemann, G., Lechner, W., Georg, D., and Berg, A.G. (2019). Basic Properties of a New Polymer Gel for 3D-Dosimetry at High Dose-Rates Typical for FFF Irradiation Based on Dithiothreitol and Methacrylic Acid (MAGADIT): Sensitivity, Range, Reproducibility, Accuracy, Dose Rate Effect and Impact of Oxygen Scavenger. Polymers, 11.","DOI":"10.3390\/polym11101717"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"012014","DOI":"10.1088\/1742-6596\/2630\/1\/012014","article-title":"Optimization of MRI Pulse Sequences and Gadobutrol-Doped Polymer Gel for Real Time 4D Radiation Dosimetry on the MRI-Linac","volume":"2630","author":"Deene","year":"2023","journal-title":"J. Phys. Conf. Ser."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"3301","DOI":"10.1088\/0031-9155\/51\/14\/001","article-title":"Polymer Gel Dosimeters with Reduced Toxicity: A Preliminary Investigation of the NMR and Optical Dose\u2013Response Using Different Monomers","volume":"51","author":"Senden","year":"2006","journal-title":"Phys. Med. Biol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1016\/j.rpor.2012.03.009","article-title":"Optical and NMR Dose Response of N-Isopropylacrylamide Normoxic Polymer Gel for Radiation Therapy Dosimetry","volume":"17","author":"Mesbahi","year":"2012","journal-title":"Rep. Pract. Oncol. Radiother."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/j.nimb.2017.09.033","article-title":"Comparative Study of Nuclear Magnetic Resonance and UV\u2013Visible Spectroscopy Dose-Response of Polymer Gel Based on N-(Isobutoxymethyl) Acrylamide","volume":"413","author":"Lotfy","year":"2017","journal-title":"Nucl. Instrum. Methods Phys. Res. Sect. B Beam Interact. Mater. At."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"012010","DOI":"10.1088\/1757-899X\/1347\/1\/012010","article-title":"A Review Study on Gel Dosimeter Added with Metal-Based Nanoparticles and Its Applications","volume":"1347","author":"Yoshandi","year":"2026","journal-title":"IOP Conf. Ser. Mater. Sci. Eng."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Zhang, D.G., Feygelman, V., Moros, E.G., Latifi, K., and Zhang, G.G. (2014). Monte Carlo Study of Radiation Dose Enhancement by Gadolinium in Megavoltage and High Dose Rate Radiotherapy. PLoS ONE, 9.","DOI":"10.1371\/journal.pone.0109389"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"109533","DOI":"10.1016\/j.radphyschem.2021.109533","article-title":"Experimental Characterization and Monte Carlo Simulations of the Dose Enhancement on the Millimeter Scale of PAGAT Infused with Gadolinium","volume":"186","author":"Fuentealba","year":"2021","journal-title":"Radiat. Phys. Chem."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"4449","DOI":"10.1088\/0031-9155\/60\/11\/4449","article-title":"Gadolinium Nanoparticles and Contrast Agent as Radiation Sensitizers","volume":"60","author":"Taupin","year":"2015","journal-title":"Phys. Med. Biol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"2293","DOI":"10.1021\/cr980440x","article-title":"Gadolinium(III) Chelates as MRI Contrast Agents: Structure, Dynamics, and Applications","volume":"99","author":"Caravan","year":"1999","journal-title":"Chem. Rev."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1007\/s10534-016-9931-7","article-title":"Gadolinium-Based Contrast Agent Toxicity: A Review of Known and Proposed Mechanisms","volume":"29","author":"Rogosnitzky","year":"2016","journal-title":"BioMetals"},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Fuentealba, M., Vallejos, C., D\u00edez, S., and Santib\u00e1\u00f1ez, M. (2025). Dosimetric Evaluation of the Sensitivity of PAGAT Gel Dosimeters Infused with Clinically Used Gadolinium-Based Contrast Agents. Gels, 11.","DOI":"10.3390\/gels11060416"},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Fuentealba, M., Ferreira, A., Salgado, A., Vergara, C., D\u00edez, S., and Santib\u00e1\u00f1ez, M. (2024). An Optimized Method for Evaluating the Potential Gd-Nanoparticle Dose Enhancement Produced by Electronic Brachytherapy. Nanomaterials, 14.","DOI":"10.3390\/nano14050430"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"5949","DOI":"10.1002\/mp.12570","article-title":"Comparison of Gadolinium Nanoparticles and Molecular Contrast Agents for Radiation Therapy-Enhancement","volume":"44","author":"Delorme","year":"2017","journal-title":"Med. Phys."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Sabbaghizadeh, R., Shamsudin, R., Deyhimihaghighi, N., and Sedghi, A. (2017). Enhancement of Dose Response and Nuclear Magnetic Resonance Image of PAGAT Polymer Gel Dosimeter by Adding Silver Nanoparticles. PLoS ONE, 12.","DOI":"10.1371\/journal.pone.0168737"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"108739","DOI":"10.1016\/j.radphyschem.2020.108739","article-title":"The Dose Enhancement of MAGAT Gel Dosimeter Doped with Zinc Oxide at 6 MV Photon Beam","volume":"172","author":"Mustaqim","year":"2020","journal-title":"Radiat. Phys. Chem."},{"key":"ref_21","first-page":"27","article-title":"Lesion enhancement in radio-frequency spoiled gradient-echo imaging: Theory, experimental evaluation, and clinical implications","volume":"15","author":"Rand","year":"1994","journal-title":"Am. J. Neuroradiol."},{"key":"ref_22","first-page":"815729","article-title":"Parameter Optimization for Quantitative Signal-Concentration Mapping Using Spoiled Gradient Echo MRI","volume":"2012","author":"Hathout","year":"2012","journal-title":"Radiol. Res. Pract."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"112322","DOI":"10.1016\/j.ejrad.2025.112322","article-title":"Gadolinium Concentration Dependent Signal Enhancement Profiles Using Routine Clinical Sequences with Gadopiclenol, Gadoterate, Gadobutrol, and Gadoxetate at 1.5, 3 and 7 Tesla","volume":"191","author":"Marth","year":"2025","journal-title":"Eur. J. Radiol."},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Macchione, M.A., Lech\u00f3n P\u00e1ez, S., Strumia, M.C., Valente, M., and Mattea, F. (2022). Chemical Overview of Gel Dosimetry Systems: A Comprehensive Review. Gels, 8.","DOI":"10.3390\/gels8100663"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"2705","DOI":"10.1088\/0031-9155\/41\/12\/010","article-title":"Radiation Dose Distributions in Three Dimensions from Tomographic Optical Density Scanning of Polymer Gels: II. Optical Properties of the BANG Polymer Gel","volume":"41","author":"Zastavker","year":"1996","journal-title":"Phys. Med. Biol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"R1","DOI":"10.1088\/0031-9155\/55\/5\/R01","article-title":"Polymer Gel Dosimetry","volume":"55","author":"Baldock","year":"2010","journal-title":"Phys. Med. Biol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1088\/0031-9155\/46\/2\/312","article-title":"Dose resolution in radiotherapy polymer gel dosimetry: Effect of echo spacing in MRI pulse sequence","volume":"46","author":"Baldock","year":"2001","journal-title":"Phys. Med. Biol."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/S0165-1684(98)00115-7","article-title":"Mathematical Analysis and Experimental Investigation of Noise in Quantitative Magnetic Resonance Imaging Applied in Polymer Gel Dosimetry","volume":"70","author":"Deene","year":"1998","journal-title":"Signal Process."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1088\/1742-6596\/3\/1\/016","article-title":"Preliminary Study of a Normoxic PAG Gel Dosimeter with Tetrakis (Hydroxymethyl) Phosphonium Chloride as an Anti-Oxidant","volume":"3","author":"Venning","year":"2004","journal-title":"J. Phys. Conf. Ser."},{"key":"ref_30","unstructured":"IAEA (2024). Absorbed Dose Determination in External Beam Radiotherapy, International Atomic Energy Agency. Technical Reports Series; Rev. 1."}],"container-title":["Gels"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2310-2861\/12\/8\/745\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T08:56:00Z","timestamp":1787216160000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2310-2861\/12\/8\/745"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,20]]},"references-count":30,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2026,8]]}},"alternative-id":["gels12080745"],"URL":"https:\/\/doi.org\/10.3390\/gels12080745","relation":{},"ISSN":["2310-2861"],"issn-type":[{"value":"2310-2861","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,20]]}}}