{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,31]],"date-time":"2026-10-31T12:44:36Z","timestamp":1793450676435,"version":"4.5.0"},"reference-count":27,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2021,5,29]],"date-time":"2021-05-29T00:00:00Z","timestamp":1622246400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Healthcare"],"abstract":"<jats:p>Anemia is a condition in which red blood cells are not able to carry adequate oxygen to the body\u2019s tissues, and is widely found in nearly a quarter of the world population. The typical method to screen for the iron-deficiency anemia, which is the major anemia found in the world, is to implement a blood test called a complete blood count (CBC). However, even though this test gives a highly accurate result, it requires an invasive blood drawing and lab analyzing which could potentially cause physical pain, high risk of infection and take a long time to analyze. Therefore, this research presents an alternative method using an optical technique to measure hemoglobin concentration, which is the common indicator for diagnosing anemia. The light absorbance of the oxyhemoglobin at the wavelength of 660 nm and the deoxyhemoglobin at the wavelength of 880 nm were measured using the MAX30100 sensor. These wavelengths of light are obtained from red and infrared (IR) LEDs. The concept is based on the different absorption coefficients of blood at different electromagnetic wavelengths. This fact is used to indirectly calculate the hemoglobin concentration of blood through the modified Beer\u2013Lambert law. Moreover, the result has been further converted to absolute hemoglobin concentration using a calibration curve derived from the cyanmethemoglobin test, which is the regular method for hemoglobin determination. Besides, the android application was also provided which can wirelessly record or monitor the data. The experiment shows that an accuracy of 90.9% can be achieved by our proposed noninvasive method. Therefore, the noninvasive portable hemoglobin concentration monitoring by the optical sensor has an acceptable result when compared with the invasive method, with less pain and lower risk of infection, as well as shorter processing time.<\/jats:p>","DOI":"10.3390\/healthcare9060647","type":"journal-article","created":{"date-parts":[[2021,5,31]],"date-time":"2021-05-31T00:22:15Z","timestamp":1622420535000},"page":"647","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":19,"title":["Noninvasive Portable Hemoglobin Concentration Monitoring System Using Optical Sensor for Anemia Disease"],"prefix":"10.3390","volume":"9","author":[{"given":"Chuchart","family":"Pintavirooj","sequence":"first","affiliation":[{"name":"School of Engineering, King Mongkut Institute of Technology Ladkrabang, Bangkok 10520, Thailand"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Baorong","family":"Ni","sequence":"additional","affiliation":[{"name":"Faculty of Engineering, Fukuoka Institute of Technology, Fukuoka 811-0295, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chaiwat","family":"Chatkobkool","sequence":"additional","affiliation":[{"name":"School of Engineering, King Mongkut Institute of Technology Ladkrabang, Bangkok 10520, Thailand"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kittitorn","family":"Pinijkij","sequence":"additional","affiliation":[{"name":"School of Engineering, King Mongkut Institute of Technology Ladkrabang, Bangkok 10520, Thailand"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2021,5,29]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"290","DOI":"10.1007\/BF01617328","article-title":"Pulse oximetry: Analysis of theory, technology, and practice","volume":"4","author":"Wukitsch","year":"1988","journal-title":"J. Clin. Monit."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1080\/08998280.2006.11928171","article-title":"Structure-function relations of human hemoglobin\u2019s","volume":"19","year":"2006","journal-title":"Bayl. Univ. Med. Cent. Proc."},{"key":"ref_3","unstructured":"World Health Organization (2001). Iron Deficiency Anemia: Assessment, Prevention and Control a Guide for Program Managers, World Health Organization. who reference who\/nhd\/01.3."},{"key":"ref_4","unstructured":"de benoist, B., Mclean, E., Egli, I., Cogswell, M., and World Health Organization (2008). Worldwide Prevalence of Anemia 1993\u20132005: WHO Global Database on Anemia, World Health Organization."},{"key":"ref_5","first-page":"506","article-title":"Estimating the prevalence of anemia: A comparison of three methods","volume":"79","author":"Sari","year":"2001","journal-title":"Bull. World Health Org."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"23","DOI":"10.7196\/SAMJ.2017.v107i1.12148","article-title":"Anemia: Approach to diagnosis","volume":"107","author":"Alli","year":"2017","journal-title":"SAMJ S. Afr. Med. J."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1243","DOI":"10.1093\/ajcn\/69.6.1243","article-title":"Precision, accuracy, and reliability of hemoglobin assessment with use of capillary blood","volume":"69","author":"Morris","year":"1999","journal-title":"Am. J. Clin. Nutr."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"A011866","DOI":"10.1101\/cshperspect.a011866","article-title":"Iron deficiency anemia: A common and curable disease","volume":"3","author":"Miller","year":"2013","journal-title":"Cold Spring Harb. Perspect. Med."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Timm, U., Lewis, E., Leen, G., Krait, J., and Ewald, H. (2009). Non-Invasive Continuous Online Hemoglobin Monitoring System, IEEE.","DOI":"10.1109\/SAS.2010.5439415"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Al-baradie, R.S., and Bose, S.C. (2013, January 18\u201321). Portable smart non-invasive hemoglobin measurement system. Proceedings of the 10th International Multi-Conferences on Systems, Signals & Devices 2013 (SSD13), Hammamet, Tunisia.","DOI":"10.1109\/SSD.2013.6564149"},{"key":"ref_11","unstructured":"Kraitl, J., Ewald, H., and Timm, U. (December, January 28). Non-invasive measurement of blood components. Proceedings of the IEEE Fifth International Conference on Sensing Technology, Palmerston North, New Zealand."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1114\/1.1527046","article-title":"Length-normalized pulse photoplethysmography: A noninvasive method to measure blood hemoglobin","volume":"30","author":"Aldrich","year":"2002","journal-title":"Ann. Biomed. Eng."},{"key":"ref_13","first-page":"41","article-title":"Optical sensor system for hemoglobin measurement","volume":"3","author":"Rajashree","year":"2013","journal-title":"IJCER"},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Rochmanto, R.A., Zakaria, H., Alviana, R.D., and Shahib, N. (2017, January 19\u201321). Non-invasive hemoglobin measurement for anemia diagnosis. Proceedings of the 2017 4th International Conference on Electrical Engineering, Computer Science and Informatics (EECSI), Yogyakarta, Indonesia.","DOI":"10.1109\/EECSI.2017.8239096"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Chugh, S., and Kaur, J. (2015, January 19\u201321). Non-invasive hemoglobin monitoring device. Proceedings of the 2015 International Conference on Control, Communication & Computing India (ICCC), Trivandrum, India.","DOI":"10.1109\/ICCC.2015.7432925"},{"key":"ref_16","unstructured":"Rene, A.J. (2007). Principles and Applications of Fluorescence Spectroscopy, Blackwell Publishing."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"N91","DOI":"10.1088\/0031-9155\/51\/5\/N02","article-title":"The modified beer\u2013lambert law revisited","volume":"51","author":"Kocsis","year":"2006","journal-title":"Phys. Med. Biol."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"105004","DOI":"10.1117\/1.JBO.18.10.105004","article-title":"General equation for the differential pathlength factor of the frontal human head depending on wavelength and age","volume":"18","author":"Scholkmann","year":"2013","journal-title":"J. Biomed. Opt."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"012061","DOI":"10.1088\/1742-6596\/238\/1\/012061","article-title":"Beer-lambert law along non-linear mean light pathways for the rational analysis of photoplethysmography","volume":"238","author":"Rybynok","year":"2010","journal-title":"J. Phys. Conf. Ser."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1186\/s13054-015-0984-8","article-title":"Pulse oximetry","volume":"19","author":"Jubran","year":"2015","journal-title":"Crit. Care"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1016\/j.rmed.2013.02.004","article-title":"Pulse oximetry: Understanding its basic principles facilitates appreciation of its limitations","volume":"107","author":"Chan","year":"2013","journal-title":"Respir. Med."},{"key":"ref_22","unstructured":"Strogonovs, R. (2021, May 12). Implementing Pulse Oximeter Using MAX30100, Morf-Coding and Engineering. Available online: https:\/\/morf.lv\/implementing-pulse-oximeter-using-max30100."},{"key":"ref_23","first-page":"7","article-title":"Generalized Beer\u2013Lambert model for near-infrared light propagation in thick biological tissues","volume":"21","author":"Manish","year":"2016","journal-title":"J. Biomed. Opt."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"075005","DOI":"10.1117\/1.JBO.23.7.075005","article-title":"Investigating optical path and differential pathlength factor in reflectance photoplethysmography for the assessment of perfusion","volume":"23","author":"Chatterjee","year":"2018","journal-title":"J. Biomed. Opt."},{"key":"ref_25","unstructured":"(2021, May 12). Tabulated Molar Extinction Coefficient for Hemoglobin in Water. Available online: https:\/\/omlc.org\/spectra\/hemoglobin\/summary.html."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1007\/BF02722739","article-title":"Validation of hemoglobin estimation using Hemocue","volume":"70","author":"Bhaskaram","year":"2003","journal-title":"Indian J. Pediatr."},{"key":"ref_27","first-page":"1616","article-title":"Chemotherapy-Induced Anemia in Adults: Incidence and Treatment","volume":"19","author":"Jerome","year":"1999","journal-title":"J. Natl. Cancer Inst."}],"container-title":["Healthcare"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2227-9032\/9\/6\/647\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T06:08:54Z","timestamp":1760162934000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2227-9032\/9\/6\/647"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,5,29]]},"references-count":27,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2021,6]]}},"alternative-id":["healthcare9060647"],"URL":"https:\/\/doi.org\/10.3390\/healthcare9060647","relation":{},"ISSN":["2227-9032"],"issn-type":[{"value":"2227-9032","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,5,29]]}}}