{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T15:59:25Z","timestamp":1792166365665,"version":"4.4.0"},"reference-count":43,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2018,11,30]],"date-time":"2018-11-30T00:00:00Z","timestamp":1543536000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Master Program \u2018Applied and Environmental Health\u2019 of the Medical Faculty of the University of Thessaly, Greece.","award":["Not applicable"],"award-info":[{"award-number":["Not applicable"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IJERPH"],"abstract":"<jats:p>This study aimed to assess the colonization of hotel water systems in central Greece and Corfu by Legionella, and to investigate the association between physicochemical parameters and Legionella colonization. Standardized hygiene inspection was conducted in 51 hotels, and 556 water samples were analyzed for Legionella spp. Free chlorine concentration, pH, hardness, conductivity, and trace metals were defined in cold water samples. The results of inspections and chemical analyses were associated with the microbiological results using univariate and logistic regression analysis. According to the score of the checklist used for the inspections, 17.6% of the hotels were classified as satisfactory, 15.7% as adequate, and 66.7% as unsatisfactory. Moreover, 74.5% of the hotels were colonized by Legionella spp. and 31.4% required remedial measures according to the European guidelines. Legionella spp. were isolated in 28% of the samples. Unsatisfactory results of inspections were associated with Legionella presence (relative risk (RR) = 7.67, p-value = 0.043). In hot-water systems, &lt;50 \u00b0C temperatures increased the risk of Legionella colonization (RR = 5.36, p-value &lt; 0.001). In cold-water systems, free chlorine concentration &lt;0.375 mg\/L (odds ratio (OR) = 9.76, p-value = 0.001), pH \u2265 7.45 (OR = 4.05, p-value = 0.007), and hardness \u2265321 mgCaCO3\/L (OR = 5.63, p-value = 0.003) increased the risk, whereas copper pipes demonstrated a protective role (OR = 0.29, p-value = 0.0024). The majority of the hotels inspected were colonized with Legionella. Supplementary monitoring of the risk factors that were identified should be considered.<\/jats:p>","DOI":"10.3390\/ijerph15122707","type":"journal-article","created":{"date-parts":[[2018,11,30]],"date-time":"2018-11-30T12:13:17Z","timestamp":1543579997000},"page":"2707","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":34,"title":["Legionella Colonization of Hotel Water Systems in Touristic Places of Greece: Association with System Characteristics and Physicochemical Parameters"],"prefix":"10.3390","volume":"15","author":[{"given":"Maria A.","family":"Kyritsi","sequence":"first","affiliation":[{"name":"Department of Hygiene and Epidemiology, Medical School, University of Thessaly, 41222 Larissa, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2535-3596","authenticated-orcid":false,"given":"Varvara A.","family":"Mouchtouri","sequence":"additional","affiliation":[{"name":"Department of Hygiene and Epidemiology, Medical School, University of Thessaly, 41222 Larissa, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonis","family":"Katsioulis","sequence":"additional","affiliation":[{"name":"Department of Hygiene and Epidemiology, Medical School, University of Thessaly, 41222 Larissa, Greece"},{"name":"Regional Public Health Laboratory of Thessaly, 41222 Larissa, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7135-6555","authenticated-orcid":false,"given":"Elina","family":"Kostara","sequence":"additional","affiliation":[{"name":"Department of Hygiene and Epidemiology, Medical School, University of Thessaly, 41222 Larissa, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vasileios","family":"Nakoulas","sequence":"additional","affiliation":[{"name":"Department of Hygiene and Epidemiology, Medical School, University of Thessaly, 41222 Larissa, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marina","family":"Hatzinikou","sequence":"additional","affiliation":[{"name":"Department of Hygiene and Epidemiology, Medical School, University of Thessaly, 41222 Larissa, Greece"},{"name":"Regional Public Health Laboratory of Thessaly, 41222 Larissa, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christos","family":"Hadjichristodoulou","sequence":"additional","affiliation":[{"name":"Department of Hygiene and Epidemiology, Medical School, University of Thessaly, 41222 Larissa, Greece"},{"name":"Regional Public Health Laboratory of Thessaly, 41222 Larissa, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2018,11,30]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"e183","DOI":"10.1016\/j.ajic.2016.06.018","article-title":"Are there effective interventions to prevent hospital-acquired Legionnaires\u2019 disease or to reduce environmental reservoirs of Legionella in hospitals? A systematic review","volume":"44","author":"Almeida","year":"2016","journal-title":"Am. J. Infect. Control"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"2417","DOI":"10.1001\/archinte.1994.00420210049006","article-title":"Surveillance for Legionnaires\u2019 disease: Risk factors for morbidity and mortality","volume":"154","author":"Marston","year":"1994","journal-title":"Arch. Intern. Med."},{"key":"ref_3","unstructured":"(2018, November 13). Center for Disease Control and Prevention: Legionella (Legionnaires\u2019 Disease and Pontiac Fever), Available online: https:\/\/www.cdc.gov\/legionella\/clinicians\/disease-specifics.html."},{"key":"ref_4","first-page":"7","article-title":"Microbiology and epidemiology of legionnaire\u2019s disease","volume":"31","author":"Burillo","year":"2017","journal-title":"Infect. Dis. Clin."},{"key":"ref_5","unstructured":"European Centre for Disease Prevention and Control (2016). Legionnaires\u2019 Disease in Europe, 2014, ECDC."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"898","DOI":"10.1086\/676871","article-title":"On-site availability of Legionella testing in acute care hospitals, United States","volume":"35","author":"Garrison","year":"2014","journal-title":"Infect. Control Hosp. Epidemiol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1086\/345529","article-title":"Diagnosis of Legionella infection","volume":"36","author":"Reller","year":"2003","journal-title":"Clin. Infect. Dis."},{"key":"ref_8","unstructured":"(2018, September 10). Hellenic Centre of Disease Control and Prevention. Available online: http:\/\/www.keelpno.gr\/en-us\/hcdcp.aspx."},{"key":"ref_9","unstructured":"(2018, September 10). Greek Ministry of Tourism, Available online: http:\/\/www.mintour.gov.gr\/Statistics\/statistiki."},{"key":"ref_10","unstructured":"(2018, September 10). Greek Tourism Confederation. Available online: http:\/\/sete.gr\/el\/statistika-vivliothiki\/statistika\/."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"20240","DOI":"10.2807\/ese.17.32.20240-en","article-title":"Travel-associated Legionnaires disease in residents from England and Wales travelling to Corfu, Greece, August to October 2011","volume":"17","author":"Maini","year":"2012","journal-title":"Euro Surveill."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1318","DOI":"10.1038\/ismej.2017.14","article-title":"Impact of water heater temperature setting and water use frequency on the building plumbing microbiome","volume":"11","author":"Ji","year":"2017","journal-title":"ISME J."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Ji, P., Parks, J., Edwards, M.A., and Pruden, A. (2015). Impact of water chemistry, pipe material and stagnation on the building plumbing microbiome. PLoS ONE, 10.","DOI":"10.1371\/journal.pone.0141087"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1489","DOI":"10.1128\/AEM.02191-06","article-title":"Risk factors for contamination of hotel water distribution systems by Legionella species","volume":"73","author":"Mouchtouri","year":"2007","journal-title":"Appl. Environ. Microbiol."},{"key":"ref_15","first-page":"50","article-title":"The effect of temperature and chlorine residual on the presence of Legionella spp. in water systems of public and tourist facilities","volume":"7","author":"Besic","year":"2017","journal-title":"J. Health Sci."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1007\/s40572-018-0201-4","article-title":"Outbreaks of Legionnaires\u2019 Disease and Pontiac Fever 2006\u20132017","volume":"5","author":"Hamilton","year":"2018","journal-title":"Curr. Environ. Health Rep."},{"key":"ref_17","unstructured":"International Organization for Standardization: ISO 5667-5 (2006). Water Quality- Sampling\u2014Part 5: Guidance on Sampling of Drinking Water from Treatment Works and Piped Distribution Systems, ISO."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1074","DOI":"10.1017\/S0950268806006042","article-title":"Evaluation of standardized scored inspections for Legionnaires\u2019 disease prevention, during the Athens 2004 Olympics","volume":"134","author":"Hadjichristodoulou","year":"2006","journal-title":"Epidemiol. Infect."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1071\/NB00067","article-title":"Environmental health preparation for the Sydney 2000 Olympic and Paralympic Games","volume":"11","author":"Banwell","year":"2000","journal-title":"New South Wales Public Health Bull."},{"key":"ref_20","unstructured":"International Organization for Standardization: ISO 6222:1999 (1999). Water Quality\u2014Enumeration of Culturable Micro-Organisms\u2014Colony Count by Inoculation in a Nutrient Agar Culture Medium, ISO."},{"key":"ref_21","unstructured":"International Organization for Standardization: ISO 11731:1998 (1998). Water Quality\u2014Detection and Enumeration of Legionella, ISO."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1007\/BF00145044","article-title":"Isolation of Legionella pneumophila from hotels of Greece","volume":"5","author":"Alexiou","year":"1989","journal-title":"Eur. J. Epidemiol."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1080\/09603123.2011.643229","article-title":"Prevalence of Legionella spp. in water systems of hospitals and hotels in South Western Greece","volume":"22","author":"Fragou","year":"2012","journal-title":"Int. J. Environ. Health Res."},{"key":"ref_24","first-page":"335","article-title":"Legionella species in year-round vs. seasonal accommodation water supply systems","volume":"62","author":"Mikrut","year":"2011","journal-title":"Arch. Ind. Hyg. Toxicol."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1576","DOI":"10.1111\/j.1365-2672.2009.04553.x","article-title":"Evaluation of Legionella pneumophila contamination in Italian hotel water systems by quantitative real-time PCR and culture methods","volume":"108","author":"Bonetta","year":"2010","journal-title":"J. Appl. Microbiol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"5805","DOI":"10.1128\/AEM.71.10.5805-5813.2005","article-title":"Legionella contamination in hot water of Italian hotels","volume":"71","author":"Borella","year":"2005","journal-title":"Appl. Environ. Microbiol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1111\/j.1365-2672.2004.02458.x","article-title":"Legionella waterline colonization: Detection of Legionella species in domestic, hotel and hospital hot water systems","volume":"98","author":"Leoni","year":"2005","journal-title":"J. Appl. Microbiol."},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Totaro, M., Valentini, P., Costa, A.L., Frendo, L., Cappello, A., Casini, B., Micolli, M., Privitera, G., and Baggiani, A. (2017). Presence of Legionella spp. in Hot Water Networks of Different Italian Residential Buildings: A Three-Year Survey. Int. J. Environ. Res. Public Health, 14.","DOI":"10.20944\/preprints201710.0058.v1"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1111\/j.1708-8305.2007.00146.x","article-title":"Colonization of Legionella species in hotel water systems in Turkey","volume":"14","author":"Erdogan","year":"2007","journal-title":"J. Travel Med."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"664","DOI":"10.1111\/j.1600-0463.2005.apm_118.x","article-title":"Prevalence of Legionella pneumophila serogroup 1 in water distribution systems in Izmir province of Turkey","volume":"113","author":"Uzel","year":"2005","journal-title":"APMIS"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"1315","DOI":"10.1016\/S0140-6736(83)91203-5","article-title":"Legionella in hospital and hotel water supplies","volume":"322","author":"Bartlett","year":"1983","journal-title":"Lancet"},{"key":"ref_32","unstructured":"Hellenic Government (2017). Ministerial Decision No. G1(D)\/GP\/OIK. 67322\/6-9-2017, Water Quality for Human Consumption, Adaptation of the Greek Legislation to Directive 98\/83\/EC of the COUNCIL DIRECTIVE 98\/83\/EC of 3 November 1998 on the Quality of Water Intended for Human Consumption as Amended by Directive 2015\/1787(L260, 7.10.2015)."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"829","DOI":"10.1136\/jech.2005.041707","article-title":"Waterborne diseases prevention: Evaluation of inspection scoring system for water sites according to water microbiological tests during the Athens 2004 pre-Olympic and Olympic period","volume":"60","author":"Hadjichristodoulou","year":"2006","journal-title":"J. Epidemiol. Community Health"},{"key":"ref_34","unstructured":"(2007). Legionella and the Prevention of Legionellosis, WHO."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1016\/j.jhin.2007.10.020","article-title":"Efficacy of point-of-entry copper\u2013silver ionisation system in eradicating Legionella pneumophila in a tropical tertiary care hospital: Implications for hospitals contaminated with Legionella in both hot and cold water","volume":"68","author":"Chen","year":"2008","journal-title":"J. Hosp. Infect."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1086\/516283","article-title":"Intermittent use of copper-silver ionization for Legionella control in water distribution systems: A potential option in buildings housing individuals at low risk of infection","volume":"26","author":"Liu","year":"1998","journal-title":"Clin. Infect. Dis."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"919","DOI":"10.1093\/infdis\/169.4.919","article-title":"Controlled evaluation of copper-silver ionization in eradicating Legionella pneumophila from a hospital water distribution system","volume":"169","author":"Liu","year":"1994","journal-title":"J. Infect. Dis."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"2104","DOI":"10.1111\/j.1365-2672.2008.03932.x","article-title":"Detection of culturable and nonculturable Legionella species from hot water systems of public buildings in Japan","volume":"105","author":"Edagawa","year":"2008","journal-title":"J. Appl. Microbiol."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"1775","DOI":"10.1128\/aem.53.8.1775-1779.1987","article-title":"An alkaline approach to treating cooling towers for control of Legionella pneumophila","volume":"53","author":"Conley","year":"1987","journal-title":"Appl. Environ. Microbiol."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"2315","DOI":"10.1016\/j.watres.2011.01.009","article-title":"Parameters predictive of Legionella contamination in hot water systems: Association with trace elements and heterotrophic plate counts","volume":"45","author":"Bargellini","year":"2011","journal-title":"Water Res."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"520","DOI":"10.1016\/j.ajic.2006.03.007","article-title":"Influence of amoebae and physical and chemical characteristics of water on presence and proliferation of Legionella species in hospital water systems","volume":"34","author":"Lasheras","year":"2006","journal-title":"Am. J. Infect. Control"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"546","DOI":"10.1034\/j.1600-0463.2003.1110503.x","article-title":"Colonization of hospital water systems by legionellae, mycobacteria and other heterotrophic bacteria potentially hazardous to risk group patients","volume":"111","author":"Kusnetsov","year":"2003","journal-title":"APMIS"},{"key":"ref_43","unstructured":"(2017). European Technical Guidelines for Prevention, Control and Investigation of Infections Caused by Legionella Species, ECDC. The European Guidelines Working Group June 2017."}],"container-title":["International Journal of Environmental Research and Public Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1660-4601\/15\/12\/2707\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T15:33:44Z","timestamp":1760196824000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1660-4601\/15\/12\/2707"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,11,30]]},"references-count":43,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2018,12]]}},"alternative-id":["ijerph15122707"],"URL":"https:\/\/doi.org\/10.3390\/ijerph15122707","relation":{},"ISSN":["1660-4601"],"issn-type":[{"value":"1660-4601","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,11,30]]}}}