{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,24]],"date-time":"2026-03-24T14:58:48Z","timestamp":1774364328890,"version":"3.50.1"},"reference-count":24,"publisher":"MDPI AG","issue":"24","license":[{"start":{"date-parts":[[2019,12,5]],"date-time":"2019-12-05T00:00:00Z","timestamp":1575504000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"InnoEnergy Master School, Eindhoven, The Netherland (Grant Smog-Health-For)","award":["08\/020\/BK18\/0015"],"award-info":[{"award-number":["08\/020\/BK18\/0015"]}]},{"name":"Faculty of Energy and Environmental Engineering, Silesian University of Technology","award":["statutory research"],"award-info":[{"award-number":["statutory research"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IJERPH"],"abstract":"<jats:p>(1) Background: Since exposure to airborne bacteria and fungi may be especially hazardous in hospitals and outpatient clinics, it is essential to sterilize the air in such rooms. The purpose of this study was to estimate the decrease in the concentration of airborne bacteria and fungi in the selected hospital and clinic rooms due to the work of the electron wind generator (EWG). (2) Methods: EWG is an air movement and air purification device using a sophisticated combination of electrode topology and specially designed high-voltage power supply. (3) Results: The concentration of both bacteria and fungi in the small patient\u2019s room dropped to approximately 25% of the initial (background) concentration. In the larger patient\u2019s room, the concentration dropped to 50% and 80% of the background concentration for bacteria and fungi, respectively. (4) Conclusions: The obtained data show that the studied sterilization process can be described by the exponential function of time. Moreover, the application of an activated carbon filter into EWG significantly decreases the concentration of ozone in the sterilized room. Sterilization by EWG significantly changes the characteristic of species and genera of airborne bacteria and shifts the main peak of the size distribution of airborne bacteria into the coarser bio-particles.<\/jats:p>","DOI":"10.3390\/ijerph16244935","type":"journal-article","created":{"date-parts":[[2019,12,5]],"date-time":"2019-12-05T11:16:31Z","timestamp":1575544591000},"page":"4935","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["The Study of the Sterilization of the Indoor Air in Hospital\/Clinic Rooms by Using the Electron Wind Generator"],"prefix":"10.3390","volume":"16","author":[{"given":"J\u00f3zef S.","family":"Pastuszka","sequence":"first","affiliation":[{"name":"Faculty of Energy and Environmental Protection, Department of Air Protection, Silesian University of Technology, 44-100 Gliwice, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7476-0614","authenticated-orcid":false,"given":"Walter","family":"Mucha","sequence":"additional","affiliation":[{"name":"Faculty of Energy and Environmental Protection, Department of Air Protection, Silesian University of Technology, 44-100 Gliwice, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Agnieszka","family":"Wlaz\u0142o","sequence":"additional","affiliation":[{"name":"Institute of Occupational Medicine &amp; Environmental Health, 41-200 Sosnowiec, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Danuta","family":"Lis","sequence":"additional","affiliation":[{"name":"Institute of Occupational Medicine &amp; Environmental Health, 41-200 Sosnowiec, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ewa","family":"Marchwi\u0144ska-Wyrwa\u0142","sequence":"additional","affiliation":[{"name":"Faculty of Public Health, Silesian University of Medicine, 41-902 Bytom, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2499-1764","authenticated-orcid":false,"given":"Anna","family":"Mainka","sequence":"additional","affiliation":[{"name":"Faculty of Energy and Environmental Protection, Department of Air Protection, Silesian University of Technology, 44-100 Gliwice, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2019,12,5]]},"reference":[{"key":"ref_1","first-page":"187","article-title":"Bioaerosol Health Effects and Exposure Assessment: Progress and Prospects","volume":"47","author":"Douwes","year":"2003","journal-title":"Ann. Occup. Hyg."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1080\/10473220301451","article-title":"Health effects of indoor fungal bioaerosol exposure","volume":"18","author":"Fung","year":"2003","journal-title":"Appl. Occup. Environ. Hyg."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"5","DOI":"10.5271\/sjweh.103","article-title":"Health effects of indoor-air microorganisms","volume":"22","author":"Husman","year":"1996","journal-title":"Scand. J. Work Environ. Health"},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Pastuszka, J.S. (2016). Fungi, bacteria and other biopollutants. Synergic Influence of Gaseous, Particulate and Biological Pollutants on Human Health, CRC Press, Taylor & Francis Group.","DOI":"10.1201\/b19592"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"3833","DOI":"10.1016\/S1352-2310(99)00527-0","article-title":"Bacterial and fungal aerosol in indoor environment in Upper Silesia, Poland","volume":"34","author":"Pastuszka","year":"2000","journal-title":"Atmos. Environ."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1007\/s10661-009-1252-7","article-title":"Indoor air quality in university environments","volume":"170","author":"Grande","year":"2010","journal-title":"Environ. Monit. Assess."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/j.atmosenv.2015.03.039","article-title":"Non-culturable bioaerosols in indoor settings: Impact on health and molecular approaches for detection","volume":"110","author":"Perrott","year":"2015","journal-title":"Atmos. Environ."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1007\/s10453-015-9419-x","article-title":"Bacterial aerosols in an urban nursery school in Gliwice, Poland: A case study","volume":"32","author":"Mainka","year":"2016","journal-title":"Aerobiologia (Bologna)"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"729","DOI":"10.1007\/s11869-018-0579-z","article-title":"Microbiological indoor air quality in an office building in Gliwice, Poland: Analysis of the case study","volume":"11","author":"Kozielska","year":"2018","journal-title":"Air Qual. Atmos. Health"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1093\/occmed\/kqy095","article-title":"Do exposures to aerosols pose a risk to dental professionals?","volume":"68","author":"Kobza","year":"2018","journal-title":"Occup. Med. (Chic. Ill)"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1016\/j.envres.2017.10.001","article-title":"Concentrations of Staphylococcus species in indoor air as associated with other bacteria, season, relative humidity, air change rate, and S. aureus-positive occupants","volume":"160","author":"Madsen","year":"2018","journal-title":"Environ. Res."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1177\/1420326X0201100505","article-title":"Monitoring indoor airborne fungi and bacteria in the different areas of Trakya University Hospital, Edirne, Turkey","volume":"11","author":"Sarica","year":"2002","journal-title":"Indoor Built Environ."},{"key":"ref_13","first-page":"883","article-title":"Bacterial aerosol in Silesian hospitals: Preliminary results","volume":"14","author":"Pastuszka","year":"2005","journal-title":"Pol. J. Environ. Stud."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"King, M.-F., Camargo-Valero, M., Matamoros-Veloza, A., Sleigh, P., and Noakes, C. (2017). An Effective surrogate tracer technique for S. aureus bioaerosols in a mechanically ventilated hospital room replica using dilute aqueous lithium chloride. Atmosphere (Basel), 8.","DOI":"10.3390\/atmos8120238"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1016\/j.scs.2017.04.011","article-title":"A review of air filtration technologies for sustainable and healthy building ventilation","volume":"32","author":"Liu","year":"2017","journal-title":"Sustain. Cities Soc."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1016\/j.jaerosci.2010.03.002","article-title":"Use of carbon nanotube filter in removing bioaerosols","volume":"41","author":"Guan","year":"2010","journal-title":"J. Aerosol Sci."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"3338","DOI":"10.1021\/es048808x","article-title":"Inactivation of microorganisms using electrostatic fields","volume":"39","author":"Yao","year":"2005","journal-title":"Environ. Sci. Technol."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1111\/j.1600-0668.2005.00364.x","article-title":"Evaluation of ionic air purifiers for reducing aerosol exposure in confined indoor spaces","volume":"15","author":"Grinshpun","year":"2005","journal-title":"Indoor Air"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1111\/j.1600-0668.2007.00512.x","article-title":"Removal of viable bioaerosol particles with a low-efficiency HVAC filter enhanced by continuous emission of unipolar air ions","volume":"18","author":"Huang","year":"2008","journal-title":"Indoor Air"},{"key":"ref_20","unstructured":"Pastuszka, J.S., Mucha, W., and Marchwi\u0144ska-Wyrwa\u0142, E. (2009, January 6\u201311). The portable cleaner device for filtration and sterilization of indoor air. Proceedings of the European Aerosol Conference, Karlsruhe, Germany."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1016\/0960-1686(92)90166-I","article-title":"Performance of bioaerosol samplers: Collection characteristics and sampler design considerations","volume":"26","author":"Nevalainen","year":"1992","journal-title":"Atmos. Environ. Part A Gen. Top."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/j.jaerosci.2017.01.007","article-title":"Concentrations and size distributions of viable bioaerosols under various weather conditions in a typical semi-arid city of Northwest China","volume":"106","author":"Li","year":"2017","journal-title":"J. Aerosol Sci."},{"key":"ref_23","unstructured":"Dillon, H.K., Heinsohn, P.A., Miller, J.D., American Industrial Hygiene Association, and Biosafety Committee (1996). Field Guide for the Determination of Biological Contaminants in Environmental Samples, American Industrial Hygiene Association."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"797","DOI":"10.1177\/1420326X11425965","article-title":"Seasonal and Spatial Variations of Bioaerosols in Indoor Urban Environments, Ankara, Turkey","volume":"21","author":"Mentese","year":"2012","journal-title":"Indoor Built Environ."}],"container-title":["International Journal of Environmental Research and Public Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1660-4601\/16\/24\/4935\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T13:40:39Z","timestamp":1760190039000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1660-4601\/16\/24\/4935"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12,5]]},"references-count":24,"journal-issue":{"issue":"24","published-online":{"date-parts":[[2019,12]]}},"alternative-id":["ijerph16244935"],"URL":"https:\/\/doi.org\/10.3390\/ijerph16244935","relation":{},"ISSN":["1660-4601"],"issn-type":[{"value":"1660-4601","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,12,5]]}}}