{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,22]],"date-time":"2026-07-22T03:00:40Z","timestamp":1784689240776,"version":"3.55.0"},"reference-count":68,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2020,3,21]],"date-time":"2020-03-21T00:00:00Z","timestamp":1584748800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IJERPH"],"abstract":"<jats:p>The quality of work environment, temperature changes and humidity must be controlled in every production process and in the locations where employees are present. The aim of this paper is to objectively assess the exposure of employees to microclimatic factors of the workplace environment: the warehouse, changing rooms, office and cold room refrigerator. Data were obtained in real working conditions. The heat stress due to cold and heat exposure in the individual locations was evaluated using the WBGT (wet bulb globe temperature) indicator. The parameters of the hygrothermal microclimate (HTM) were objectified by a QUES Temp 44\/46 T spherical thermometer. The measurements were performed both in cold and hot periods of the year. The measurements confirmed standard temperatures for individual types of interiors in the winter period, but in the summer period there was a variability of results, leading to the thermal discomfort of employees. The assessment of the WBGT index revealed that nearly 80% of employees are susceptible to hypothermia as a result of thermal stress conditions. It was proven that the temperatures measured by a spherical thermometer in the hottest room were 8.62% higher than the calculated operating temperature, while the difference in the cold room refrigerator was only 1.28% higher.<\/jats:p>","DOI":"10.3390\/ijerph17062092","type":"journal-article","created":{"date-parts":[[2020,3,23]],"date-time":"2020-03-23T04:03:01Z","timestamp":1584936181000},"page":"2092","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Analysis of Hygrothermal Microclimatic (HTM) Parameters in Specific Food Storage Environments in Slovakia"],"prefix":"10.3390","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9424-2024","authenticated-orcid":false,"given":"Iveta","family":"Markov\u00e1","sequence":"first","affiliation":[{"name":"Department of Fire Engineering, Faculty of Security Engineering, University of \u017dilina, Univerzitn\u00e1 1, 010 26 \u017dilina, Slovakia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ivana","family":"Turekov\u00e1","sequence":"additional","affiliation":[{"name":"Constantine the Philosopher University in Nitra, Tr. A. Hlinku 1, 949 74 Nitra, Slovakia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jana","family":"Ja\u010fu\u010fov\u00e1","sequence":"additional","affiliation":[{"name":"Matej Bel University, Faculty of Natural Sciences, Department of Environmental Management, Tajovskeho 40, 97401 Banska Bystrica, Slovakia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Em\u00edlia","family":"Hroncov\u00e1","sequence":"additional","affiliation":[{"name":"European Science and Research Institute, A. Hlinku 29, 96001 Zvolen, Slovakia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2020,3,21]]},"reference":[{"key":"ref_1","unstructured":"SEA (2016, April 01). Report of Environment in Slovak Republic for 2015. Available online: https:\/\/www.enviroportal.sk\/uploads\/spravy\/sprava-2015-final-ep.pdf."},{"key":"ref_2","unstructured":"SEA (2017, April 01). Report of Environment in Slovak Republic for 2016. Available online: https:\/\/www.enviroportal.sk\/uploads\/report\/8142.pdf."},{"key":"ref_3","unstructured":"SEA (2018, April 01). Report of Environment in Slovak Republic for 2017. Available online: https:\/\/www.enviroportal.sk\/uploads\/report\/6961.pdf."},{"key":"ref_4","unstructured":"Turekov\u00e1, I., and Markov\u00e1, I. (2018). Indoor of Buildings, Constantine the Philosopher University in Nitra. [1st ed.]. (In Slovak)."},{"key":"ref_5","unstructured":"Love\u010dek, T., Ristvej, J., Sventekov\u00e1, E., \u0160iser, A., and Ve\u013eas, A. (2016, January 10\u201311). Research of competencies of crisis and security managers. Proceedings of the 3rd International Conference Economic, Business Management and Educational Innovation (EBMEI 2016), Prague, Czech Republic."},{"key":"ref_6","unstructured":"Slamkov\u00e1, E., Dulina, \u013d., and Tabakov\u00e1, M. (2010). Ergonomic in Industry, GEORG. [1st ed.]. (in Slovak)."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1007\/s00484-014-0819-3","article-title":"A comprehensive catalogue and classification of human thermal climate indices","volume":"59","author":"Grigorieva","year":"2015","journal-title":"Int. J. Biometeorol."},{"key":"ref_8","unstructured":"Mekjavic, I.B., Banister, E.W., and Morrison, J.B. (1988). Standards for human exposure to heat. Environmental Ergonomics, Taylor & Francis."},{"key":"ref_9","first-page":"255","article-title":"Thermal indices and thermophysiological modeling for heat stress","volume":"6","author":"Havenith","year":"2011","journal-title":"Compr. Physiol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1016\/0013-9351(80)90146-2","article-title":"Seventy-five years of searching for a heat index","volume":"22","author":"Lee","year":"1980","journal-title":"Environ. Res."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1080\/00140139508925080","article-title":"The Commission of the European Communities Seminar on heat stress indices","volume":"38","author":"Parsons","year":"1995","journal-title":"Ergonomics"},{"key":"ref_12","unstructured":"Bethea, D., and Parsons, K. (2002). The Development of a Practical Heat Stress Assessment Methodology for Use in UK Industry (Research Report 008), Department of Human Sciences, Loughborough University."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"95","DOI":"10.2486\/indhealth.MS1097","article-title":"Thermal environment assessment reliability using temperature\u2013humidity indices","volume":"49","author":"Palella","year":"2011","journal-title":"Ind. Health"},{"key":"ref_14","first-page":"955","article-title":"WBGT Index Revisited After 60 Years of Use","volume":"58","author":"Malchaire","year":"2014","journal-title":"Ann. Occup. Hyg."},{"key":"ref_15","unstructured":"ISO 7243 (1989). Hot Environments\u2014Estimation of the Heat Stress on Working Man, Based on the WBGT-Index (wet Bulb Globe Temperature), International Organization for Standardization."},{"key":"ref_16","unstructured":"ISO 7933 (2004). Ergonomics of the Thermal Environment\u2014Analytical Determination and Interpretation of Heat Stress Using Calculation of the Predicted Heat Strain, International Organization for Standardization."},{"key":"ref_17","unstructured":"ANSI\/ASHRAE Standard 55: 2017 (2017). Thermal Environmental Conditions for Human Occupancy, ASHRAE Headquarters."},{"key":"ref_18","unstructured":"\u00c7engel, Y.A., and Boles, M.A. (2015). Thermodynamics: An Engineering Approach, McGraw-Hill Education. [8th ed.]."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1016\/S0378-7788(02)00006-3","article-title":"Adaptive thermal comfort and sustainable thermal standards for buildings","volume":"34","author":"Nicol","year":"2002","journal-title":"Energy Build."},{"key":"ref_20","unstructured":"ISO 7730 (1994). Moderate Thermal Environments\u2014Determination of the PMV and PPD Indices and Specification of the Conditions for Thermal Comfort, International Organization for Standardization."},{"key":"ref_21","unstructured":"Fanger, P.O. (1970). Thermal Comfort. Analysis and Applications in Environmental Engineering, Danish Technical Press."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1089","DOI":"10.1016\/j.apergo.2012.03.010","article-title":"Examination of thermal comfort in a hospital using PMV-PPD model","volume":"43","author":"Pourshaghaghy","year":"2012","journal-title":"Appl. Ergon."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/j.buildenv.2011.09.012","article-title":"RLF and TS fuzzy model identification of indoor thermal comfort based on PMV\/PPD","volume":"49","author":"Homod","year":"2012","journal-title":"Build. Environ."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1016\/j.enbuild.2009.11.017","article-title":"Parametric studies and evaluations of indoor thermal environment in wet season using a field survey and PMV\u2013PPD method","volume":"42","author":"Wei","year":"2010","journal-title":"Energy Build."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1016\/j.buildenv.2019.01.055","article-title":"Analysis of the accuracy on PMV\u2014PPD model using the ASHRAE Global Thermal Comfort Database II","volume":"153","author":"Cheung","year":"2019","journal-title":"Build. Environ."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1080\/17512549.2007.9687269","article-title":"Field studies of indoor thermal comfort and the progress of the adaptive approach","volume":"1","author":"Humphreys","year":"2007","journal-title":"Adv. Build. Energy Res."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/S0378-7788(97)00053-4","article-title":"Thermal adaptation in the built environment: A literature review","volume":"27","author":"Brager","year":"1998","journal-title":"Energy Build."},{"key":"ref_28","unstructured":"De Dear, R., and Brager, G.S. (1998). Developing an Adaptive Model of Thermal Comfort and Preference, Center for Environmental Design Research, UC Berkeley."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1016\/j.buildenv.2011.07.022","article-title":"A study on the effects of thermal, luminous, and acoustic environments on indoor environmental comfort in offices","volume":"49","author":"Huang","year":"2012","journal-title":"Build. Environ."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"109511","DOI":"10.1016\/j.enbuild.2019.109511","article-title":"Determination of the energy performance indicator of kindergartens through design, measured and recommended parameters","volume":"204","author":"Gajic","year":"2019","journal-title":"Energy Build."},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Fabozzi, M., and Dama, A. (2019). Field study on thermal comfort in naturally ventilated and air-conditioned university classrooms. Indoor Built Environ.","DOI":"10.1177\/1420326X19887481"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"2698","DOI":"10.1016\/j.mex.2019.11.004","article-title":"Classroom-comfort-data: A method to collect comprehensive information on thermal comfort in school classrooms","volume":"6","author":"Rodriguez","year":"2019","journal-title":"Methodsx"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"590","DOI":"10.1007\/978-3-319-94706-8_62","article-title":"A Review on Thermal Comfort Evaluation of Head-Worn Devices","volume":"Volume 777","author":"Rebelo","year":"2019","journal-title":"Advances in Ergonomics in Design (AHFE 2018)"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s004840050075","article-title":"Indoor climate and air quality","volume":"42","author":"Martinac","year":"1998","journal-title":"Int. J. Biometeorol."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1016\/j.buildenv.2012.09.023","article-title":"Experimental evaluation of insulation materials for walls and roofs and their impact on indoor thermal comfort under composite climate","volume":"59","author":"Kumar","year":"2013","journal-title":"Build. Environ."},{"key":"ref_36","first-page":"78","article-title":"Reakce lidsk\u00e9ho organismu na tepelnou z\u00e1t\u011b\u017e","volume":"1","year":"2009","journal-title":"Spektrum"},{"key":"ref_37","unstructured":"De Turck, S., Laverge, J., and Van Den Bossche, N. (2018). Personal HVAC: A Simulation Based Feasibility Study. [Ph.D. Dissertation, Faculty of Engineering and Architecture, Ghent University]. Available online: https:\/\/lib.ugent.be\/catalog\/rug01:002495100."},{"key":"ref_38","unstructured":"Decree of the Ministry of Health of the Slovak Republic no (2016). 99\/2016 Coll. on Protection of Health Against Heat and Cold Stress at Work, Ministry of Health of the Slovak Republic. (In Slovakia)."},{"key":"ref_39","unstructured":"Decree of the Ministry of Health of the Slovak Republic 259\/2008 Coll (2008). on the Details of the Requirements for the Indoor Environment of Buildings and the Minimum Requirements for Lower-Standard Apartments and Buildings, Ministry of Health of the Slovak Republic. (In Slovakia)."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"100213","DOI":"10.1016\/j.wace.2019.100213","article-title":"A comparison of the correlation between heat stress indices (UTCI, WBGT, WBDT, TSI) and physiological parameters of workers in Iran","volume":"26","author":"Zare","year":"2019","journal-title":"Weather Clim. Extrem."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"790","DOI":"10.1038\/s41370-018-0076-3","article-title":"Heat waves in South Korea: Differences of heat wave characteristics by thermal indices","volume":"29","author":"Heo","year":"2019","journal-title":"J. Expo. Environ. Epidemol."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"62","DOI":"10.2486\/indhealth.2017-0048","article-title":"Assessment of thermal environments: Working conditions in the portuguese glass industry","volume":"56","author":"Oliveira","year":"2018","journal-title":"Ind. Health"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1016\/j.envres.2018.12.059","article-title":"New approach to identifying proper thresholds for a heat warning system using health risk increments","volume":"170","author":"Cheng","year":"2019","journal-title":"Environ. Res."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"114","DOI":"10.4028\/www.scientific.net\/AMR.1001.114","article-title":"The Environmental and Energy Potential of Incinerating Various Biomass Mixtures","volume":"1001","author":"Balog","year":"2014","journal-title":"Adv. Mater. Res."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"1357","DOI":"10.1007\/s00484-019-01752-8","article-title":"Investigation into the thermal comfort of conditions by different seasonal field surveys in China, Guangzhou","volume":"63","author":"Fang","year":"2019","journal-title":"Int. J. Biometeorol."},{"key":"ref_46","unstructured":"Draho\u0161, R., and Draho\u0161, M. (2015, March 28). Zdravotn\u00e9 aspekty tepelno-vlhkostnej mikrokl\u00edmy pri pr\u00e1ci (Health Aspects of Heat-Moisture Microclimate at Work). (In Slovak)."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"388","DOI":"10.2486\/indhealth.44.388","article-title":"Thermal comfort and the heat stress indices","volume":"44","author":"Epstein","year":"2006","journal-title":"Ind. Health"},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1016\/S0306-4565(01)00055-9","article-title":"An environmental stress index (ESI) as a substitute for the wet bulb globe temperature (WBGT)","volume":"26","author":"Moran","year":"2001","journal-title":"J. Therm. Biol."},{"key":"ref_49","unstructured":"Makovick\u00e1-Osvaldov\u00e1, L. Risk Management at Occupational Safety and Health. Proceedings of the International Scientific Conference."},{"key":"ref_50","unstructured":"ACGIH (2004). TLVs and BELs. Threshold Limit Values for Chemicals Substances and Physical Agents and Biological Exposure Indices, ACGIH Signature Publications."},{"key":"ref_51","unstructured":"US Department of Labor (1999). OSHA. Technical Manual (OTM) (TED 01-00-015) Section III, Heat Stress, US Department of Labor. Chapter 4."},{"key":"ref_52","unstructured":"AIHA (1975). Heat exchange and human tolerence limits. Heating and Cooling for Man Industry, American Industrial Hygiene Association. [2nd ed.]."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1016\/j.buildenv.2009.06.018","article-title":"Thermal sensation and comfort models for non-uniform and transient environments: Part I: Local sensation of individual body parts","volume":"45","author":"Zhang","year":"2010","journal-title":"Build. Environ."},{"key":"ref_54","unstructured":"OOF\u017dP\/268\/2013 (2013). Odborn\u00e9 Usmernenie Ministerstva Zdravotn\u00edctva Slovenskej Republiky, Ktor\u00fdm sa Upravuje Postup pri Meran\u00ed a Hodnoten\u00ed Tepelno-Vlhkostnej Mikrokl\u00edmy Expert Guideline of the Ministry of Health of the Slovak Republic Regulating the Procedure for Measurement and Evaluation of Thermal-Humidity Microclimate, Ministry of Health of the Slovak Republic. (In Slovakia)."},{"key":"ref_55","unstructured":"ISO 7726:1998 (1998). Ergonomics of the Thermal Environment. Instruments for Measuring Physical Quantities, International Organization for Standardization."},{"key":"ref_56","unstructured":"Fri\u010d, M., \u0160aligov\u00e1, D., and Chovancov\u00e1, L. (2015). Meranie a hodnotenie tepelno-vlhkostnej mikrokl\u00edmy v pracovnom prostred\u00ed (Measurement and evaluation of thermal-moisture microclimate in working environment). \u017divotn\u00e9 podmienky a zdravie: Zborn\u00edk vedeck\u00fdch pr\u00e1c (In Living Conditions and Health: Proceedings of scientific papers), \u00darad verejn\u00e9ho zdravotn\u00edctva (Public Health Authority). (In Slovak)."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1515\/aucts-2015-0031","article-title":"Experimental measurments and evaluation of indoor microclimate conditions","volume":"66","year":"2015","journal-title":"Acta Univ. Cibiniensis Tech. Ser."},{"key":"ref_58","unstructured":"Ondrejkov\u00e1, \u013d. (2016, June 20). Z\u00e1\u0165a\u017e teplom a chladom pri pr\u00e1ci v nov\u00fdch legislat\u00edvnych \u00faprav\u00e1ch (Heat and Cold Load at Work in New Legislation). Available online: https:\/\/www.mzdovecentrum.sk\/clanok-z-titulky\/zataz-teplom-a-chladom-pri-praci-v-novych-legislativnych-upravach-10.htm."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1016\/j.proeng.2014.02.216","article-title":"Thermal Environment Evaluation According to Indices in Industrial Workplaces","volume":"69","author":"Sokolova","year":"2014","journal-title":"Procedia Eng."},{"key":"ref_60","unstructured":"Decree 28167\/2007-OL (2007). Food Code of the Slovak Republic, Of the Ministry of Agriculture of the Slovak Republic and the Ministry of Health of the Slovak Republic."},{"key":"ref_61","first-page":"12","article-title":"Thermal Comfort and Optimum. Humidity Part 1","volume":"42","author":"Jokl","year":"2002","journal-title":"Acta Polytech."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"1057","DOI":"10.1016\/j.enbuild.2010.09.001","article-title":"Quantitative measurement of productivity loss due to thermal discomfort","volume":"43","author":"Lan","year":"2011","journal-title":"Energy Build."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1016\/j.buildenv.2013.05.015","article-title":"Concept of the equivalent wet bulb globe temperature index for indicating safe thermal occupational environments","volume":"67","author":"Sakoia","year":"2013","journal-title":"Build. Environ."},{"key":"ref_64","unstructured":"Litti, G. (2018). Methods and criteria for energy environmental retrofitting of historic and heritage buildings: Diagnosis and Assessment. [Ph.D. Dissertation, Faculty of Applied Engineering Sciences, EMIB Energy and Materials in Infrastructure and Buildings, University of Antwerp]."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"956","DOI":"10.1016\/j.culher.2016.05.009","article-title":"Indoor microclimatic study for Cultural Heritage protection and preventive conservation in the Palatina Library","volume":"22","author":"Balocco","year":"2016","journal-title":"J. Cult. Herit."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"1079","DOI":"10.1016\/j.culher.2016.06.001","article-title":"Multidisciplinary risk-based analysis for supporting the decision making process on conservation, energy efficiency, and human comfort in museum buildings","volume":"22","author":"Lucchi","year":"2016","journal-title":"Review. J. Cult. Herit."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.ijsbe.2016.03.006","article-title":"Impact of indoor environmental quality on occupant well-being and comfort: A review of the literature","volume":"5","author":"Arif","year":"2016","journal-title":"Int. J. Sustain. Built Environ."},{"key":"ref_68","unstructured":"CEN Standard EN 15251: 2007 (2007). Indoor Environmental Input Parameters for Design and Assessment of Energy Performance of Buildingsaddressing Indoor Air Quality, Thermal Environment, Lighting and Acoustics, Comit\u00e9 Europ\u00e9en de Normalisation."}],"container-title":["International Journal of Environmental Research and Public Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1660-4601\/17\/6\/2092\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T09:10:26Z","timestamp":1760173826000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1660-4601\/17\/6\/2092"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,3,21]]},"references-count":68,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2020,3]]}},"alternative-id":["ijerph17062092"],"URL":"https:\/\/doi.org\/10.3390\/ijerph17062092","relation":{},"ISSN":["1660-4601"],"issn-type":[{"value":"1660-4601","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,3,21]]}}}