{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T04:45:11Z","timestamp":1787028311467,"version":"build-2736575974"},"reference-count":50,"publisher":"MDPI AG","issue":"13","license":[{"start":{"date-parts":[[2020,6,30]],"date-time":"2020-06-30T00:00:00Z","timestamp":1593475200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IJERPH"],"abstract":"<jats:p>Due to the high prevalence of periodontitis, dentists have to face a larger group of patients with periodontally compromised dentitions (PCDs) characterized by pathologic tooth migration and malocclusion. Impression taking in these patients is challenging due to several undercuts and extensive interdental areas (IAs). The aim of this clinical trial was to analyze the ability of analog and digital impression techniques to display the IAs in PCDs. The upper and the lower jaws of 30 patients (n = 60, age: 48\u201387 years) were investigated with one conventional impression (CVI) using polyvinyl siloxane and four digital impressions with intraoral scanners (IOSs), namely True Definition (TRU), Primescan (PRI), CS 3600 (CAR), and TRIOS 3 (TIO). The gypsum models of the CVIs were digitalized using a laboratory scanner. Subsequently, the percentage of the displayed IAs in relation to the absolute IAs was calculated for the five impression techniques in a three-dimensional measuring software. Significant differences were observed among the impression techniques (except between PRI and CAR, p-value &lt; 0.05). TRU displayed the highest percentage of IAs, followed by PRI, CAR, TIO, and CVI. The results indicated that the IOSs are superior to CVI regarding the ability to display the IAs in PCDs.<\/jats:p>","DOI":"10.3390\/ijerph17134725","type":"journal-article","created":{"date-parts":[[2020,6,30]],"date-time":"2020-06-30T16:06:54Z","timestamp":1593533214000},"page":"4725","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":36,"title":["Digital versus Conventional Impression Taking Focusing on Interdental Areas: A Clinical Trial"],"prefix":"10.3390","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4747-824X","authenticated-orcid":false,"given":"Maximiliane Amelie","family":"Schlenz","sequence":"first","affiliation":[{"name":"Dental Clinic, Department of Prosthodontics, Justus Liebig University, 35392 Giessen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Victoria","family":"Schubert","sequence":"additional","affiliation":[{"name":"Dental Clinic, Department of Prosthodontics, Justus Liebig University, 35392 Giessen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Schmidt","sequence":"additional","affiliation":[{"name":"Dental Clinic, Department of Prosthodontics, Justus Liebig University, 35392 Giessen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bernd","family":"W\u00f6stmann","sequence":"additional","affiliation":[{"name":"Dental Clinic, Department of Prosthodontics, Justus Liebig University, 35392 Giessen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sabine","family":"Ruf","sequence":"additional","affiliation":[{"name":"Dental Clinic, Department of Orthodontics, Justus Liebig University, 35392 Giessen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katharina","family":"Klaus","sequence":"additional","affiliation":[{"name":"Dental Clinic, Department of Orthodontics, Justus Liebig University, 35392 Giessen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2020,6,30]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Jordan, R.A., Bodechtel, C., Hertrampf, K., Hoffmann, T., Kocher, T., Nitschke, I., Schiffner, U., Stark, H., Zimmer, S., and Micheelis, W. (2014). The Fifth German Oral Health Study (F\u00fcnfte Deutsche Mundgesundheitsstudie, DMS V)\u2014Rationale, design, and methods. BMC Oral Health., 14.","DOI":"10.1186\/1472-6831-14-161"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1111\/j.1600-0757.2009.00326.x","article-title":"Epidemiologic patterns of chronic and aggressive periodontitis","volume":"53","author":"Demmer","year":"2010","journal-title":"Periodontol. 2000"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1111\/prd.12145","article-title":"Periodontitis prevalence in adults >\/= 65 years of age, in the USA","volume":"72","author":"Eke","year":"2016","journal-title":"Periodontol. 2000"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"492","DOI":"10.1111\/j.1600-051X.1997.tb00217.x","article-title":"A study on factors associated with pathologic tooth migration","volume":"24","author":"Carrasquer","year":"1997","journal-title":"J. Clin. Periodontol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1902\/jop.2005.76.6.859","article-title":"Pathologic tooth migration","volume":"76","author":"Brunsvold","year":"2005","journal-title":"J. Periodontol."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Melsen, B. (2012). Adult Orthodontics, Wiley-Blackwell.","DOI":"10.1002\/9781118702925"},{"key":"ref_7","unstructured":"Proffit, W., Fields, H., and Sarver, D. (2013). Contemporary Orthodontics, Elsevier Mosby. [5th ed.]."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"883","DOI":"10.2319\/011316-37R.1","article-title":"Forces and moments delivered by novel, thinner PET-G aligners during labiopalatal bodily movement of a maxillary central incisor: An in vitro study","volume":"86","author":"Elkholy","year":"2016","journal-title":"Angle Orthod."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1016\/j.ajodo.2016.08.020","article-title":"Forces and moments applied during derotation of a maxillary central incisor with thinner aligners: An in-vitro study","volume":"151","author":"Elkholy","year":"2017","journal-title":"Am. J. Orthod. Dentofac. Orthop."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1093\/ejo\/cju083","article-title":"Periodontal health during clear aligners treatment: A systematic review","volume":"37","author":"Rossini","year":"2015","journal-title":"Eur. J. Orthod."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"404","DOI":"10.4103\/1305-7456.163218","article-title":"Periodontal health status in patients treated with the Invisalign\u00ae system and fixed orthodontic appliances: A 3 months clinical and microbiological evaluation","volume":"9","author":"Levrini","year":"2015","journal-title":"Eur. J. Dent."},{"key":"ref_12","first-page":"13","article-title":"Clear aligner: An efficient, esthetic, and comfortable option for an adult patient","volume":"8","author":"Kim","year":"2007","journal-title":"World J. Orthod."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1111\/adj.12480","article-title":"Clear aligners in orthodontic treatment","volume":"62","author":"Weir","year":"2017","journal-title":"Aust. Dent. J."},{"key":"ref_14","unstructured":"Boyd, R., Miller, R., and Vlaskalic, V. (2000). The Invisalign System in Adult Orthodontics: Mild Crowding and Space Closure Cases. J. Clin. Orthod., 203\u2013212."},{"key":"ref_15","unstructured":"Kharbanda, O.P. (2020). Orthodontics: Diagnosis of & Management of Malocclusion & Dentofacial Deformities, Elsevier. [3rd ed.]."},{"key":"ref_16","unstructured":"Bouchez, R. (2010). Clinical Success in Invisalign Orthodontic Treatment, Quintessenz Publishing. [1st ed.]."},{"key":"ref_17","unstructured":"Schweiger, J., and Kieschnick, A. (2017). CAD\/CAM in Der Digitalen Zahnheilkunde, Teamwork Media GmbH. [1st ed.]."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/j.jdent.2016.10.002","article-title":"A new method for assessing the accuracy of full arch impressions in patients","volume":"55","author":"Kuhr","year":"2016","journal-title":"J. Dent."},{"key":"ref_19","first-page":"9","article-title":"In-vitro evaluation of the accuracy of conventional and digital methods of obtaining full-arch dental impressions","volume":"46","author":"Ender","year":"2015","journal-title":"Quintessence Int."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/S0022-3913(13)60028-1","article-title":"Accuracy of complete-arch dental impressions: A new method of measuring trueness and precision","volume":"109","author":"Ender","year":"2013","journal-title":"J. Prosthet. Dent."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1687","DOI":"10.1007\/s00784-013-1132-y","article-title":"Accuracy of full-arch scans using intraoral scanners","volume":"18","author":"Patzelt","year":"2014","journal-title":"Clin. Oral Investig."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1487","DOI":"10.1007\/s00784-015-1626-x","article-title":"A new method for the evaluation of the accuracy of full-arch digital impressions in vitro","volume":"20","author":"Edelhoff","year":"2016","journal-title":"Clin. Oral Investig."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1360","DOI":"10.1111\/clr.12994","article-title":"Digital vs. conventional full-arch implant impressions: A comparative study","volume":"28","author":"Amin","year":"2017","journal-title":"Clin. Oral Implant. Res."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1016\/j.prosdent.2016.09.024","article-title":"Evaluation of the accuracy of 7 digital scanners: An in vitro analysis based on 3-dimensional comparisons","volume":"118","author":"Renne","year":"2017","journal-title":"J. Prosthet. Dent."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1007\/s00784-019-02965-2","article-title":"Accuracy of full-arch digital impressions: An in vitro and in vivo comparison","volume":"24","author":"Keul","year":"2020","journal-title":"Clin. Oral Investig."},{"key":"ref_26","first-page":"11","article-title":"Accuracy of complete- and partial-arch impressions of actual intraoral scanning systems in vitro","volume":"22","author":"Ender","year":"2019","journal-title":"Int. J. Comput. Dent."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1111\/jerd.12485","article-title":"Evaluation of the trueness and precision of complete arch digital impressions on a human maxilla using seven different intraoral digital impression systems and a laboratory scanner","volume":"31","author":"Mennito","year":"2019","journal-title":"J. Esthet. Restor. Dent."},{"key":"ref_28","first-page":"11","article-title":"Full arch scans: Conventional versus digital impressions--an in-vitro study","volume":"14","author":"Ender","year":"2011","journal-title":"Int. J. Comput. Dent."},{"key":"ref_29","first-page":"131","article-title":"In vitro comparison of analog versus digital impressions of the periodontally compromised dentition focused on interdental areas","volume":"22","author":"Schlenz","year":"2019","journal-title":"Int. J. Comput. Dent."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1093\/ejo\/cjw033","article-title":"Validity and reliability of intraoral scanners compared to conventional gypsum models measurements: A systematic review","volume":"38","author":"Aragon","year":"2016","journal-title":"Eur. J. Orthod."},{"key":"ref_31","first-page":"41","article-title":"Accuracy and efficiency of full-arch digitalization and 3D printing: A comparison between desktop model scanners, an intraoral scanner, a CBCT model scan, and stereolithographic 3D printing","volume":"48","author":"Wesemann","year":"2017","journal-title":"Quintessence Int."},{"key":"ref_32","first-page":"151","article-title":"Accuracy of full-arch scans using intraoral and extraoral scanners: An in vitro study using a new method of evaluation","volume":"20","author":"Muallah","year":"2017","journal-title":"Int. J. Comput. Dent."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1007\/s00056-017-0103-3","article-title":"Precision of guided scanning procedures for full-arch digital impressions in vivo","volume":"78","author":"Zimmermann","year":"2017","journal-title":"J. Orofac. Orthop."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"4103232","DOI":"10.1155\/2018\/4103232","article-title":"Computerized Casts for Orthodontic Purpose Using Powder-Free Intraoral Scanners: Accuracy, Execution Time, and Patient Feedback","volume":"2018","author":"Sfondrini","year":"2018","journal-title":"BioMed Res. Int."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"1124","DOI":"10.1902\/jop.1998.69.10.1124","article-title":"A classification system for loss of papillary height","volume":"69","author":"Nordland","year":"1998","journal-title":"J. Periodontol."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"27","DOI":"10.11607\/ijp.4976","article-title":"Intraoral Scanning Systems: Need for Maintenance","volume":"30","author":"Rehmann","year":"2017","journal-title":"Int. J. Prosthodont."},{"key":"ref_37","first-page":"343","article-title":"Impact of digital intraoral scan strategies on the impression accuracy using the TRIOS Pod scanner","volume":"47","author":"Ender","year":"2016","journal-title":"Quintessence Int."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"5189761","DOI":"10.1155\/2018\/5189761","article-title":"Trueness and Precision of Three-Dimensional Digitizing Intraoral Devices","volume":"2018","author":"Mutwalli","year":"2018","journal-title":"Int. J. Dent."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1016\/j.jpor.2019.06.006","article-title":"Torsion and linear accuracy in intraoral scans obtained with different scanning principles","volume":"64","author":"Schmidt","year":"2020","journal-title":"J. Prosthodont. Res."},{"key":"ref_40","first-page":"11","article-title":"Influence of scanning strategies on the accuracy of digital intraoral scanning systems","volume":"16","author":"Ender","year":"2013","journal-title":"Int. J. Comput. Dent."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"375","DOI":"10.11607\/ijp.5781","article-title":"Effect of Software Version on the Accuracy of an Intraoral Scanning Device","volume":"31","author":"Haddadi","year":"2018","journal-title":"Int. J. Prosthodont."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"1445","DOI":"10.1007\/s00784-016-1902-4","article-title":"Accuracy of five intraoral scanners compared to indirect digitalization","volume":"21","author":"Runkel","year":"2017","journal-title":"Clin. Oral Investig."},{"key":"ref_43","doi-asserted-by":"crossref","unstructured":"Ribeiro, P., Herrero-Climent, M., Diaz-Castro, C., Rios-Santos, J.V., Padros, R., Mur, J.G., and Falcao, C. (2018). Accuracy of Implant Casts Generated with Conventional and Digital Impressions-An In Vitro Study. Int. J. Environ. Res. Public Health, 15.","DOI":"10.3390\/ijerph15081599"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1016\/j.jpor.2018.01.003","article-title":"Trueness and precision of digital impressions obtained using an intraoral scanner with different head size in the partially edentulous mandible","volume":"62","author":"Hayama","year":"2018","journal-title":"J. Prosthodont. Res."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"1495","DOI":"10.1007\/s00784-015-1641-y","article-title":"In vivo precision of conventional and digital methods for obtaining quadrant dental impressions","volume":"20","author":"Ender","year":"2016","journal-title":"Clin. Oral Investig."},{"key":"ref_46","first-page":"11","article-title":"Accuracy testing of a new intraoral 3D camera","volume":"12","author":"Mehl","year":"2009","journal-title":"Int. J. Comput. Dent."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"553","DOI":"10.1016\/j.jdent.2010.03.015","article-title":"Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling","volume":"38","author":"Syrek","year":"2010","journal-title":"J. Dent."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1016\/j.prosdent.2014.07.006","article-title":"Influence of dentist experience with scan spray systems used in direct CAD\/CAM impressions","volume":"113","author":"Dehurtevent","year":"2015","journal-title":"J. Prosthet. Dent."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1177\/205016841800700207","article-title":"Powder and Powder-Free Intra-Oral Scanners: Digital Impression Accuracy","volume":"7","author":"Hategan","year":"2018","journal-title":"Prim. Dent. J."},{"key":"ref_50","unstructured":"Tewes, M., and Berner, M. (2019). Device, Method and System for Generating Dynamic Projection Patterns in a Confocal Camera. (Nr. 16\/003,628), U.S. Patent Application."}],"container-title":["International Journal of Environmental Research and Public Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1660-4601\/17\/13\/4725\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T09:45:33Z","timestamp":1760175933000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1660-4601\/17\/13\/4725"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6,30]]},"references-count":50,"journal-issue":{"issue":"13","published-online":{"date-parts":[[2020,7]]}},"alternative-id":["ijerph17134725"],"URL":"https:\/\/doi.org\/10.3390\/ijerph17134725","relation":{},"ISSN":["1660-4601"],"issn-type":[{"value":"1660-4601","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,6,30]]}}}