{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T15:52:27Z","timestamp":1789141947190,"version":"build-2803163510"},"reference-count":28,"publisher":"MDPI AG","issue":"14","license":[{"start":{"date-parts":[[2020,7,16]],"date-time":"2020-07-16T00:00:00Z","timestamp":1594857600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100002347","name":"Bundesministerium f\u00fcr Bildung und Forschung","doi-asserted-by":"publisher","award":["16SV8203"],"award-info":[{"award-number":["16SV8203"]}],"id":[{"id":"10.13039\/501100002347","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IJERPH"],"abstract":"<jats:p>Occupational ergonomics in healthcare is an increasing challenge we have to handle in the near future. Physical assistive systems, so-called exoskeletons, are promising solutions to prevent work-related musculoskeletal disorders (WMSDs). Manual handling like pushing, pulling, holding and lifting during healthcare activities require practical and biomechanical effective assistive devices. In this article, a musculoskeletal-model-based development of an assistive exoskeleton is described for manual patient transfer in the surgery waiting room. For that purpose, kinematic data collected with an experimental set-up reproducing real patient transfer conditions are first used to define the kinetic boundary conditions for the model-based development approach. Model-based analysis reveals significant relief potential in the lower back and shoulder area of the musculoskeletal apparatus. This is corroborated by subjective feedback collected during measurements with real surgery assistants. A shoulder\u2013arm exoskeleton design is then proposed, optimized and evaluated within the same simulation framework. The presented results illustrate the potential for the proposed design to reduce significantly joint compressions and muscle activities in the shoulder complex in the considered patient transfer scenarios.<\/jats:p>","DOI":"10.3390\/ijerph17145140","type":"journal-article","created":{"date-parts":[[2020,7,16]],"date-time":"2020-07-16T10:54:46Z","timestamp":1594896886000},"page":"5140","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":64,"title":["Biomechanical Model-Based Development of an Active Occupational Upper-Limb Exoskeleton to Support Healthcare Workers in the Surgery Waiting Room"],"prefix":"10.3390","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9488-0971","authenticated-orcid":false,"given":"Mark","family":"Tr\u00f6ster","sequence":"first","affiliation":[{"name":"Fraunhofer Institute for Manufacturing Engineering and Automation IPA, Nobelstra\u00dfe 12, 70569 Stuttgart, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Wagner","sequence":"additional","affiliation":[{"name":"Fraunhofer Institute for Manufacturing Engineering and Automation IPA, Nobelstra\u00dfe 12, 70569 Stuttgart, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Felix","family":"M\u00fcller-Graf","sequence":"additional","affiliation":[{"name":"Fraunhofer Institute for Manufacturing Engineering and Automation IPA, Nobelstra\u00dfe 12, 70569 Stuttgart, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christophe","family":"Maufroy","sequence":"additional","affiliation":[{"name":"Fraunhofer Institute for Manufacturing Engineering and Automation IPA, Nobelstra\u00dfe 12, 70569 Stuttgart, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Urs","family":"Schneider","sequence":"additional","affiliation":[{"name":"Fraunhofer Institute for Manufacturing Engineering and Automation IPA, Nobelstra\u00dfe 12, 70569 Stuttgart, Germany"},{"name":"Institute of Industrial Manufacturing and Management IFF, University of Stuttgart, Allmandring 35, 70569 Stuttgart, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Bauernhansl","sequence":"additional","affiliation":[{"name":"Fraunhofer Institute for Manufacturing Engineering and Automation IPA, Nobelstra\u00dfe 12, 70569 Stuttgart, Germany"},{"name":"Institute of Industrial Manufacturing and Management IFF, University of Stuttgart, Allmandring 35, 70569 Stuttgart, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2020,7,16]]},"reference":[{"key":"ref_1","unstructured":"Brenscheidt, S., Siefer, A., Hinnenkamp, H., H\u00fcnefeld, L., L\u00fcck, M., and Kopatz, F. (2020). Arbeitswelt im Wandel: Zahlen\u2013Daten\u2013Fakten, Federal Institute for Occupational Safety and Health."},{"key":"ref_2","unstructured":"Schneider, E., and Irastorza, X. (2010). OSH in Figures: Work-Related Musculoskeletal Disorders in the EU\u2014Facts and Figures, European Agency for Safety and Health at Work."},{"key":"ref_3","first-page":"S4-003","article-title":"Work Related Musculoskeletal Disorders among Nurses: Systematic Review","volume":"4","author":"Narsigan","year":"2014","journal-title":"J. Ergon."},{"key":"ref_4","unstructured":"K\u00f6nig, A.M., Thomas, R.P., Viniol, S., and Mahnken, A.H. (2019, January 22\u201324). Orthopaedic Health Problems with Personal Radiation Protection in Interventional Radiology. Proceedings of the International Joint Conference on Occupational Health for Health Worker, Hamburg, Germany."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Ohlendorf, D., Erbe, C., Imke, H., Nowak, J., Hermanns, I., Ditchen, D., Ellegast, R., and Groneberg, D.A. (2016). Kinematic analysis of work-related musculoskeletal loading of trunk among dentists in Germany. BMC Musculoskelet. Disord., 17.","DOI":"10.1186\/s12891-016-1288-0"},{"key":"ref_6","unstructured":"Luttmann, A., J\u00e4ger, M., Griefahn, B., Caffier, G., Liebers, F., and Steinberg, U. (2003). Preventing Musculoskeletal Disorders in the Workplace, World Health Organization."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1080\/24725838.2019.1709695","article-title":"An Introduction to the Special Issue on Occupational Exoskeletons","volume":"7","author":"Nussbaum","year":"2019","journal-title":"Iise Trans. Occup. Ergon. Hum. Factors"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.robot.2015.10.001","article-title":"Developments in hardware systems of active upper-limb exoskeleton robots: A review","volume":"75","author":"Gopura","year":"2016","journal-title":"J. Robot. Auton. Syst."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Voilque, A., Masood, J., Fauroux, J., Sabourin, L., and Guezet, O. (2019, January 25\u201327). Industrial Exoskeleton Technology: Classification, Structural Analysis, and Structural Complexity Indicator. Proceedings of the 2019 Wearable Robotics Association Conference (WearRAcon), Scottsdale, AZ, USA.","DOI":"10.1109\/WEARRACON.2019.8719395"},{"key":"ref_10","unstructured":"Mast, J. (2020, March 22). Das SoftExo Bereitet den Weg in Eine Ergonomische Zukunft der Manuellen Handhabung. Available online: https:\/\/hunic.com."},{"key":"ref_11","unstructured":"S\u00f6nke, R. (2020, March 22). New Exoskeleton Relieves the Back. Available online: https:\/\/paexo.com\/paexo-back\/?lang=en."},{"key":"ref_12","unstructured":"(2020, January 16). German Bionic Crax X: Erstes Exoskelett Made in German geht in Serie. Available online: https:\/\/www.germanbionic.com\/Presse\/german-bionic-cray-x."},{"key":"ref_13","unstructured":"(2020, January 16). Laevo Exoskeleton: Laevo V2. Available online: http:\/\/en.laevo.nl\/laevo-v2-product-information."},{"key":"ref_14","unstructured":"(2020, January 22). Powered Wear, ATOUN MODEL Y, Assist Suit that Supports the Waist by Moving in Harmony with the Wearer. Available online: http:\/\/atoun.co.jp\/products\/atoun-model-yandhttps:\/\/www.instagram.com\/p\/BsxRXGTnzQ7\/."},{"key":"ref_15","first-page":"236","article-title":"Solving the surgeon ergonomic crisis with surgical exosuit","volume":"32","author":"Shanglei","year":"2016","journal-title":"J. Surg. Endosc."},{"key":"ref_16","unstructured":"(2020, January 22). Laevo | Exoskeletons @Laevobv. Innovative back Supports Using Spring Technology. Available online: https:\/\/twitter.com\/laevobv."},{"key":"ref_17","unstructured":"(2020, February 22). Research Project ExoPflege. BMBF + VDI\/VDE Innovation + Technik GmbH 2019. Available online: https:\/\/www.technik-zum-menschen-bringen.de\/projekte\/exopflege."},{"key":"ref_18","unstructured":"Tr\u00f6ster, M., Schneider, U., Bauernhansl, T., Rasmussen, J., and Andersen, M.S. (2018, January 11\u201312). Simulation Framework for Active Upper Limb Exoskeleton Design Optimization Based on Musculoskeletal Modeling. Proceedings of the 2018 Smart ASSIST, Technische Unterst\u00fctzungssysteme, die die Menschen Wirklich Wollen, Hamburg, Germany."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1016\/S0021-9290(00)00191-3","article-title":"Muscle recruitment by the min\/max criterion: A comparative numerical study","volume":"34","author":"Rasmussen","year":"2001","journal-title":"J. Biomech."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"2139","DOI":"10.1016\/j.jbiomech.2006.10.037","article-title":"In vivo glenohumeral contact forces\u2014measurements in the first patient 7 months postoperatively","volume":"40","author":"Bergmann","year":"2007","journal-title":"J. Biomech."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1007\/s11044-016-9537-4","article-title":"Prediction of ground reaction forces and moments during sports-related movements","volume":"39","author":"Skals","year":"2017","journal-title":"J. Multibody Syst. Dyn."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"167","DOI":"10.4173\/mic.2015.3.4","article-title":"Modeling and Design of a Spring-loaded, Cable-driven, Wearable Exoskeleton for the Upper Extremity","volume":"36","author":"Zhou","year":"2015","journal-title":"J. Modeling Identif. Control"},{"key":"ref_23","first-page":"1","article-title":"Development and simulation of a passive upper extremity orthosis for amyoplasia","volume":"5","author":"Jensen","year":"2018","journal-title":"J. Rehabiliation Assist. Technol. Eng."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1016\/j.robot.2016.12.012","article-title":"A human-centered design optimization approach for robotic exoskeletons through biomechanical simulation","volume":"91","author":"Zhou","year":"2017","journal-title":"J. Robot. Auton. Syst."},{"key":"ref_25","unstructured":"Inose, H., Mohri, S., Arakawa, H., Okui, M., Koide, K., Yamada, Y., Kikutani, I., and Nakamura, T. (June, January 29). Semi-Endoskeleton-Type Waist Assist AB-Wear Suit Equipped with Compressive Force Reduction Mechanism. Proceedings of the International Conference on Robotics and Automation (ICRA), Singapore."},{"key":"ref_26","unstructured":"Wakula, J., Berg, K., Schaub, K., Bruder, R., Glitsch, U., and Ellegast, R.P. (2009). Der Montagespezifische Kraftatlas (BGIA-Report 3\/2009), Deutsche Gesetzliche Unfallversicherung (DGUV)."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"893","DOI":"10.1016\/j.jaad.2018.12.068","article-title":"Pressure ulcers: Prevention and management","volume":"81","author":"Mervis","year":"2019","journal-title":"J. Am. Acad. Dermatol."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1016\/j.procir.2016.05.048","article-title":"JackEx: The new digital manufacturing resource for optimization of exoskeleton-based factory environments","volume":"50","author":"Constantinescu","year":"2016","journal-title":"Procedia CIRP"}],"container-title":["International Journal of Environmental Research and Public Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1660-4601\/17\/14\/5140\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T09:49:05Z","timestamp":1760176145000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1660-4601\/17\/14\/5140"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7,16]]},"references-count":28,"journal-issue":{"issue":"14","published-online":{"date-parts":[[2020,7]]}},"alternative-id":["ijerph17145140"],"URL":"https:\/\/doi.org\/10.3390\/ijerph17145140","relation":{},"ISSN":["1660-4601"],"issn-type":[{"value":"1660-4601","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,7,16]]}}}