{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T22:32:54Z","timestamp":1788474774869,"version":"build-2803163510"},"reference-count":30,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2021,5,30]],"date-time":"2021-05-30T00:00:00Z","timestamp":1622332800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IJERPH"],"abstract":"<jats:p>Historically, reducing aerosol-based transmission of respired viruses in indoor environments has been of importance for controlling influenza viruses and common-cold rhinoviruses. The present public health emergency associated with SARS-CoV-2 makes this topic critically important. Yet to be tested is the potential effectiveness of simple interventions that create an isolation zone (IZ) for a suspected\/confirmed sick or sensitive person requiring quarantine. The intent in existing homes is to find a practical means to mitigate exposure to airborne contaminants. In creating an IZ in an occupied single-family home in the study, four simple strategies were tested. The test configurations were: (1) IZ windows closed with IZ bathroom exhaust ventilation fan off, (2) IZ windows closed with IZ exhaust fan on, (3) IZ window open with IZ exhaust fan off, and (4) IZ window open with IZ exhaust fan on. Incense-generated fine particulate matter (PM2.5) was used as a marker for virus transmission. The measured transfer of PM2.5 from the IZ into the main zone (MZ) of the house enabled us to determine the relative effectiveness of four containment strategies. Collectively, the data from pressure differential (across zones) and PM2.5 measurements suggested that the best containment strategy was achieved through continuously operating the bathroom exhaust fan while keeping the windows closed in the IZ (configuration 2). Interventions using open windows were found to be less reliable, due to variability in wind speed and direction, resulting in an unpredictable and sometimes detrimental pressure differential in the IZ with reference to MZ. Our findings strongly suggest a simple IZ exhaust ventilation strategy has the potential for mitigating the risk from the airborne spread of contaminants, such as SARS-CoV-2.<\/jats:p>","DOI":"10.3390\/ijerph18115880","type":"journal-article","created":{"date-parts":[[2021,5,31]],"date-time":"2021-05-31T00:22:15Z","timestamp":1622420535000},"page":"5880","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Mitigation of Airborne Contaminant Spread through Simple Interventions in an Occupied Single-Family Home"],"prefix":"10.3390","volume":"18","author":[{"given":"Tanvir R.","family":"Khan","sequence":"first","affiliation":[{"name":"FSEC Energy Research Center, University of Central Florida, Cocoa, FL 32922, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Danny S.","family":"Parker","sequence":"additional","affiliation":[{"name":"FSEC Energy Research Center, University of Central Florida, Cocoa, FL 32922, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charles","family":"Withers","sequence":"additional","affiliation":[{"name":"FSEC Energy Research Center, University of Central Florida, Cocoa, FL 32922, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2021,5,30]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1111\/ina.12697","article-title":"Recognizing and controlling airborne transmission of SARS-CoV-2 in indoor environments","volume":"30","author":"Allen","year":"2020","journal-title":"Indoor Air"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"7704","DOI":"10.1021\/acsnano.0c04596","article-title":"Back to normal: An old physics route to reduce SARS-CoV-2 transmission in indoor spaces","volume":"14","author":"Kaminer","year":"2020","journal-title":"ACS Nano"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1111\/ina.12751","article-title":"Transmission of SARS-CoV-2 by inhalation of respiratory aerosol in the Skagit Valley Chorale superspreading event","volume":"31","author":"Miller","year":"2020","journal-title":"Indoor Air"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"105730","DOI":"10.1016\/j.envint.2020.105730","article-title":"Airborne transmission of SARS-CoV-2: The world should face the reality","volume":"139","author":"Morawska","year":"2020","journal-title":"Environ. Int."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"105832","DOI":"10.1016\/j.envint.2020.105832","article-title":"How can airborne transmission of COVID-19 indoors be minimised?","volume":"142","author":"Morawska","year":"2020","journal-title":"Environ. Int."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1422","DOI":"10.1126\/science.abc6197","article-title":"Reducing transmission of SARS-CoV-2","volume":"368","author":"Prather","year":"2020","journal-title":"Science"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1126\/science.abf0521","article-title":"Airborne transmission of SARS-CoV-2","volume":"370","author":"Prather","year":"2020","journal-title":"Science"},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Asadi, S., Bouvier, N., Wexler, A.S., and Ristenpart, W.D. (2020). The coronavirus pandemic and aerosols: Does COVID-19 transmit via expiratory particles?. Aerosol Science & Technology, Taylor & Francis.","DOI":"10.1080\/02786826.2020.1749229"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1038\/s41423-020-0407-x","article-title":"COVID-19: A new challenge for human beings","volume":"17","author":"Yang","year":"2020","journal-title":"Cell. Mol. Immunol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1038\/s41467-020-16670-2","article-title":"Detection of air and surface contamination by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in hospital rooms of infected patients","volume":"11","author":"Chia","year":"2020","journal-title":"Nat. Commun."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1038\/s41586-020-2271-3","article-title":"Aerodynamic analysis of SARS-CoV-2 in two Wuhan hospitals","volume":"582","author":"Liu","year":"2020","journal-title":"Nature"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"106859","DOI":"10.1016\/j.buildenv.2020.106859","article-title":"Short-range airborne route dominates exposure of respiratory infection during close contact","volume":"176","author":"Chen","year":"2020","journal-title":"Build. Environ."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1001\/jama.2020.12458","article-title":"Airborne transmission of SARS-CoV-2: Theoretical considerations and available evidence","volume":"324","author":"Klompas","year":"2020","journal-title":"Jama"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1016\/j.jinf.2020.03.040","article-title":"Household transmission of SARS-CoV-2","volume":"81","author":"Wang","year":"2020","journal-title":"J. Infect."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"e2031756","DOI":"10.1001\/jamanetworkopen.2020.31756","article-title":"Household Transmission of SARS-CoV-2: A Systematic Review and Meta-analysis","volume":"3","author":"Madewell","year":"2020","journal-title":"JAMA Netw. Open"},{"key":"ref_16","unstructured":"Ashrae, A. (2017). ANSI\/ASHRAE\/ASHE Standard 170\u20132013, Ventilation of Health Care Facilities, American Society of Heating, Refrigerating Air-Conditioning Engineers, Inc."},{"key":"ref_17","unstructured":"Martin, E., Khan, T., Chasar, D., Sonne, J., Rosenberg, S., Antonopoulos, C., Metzger, C., Chan, W.R., Singer, B., and Lubliner, M. (2020). Characterization of Mechanical Ventilation Systems in New US Homes: What types of systems are out there and are they functioning as intended?. 2020 Summer Study on Energy Efficiency in Buildings, ACEEE."},{"key":"ref_18","unstructured":"Sonne, J.K., Withers, C., and Vieira, R. (2015). Investigation of the Effectiveness and Failure Rates of Whole-House Mechanical Ventilation Systems in Florida, Florida Solar Energy Center. FSEC-CR-2002-15."},{"key":"ref_19","unstructured":"Lubliner, M.K.R., Devine, J., and Gordon, A. (2002). Washington State Residential and Indoor Air Quality Code (VIAQ): Whole House Ventilation Systems Field Research Report, ACEEE."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"S2295","DOI":"10.21037\/jtd.2018.01.24","article-title":"Ventilation control for airborne transmission of human exhaled bio-aerosols in buildings","volume":"10","author":"Qian","year":"2018","journal-title":"J. Thorac. Dis."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Fehr, A.R., and Perlman, S. (2015). Coronaviruses: An overview of their replication and pathogenesis. Coronaviruses. Methods in Molecular Biology, Humana Press.","DOI":"10.1007\/978-1-4939-2438-7_1"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"3730","DOI":"10.1021\/acs.est.0c01102","article-title":"An imperative need for research on the role of environmental factors in transmission of novel coronavirus (COVID-19)","volume":"54","author":"Qu","year":"2020","journal-title":"Environ. Sci. Technol."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"139489","DOI":"10.1016\/j.scitotenv.2020.139489","article-title":"SARS-CoV-2 infection and air pollutants: Correlation or causation?","volume":"734","author":"Ranzieri","year":"2020","journal-title":"Sci. Total Environ."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"141532","DOI":"10.1016\/j.scitotenv.2020.141532","article-title":"Particulate matter and SARS-CoV-2: A possible model of COVID-19 transmission","volume":"750","author":"Tung","year":"2021","journal-title":"Sci. Total Environ."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"3861","DOI":"10.5194\/gmd-10-3861-2017","article-title":"Evaluation of five dry particle deposition parameterizations for incorporation into atmospheric transport models","volume":"10","author":"Khan","year":"2017","journal-title":"Geosci. Model Dev."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1657","DOI":"10.3201\/eid1211.060426","article-title":"Review of aerosol transmission of influenza A virus","volume":"12","author":"Tellier","year":"2006","journal-title":"Emerg. Infect. Dis."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"139356","DOI":"10.1016\/j.scitotenv.2020.139356","article-title":"Impact of building ventilation systems and habitual indoor incense burning on SARS-CoV-2 virus transmissions in Middle Eastern countries","volume":"733","author":"Amoatey","year":"2020","journal-title":"Sci. Total Environ."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"5309","DOI":"10.1021\/acs.est.0c02041","article-title":"Letter to the editor regarding: \u201can imperative need for research on the role of environmental factors in transmission of novel coronavirus (COVID-19)\u201d\u2014Secondhand and thirdhand smoke as potential sources of COVID-19","volume":"54","author":"Merianos","year":"2020","journal-title":"Environ. Sci. Technol."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1007\/s10311-020-01069-8","article-title":"Electrostatic fine particles emitted from laser printers as potential vectors for airborne transmission of COVID-19","volume":"19","author":"He","year":"2020","journal-title":"Environ. Chem. Lett."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1111\/ina.12425","article-title":"Quantifying fine particle emission events from time-resolved measurements: Method description and application to 18 California low-income apartments","volume":"28","author":"Chan","year":"2018","journal-title":"Indoor Air."}],"container-title":["International Journal of Environmental Research and Public Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1660-4601\/18\/11\/5880\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T06:09:06Z","timestamp":1760162946000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1660-4601\/18\/11\/5880"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,5,30]]},"references-count":30,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2021,6]]}},"alternative-id":["ijerph18115880"],"URL":"https:\/\/doi.org\/10.3390\/ijerph18115880","relation":{},"ISSN":["1660-4601"],"issn-type":[{"value":"1660-4601","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,5,30]]}}}