{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,2]],"date-time":"2025-11-02T11:16:45Z","timestamp":1762082205726,"version":"build-2065373602"},"reference-count":8,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2022,12,26]],"date-time":"2022-12-26T00:00:00Z","timestamp":1672012800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IJERPH"],"abstract":"<jats:p>There are reports documenting that electromagnetic waves generated by deep brain stimulation devices can interfere with cardiac pacemakers. This might be even a life-threatening problem in cardiac pacemaker-dependent patients. Herein, we present a case report on a patient with bilaterally implanted deep brain stimulation devices, who concomitantly had the indications for permanent cardiac pacing. The report shows that a leadless AV pacemaker may be a safe and reasonable option in these cases.<\/jats:p>","DOI":"10.3390\/ijerph20010388","type":"journal-article","created":{"date-parts":[[2022,12,27]],"date-time":"2022-12-27T04:42:47Z","timestamp":1672116167000},"page":"388","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Leadless AV Pacemaker in Patient with Complete Heart Block and Bilaterally Implanted Two Deep Brain Stimulators Can Be Safe Therapeutic Option"],"prefix":"10.3390","volume":"20","author":[{"given":"J\u0119drzej","family":"Michalik","sequence":"first","affiliation":[{"name":"Department of Cardiology and Interventional Angiology, Kashubian Center for Heart and Vascular Diseases, Pomeranian Hospitals, 84-200 Wejherowo, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jonasz","family":"Kozielski","sequence":"additional","affiliation":[{"name":"Department of Cardiology and Interventional Angiology, Kashubian Center for Heart and Vascular Diseases, Pomeranian Hospitals, 84-200 Wejherowo, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1279-3370","authenticated-orcid":false,"given":"Mateusz","family":"W\u0119clewicz","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Copernicus Hospital, 80-803 Gda\u0144sk, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roman","family":"Moroz","sequence":"additional","affiliation":[{"name":"Department of Cardiology and Interventional Angiology, Kashubian Center for Heart and Vascular Diseases, Pomeranian Hospitals, 84-200 Wejherowo, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maciej","family":"Sterli\u0144ski","sequence":"additional","affiliation":[{"name":"1st Department of Heart Arrhythmia, National Institute of Cardiology, 04-628 Warsaw, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0367-4014","authenticated-orcid":false,"given":"Marek","family":"Szo\u0142kiewicz","sequence":"additional","affiliation":[{"name":"Department of Cardiology and Interventional Angiology, Kashubian Center for Heart and Vascular Diseases, Pomeranian Hospitals, 84-200 Wejherowo, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2022,12,26]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1458","DOI":"10.1161\/CIRCULATIONAHA.116.025037","article-title":"Permanent Leadless Cardiac Pacemaker Therapy: A Comprehensive Review","volume":"135","author":"Tjong","year":"2017","journal-title":"Circulation"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Katarzy\u0144ska-Szyma\u0144ska, A., Chmielewska-Michalak, L., Grymuza, M., Ciep\u0142ucha, A., Kowalski, O., and Mitkowski, P. (2022). Effectiveness of atrioventricular synchrony in patient with Micra AV after the first implantation in middle-eastern Europe. Kardiol. Pol., online ahead of print.","DOI":"10.33963\/KP.a2022.0231"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/j.parkreldis.2021.04.018","article-title":"Coexistence of deep brain stimulators and cardiac implantable electronic devices: A systematic review of safety","volume":"88","author":"Akhoundi","year":"2021","journal-title":"Park. Relat. Disord."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"3427","DOI":"10.1093\/eurheartj\/ehab364","article-title":"ESC Scientific Document Group. 2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy","volume":"42","author":"Glikson","year":"2021","journal-title":"Eur. Heart J."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1016\/j.parkreldis.2020.10.018","article-title":"Interference of subcutaneous implantable cardioverter defibrillator by deep brain stimulation","volume":"81","author":"Nayak","year":"2020","journal-title":"Park. Relat. Disord."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/j.ijcard.2016.08.161","article-title":"Leadless cardiac pacemaker implant in a patient with two deep brain stimulators: A peaceful cohabitation beyond prejudices","volume":"223","author":"Bongiorni","year":"2016","journal-title":"Int. J. Cardiol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"834","DOI":"10.1093\/europace\/eup117","article-title":"Implantation of a pacemaker in a patient with severe Parkinson\u2019s disease and a pre-existing bilateral deep brain stimulator","volume":"11","author":"Ashino","year":"2009","journal-title":"Europace"},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"Michalik, J., D\u0105browska-Kugacka, A., Kosmalska, K., Moroz, R., Kot, A., Lewicka, E., and Szo\u0142kiewicz, M. (2021). Hemodynamic effects of permanent His bundle pacing compared to right ventricular pacing assessed by two-dimensional speckle-tracking echocardiography. Int. J. Environ. Res. Public Health, 18.","DOI":"10.3390\/ijerph182111721"}],"container-title":["International Journal of Environmental Research and Public Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1660-4601\/20\/1\/388\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T01:51:58Z","timestamp":1760147518000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1660-4601\/20\/1\/388"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12,26]]},"references-count":8,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,1]]}},"alternative-id":["ijerph20010388"],"URL":"https:\/\/doi.org\/10.3390\/ijerph20010388","relation":{},"ISSN":["1660-4601"],"issn-type":[{"type":"electronic","value":"1660-4601"}],"subject":[],"published":{"date-parts":[[2022,12,26]]}}}