{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T19:47:36Z","timestamp":1792180056806,"version":"4.4.0"},"reference-count":141,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2015,12,4]],"date-time":"2015-12-04T00:00:00Z","timestamp":1449187200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000006","name":"Office of Naval Research","doi-asserted-by":"publisher","award":["601152N.0000.000.A1308"],"award-info":[{"award-number":["601152N.0000.000.A1308"]}],"id":[{"id":"10.13039\/100000006","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IJMS"],"abstract":"<jats:p>Intracranial pressure (ICP) measurements are essential in evaluation and treatment of neurological disorders such as subarachnoid and intracerebral hemorrhage, ischemic stroke, hydrocephalus, meningitis\/encephalitis, and traumatic brain injury (TBI). The techniques of ICP monitoring have evolved from invasive to non-invasive\u2014with both limitations and advantages. Some limitations of the invasive methods include short-term monitoring, risk of infection, restricted mobility of the subject, etc. The invasiveness of a method limits the frequency of ICP evaluation in neurological conditions like hydrocephalus, thus hampering the long-term care of patients with compromised ICP. Thus, there has been substantial interest in developing noninvasive techniques for assessment of ICP. Several approaches were reported, although none seem to provide a complete solution due to inaccuracy. ICP measurements are fundamental for immediate care of TBI patients in the acute stages of severe TBI injury. In severe TBI, elevated ICP is associated with mortality or poor clinical outcome. ICP monitoring in conjunction with other neurological monitoring can aid in understanding the pathophysiology of brain damage. This review article presents: (a) the significance of ICP monitoring; (b) ICP monitoring methods (invasive and non-invasive); and (c) the role of ICP monitoring in the management of brain damage, especially TBI.<\/jats:p>","DOI":"10.3390\/ijms161226146","type":"journal-article","created":{"date-parts":[[2015,12,9]],"date-time":"2015-12-09T07:06:30Z","timestamp":1449644790000},"page":"28979-28997","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":114,"title":["Advances in Intracranial Pressure Monitoring and Its Significance in Managing Traumatic Brain Injury"],"prefix":"10.3390","volume":"16","author":[{"given":"Usmah","family":"Kawoos","sequence":"first","affiliation":[{"name":"Department of NeuroTrauma, Naval Medical Research Center, Silver Spring, MD 20910, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard","family":"McCarron","sequence":"additional","affiliation":[{"name":"Department of NeuroTrauma, Naval Medical Research Center, Silver Spring, MD 20910, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charles","family":"Auker","sequence":"additional","affiliation":[{"name":"Department of NeuroTrauma, Naval Medical Research Center, Silver Spring, MD 20910, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mikulas","family":"Chavko","sequence":"additional","affiliation":[{"name":"Department of NeuroTrauma, Naval Medical Research Center, Silver Spring, MD 20910, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2015,12,4]]},"reference":[{"key":"ref_1","first-page":"798","article-title":"Intracranial pressure monitoring: Concepts in evaluation and measurement","volume":"23","author":"Baral","year":"2007","journal-title":"Pak. J. Med. Sci."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Oestern, H.J., Trentz, O., and Uranues, S. (2011). Head, Thoracic, Abdominal, and Vascular Injuries: Trauma Surgery I, Springer.","DOI":"10.1007\/978-3-540-88122-3"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1213\/01.ane.0000297296.52006.8e","article-title":"Monitoring intracranial pressure in traumatic brain injury","volume":"106","author":"Smith","year":"2008","journal-title":"Anesth. Analg."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1007\/BF01618093","article-title":"Analysis of intracranial pressure","volume":"8","author":"Doyle","year":"1992","journal-title":"J. Clin. Monit."},{"key":"ref_5","unstructured":"Campbell, W.W., and DeJong, R.N. (2005). Dejong's the Neurologic Examination, Lippincott Williams & Wilkins."},{"key":"ref_6","unstructured":"Carlson, K.K. (2008). Aacn Advanced Critical Care Nursing, Saunders."},{"key":"ref_7","unstructured":"Wiegand, D.J.L.-M. (2013). Aacn Procedure Manual for Critical Care, Elsevier Health Sciences."},{"key":"ref_8","unstructured":"Brain Trauma Foundation, American Association of Neurological Surgeons, and Congress of Neurological Surgeons (2007). Guidelines for the management of severe traumatic brain injury. J. Neurotrauma, 24, S1\u2013S106."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"72","DOI":"10.3171\/jns.1989.71.1.0072","article-title":"Cerebral blood flow and metabolism in severely head-injured children. Part 2: Autoregulation","volume":"71","author":"Muizelaar","year":"1989","journal-title":"J. Neurosurg."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"E2","DOI":"10.3171\/FOC.2008.25.10.E2","article-title":"Continuous monitoring of cerebrovascular pressure reactivity in patients with head injury","volume":"25","author":"Zweifel","year":"2008","journal-title":"Neurosurg. Focus"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"813","DOI":"10.1136\/jnnp.2003.033126","article-title":"Monitoring and interpretation of intracranial pressure","volume":"75","author":"Czosnyka","year":"2004","journal-title":"J. Neurol. Neurosurg. Psychiatry"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1080\/02688699943097","article-title":"A comparative study of the spiegelberg compliance device with a manual volume-injection method: A clinical evaluation in patients with hydrocephalus","volume":"13","author":"Piper","year":"1999","journal-title":"Br. J. Neurosurg."},{"key":"ref_13","unstructured":"Gowers, W.R., and Taylor, J. (1892). A Manual of Diseases of the Nervous System, J&A Churchill."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"E10","DOI":"10.3171\/foc.2007.22.4.12","article-title":"Continuous intracranial pressure monitoring via the shunt reservoir to assess suspected shunt malfunction in adults with hydrocephalus","volume":"22","author":"Geocadin","year":"2007","journal-title":"Neurosurg. Focus"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1097\/00003246-198606000-00002","article-title":"Influence of hypothermia, barbiturate therapy, and intracranial pressure monitoring on morbidity and mortality after near-drowning","volume":"14","author":"Bohn","year":"1986","journal-title":"Crit. Care Med."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1111\/j.1442-200X.1990.tb00856.x","article-title":"Continuous monitoring of intracranial pressure in reye\u2019s syndrome\u20145 Years experience","volume":"32","author":"Chi","year":"1990","journal-title":"Acta Paediatr. Jpn. Overseas Ed."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1590\/S0004-282X2003000300010","article-title":"Intraventricular pressure monitoring in patients with thalamic and ganglionic hemorrhages","volume":"61","author":"Hamani","year":"2003","journal-title":"Arq. Neuro-Psiquiatr."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Nabeta, H.W., Bahr, N.C., Rhein, J., Fossland, N., Kiragga, A.N., Meya, D.B., Dunlop, S.J., and Boulware, D.R. (2014). Accuracy of noninvasive intraocular pressure or optic nerve sheath diameter measurements for predicting elevated intracranial pressure in cryptococcal meningitis. Open Forum Infect. Dis., 1.","DOI":"10.1093\/ofid\/ofu093"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1097\/00000542-200302000-00010","article-title":"Intracranial pressure and cerebral hemodynamic in patients with cerebral tumors: A randomized prospective study of patients subjected to craniotomy in propofol-fentanyl, isoflurane-fentanyl, or sevoflurane-fentanyl anesthesia","volume":"98","author":"Petersen","year":"2003","journal-title":"Anesthesiology"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1007\/s00701-008-1580-3","article-title":"Metabolic failure precedes intracranial pressure rises in traumatic brain injury: A microdialysis study","volume":"150","author":"Belli","year":"2008","journal-title":"Acta Neurochir."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1917","DOI":"10.1001\/jama.2014.3979","article-title":"Trends in visits for traumatic brain injury to emergency departments in the united states","volume":"311","author":"Marin","year":"2014","journal-title":"JAMA"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1097\/ACO.0b013e32834458da","article-title":"Traumatic brain injury in modern war","volume":"24","author":"Ling","year":"2011","journal-title":"Curr. Opin. Anaesthesiol."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1097\/00001199-200609000-00004","article-title":"Military tbi during the iraq and afghanistan wars","volume":"21","author":"Warden","year":"2006","journal-title":"J. Head Trauma Rehabil."},{"key":"ref_24","first-page":"131","article-title":"Continuous intracranial manometry; importance of the method and first results","volume":"84","author":"Guillaume","year":"1951","journal-title":"Rev. Neurol."},{"key":"ref_25","first-page":"1","article-title":"Continuous recording and control of ventricular fluid pressure in neurosurgical practice","volume":"36","author":"Lundberg","year":"1960","journal-title":"Acta Psychiatr. Scand. Suppl."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1001\/archneurpsyc.1955.02330080043012","article-title":"Choroid plexus and arterial pulsation of cerebrospinal fluid; demonstration of the choroid plexuses as a cerebrospinal fluid pump","volume":"73","author":"Bering","year":"1955","journal-title":"AMA Arch. Neurol. Psychiatry"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1152\/ajplegacy.1951.165.2.334","article-title":"Studies on diffusion respiration. Ix. Effect of diffusion respiration and high concentrations of CO2 on cerebrospinal fluid pressure of anesthetized dogs","volume":"165","author":"Goldensohn","year":"1951","journal-title":"Am. J. Physiol."},{"key":"ref_28","first-page":"44","article-title":"Clinical evaluation of the codman microsensor intracranial pressure monitoring system","volume":"71","author":"Fernandes","year":"1998","journal-title":"Acta Neurochir. Suppl."},{"key":"ref_29","first-page":"927","article-title":"A clinical study of parenchymal and subdural miniature strain-gauge transducers for monitoring intracranial pressure","volume":"39","author":"Gray","year":"1996","journal-title":"Neurosurgery"},{"key":"ref_30","first-page":"111","article-title":"Use of fiber-optic pressure transducer for intracranial pressure measurements: A preliminary report","volume":"17","author":"Vos","year":"1988","journal-title":"Heart Lung"},{"key":"ref_31","first-page":"3689","article-title":"Epidural intracranial pressure measurement in rats using a fiber-optic pressure transducer","volume":"62","author":"Murtha","year":"2012","journal-title":"J. Vis. Exp."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"74","DOI":"10.3171\/JNS\/2008\/108\/01\/0074","article-title":"Combined internal uncusectomy and decompressive craniectomy for the treatment of severe closed head injury: Experience with 80 cases","volume":"108","author":"Chibbaro","year":"2008","journal-title":"J. Neurosurg."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1007\/s00701-005-0683-3","article-title":"The camino intracranial pressure device in clinical practice. Assessment in a 1000 cases","volume":"148","author":"Allut","year":"2006","journal-title":"Acta Neurochir."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"600","DOI":"10.3109\/02699052.2013.772238","article-title":"Placement of intracranial pressure monitors by neurointensivists: Case series and a systematic review","volume":"27","author":"Sadaka","year":"2013","journal-title":"Brain Inj."},{"key":"ref_35","first-page":"866","article-title":"An evaluation of the camino ventricular bolt system in clinical practice","volume":"33","author":"Chambers","year":"1993","journal-title":"Neurosurgery"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"1113","DOI":"10.1007\/s007010050224","article-title":"The camino intracranial pressure device in clinical practice: Reliability, handling characteristics and complications","volume":"140","author":"Munch","year":"1998","journal-title":"Acta Neurochir."},{"key":"ref_37","first-page":"296","article-title":"Assessment of the camino intracranial pressure device in clinical practice","volume":"70","author":"Schurer","year":"1997","journal-title":"Acta Neurochir. Suppl."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1007\/BF01617429","article-title":"Comparative analysis between epidural (gaeltec) and subdural (camino) intracranial pressure probes","volume":"8","author":"Weinstabl","year":"1992","journal-title":"J. Clin. Monit."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"491","DOI":"10.3171\/jns.1977.47.4.0491","article-title":"The outcome from severe head injury with early diagnosis and intensive management","volume":"47","author":"Becker","year":"1977","journal-title":"J. Neurosurg."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"150","DOI":"10.3171\/jns.1977.47.2.0150","article-title":"Evaluation of brain function in severe human head trauma with multimodality evoked potentials. Part 1: Evoked brain-injury potentials, methods, and analysis","volume":"47","author":"Greenberg","year":"1977","journal-title":"J. Neurosurg."},{"key":"ref_41","first-page":"498","article-title":"Multimodality evoked potentials and cbf in patients with severe head injury","volume":"64","author":"Greenberg","year":"1977","journal-title":"Acta Neurol. Scand. Suppl."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"711","DOI":"10.1016\/S0736-4679(99)00055-4","article-title":"Management of increased intracranial pressure: A review for clinicians","volume":"17","author":"Marik","year":"1999","journal-title":"J. Emerg. Med."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"503","DOI":"10.3171\/jns.1977.47.4.0503","article-title":"Significance of intracranial hypertension in severe head injury","volume":"47","author":"Miller","year":"1977","journal-title":"J. Neurosurg."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"289","DOI":"10.3171\/jns.1981.54.3.0289","article-title":"Further experience in the management of severe head injury","volume":"54","author":"Miller","year":"1981","journal-title":"J. Neurosurg."},{"key":"ref_45","unstructured":"Association for the Advancement of Medical Instrumentation Imperial County Planning & Development Services, and American National Standards Institute (1993). Intracranial Pressure Monitoring Devices, The Association."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"1137","DOI":"10.1227\/00006123-199506000-00011","article-title":"Clinical evaluation of a miniature strain-gauge transducer for monitoring intracranial pressure","volume":"36","author":"Gopinath","year":"1995","journal-title":"Neurosurgery"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"470","DOI":"10.1007\/BF00393552","article-title":"Intracranial pressure monitoring in children: Comparison of external ventricular device with the fiberoptic system","volume":"9","author":"Gambardella","year":"1993","journal-title":"Child Nerv. Syst."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1007\/BF01402387","article-title":"Clinical evaluation of a simple epidural pressure sensor","volume":"83","author":"Kosteljanetz","year":"1986","journal-title":"Acta Neurochir."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"45","DOI":"10.3171\/jns.1983.58.1.0045","article-title":"A clinical comparison of subdural screw pressure measurements with ventricular pressure","volume":"58","author":"Mendelow","year":"1983","journal-title":"J. Neurosurg."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"737","DOI":"10.3171\/jns.1988.68.5.0737","article-title":"A clinical comparison of subarachnoid catheters to ventriculostomy and subarachnoid bolts: A prospective study","volume":"68","author":"Mollman","year":"1988","journal-title":"J. Neurosurg."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1007\/BF01476066","article-title":"A practical technique for continuous monitoring of cerebral tissue pressure in neurosurgical patients. Preliminary results","volume":"87","author":"Piek","year":"1987","journal-title":"Acta Neurochir."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1007\/BF01724800","article-title":"Continuous monitoring of cerebral tissue pressure in neurosurgical practice\u2014Experiences with 100 patients","volume":"16","author":"Piek","year":"1990","journal-title":"Intensive Care Med."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1016\/0090-3019(95)00359-2","article-title":"The fiberoptic intraparenchymal cerebral pressure monitor in 244 patients","volume":"45","author":"Shapiro","year":"1996","journal-title":"Surg. Neurol."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"421","DOI":"10.1227\/00006123-199003000-00007","article-title":"A clinical evaluation of the camino subdural screw and ventricular monitoring kits","volume":"26","author":"Chambers","year":"1990","journal-title":"Neurosurgery"},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"918","DOI":"10.1227\/00006123-199211000-00014","article-title":"Monitoring of brain tissue pressure with a fiberoptic device","volume":"31","author":"Gambardella","year":"1992","journal-title":"Neurosurgery"},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/0090-3019(92)90147-F","article-title":"Intracranial pressure monitoring: Fiberoptic monitor compared with the ventricular catheter","volume":"37","author":"Schickner","year":"1992","journal-title":"Surg. Neurol."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"123","DOI":"10.3171\/jns.1984.60.1.0123","article-title":"Assessment of leeds device for monitoring intracranial pressure","volume":"60","author":"Dearden","year":"1984","journal-title":"J. Neurosurg."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"660","DOI":"10.3171\/jns.1982.56.5.0660","article-title":"Differential intracranial pressure in patients with unilateral mass lesions","volume":"56","author":"Weaver","year":"1982","journal-title":"J. Neurosurg."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"578","DOI":"10.3171\/jns.1985.63.4.0578","article-title":"Clinical evaluation of two methods of subdural pressure monitoring","volume":"63","author":"Barlow","year":"1985","journal-title":"J. Neurosurg."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1007\/BF01401846","article-title":"Clinical evaluation of a new epidural pressure monitor","volume":"125","author":"Czech","year":"1993","journal-title":"Acta Neurochir."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"745","DOI":"10.3171\/jns.1985.63.5.0745","article-title":"Behavior of an extradural pressure monitor in clinical use. Comparison of extradural with intraventricular pressure in patients with acute and chronically raised intracranial pressure","volume":"63","author":"Powell","year":"1985","journal-title":"J. Neurosurg."},{"key":"ref_62","first-page":"113","article-title":"The spiegelberg device for epidural registration of the icp","volume":"95","author":"Schwarz","year":"1992","journal-title":"Unfallchirurg"},{"key":"ref_63","first-page":"56","article-title":"Interhemispheric pressure gradients in severe head trauma in humans","volume":"71","author":"Mindermann","year":"1998","journal-title":"Acta Neurochir. Suppl."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"16","DOI":"10.3171\/jns.1999.90.1.0016","article-title":"Interhemispheric supratentorial intracranial pressure gradients in head-injured patients: Are they clinically important?","volume":"90","author":"Sahuquillo","year":"1999","journal-title":"J. Neurosurg."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1007\/s10877-006-9047-7","article-title":"Comparison of intracranial pressure measured simultaneously within the brain parenchyma and cerebral ventricles","volume":"20","author":"Brean","year":"2006","journal-title":"J. Clin. Monit. Comput."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"763","DOI":"10.1097\/00006123-200204000-00016","article-title":"There is no transmantle pressure gradient in communicating or noncommunicating hydrocephalus","volume":"50","author":"Stephensen","year":"2002","journal-title":"Neurosurgery"},{"key":"ref_67","first-page":"950393","article-title":"Intracranial pressure monitoring: Invasive versus non-invasive methods-a review","volume":"2012","author":"Raboel","year":"2012","journal-title":"Crit. Care Res. Pract."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1080\/02688690601047312","article-title":"Lumbar cerebrospinal fluid pressure waves versus intracranial pressure waves in idiopathic normal pressure hydrocephalus","volume":"20","author":"Eide","year":"2006","journal-title":"Br. J. Neurosurg."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1080\/02688699646907","article-title":"Simultaneous lumbar and intraventricular manometry to evaluate the role and safety of lumbar puncture in raised intracranial pressure following subarachnoid haemorrhage","volume":"10","author":"Kapadia","year":"1996","journal-title":"Br. J. Neurosurg."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1212\/01.wnl.0000250270.54587.71","article-title":"Csf pressure assessed by lumbar puncture agrees with intracranial pressure","volume":"68","author":"Lenfeldt","year":"2007","journal-title":"Neurology"},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"1263","DOI":"10.1007\/s00134-007-0678-z","article-title":"Neuromonitoring in the intensive care unit. I. Intracranial pressure and cerebral blood flow monitoring","volume":"33","author":"Bhatia","year":"2007","journal-title":"Intensive Care Med."},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1179\/016164103101201661","article-title":"Advances in icp monitoring techniques","volume":"25","author":"Zhong","year":"2003","journal-title":"Neurol. Res."},{"key":"ref_73","first-page":"395","article-title":"Intracranial pressure monitoring techniques","volume":"3","author":"Ghajar","year":"1995","journal-title":"New Horiz."},{"key":"ref_74","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1016\/j.cacc.2003.09.003","article-title":"Intracranial pressure monitoring","volume":"14","author":"Ravi","year":"2013","journal-title":"Curr. Anaesth. Crit. Care"},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"732","DOI":"10.1136\/jnnp.63.6.732","article-title":"Laboratory testing of the spiegelberg brain pressure monitor: A technical report","volume":"63","author":"Czosnyka","year":"1997","journal-title":"J. Neurol. Neurosurg. Psychiatry"},{"key":"ref_76","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1007\/3-211-32318-X_59","article-title":"Assessment of different data representations and averaging methods on the spiegelberg compliance device","volume":"95","author":"Yau","year":"2005","journal-title":"Acta Neurochir. Suppl."},{"key":"ref_77","first-page":"171","article-title":"Clinical experience in the use of the spiegelberg automated compliance device in the assessment of patients with hydrocephalus","volume":"81","author":"Yau","year":"2002","journal-title":"Acta Neurochir. Suppl."},{"key":"ref_78","doi-asserted-by":"crossref","first-page":"841","DOI":"10.1109\/TBME.2013.2291239","article-title":"Telemetric intracranial pressure monitoring in blast-induced traumatic brain injury","volume":"61","author":"Kawoos","year":"2014","journal-title":"IEEE Trans. Bio-Med. Eng."},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1109\/MMM.2014.2377585","article-title":"Too much pressure: Wireless intracranial pressure monitoring and its application in traumatic brain injuries","volume":"16","author":"Kawoos","year":"2015","journal-title":"IEEE Microw. Mag."},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"850","DOI":"10.1007\/BF01700971","article-title":"A comparison of extradural and intraparenchymatous intracranial pressures in head injured patients","volume":"21","author":"Bruder","year":"1995","journal-title":"Intensive Care Med."},{"key":"ref_81","doi-asserted-by":"crossref","first-page":"2356","DOI":"10.1109\/TMTT.2008.2004253","article-title":"In-vitro and in vivo trans-scalp evaluation of an intracranial pressure implant at 2.4 ghz","volume":"56","author":"Kawoos","year":"2008","journal-title":"IEEE Trans. Microw. Theory Tech."},{"key":"ref_82","first-page":"913","article-title":"Description of the response of a new multi-parametric brain sensor to physiological and pathophysiological challenges in the cortex of juvenile pigs","volume":"24","author":"Leidorf","year":"2014","journal-title":"Turk. Neurosurg."},{"key":"ref_83","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1007\/978-3-7091-0956-4_20","article-title":"Telemetric icp measurement with the first ce-approved device: Data from animal experiments and initial clinical experiences","volume":"114","author":"Kiefer","year":"2012","journal-title":"Acta Neurochir. Suppl."},{"key":"ref_84","doi-asserted-by":"crossref","first-page":"852","DOI":"10.3171\/jns.2000.93.5.0852","article-title":"Long-term testing of an intracranial pressure monitoring device","volume":"93","author":"Kroin","year":"2000","journal-title":"J. Neurosurg."},{"key":"ref_85","doi-asserted-by":"crossref","first-page":"62","DOI":"10.2174\/156720209787466046","article-title":"Use of telemetry blood pressure transmitters to measure intracranial pressure (icp) in freely moving rats","volume":"6","author":"Silasi","year":"2009","journal-title":"Curr. Neurovasc. Res."},{"key":"ref_86","doi-asserted-by":"crossref","first-page":"899","DOI":"10.3171\/jns.1977.47.6.0899","article-title":"A pressure-balanced radio-telemetry system for the measurement of intracranial pressure. A preliminary design report","volume":"47","author":"Zervas","year":"1977","journal-title":"J. Neurosurg."},{"key":"ref_87","unstructured":"Swoboda, M., Hochman, M.G., and Fritz, F.J. (2010). Non-Invasive Intracranial Pressure Sensor. (US20130289422 A1), Google Patents."},{"key":"ref_88","doi-asserted-by":"crossref","first-page":"123","DOI":"10.3109\/03005369009077853","article-title":"The relationship between intracranial pressure and tympanic membrane displacement","volume":"24","author":"Reid","year":"1990","journal-title":"Br. J. Audiol."},{"key":"ref_89","doi-asserted-by":"crossref","first-page":"927","DOI":"10.1007\/s00381-013-2036-5","article-title":"The tympanic membrane displacement analyser for monitoring intracranial pressure in children","volume":"29","author":"Gwer","year":"2013","journal-title":"Child Nerv. Syst."},{"key":"ref_90","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1055\/s-2008-1071154","article-title":"Quantitative assessment of intracranial pressure by the tympanic membrane displacement audiometric technique in children with shunted hydrocephalus","volume":"8","author":"Samuel","year":"1998","journal-title":"Eur. J. Pediatr. Surg."},{"key":"ref_91","doi-asserted-by":"crossref","first-page":"983","DOI":"10.3171\/jns.1998.88.6.0983","article-title":"Tympanic membrane displacement testing in regular assessment of intracranial pressure in eight children with shunted hydrocephalus","volume":"88","author":"Samuel","year":"1998","journal-title":"J. Neurosurg."},{"key":"ref_92","doi-asserted-by":"crossref","unstructured":"Ernst, A., Marchbanks, R., and Samii, M. (1996). Intracranial and Intralabyrinthine Fluids: Basic Aspect and Clinical Applications, Springer.","DOI":"10.1007\/978-3-642-80163-1"},{"key":"ref_93","doi-asserted-by":"crossref","first-page":"1050","DOI":"10.1227\/01.NEU.0000369519.35932.F2","article-title":"Transcranial doppler pulsatility index: Not an accurate method to assess intracranial pressure","volume":"66","author":"Behrens","year":"2010","journal-title":"Neurosurgery"},{"key":"ref_94","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/j.surneu.2003.12.007","article-title":"Transcranial doppler sonography pulsatility index (PI) reflects intracranial pressure (ICP)","volume":"62","author":"Bellner","year":"2004","journal-title":"Surg. Neurol."},{"key":"ref_95","doi-asserted-by":"crossref","first-page":"e8","DOI":"10.3171\/foc.2000.8.1.1702","article-title":"Evaluating the outcome of severe head injury with transcranial doppler ultrasonography","volume":"8","author":"Moreno","year":"2000","journal-title":"Neurosurg. Focus"},{"key":"ref_96","first-page":"CR49","article-title":"Early cerebral monitoring using the transcranial doppler pulsatility index in patients with severe brain trauma","volume":"11","author":"Voulgaris","year":"2005","journal-title":"Med. Sci. Monit."},{"key":"ref_97","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1007\/978-3-7091-0956-4_35","article-title":"Near infrared spectroscopy as possible non-invasive monitor of slow vasogenic icp waves","volume":"114","author":"Weerakkody","year":"2012","journal-title":"Acta Neurochir. Suppl."},{"key":"ref_98","doi-asserted-by":"crossref","first-page":"1763","DOI":"10.1007\/s00701-010-0748-9","article-title":"Slow vasogenic fluctuations of intracranial pressure and cerebral near infrared spectroscopy\u2014An observational study","volume":"152","author":"Weerakkody","year":"2010","journal-title":"Acta Neurochir."},{"key":"ref_99","doi-asserted-by":"crossref","first-page":"849","DOI":"10.1213\/ANE.0b013e3182285dc0","article-title":"The limitations of near-infrared spectroscopy to assess cerebrovascular reactivity: The role of slow frequency oscillations","volume":"113","author":"Diedler","year":"2011","journal-title":"Anesth. Analg."},{"key":"ref_100","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1016\/j.annemergmed.2006.06.040","article-title":"Emergency department sonographic measurement of optic nerve sheath diameter to detect findings of increased intracranial pressure in adult head injury patients","volume":"49","author":"Tayal","year":"2007","journal-title":"Ann. Emerg. Med."},{"key":"ref_101","doi-asserted-by":"crossref","first-page":"2062","DOI":"10.1007\/s00134-008-1149-x","article-title":"Non-invasive assessment of intracranial pressure using ocular sonography in neurocritical care patients","volume":"34","author":"Geeraerts","year":"2008","journal-title":"Intensive Care Med."},{"key":"ref_102","doi-asserted-by":"crossref","first-page":"1704","DOI":"10.1007\/s00134-007-0797-6","article-title":"Ultrasonography of the optic nerve sheath may be useful for detecting raised intracranial pressure after severe brain injury","volume":"33","author":"Geeraerts","year":"2007","journal-title":"Intensive Care Med."},{"key":"ref_103","doi-asserted-by":"crossref","first-page":"785","DOI":"10.1016\/j.annemergmed.2008.11.025","article-title":"Bedside sonographic measurement of optic nerve sheath diameter as a predictor of increased intracranial pressure in children","volume":"53","author":"Le","year":"2009","journal-title":"Ann. Emerg. Med."},{"key":"ref_104","first-page":"82","article-title":"Measurement of intracranial pressure in children without puncture (new method)","volume":"43","author":"Purin","year":"1964","journal-title":"Pediatriia"},{"key":"ref_105","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1136\/jnnp.37.1.88","article-title":"Methods of measuring intracranial pressure via the fontanelle without puncture","volume":"37","author":"Wealthall","year":"1974","journal-title":"J. Neurol. Neurosurg. Psychiatry"},{"key":"ref_106","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1136\/adc.62.2.152","article-title":"New fontanometer for continuous estimation of intracranial pressure in the newborn","volume":"62","author":"Rochefort","year":"1987","journal-title":"Arch. Dis. Child."},{"key":"ref_107","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1088\/0143-0815\/11\/2\/002","article-title":"Strain-gauge fontanometry\u2014An advance in non-invasive intracranial pressure measurement","volume":"11","author":"Pairaudeau","year":"1990","journal-title":"Clin. Phys. Physiol. Meas."},{"key":"ref_108","unstructured":"Ueno, T., Macias, B.R., Hargens, A.R., and Yost, W.T. (2003, January 5\u20138). Pulsed Phase Lock Loop Technique to Measure Intracranial Pressure Non-Invasively. Proceedings of the 2003 IEEE Symposium on Ultrasonics, Honolulu, HI, USA."},{"key":"ref_109","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1186\/1475-925X-10-75","article-title":"The baseline pressure of intracranial pressure (icp) sensors can be altered by electrostatic discharges","volume":"10","author":"Eide","year":"2011","journal-title":"Biomed. Eng. Online"},{"key":"ref_110","doi-asserted-by":"crossref","first-page":"817","DOI":"10.3171\/jns.1983.59.5.0817","article-title":"Analysis of the cerebrospinal fluid pulse wave in intracranial pressure","volume":"59","author":"Cardoso","year":"1983","journal-title":"J. Neurosurg."},{"key":"ref_111","first-page":"347","article-title":"Lundberg\u2019s b waves as a feature of normal intracranial pressure","volume":"9","author":"Martin","year":"1978","journal-title":"Surg. Neurol."},{"key":"ref_112","first-page":"187","article-title":"A module of statistical analysis of the intracranial pressure: The s.A.I.C.P. System","volume":"23","author":"Janny","year":"1977","journal-title":"Neuro-Chirurgie"},{"key":"ref_113","doi-asserted-by":"crossref","first-page":"111","DOI":"10.4103\/2229-5151.100886","article-title":"The ongoing and worldwide challenge of pediatric trauma","volume":"2","author":"Sharar","year":"2012","journal-title":"Int. J. Crit. Illn. Inj. Sci."},{"key":"ref_114","doi-asserted-by":"crossref","first-page":"1067","DOI":"10.1007\/s00134-015-3806-1","article-title":"Visualizing the pressure and time burden of intracranial hypertension in adult and paediatric traumatic brain injury","volume":"41","author":"Guiza","year":"2015","journal-title":"Intensive Care Med."},{"key":"ref_115","doi-asserted-by":"crossref","first-page":"1800","DOI":"10.1007\/s00134-012-2655-4","article-title":"Mortality and long-term functional outcome associated with intracranial pressure after traumatic brain injury","volume":"38","author":"Badri","year":"2012","journal-title":"Intensive Care Med."},{"key":"ref_116","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1007\/s00701-003-0187-y","article-title":"Intracranial hypertension: What additional information can be derived from icp waveform after head injury?","volume":"146","author":"Balestreri","year":"2004","journal-title":"Acta Neurochir."},{"key":"ref_117","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1385\/NCC:4:1:008","article-title":"Impact of intracranial pressure and cerebral perfusion pressure on severe disability and mortality after head injury","volume":"4","author":"Balestreri","year":"2006","journal-title":"Neurocrit. Care"},{"key":"ref_118","first-page":"949","article-title":"Neuromonitoring in traumatic brain injury","volume":"78","author":"Feyen","year":"2012","journal-title":"Minerva Anestesiol."},{"key":"ref_119","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/PCC.0b013e318259ee85","article-title":"Guidelines for the acute medical management of severe traumatic brain injury in infants, children, and adolescents\u2014Second edition","volume":"13","author":"Kochanek","year":"2012","journal-title":"Pediatr. Crit. Care Med."},{"key":"ref_120","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1227\/00006123-198601000-00004","article-title":"Acute head injury: Pressure-volume relations and cerebrospinal fluid dynamics","volume":"18","author":"Kosteljanetz","year":"1986","journal-title":"Neurosurgery"},{"key":"ref_121","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1007\/s12028-011-9630-8","article-title":"Critical thresholds for cerebrovascular reactivity after traumatic brain injury","volume":"16","author":"Sorrentino","year":"2012","journal-title":"Neurocrit. Care"},{"key":"ref_122","doi-asserted-by":"crossref","first-page":"574","DOI":"10.3171\/2014.10.JNS1460","article-title":"Impact of intracranial pressure monitoring on mortality in patients with traumatic brain injury: A systematic review and meta-analysis","volume":"122","author":"Yuan","year":"2015","journal-title":"J. Neurosurg."},{"key":"ref_123","doi-asserted-by":"crossref","first-page":"1737","DOI":"10.1089\/neu.2012.2802","article-title":"Intracranial pressure monitoring in severe traumatic brain injury: Results from the american college of surgeons trauma quality improvement program","volume":"30","author":"Alali","year":"2013","journal-title":"J. Neurotrauma"},{"key":"ref_124","doi-asserted-by":"crossref","first-page":"2471","DOI":"10.1056\/NEJMoa1207363","article-title":"A trial of intracranial-pressure monitoring in traumatic brain injury","volume":"367","author":"Chesnut","year":"2012","journal-title":"N. Engl. J. Med."},{"key":"ref_125","doi-asserted-by":"crossref","first-page":"15","DOI":"10.5492\/wjccm.v1.i1.15","article-title":"Contemporary view on neuromonitoring following severe traumatic brain injury","volume":"1","author":"Stover","year":"2012","journal-title":"World J. Crit. Care Med."},{"key":"ref_126","doi-asserted-by":"crossref","first-page":"121","DOI":"10.3389\/fneur.2014.00121","article-title":"Monitoring of intracranial pressure in patients with traumatic brain injury","volume":"5","author":"Hawthorne","year":"2014","journal-title":"Front. Neurol."},{"key":"ref_127","doi-asserted-by":"crossref","first-page":"1615","DOI":"10.1007\/s00701-014-2127-4","article-title":"Clinical applications of intracranial pressure monitoring in traumatic brain injury: Report of the milan consensus conference","volume":"156","author":"Stocchetti","year":"2014","journal-title":"Acta Neurochir."},{"key":"ref_128","doi-asserted-by":"crossref","first-page":"207","DOI":"10.4103\/1817-1745.147572","article-title":"Management of raised intracranial pressure in children with traumatic brain injury","volume":"9","author":"Kukreti","year":"2014","journal-title":"J. Pediatr. Neurosci."},{"key":"ref_129","doi-asserted-by":"crossref","first-page":"S64","DOI":"10.1007\/s12028-014-0048-y","article-title":"Intracranial pressure monitoring: Fundamental considerations and rationale for monitoring","volume":"21","author":"Chesnut","year":"2014","journal-title":"Neurocrit. Care"},{"key":"ref_130","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1093\/bja\/aet418","article-title":"Intracranial pressure monitoring, cerebral perfusion pressure estimation, and icp\/cpp-guided therapy: A standard of care or optional extra after brain injury?","volume":"112","author":"Kirkman","year":"2014","journal-title":"Br. J. Anaesth."},{"key":"ref_131","doi-asserted-by":"crossref","first-page":"761","DOI":"10.1016\/S1042-3680(18)30431-5","article-title":"Introduction to cerebral perfusion pressure management","volume":"6","author":"Rosner","year":"1995","journal-title":"Neurosurg. Clin. N. Am."},{"key":"ref_132","doi-asserted-by":"crossref","first-page":"949","DOI":"10.3171\/jns.1995.83.6.0949","article-title":"Cerebral perfusion pressure: Management protocol and clinical results","volume":"83","author":"Rosner","year":"1995","journal-title":"J. Neurosurg."},{"key":"ref_133","doi-asserted-by":"crossref","first-page":"1513","DOI":"10.1097\/00000542-200112000-00034","article-title":"Management of cerebral perfusion pressure after traumatic brain injury","volume":"95","author":"Robertson","year":"2001","journal-title":"Anesthesiology"},{"key":"ref_134","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1385\/NCC:2:1:083","article-title":"Physiological and biochemical principles underlying volume-targeted therapy\u2014The \u201clund concept\u201d","volume":"2","author":"Nordstrom","year":"2005","journal-title":"Neurocrit. Care"},{"key":"ref_135","doi-asserted-by":"crossref","first-page":"560","DOI":"10.3171\/jns.2001.95.4.0560","article-title":"Adult respiratory distress syndrome: A complication of induced hypertension after severe head injury","volume":"95","author":"Contant","year":"2001","journal-title":"J. Neurosurg."},{"key":"ref_136","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3171\/jns.2000.92.1.0001","article-title":"Intracranial hypertension and cerebral perfusion pressure: Influence on neurological deterioration and outcome in severe head injury. The executive committee of the international selfotel trial","volume":"92","author":"Juul","year":"2000","journal-title":"J. Neurosurg."},{"key":"ref_137","first-page":"152","article-title":"Management of intracranial hypertension in head injury: Matching treatment with cause","volume":"57","author":"Miller","year":"1993","journal-title":"Acta Neurochir. Suppl."},{"key":"ref_138","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1007\/s12028-011-9526-7","article-title":"Medical management of compromised brain oxygen in patients with severe traumatic brain injury","volume":"14","author":"Bohman","year":"2011","journal-title":"Neurocrit. Care"},{"key":"ref_139","doi-asserted-by":"crossref","first-page":"895","DOI":"10.1097\/00003246-199705000-00033","article-title":"Cerebral perfusion pressure monitoring alert!","volume":"25","author":"Nates","year":"1997","journal-title":"Crit. Care Med."},{"key":"ref_140","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.1109\/TBME.2009.2037607","article-title":"Forecasting icp elevation based on prescient changes of intracranial pressure waveform morphoogy","volume":"57","author":"Hu","year":"2010","journal-title":"IEEE Trans. Bio-Med. Eng."},{"key":"ref_141","first-page":"1261","article-title":"Timing and duration of intracranial hypertension versus outcomes after severe traumatic brain injury","volume":"80","author":"Majdan","year":"2014","journal-title":"Minerva Anestesiol."}],"container-title":["International Journal of Molecular Sciences"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1422-0067\/16\/12\/26146\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T20:53:27Z","timestamp":1760216007000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1422-0067\/16\/12\/26146"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,12,4]]},"references-count":141,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2015,12]]}},"alternative-id":["ijms161226146"],"URL":"https:\/\/doi.org\/10.3390\/ijms161226146","relation":{},"ISSN":["1422-0067"],"issn-type":[{"value":"1422-0067","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,12,4]]}}}