{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T20:53:43Z","timestamp":1782334423289,"version":"3.54.5"},"reference-count":41,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2024,12,8]],"date-time":"2024-12-08T00:00:00Z","timestamp":1733616000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Fondation Coeur\u2014Daniel Wagner, Fondation de Luxembourg"},{"name":"Deutsche Forschungsgemeinschaft"},{"name":"Heidelberg University"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCDD"],"abstract":"<jats:p>Aims: Patients after heart transplantation (HTX) often experience post-transplant bradycardia, but little is known about the outcomes of early pacemaker dependency after HTX. We compared post-transplant mortality, graft failure, and the requirement for the permanent pacemaker implantation of patients with and without early pacemaker dependency after HTX. Methods: We screened all adult patients for early pacemaker dependency after HTX (defined as immediately after surgery) who underwent HTX at Heidelberg Heart Center between 1989 and 2022. Patients were stratified by diagnosis and type of early pacemaker dependency after HTX (sinoatrial or atrioventricular conduction disturbance). Results: A total of 127 of 699 HTX recipients (18.2%) had early pacemaker dependency after HTX, including 52 patients with sinoatrial conduction disturbances (40.9%) and 75 patients with atrioventricular conduction disturbances (59.1%). Patients with early pacemaker dependency after HTX showed both increased 1-year overall mortality after HTX (55.9% vs. 15.2%, p &lt; 0.001) and higher mortality due to graft failure (25.2% vs. 4.2%, p &lt; 0.001). Multivariate analysis revealed early pacemaker dependency after HTX (HR: 5.226, 95% CI: 3.738\u20137.304, p &lt; 0.001) as an independent risk factor for 1-year mortality after HTX. Patients with early pacemaker dependency after HTX had a higher rate of 30-day (7.1% vs. 0.4%, p &lt; 0.001) and 1-year (11.8% vs. 0.5%, p &lt; 0.001) permanent pacemaker implantation after HTX compared to patients without early pacemaker dependency after HTX. Conclusions: Patients with early pacemaker dependency after HTX had a significantly higher rate of post-transplant mortality, graft failure, and the requirement for permanent pacemaker implantation.<\/jats:p>","DOI":"10.3390\/jcdd11120394","type":"journal-article","created":{"date-parts":[[2024,12,9]],"date-time":"2024-12-09T08:17:49Z","timestamp":1733732269000},"page":"394","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Early Pacemaker Dependency After Heart Transplantation Is Associated with Permanent Pacemaker Implantation, Graft Failure and Mortality"],"prefix":"10.3390","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4896-9219","authenticated-orcid":false,"given":"Fabrice F.","family":"Darche","sequence":"first","affiliation":[{"name":"Department of Cardiology, Angiology and Pneumology, Heidelberg University Hospital, 69120 Heidelberg, Germany"},{"name":"Heidelberg Center for Heart Rhythm Disorders (HCR), Heidelberg University Hospital, 69120 Heidelberg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karsten M.","family":"Heil","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Angiology and Pneumology, Heidelberg University Hospital, 69120 Heidelberg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1146-6319","authenticated-orcid":false,"given":"Rasmus","family":"Rivinius","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Angiology and Pneumology, Heidelberg University Hospital, 69120 Heidelberg, Germany"},{"name":"Heidelberg Center for Heart Rhythm Disorders (HCR), Heidelberg University Hospital, 69120 Heidelberg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthias","family":"Helmschrott","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Angiology and Pneumology, Heidelberg University Hospital, 69120 Heidelberg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philipp","family":"Ehlermann","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Angiology and Pneumology, Heidelberg University Hospital, 69120 Heidelberg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Norbert","family":"Frey","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Angiology and Pneumology, Heidelberg University Hospital, 69120 Heidelberg, Germany"},{"name":"Heidelberg Center for Heart Rhythm Disorders (HCR), Heidelberg University Hospital, 69120 Heidelberg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7509-887X","authenticated-orcid":false,"given":"Ann-Kathrin","family":"Rahm","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Angiology and Pneumology, Heidelberg University Hospital, 69120 Heidelberg, Germany"},{"name":"Heidelberg Center for Heart Rhythm Disorders (HCR), Heidelberg University Hospital, 69120 Heidelberg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2024,12,8]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"e007954","DOI":"10.1161\/CIRCEP.120.007954","article-title":"Management of Arrhythmias After Heart Transplant: Current State and Considerations for Future Research","volume":"14","author":"Joglar","year":"2021","journal-title":"Circ. Arrhythm. Electrophysiol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"149","DOI":"10.15420\/aer.2014.3.3.149","article-title":"Arrhythmias in the Heart Transplant Patient","volume":"3","author":"Hamon","year":"2014","journal-title":"Arrhythm. Electrophysiol. Rev."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"832","DOI":"10.1016\/S0735-1097(10)80330-4","article-title":"Cardiac rhythm disturbances early after orthotopic heart transplantation: Prevalence and clinical importance of the observed abnormalities","volume":"16","author":"Jacquet","year":"1990","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"e001461","DOI":"10.1161\/JAHA.112.001461","article-title":"Arrhythmias after heart transplantation: Mechanisms and management","volume":"1","author":"Thajudeen","year":"2012","journal-title":"J. Am. Heart Assoc."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"4265","DOI":"10.1002\/ehf2.13552","article-title":"Atrial fibrillation before heart transplantation is a risk factor for post-transplant atrial fibrillation and mortality","volume":"8","author":"Darche","year":"2021","journal-title":"ESC Heart Fail."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Darche, F.F., Fabricius, L.C., Helmschrott, M., Rahm, A.K., Ehlermann, P., Bruckner, T., Sommer, W., Warnecke, G., Frey, N., and Rivinius, R. (2023). Oral Anticoagulants after Heart Transplantation-Comparison between Vitamin K Antagonists and Direct Oral Anticoagulants. J. Clin. Med., 12.","DOI":"10.3390\/jcm12134334"},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Rahm, A.K., Reinhardt, S., Helmschrott, M., Darche, F.F., Bruckner, T., Lugenbiel, P., Thomas, D., Ehlermann, P., Sommer, W., and Warnecke, G. (2022). Frequency, Risk Factors, and Clinical Outcomes of Late-Onset Atrial Flutter in Patients after Heart Transplantation. J. Cardiovasc. Dev. Dis., 9.","DOI":"10.3390\/jcdd9100337"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1007\/s00392-017-1165-3","article-title":"Control of cardiac chronotropic function in patients after heart transplantation: Effects of ivabradine and metoprolol succinate on resting heart rate in the denervated heart","volume":"107","author":"Rivinius","year":"2018","journal-title":"Clin. Res. Cardiol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"287","DOI":"10.2147\/TCRM.S126869","article-title":"The influence of surgical technique on early posttransplant atrial fibrillation\u2014Comparison of biatrial, bicaval, and total orthotopic heart transplantation","volume":"13","author":"Rivinius","year":"2017","journal-title":"Ther. Clin. Risk Manag."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"5440","DOI":"10.21037\/jtd.2019.11.45","article-title":"Risk factors and survival of patients with permanent pacemaker implantation after heart transplantation","volume":"11","author":"Rivinius","year":"2019","journal-title":"J. Thorac. Dis."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1016\/j.healun.2009.04.034","article-title":"Long-term outcomes and clinical predictors for pacing after cardiac transplantation","volume":"28","author":"Cantillon","year":"2009","journal-title":"J. Heart Lung Transplant."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1385","DOI":"10.1016\/0002-9149(91)90469-2","article-title":"Frequency and mechanism of bradycardia in cardiac transplant recipients and need for pacemakers","volume":"67","author":"DiBiase","year":"1991","journal-title":"Am. J. Cardiol."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1590\/S0066-782X2000000100002","article-title":"Permanent and temporary pacemaker implantation after orthotopic heart transplantation","volume":"74","author":"Bacal","year":"2000","journal-title":"Arq. Bras. Cardiol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1567","DOI":"10.1016\/j.hrthm.2010.06.026","article-title":"Long-term outcomes and clinical predictors for pacemaker-requiring bradyarrhythmias after cardiac transplantation: Analysis of the UNOS\/OPTN cardiac transplant database","volume":"7","author":"Cantillon","year":"2010","journal-title":"Heart Rhythm."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1142","DOI":"10.1016\/j.healun.2006.07.003","article-title":"Permanent pacing after cardiac transplantation in the era of extended donors","volume":"25","author":"Zieroth","year":"2006","journal-title":"J. Heart Lung Transplant."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1263","DOI":"10.1016\/0003-4975(95)00612-O","article-title":"Permanent pacemaker for rejection episodes after heart transplantation: A poor prognostic sign","volume":"60","author":"Blanche","year":"1995","journal-title":"Ann. Thorac. Surg."},{"key":"ref_17","first-page":"20","article-title":"Pacemaker Use Following Heart Transplantation","volume":"17","author":"Mallidi","year":"2017","journal-title":"Ochsner J."},{"key":"ref_18","first-page":"313","article-title":"Bradyarrhythmia after heart transplantation. Incidence, time course, and outcome","volume":"82","author":"Miyamoto","year":"1990","journal-title":"Circulation"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1136\/hrt.69.5.399","article-title":"Permanent pacing after cardiac transplantation","volume":"69","author":"Scott","year":"1993","journal-title":"Br. Heart J."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1257","DOI":"10.1016\/j.healun.2011.05.010","article-title":"Permanent pacemaker implantation early and late after heart transplantation: Clinical indication, risk factors and prognostic implications","volume":"30","author":"Jones","year":"2011","journal-title":"J. Heart Lung Transplant."},{"key":"ref_21","first-page":"255","article-title":"Does the surgical technique used in the orthotopic heart transplant affect the results regarding the rhythm?","volume":"12","author":"Kara","year":"2012","journal-title":"Anadolu Kardiyol. Derg."},{"key":"ref_22","first-page":"236","article-title":"Posttransplant pacemaker placement: Case series and review","volume":"10","author":"Thompson","year":"2010","journal-title":"Ochsner J."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1093\/icvts\/ivr084","article-title":"Bicaval versus standard technique in orthotopic heart transplant: Assessment of atrial performance at magnetic resonance and transthoracic echocardiography","volume":"14","author":"Mastrobuoni","year":"2012","journal-title":"Interact. Cardiovasc. Thorac. Surg."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1111\/j.0886-0440.2005.05011.x","article-title":"Orthotopic cardiac transplantation: Comparison of outcome using biatrial, bicaval, and total techniques","volume":"20","author":"Morgan","year":"2005","journal-title":"J. Card. Surg."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"2037","DOI":"10.1111\/j.1540-8159.1992.tb03017.x","article-title":"Pacemaker dependency after coronary artery bypass","volume":"15","author":"Feldman","year":"1992","journal-title":"Pacing Clin. Electrophysiol."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Steyers, C.M., Khera, R., and Bhave, P. (2015). Pacemaker Dependency after Cardiac Surgery: A Systematic Review of Current Evidence. PLoS ONE, 10.","DOI":"10.1371\/journal.pone.0140340"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1306","DOI":"10.1161\/CIRCULATIONAHA.106.180200","article-title":"Recommendations for the standardization and interpretation of the electrocardiogram: Part I: The electrocardiogram and its technology: A scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Cardiology Foundation; and the Heart Rhythm Society: Endorsed by the International Society for Computerized Electrocardiology","volume":"115","author":"Kligfield","year":"2007","journal-title":"Circulation"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1325","DOI":"10.1161\/CIRCULATIONAHA.106.180201","article-title":"Recommendations for the standardization and interpretation of the electrocardiogram: Part II: Electrocardiography diagnostic statement list: A scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Cardiology Foundation; and the Heart Rhythm Society: Endorsed by the International Society for Computerized Electrocardiology","volume":"115","author":"Mason","year":"2007","journal-title":"Circulation"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"e235","DOI":"10.1161\/CIRCULATIONAHA.108.191095","article-title":"AHA\/ACCF\/HRS recommendations for the standardization and interpretation of the electrocardiogram: Part III: Intraventricular conduction disturbances: A scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Cardiology Foundation; and the Heart Rhythm Society: Endorsed by the International Society for Computerized Electrocardiology","volume":"119","author":"Surawicz","year":"2009","journal-title":"Circulation"},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Doulamis, I.P., Wu, B., Akbar, A.F., Xanthopoulos, A., Androulakis, E., and Briasoulis, A. (2023). Pacemaker Implantation following Heart Transplantation: Analysis of a Nation-Wide Database. J. Clin. Med., 12.","DOI":"10.3390\/jcm12041604"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"e14296","DOI":"10.1111\/ctr.14296","article-title":"Acute kidney injury post-heart transplant: An analysis of peri-operative risk factors","volume":"35","author":"Jocher","year":"2021","journal-title":"Clin. Transplant."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"203","DOI":"10.5500\/wjt.v11.i6.203","article-title":"Hyperkalemia: Major but still understudied complication among heart transplant recipients","volume":"11","author":"Singh","year":"2021","journal-title":"World J. Transplant."},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Thongprayoon, C., Lertjitbanjong, P., Hansrivijit, P., Crisafio, A., Mao, M.A., Watthanasuntorn, K., Aeddula, N.R., Bathini, T., Kaewput, W., and Cheungpasitporn, W. (2019). Acute Kidney Injury in Patients Undergoing Cardiac Transplantation: A Meta-Analysis. Medicines, 6.","DOI":"10.3390\/medicines6040108"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"2314","DOI":"10.1093\/eurheartj\/ehy060","article-title":"Chronic kidney disease and arrhythmias: Conclusions from a Kidney Disease: Improving Global Outcomes (KDIGO) Controversies Conference","volume":"39","author":"Turakhia","year":"2018","journal-title":"Eur. Heart J."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1111\/pace.13021","article-title":"A Single Center Study of 1,179 Heart Transplant Patients-Factors Affecting Pacemaker Implantation","volume":"40","author":"Wellmann","year":"2017","journal-title":"Pacing Clin. Electrophysiol."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"1556","DOI":"10.1016\/0735-1097(92)90450-2","article-title":"Amiodarone therapy does not compromise subsequent heart transplantation","volume":"20","author":"Middlekauff","year":"1992","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_37","first-page":"743","article-title":"The effect of chronic amiodarone therapy before transplantation on early cardiac allograft function","volume":"10","author":"Macdonald","year":"1991","journal-title":"J. Heart Lung Transplant."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"1827","DOI":"10.2147\/DDDT.S136948","article-title":"Comparison of posttransplant outcomes in patients with no, acute, or chronic amiodarone use before heart transplantation","volume":"11","author":"Rivinius","year":"2017","journal-title":"Drug Des. Dev. Ther."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"1216","DOI":"10.1097\/TP.0b013e31816b677c","article-title":"Incidence, predictors, and outcomes of cardiac pacing after cardiac transplantation: An 11-year retrospective analysis","volume":"85","author":"Woo","year":"2008","journal-title":"Transplantation"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"S187","DOI":"10.1016\/j.healun.2004.03.009","article-title":"Cardiac allograft vasculopathy after heart transplantation: Risk factors and management","volume":"23","author":"Valantine","year":"2004","journal-title":"J. Heart Lung Transplant."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"1239","DOI":"10.1002\/ehf2.13799","article-title":"Cardiac allograft vasculopathy and donor age affecting permanent pacemaker implantation after heart transplantation","volume":"9","author":"Roest","year":"2022","journal-title":"ESC Heart Fail."}],"container-title":["Journal of Cardiovascular Development and Disease"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2308-3425\/11\/12\/394\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T16:49:42Z","timestamp":1760114982000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2308-3425\/11\/12\/394"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,8]]},"references-count":41,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["jcdd11120394"],"URL":"https:\/\/doi.org\/10.3390\/jcdd11120394","relation":{},"ISSN":["2308-3425"],"issn-type":[{"value":"2308-3425","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,8]]}}}