{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T20:15:36Z","timestamp":1793391336622,"version":"4.5.0"},"reference-count":35,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2024,12,11]],"date-time":"2024-12-11T00:00:00Z","timestamp":1733875200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCDD"],"abstract":"<jats:p>The need for a permanent pacemaker (PPM) implantation after surgical aortic valve implantation (SAVR) is a recognized postoperative complication, with potentially long-term reduced survival. From 1987 to 2017, 2500 consecutive patients underwent SAVR with a biological valve with or without concomitant procedures such as CABG or mitral valve repair. Mechanical valves or valves in another position were excluded. Univariate and multivariate analyses were performed. The need for PPM implantation was documented in 2.7% of the cases. Patients with a postoperative PPM were older and had higher risk scores and a higher comorbid burden. Its predictors were a prior SAVR (odds ratio of 5.38, p &lt; 0.001), use of a Perceval valve (3.94, p = 0.008), prior AV block 1\u20132 (2.86, p = 0.008), and pulmonary hypertension (2.09, p = 0.017). The need for PPM implantation was associated with an increased need for blood products, a prolonged stay in the ICU, and an increased 30-day mortality (2.5% vs. 7.0%, p = 0.005). The median survival decreased from 117 (114\u2013120) to 90 (74\u2013105) months (p &lt; 0.001). The implantation had no significant effect on the freedom of congestive heart failure. The need for a PPM implant is not a benign event but might be a marker for a more severe underlying disease. Improving surgical techniques, especially with the Perceval rapid deployment valve, might decrease the need for a PPM implant.<\/jats:p>","DOI":"10.3390\/jcdd11120397","type":"journal-article","created":{"date-parts":[[2024,12,11]],"date-time":"2024-12-11T03:14:58Z","timestamp":1733886898000},"page":"397","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Predictors of the Need for Permanent Pacemaker Implantation After Surgical Aortic Valve Replacement with a Biological Prosthesis and the Effect on Long-Term Survival"],"prefix":"10.3390","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-0809-2594","authenticated-orcid":false,"given":"Ivo","family":"Deblier","sequence":"first","affiliation":[{"name":"Department Cardiovascular Surgery, ZNA Middelheim Hospital, 2020 Antwerp, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karl","family":"Dossche","sequence":"additional","affiliation":[{"name":"Department Cardiovascular Surgery, ZNA Middelheim Hospital, 2020 Antwerp, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anthony","family":"Vanermen","sequence":"additional","affiliation":[{"name":"Department Cardiovascular Surgery, ZNA Middelheim Hospital, 2020 Antwerp, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8583-2524","authenticated-orcid":false,"given":"Wilhelm","family":"Mistiaen","sequence":"additional","affiliation":[{"name":"Faculty of Medicine & Health Sciences, University of Antwerp, 2610 Antwerp, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2024,12,11]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"3519","DOI":"10.1111\/jocs.15803","article-title":"Incidence and predictors of permanent pacemaker implantation after surgical aortic v alve replacement: Data of the Netherlands Heart Registration (NHR)","volume":"36","author":"Ravaux","year":"2021","journal-title":"J. Card. Surg."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"4526","DOI":"10.1093\/eurheartj\/ehae585","article-title":"Aortic valve replacement vs. conservative treatment in asymptomatic severe aortic stenosis: Long-term follow-up of the AVATAR trial","volume":"45","author":"Banovic","year":"2024","journal-title":"Eur. Heart J."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"e2116564","DOI":"10.1001\/jamanetworkopen.2021.16564","article-title":"Long-term Outcomes Associated With Permanent Pacemaker Implantation After Surgical Aortic Valve Replacement","volume":"4","author":"Glaser","year":"2021","journal-title":"JAMA Netw. Open"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"101110","DOI":"10.1016\/j.jacadv.2024.101110","article-title":"Long-Term Outcomes Associated With Permanent Pacemaker Implantation in Low-Risk Surgical Aortic Valve Replacement","volume":"3","author":"Lu","year":"2024","journal-title":"JACC Adv."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1007\/s11748-020-01450-y","article-title":"Modified annular suturing technique for minimizing postoperative pacemaker use after surgical aortic valve replacement","volume":"69","author":"Yanagisawa","year":"2021","journal-title":"Gen. Thorac. Cardiovasc. Surg."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1556","DOI":"10.1016\/j.jtcvs.2017.05.101","article-title":"Conduction disturbance after isolated surgical aortic valve replacement in degenerative aortic stenosis","volume":"154","author":"Hwang","year":"2017","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1093\/icvts\/ivac182","article-title":"Recent improvement in operative techniques lead to lower pacemaker rate after Perceval implant","volume":"35","author":"Fabre","year":"2022","journal-title":"Interact. Cardiovasc. Thorac. Surg."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"917","DOI":"10.1016\/j.hlc.2020.11.004","article-title":"Predictors of Pacemaker Insertion Post-Sutureless (Perceval) Aortic Valve Implantation","volume":"30","author":"Brookes","year":"2020","journal-title":"Heart Lung Circ."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"e047962","DOI":"10.1136\/bmjopen-2020-047962","article-title":"Permanent pacemaker implantation after On-X surgical aortic valve replacement: SWEDEHEART observational study","volume":"11","author":"Persson","year":"2021","journal-title":"BMJ Open"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1007\/s10047-021-01301-4","article-title":"Evaluation of oversizing in association with conduction disorder after implantation of a rapid deployment valve","volume":"25","author":"Hori","year":"2021","journal-title":"J. Artif. Organs"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"708","DOI":"10.3390\/prosthesis6030050","article-title":"The Outcomes for Different Biological Heart Valve Prostheses in Surgical Aortic Valve Replacement before and after the Introduction of Transcatheter Aortic Valve Implantation","volume":"6","author":"Deblier","year":"2024","journal-title":"Prosthesis"},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Mistiaen, W., Deblier, I., Dossche, K., and Vanermen, A. (2024). Clinical Outcomes after Surgical Aortic Valve Replacement in 681 Octogenarians: A Single-Center Real-World Experience Comparing the Old Patients with the Very Old Patients. Geriatrics, 9.","DOI":"10.3390\/geriatrics9020044"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1687","DOI":"10.1136\/heartjnl-2011-300308","article-title":"Permanent pacemaker implantation following isolated aortic valve replacement in a large cohort of elderly patients with severe aortic stenosis","volume":"97","author":"Bagur","year":"2011","journal-title":"Heart"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"14","DOI":"10.2459\/JCM.0b013e32832f9fde","article-title":"Permanent pacemaker implantation after isolated aortic valve replacement: Incidence, risk factors and surgical technical aspects","volume":"11","author":"Nardi","year":"2010","journal-title":"J. Cardiovasc. Med."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1016\/j.athoracsur.2007.08.024","article-title":"Permanent pacemaker implantation after isolated aortic valve replacement: Incidence, indications, and predictors","volume":"85","author":"Dawkins","year":"2008","journal-title":"Ann. Thorac. Surg."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"E396","DOI":"10.1532\/HSF98.20051025","article-title":"Does the type of prosthesis influence the incidence of permanent pacemaker implantation following isolated aortic valve replacement","volume":"8","author":"Elahi","year":"2005","journal-title":"Heart Surg. Forum"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1520","DOI":"10.1111\/j.1540-8159.2009.02552.x","article-title":"Permanent pacemaker implantation following aortic valve replacement: Current prevalence and clinical predictors","volume":"32","author":"Huynh","year":"2009","journal-title":"Pacing Clin. Electrophysiol."},{"key":"ref_18","first-page":"520","article-title":"Aortic valve calcification evaluated by echocardiography associated with baseline conduction abnormalities as a predictor for pacemaker placement after aortic valve replacement","volume":"66","year":"2014","journal-title":"Rev. Investig. Clin."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1093\/icvts\/ivaa335","article-title":"Recovery of conduction disorders after sutureless aortic valve replacement","volume":"32","author":"Lam","year":"2021","journal-title":"Interact. Cardiovasc. Thorac. Surg."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1093\/icvts\/ivv330","article-title":"Sutureless aortic valve replacement with Perceval bioprosthesis: Are there predicting factors for postoperative pacemaker implantation?","volume":"22","author":"Vogt","year":"2015","journal-title":"Interact. Cardiovasc. Thorac. Surg."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"490","DOI":"10.1016\/j.acvd.2022.05.007","article-title":"Early pacemaker insertion after aortic valve replacement with an Edwards Intuity sutureless valve","volume":"115","author":"Mechulan","year":"2022","journal-title":"Arch. Cardiovasc. Dis."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1055\/s-0042-1757778","article-title":"Pacemaker after Sutureless and Rapid-Deployment Prostheses: A Progress Report from the SURD-IR","volume":"71","author":"Pollari","year":"2023","journal-title":"Thorac. Cardiovasc. Surg."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1093\/icvts\/ivac157","article-title":"Avoiding oversizing in sutureless valves leads to lower transvalvular gradients and less permanent pacemaker implants postoperatively","volume":"35","author":"Szecel","year":"2022","journal-title":"Interact. Cardiovasc. Thorac. Surg."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"899","DOI":"10.1093\/ejcts\/ezab431","article-title":"3-Dimensional computed tomographic assessment predicts conduction block and paravalvular leakage after rapid-deployment aortic valve replacement","volume":"61","author":"Park","year":"2021","journal-title":"Eur. J. Cardio-Thoracic Surg."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/S0022-5223(98)70245-4","article-title":"The increased need for a permanent pacemaker after reoperative cardiac surgery","volume":"116","author":"Lewis","year":"1998","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"556","DOI":"10.1510\/icvts.2010.249904","article-title":"Incidence and risk factors for pacemaker implantation following aortic valve replacement","volume":"11","author":"Schurr","year":"2010","journal-title":"Interact. Cardiovasc. Thorac. Surg."},{"key":"ref_27","first-page":"106","article-title":"Report on outcomes of valve-in-valve transcatheter aortic valve implantation and redo surgical aortic valve replacement in the Netherlands","volume":"30","author":"Lam","year":"2021","journal-title":"Neth. Heart J."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"804","DOI":"10.4244\/EIJ-D-16-00927","article-title":"Impact of pulmonary hypertension on in-hospital outcome after surgical or transcatheter aortic valve replacement","volume":"13","author":"Gutmann","year":"2017","journal-title":"EuroIntervention"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"123","DOI":"10.14740\/cr480w","article-title":"Predictors of Permanent Pacemaker Implantation After Coronary Artery Bypass Grafting and Valve Surgery in Adult Patients in Current Surgical Era","volume":"7","author":"Mallawi","year":"2016","journal-title":"Cardiol. Res."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1111\/pace.12569","article-title":"Permanent pacemaker insertion following isolated aortic valve replacement before and after the introduction of TAVI","volume":"38","author":"Kogan","year":"2015","journal-title":"Pacing Clin. Electrophysiol."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1016\/j.athoracsur.2018.02.041","article-title":"Need for Permanent Pacemaker After Surgical Aortic Valve Replacement Reduces Long-Term Survival","volume":"106","author":"Mehaffey","year":"2018","journal-title":"Ann. Thorac. Surg."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1259","DOI":"10.1016\/j.athoracsur.2017.01.083","article-title":"Long-Term Mortality Effect of Early Pacemaker Implantation After Surgical Aortic Valve Replacement","volume":"104","author":"Greason","year":"2017","journal-title":"Ann. Thorac. Surg."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1016\/j.amjcard.2020.10.010","article-title":"Relation of Prolonged Pacemaker Dependency After Cardiac Surgery to Mortality","volume":"138","author":"Lorusso","year":"2020","journal-title":"Am. J. Cardiol."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1111\/j.1540-8159.2010.02972.x","article-title":"Long-term mortality and pacing outcomes of patients with permanent pacemaker implantation after cardiac surgery","volume":"34","author":"Raza","year":"2011","journal-title":"Pacing Clin. Electrophysiol."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"4301","DOI":"10.1111\/jocs.16936","article-title":"Outcome of permanent pacemaker implantation in transcatheter or surgical aortic valve replacement: A still unsolved problem","volume":"37","author":"Totaro","year":"2022","journal-title":"J. Card. Surg."}],"container-title":["Journal of Cardiovascular Development and Disease"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2308-3425\/11\/12\/397\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T16:51:55Z","timestamp":1760115115000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2308-3425\/11\/12\/397"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,11]]},"references-count":35,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["jcdd11120397"],"URL":"https:\/\/doi.org\/10.3390\/jcdd11120397","relation":{},"ISSN":["2308-3425"],"issn-type":[{"value":"2308-3425","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,11]]}}}