{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T09:07:08Z","timestamp":1779959228084,"version":"3.53.1"},"reference-count":37,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T00:00:00Z","timestamp":1779926400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCDD"],"abstract":"<jats:p>Background: An aorto-right ventricular fistula (ARVF) secondary to membranous septum rupture is an exceptionally rare complication after surgical aortic valve replacement (SAVR). While sutureless prostheses such as the Perceval valve have gained wide acceptance due to reduced cross-clamp times and procedural simplification, the reported adverse events predominantly include conduction disturbances and paravalvular leaks. Structural septal disruption remains sparsely described. We report a case of an early ARVF after Perceval implantation and review the pathophysiological and procedural mechanisms implicated in septal injury following sutureless and transcatheter aortic valve interventions. Case Description: A 66-year-old woman with severe bicuspid aortic valve stenosis underwent SAVR via a median sternotomy using a Perceval XL prosthesis after meticulous annular decalcification and sizing. Immediate intraoperative transesophageal echocardiography (TEE) confirmed optimal seating without any paravalvular regurgitation. Within 24 h, the patient developed a complete atrioventricular block followed by cardiogenic shock. A repeat TEE revealed a large ARVF with significant left-to-right shunt. Emergent re-exploration identified a membranous septum tear. The Perceval prosthesis was explanted, the defect was closed with a reinforced patch repair, and a 27 mm Inspiris Resilia bioprosthesis was implanted. Peripheral veno-arterial ECMO support was required temporarily. The patient recovered and remained free of prosthetic dysfunction at the two-year follow-up. Discussion: Membranous septum rupture after AVR has an estimated incidence of 0.4\u20131.5% in TAVR cohorts but is virtually unreported with Perceval valves. The mechanisms are thought to be chronic radial stress from oversized or malpositioned prostheses. Case reports with TAVR devices emphasize oversizing as a risk factor. Predictive factors for septal injury in sutureless AVR mirror those for conduction disturbances: valve oversizing, shallow infra-annular septal length, heavy calcification, and prior valve surgery. Preventive measures, such as strict sizing protocols, the avoidance of balloon dilation, and optimized implantation depth, have reduced conduction complications and may mitigate septal trauma. The treatment choice, whether percutaneous or surgical closure, depends on hemodynamic stability, defect size and anatomy, and operative risk. Conclusions: Early ARVF after Perceval implantation is exceedingly rare but potentially catastrophic. Strict adherence to sizing principles, awareness of septal anatomy, and prompt management, percutaneous in selected stable cases or surgical in acute large defects, are essential to optimize outcomes in sutureless AVR.<\/jats:p>","DOI":"10.3390\/jcdd13060230","type":"journal-article","created":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T08:00:36Z","timestamp":1779955236000},"page":"230","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["A Word of Caution: Aorto-Right Ventricular Fistula, an Uncommon Pitfall of Perceval Sutureless Valve"],"prefix":"10.3390","volume":"13","author":[{"given":"Ziyad","family":"Gunga","sequence":"first","affiliation":[{"name":"Department of Cardiovascular Surgery, Lausanne University Hospital (CHUV), 1011 Lausanne, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0004-0517-666X","authenticated-orcid":false,"given":"Augustin","family":"Rigollot","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Lausanne University Hospital (CHUV), 1011 Lausanne, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-9362-9401","authenticated-orcid":false,"given":"Elsa","family":"Hoti","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Lausanne University Hospital (CHUV), 1011 Lausanne, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9199-4415","authenticated-orcid":false,"given":"Zied","family":"Ltaief","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Intensive Care, Lausanne University Hospital (CHUV), 1011 Lausanne, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gabriel","family":"Saiydoun","sequence":"additional","affiliation":[{"name":"Department of Cardiac and Thoracic Surgery, Piti\u00e9-Salp\u00eatri\u00e8re University Hospital, Assistance Publique des H\u00f4pitaux de Paris, 75013 Paris, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna","family":"Nowacka","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Lausanne University Hospital (CHUV), 1011 Lausanne, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Valentina","family":"Rancati","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Intensive Care, Lausanne University Hospital (CHUV), 1011 Lausanne, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Florine","family":"Valliet","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Lausanne University Hospital (CHUV), 1011 Lausanne, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9213-7578","authenticated-orcid":false,"given":"Matthias","family":"Kirsch","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Lausanne University Hospital (CHUV), 1011 Lausanne, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,5,28]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"920","DOI":"10.1016\/j.jtcvs.2020.11.162","article-title":"Sutureless versus conventional bioprostheses for aortic valve replacement in severe symptomatic aortic valve stenosis","volume":"161","author":"Fischlein","year":"2021","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1097\/imi.0000000000000372","article-title":"The Perceval Sutureless Aortic Valve: Review of Outcomes, Complications, and Future Direction","volume":"12","author":"Powell","year":"2017","journal-title":"Innov. Technol. Tech. Cardiothorac. Vasc. Surg."},{"key":"ref_3","first-page":"975","article-title":"Incidence of acquired ventricular septal defect after transcatheter aortic valve replacement: A large single center experience","volume":"98","author":"Nona","year":"2021","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1080\/24748706.2018.1434580","article-title":"Ventricular Septal Defect as a Complication of TAVI: Mechanism and Incidence","volume":"2","author":"Zeniou","year":"2018","journal-title":"Struct. Heart"},{"key":"ref_5","first-page":"414","article-title":"Ventricular Septal Defect as an Unusual Complication of Percutaneous Transcatheter Implantation of an Aortic Valve Prosthesis: Two-year Follow-up","volume":"67","year":"2014","journal-title":"Rev. Esp. Cardiol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"361","DOI":"10.33963\/KP.a2022.0009","article-title":"Rupture of the membranous septum and aortic root perforation after transcatheter aortic valve implantation successfully treated by surgery","volume":"80","author":"Hudziak","year":"2022","journal-title":"Pol. Heart J. (Kardiol. Pol.)"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1093\/eurheartj\/ehr197","article-title":"Interventricular septum rupture after transcatheter aortic valve implantation","volume":"33","year":"2012","journal-title":"Eur. Heart J."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"329","DOI":"10.14503\/THIJ-15-5083","article-title":"Transcatheter Closure of Iatrogenic VSDs after Aortic Valve Replacement Surgery: 2 Case Reports and a Literature Review","volume":"43","author":"Taleyratne","year":"2016","journal-title":"Tex. Heart Inst. J."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"982","DOI":"10.4244\/EIJV8I8A148","article-title":"How should I treat a perimembranous interventricular defect following aortic valve replacement surgery?","volume":"8","author":"Coceani","year":"2012","journal-title":"EuroIntervention"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"719.e1","DOI":"10.1016\/j.repc.2022.06.009","article-title":"Aortic annulus rupture with fistula to the right ventricle following aortic valve replacement with a sutureless valve: A surgical complication with a percutaneous solution","volume":"41","author":"Francisco","year":"2022","journal-title":"Rev. Port. Cardiol."},{"key":"ref_11","first-page":"63","article-title":"Sutureless Aortic Valve Replacement: A Canadian Multicentre Study","volume":"31","author":"Mazine","year":"2015","journal-title":"Can. J. Cardiol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"87","DOI":"10.21037\/jovs.2018.03.10","article-title":"Ten-year experience with the Perceval S sutureless prosthesis: Lessons learned and future perspectives","volume":"4","author":"Chauvette","year":"2018","journal-title":"J. Vis. Surg."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/j.jtcvs.2020.07.072","article-title":"Membranous septum length predicts conduction disturbances following transcatheter aortic valve replacement","volume":"164","author":"Chen","year":"2022","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1061","DOI":"10.4244\/EIJ-D-21-00363","article-title":"Membranous septum morphology and risk of conduction abnormalities after transcatheter aortic valve implantation","volume":"17","author":"Hansson","year":"2022","journal-title":"EuroIntervention"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1218","DOI":"10.1016\/j.jcin.2015.05.010","article-title":"Inverse Relationship Between Membranous Septal Length and the Risk of Atrioventricular Block in Patients Undergoing Transcatheter Aortic Valve Implantation","volume":"8","author":"Hamdan","year":"2015","journal-title":"JACC Cardiovasc. Interv."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"ivac157","DOI":"10.1093\/icvts\/ivac157","article-title":"Avoiding oversizing in sutureless valves leads to lower transvalvular gradients and less permanent pacemaker implants postoperatively","volume":"35","author":"Szecel","year":"2022","journal-title":"Interact. Cardiovasc. Thorac. Surg."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/j.athoracsur.2017.12.044","article-title":"Increased Gradients After Aortic Valve Replacement with the Perceval Valve: The Role of Oversizing","volume":"106","author":"Cerillo","year":"2018","journal-title":"Ann. Thorac. Surgery."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1177\/15569845231190881","article-title":"Sutureless Perceval Valve: Size Matters","volume":"18","author":"Elmously","year":"2023","journal-title":"Innov. Technol. Tech. Cardiothorac. Vasc. Surg."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1177\/1556984520938897","article-title":"Oversizing Increases Pacemaker Implantation Rate After Sutureless Minimally Invasive Aortic Valve Replacement","volume":"15","author":"Glauber","year":"2020","journal-title":"Innov. Technol. Tech. Cardiothorac. Vasc. Surg."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Margaryan, R., Concistre, G., Bianchi, G., and Solinas, M. (2024). Novel Perceval Sizing Technique: Single Center Experience. medRxiv, medRxiv:2024.08.06.24311534.","DOI":"10.1101\/2024.08.06.24311534"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"ivac182","DOI":"10.1093\/icvts\/ivac182","article-title":"Recent improvement in operative techniques lead to lower pacemaker rate after Perceval implant","volume":"35","author":"Fabre","year":"2022","journal-title":"Interact. Cardiovasc. Thorac. Surg."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/j.xjtc.2023.04.002","article-title":"Repositioning of the membranous septum to minimize pacemaker implantation after sutureless surgical aortic valve replacement","volume":"19","author":"Ueki","year":"2023","journal-title":"JTCVS Tech."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1016\/j.jmbbm.2017.02.006","article-title":"Understanding the requirements of self-expandable stents for heart valve replacement: Radial force, hoop force and equilibrium","volume":"68","author":"Cabrera","year":"2017","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"104772","DOI":"10.1016\/j.jmbbm.2021.104772","article-title":"Finite element analysis of transcatheter aortic valve implantation: Insights on the modelling of self-expandable devices","volume":"123","author":"Finotello","year":"2021","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"e1588","DOI":"10.4244\/EIJ-D-19-00115","article-title":"Transcatheter aortic valve implantation with the Portico and Evolut R bioprostheses in patients with elliptic aortic annulus","volume":"15","author":"Gorla","year":"2020","journal-title":"EuroIntervention"},{"key":"ref_26","first-page":"688.e9","article-title":"Aorto-Right Atrial Fistula After Sutureless Valve Implantation","volume":"33","author":"Luc","year":"2017","journal-title":"Can. J. Cardiol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"bcr2017219247","DOI":"10.1136\/bcr-2017-219247","article-title":"Aorto-right ventricular fistula following transcatheter aortic valve implantation using a 29 mm SAPIEN XT valve","volume":"2017","author":"Hagiwara","year":"2017","journal-title":"BMJ Case Rep."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1128","DOI":"10.1161\/01.CIR.20.6.1128","article-title":"An Aortic-Right Ventricular Fistula of More than Eighteen Months\u2019 Duration","volume":"20","author":"Bronk","year":"1959","journal-title":"Circulation"},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Paglianiti, D.A., Aurigemma, C., Busco, M., Cappannoli, L., Bianchini, F., Romagnoli, E., Lunardi, M., Fracassi, F., Paraggio, L., and Buffon, A. (2025). TAVI for Bicuspid Aortic Valve: Addressing Technical Challenges and Optimizing Outcomes. J. Clin. Med., 14.","DOI":"10.3390\/jcm14217860"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1195","DOI":"10.1016\/j.jacc.2016.06.041","article-title":"Transcatheter Aortic Valve Replacement with Early- and New-Generation Devices in Bicuspid Aortic Valve Stenosis","volume":"68","author":"Yoon","year":"2016","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1093\/ejcts\/ezv369","article-title":"Sutureless, rapid deployment valves and stented bioprosthesis in aortic valve replacement: Recommendations of an International Expert Consensus Panel","volume":"49","author":"Gersak","year":"2016","journal-title":"Eur. J. Cardiothorac. Surg."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"298","DOI":"10.21037\/acs-2020-surd-33","article-title":"Sutureless and rapid deployment implantation in bicuspid aortic valve: Results from the Sutureless and Rapid-Deployment Aortic Valve Replacement International Registry","volume":"9","author":"Miceli","year":"2020","journal-title":"Ann. Cardiothorac. Surg."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"721.e1","DOI":"10.1016\/j.repc.2022.06.010","article-title":"The heart valve team: It goes both ways","volume":"41","author":"Magro","year":"2022","journal-title":"Rev. Port. Cardiol."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"119","DOI":"10.4330\/wjc.v10.i9.119","article-title":"Snugger method\u2014The Oldenburg modification of perceval implantation technique","volume":"10","author":"Mashhour","year":"2018","journal-title":"World J. Cardiol."},{"key":"ref_35","unstructured":"SORIN Group (2025, May 11). Perceval Sutureless Aortic Heart Valve, Instructions for Use, Available online: https:\/\/www.accessdata.fda.gov\/cdrh_docs\/pdf15\/P150011d.pdf."},{"key":"ref_36","first-page":"33040","article-title":"Sutureless and rapid deployment valves: Implantation technique from A to Z\u2014The Perceval valve","volume":"9","author":"Glauber","year":"2020","journal-title":"Ann. Cardiothorac. Surg."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"e223","DOI":"10.1016\/j.athoracsur.2018.08.091","article-title":"Perceval Valve Implantation: Technical Details and Echocardiographic Assessment","volume":"107","author":"Vasanthan","year":"2019","journal-title":"Ann. Thorac. Surg."}],"container-title":["Journal of Cardiovascular Development and Disease"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2308-3425\/13\/6\/230\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T08:42:56Z","timestamp":1779957776000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2308-3425\/13\/6\/230"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,28]]},"references-count":37,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2026,6]]}},"alternative-id":["jcdd13060230"],"URL":"https:\/\/doi.org\/10.3390\/jcdd13060230","relation":{},"ISSN":["2308-3425"],"issn-type":[{"value":"2308-3425","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,28]]}}}