{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,11]],"date-time":"2026-02-11T03:02:21Z","timestamp":1770778941395,"version":"3.50.0"},"reference-count":42,"publisher":"MDPI AG","issue":"9","license":[{"start":{"date-parts":[[2021,4,28]],"date-time":"2021-04-28T00:00:00Z","timestamp":1619568000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>(1) Purpose: To assess the main corneal response differences between normal and subclinical keratoconus (SCKC) with a Corvis\u00ae ST device. (2) Material and Methods: We selected 183 eyes of normal patients, of a mean age of 33 \u00b1 9 years and 16 eyes of patients with SCKC of a similar mean age. We measured best corrected visual acuity (BCVA) and corneal topography with a Pentacam HD device to select the SCKC group. Biomechanical measurements were performed using the Corvis\u00ae ST device. We carried out a non-parametric analysis of the data with SPSS software (Wilcoxon signed rank-test). (3) Results: We found statistically significant differences between the control and SCKC groups in some corneal biomechanical parameters: first and second applanation time (p = 0.05 and p = 0.02), maximum deformation amplitude (p = 0.016), highest concavity radius (p = 0.007), and second applanation length and corneal velocity ((p = 0.039 and p = 0.016). (4) Conclusions: Our results show that the use of normalised biomechanical parameters provided by noncontact tonometry, combined with a discriminant function theory, is a useful tool for detecting subclinical keratoconus.<\/jats:p>","DOI":"10.3390\/jcm10091905","type":"journal-article","created":{"date-parts":[[2021,4,28]],"date-time":"2021-04-28T10:41:58Z","timestamp":1619606518000},"page":"1905","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Evaluation of Intraocular Pressure and Other Biomechanical Parameters to Distinguish between Subclinical Keratoconus and Healthy Corneas"],"prefix":"10.3390","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5992-5006","authenticated-orcid":false,"given":"Cristina","family":"Peris-Mart\u00ednez","sequence":"first","affiliation":[{"name":"FISABIO Oftalmolog\u00eda M\u00e9dica (FOM), Anterior Segment and Cornea and External Eye Diseases Unit, Bifurcaci\u00f3n P\u00edo Baroja-General Avil\u00e9s, 12, E-46015 Valencia, Spain"},{"name":"Surgery Department, Ophthalmology, School of Medicine, University of Valencia, Av. Blasco Ib\u00e1\u00f1ez, 15, E-46010 Valencia, Spain"},{"name":"Avi\u00f1o Peris Eye Clinic, Avinguda de l\u2019Oest, 34, E-46001 Valencia, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8146-4039","authenticated-orcid":false,"given":"Mar\u00eda Amparo","family":"D\u00edez-Ajenjo","sequence":"additional","affiliation":[{"name":"FISABIO Oftalmolog\u00eda M\u00e9dica (FOM), Anterior Segment and Cornea and External Eye Diseases Unit, Bifurcaci\u00f3n P\u00edo Baroja-General Avil\u00e9s, 12, E-46015 Valencia, Spain"},{"name":"Optics, Optometry and Vision Sciences Department, School of Physics, University of Valencia, Dr. Moliner, 50, E-46100 Valencia, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8736-0214","authenticated-orcid":false,"given":"Mar\u00eda Carmen","family":"Garc\u00eda-Domene","sequence":"additional","affiliation":[{"name":"FISABIO Oftalmolog\u00eda M\u00e9dica (FOM), Anterior Segment and Cornea and External Eye Diseases Unit, Bifurcaci\u00f3n P\u00edo Baroja-General Avil\u00e9s, 12, E-46015 Valencia, Spain"},{"name":"Optics, Optometry and Vision Sciences Department, School of Physics, University of Valencia, Dr. Moliner, 50, E-46100 Valencia, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0118-7837","authenticated-orcid":false,"given":"Mar\u00eda Dolores","family":"Pinazo-Dur\u00e1n","sequence":"additional","affiliation":[{"name":"Surgery Department, Ophthalmology, School of Medicine, University of Valencia, Av. Blasco Ib\u00e1\u00f1ez, 15, E-46010 Valencia, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5918-8429","authenticated-orcid":false,"given":"Mar\u00eda Jos\u00e9","family":"Luque-Cobija","sequence":"additional","affiliation":[{"name":"FISABIO Oftalmolog\u00eda M\u00e9dica (FOM), Anterior Segment and Cornea and External Eye Diseases Unit, Bifurcaci\u00f3n P\u00edo Baroja-General Avil\u00e9s, 12, E-46015 Valencia, Spain"},{"name":"Optics, Optometry and Vision Sciences Department, School of Physics, University of Valencia, Dr. Moliner, 50, E-46100 Valencia, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6721-9125","authenticated-orcid":false,"given":"Mar\u00eda \u00c1ngeles","family":"del Buey-Sayas","sequence":"additional","affiliation":[{"name":"Hospital Lozano Blesa, Anterior Segment and Cornea and External Eye Diseases, E-46015 Zaragoza, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Susana","family":"Ort\u00ed-Navarro","sequence":"additional","affiliation":[{"name":"Optics, Optometry and Vision Sciences Department, School of Physics, University of Valencia, Dr. Moliner, 50, E-46100 Valencia, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2021,4,28]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1016\/S0014-4835(03)00148-9","article-title":"Involvement of corneal nerves in the progression of keratoconus","volume":"77","author":"Brookes","year":"2003","journal-title":"Exp. Eye Res."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1016\/S0002-9394(02)01698-7","article-title":"Keratocyte density in keratoconus. A confocal microscopy study","volume":"134","author":"Erie","year":"2002","journal-title":"Am. J. Ophthalmol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1948","DOI":"10.1167\/iovs.04-1253","article-title":"Changes in Collagen Orientation and Distribution in Keratoconus Corneas","volume":"46","author":"Meek","year":"2005","journal-title":"Investig. Opthalmol. Vis. Sci."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1097\/IIO.0000000000000172","article-title":"Biomechanical Diagnostics of the Cornea","volume":"57","author":"Esporcatte","year":"2017","journal-title":"Int. Ophthalmol. Clin. Summer"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1111\/cxo.12211","article-title":"Biomechanical properties of the keratoconic cornea: A review","volume":"98","author":"Vellara","year":"2015","journal-title":"Clin. Exp. Optom."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1016\/S0014-4835(88)80031-9","article-title":"Comparative studies of collagens in normal and keratoconus corneas","volume":"46","author":"Zimmermann","year":"1988","journal-title":"Exp. Eye Res."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"778","DOI":"10.1016\/j.jcrs.2018.12.015","article-title":"Assessment of corneal biomechanical parameters in healthy and keratoconic eyes using dynamic bidirectional applanation device and dynamic Scheimpflug analyzer","volume":"45","author":"Herber","year":"2019","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/j.jcrs.2004.10.044","article-title":"Determining in vivo biomechanical properties of the cornea with an ocular response analyzer","volume":"31","author":"Luce","year":"2005","journal-title":"J. Cataract. Refract. Surg."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"3026","DOI":"10.1167\/iovs.04-0694","article-title":"Assessment of the biomechanical properties of the cornea with the ocular re-sponse analyzer in normal and keratoconic eyes","volume":"48","author":"Shah","year":"2007","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"202","DOI":"10.3928\/1081597X-20120103-03","article-title":"Improved keratoconus detection by ocular response analyzer testing after considera-tion of corneal thickness as a confounding factor","volume":"28","author":"Galletti","year":"2012","journal-title":"J. Refract. Surg."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1097\/ICO.0b013e3182490924","article-title":"Biomechanical Evaluation of Cornea in Topographically Normal Relatives of Patients with Keratoconus","volume":"32","author":"Kara","year":"2013","journal-title":"Cornea"},{"key":"ref_12","first-page":"881","article-title":"Examination and discriminant analysis of corneal biomechanics with CorVis ST in keratoconus and subclinical keratoconus","volume":"51","author":"Wu","year":"2019","journal-title":"Beijing Da Xue Xue Bao Yi Xue Ban"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"15379","DOI":"10.1038\/s41598-019-51502-4","article-title":"Repeatability and comparison of new Corvis\u00ae ST parameters in normal and keratoconus eyes","volume":"9","author":"Yang","year":"2019","journal-title":"Sci. Rep."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"5676","DOI":"10.1038\/s41598-020-62825-y","article-title":"Evaluation of new Corvis\u00ae ST parameters in normal, Post-LASIK, Post-LASIK keratectasia and keratoconus eyes","volume":"10","author":"Yang","year":"2020","journal-title":"Sci. Rep."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1016\/j.joco.2017.05.002","article-title":"Keratoconus diagnosis using Corvis\u00ae ST measured biomechanical parameters","volume":"29","author":"Elham","year":"2017","journal-title":"J. Curr. Ophthalmol."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"740","DOI":"10.3389\/fphys.2019.00740","article-title":"Relationship Among Corneal Stiffness, Thickness, and Biomechanical Parameters Measured by Corvis\u00ae ST, Pentacam and ORA in Keratoconus","volume":"10","author":"Zhao","year":"2019","journal-title":"Front. Physiol."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1080\/02713683.2019.1658787","article-title":"Early Diagnosis of Keratoconus in Chinese Myopic Eyes by Combining Corvis\u00ae ST with Pen-tacam","volume":"45","author":"Zhang","year":"2020","journal-title":"Curr. Eye Res."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"247","DOI":"10.3928\/1081597X-20190226-01","article-title":"Biomechanical Analysis of Subclinical Keratoconus With Normal Topographic, Topometric, and Tomographic Findings","volume":"35","author":"Koc","year":"2019","journal-title":"J. Refract. Surg."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"616","DOI":"10.3928\/1081597X-20180705-02","article-title":"Comparison of Corneal Tomography and a New Combined Tomographic Biomechanical Index in Subclinical Keratoconus","volume":"34","author":"Chan","year":"2018","journal-title":"J. Refract. Surg."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"840","DOI":"10.3928\/1081597X-20181012-01","article-title":"Tomographic and Biomechanical Scheimpflug Imaging for Keratoconus Characterization: A Validation of Current Indices","volume":"34","author":"Steinberg","year":"2018","journal-title":"J. Refract. Surg."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"383","DOI":"10.3928\/1081597X-20190417-01","article-title":"Detection of Subclinical Corneal Ectasia Using Corneal Tomographic and Biomechanical Assessments in a Japanese Population","volume":"35","author":"Koh","year":"2019","journal-title":"J. Refract. Surg."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"608","DOI":"10.1097\/OPX.0000000000001241","article-title":"Corneal Biomechanics in Unilateral Keratoconus and Fellow Eyes with a Scheimpflug-based Tonometer","volume":"95","year":"2018","journal-title":"Optom. Vis. Sci."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1748579","DOI":"10.1155\/2019\/1748579","article-title":"Assessment of Corneal Pachymetry Distribution and Morphologic Changes in Subclinical Kerato-conus with Normal Biomechanics","volume":"2019","author":"Song","year":"2019","journal-title":"Biomed. Res. Int."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1590\/S0004-27492013000400008","article-title":"Effects of age on corneal deformation by non-contact tonometry integrated with an ultra-high-speed (UHS) Scheimpflug camera","volume":"76","author":"Valbon","year":"2013","journal-title":"Arq. Bras. Oftalmol."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"558","DOI":"10.3928\/1081597X-20130719-06","article-title":"Repeatability of Ocular Biomechanical Data Measurements with a Scheimpflug-Based Noncontact Device on Normal Corneas","volume":"29","author":"Nemeth","year":"2013","journal-title":"J. Refract. Surg."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1167\/iovs.12-10984","article-title":"A New Tonometer\u2014The Corvis\u00ae ST Tonometer: Clinical Comparison with Noncontact and Goldmann Applanation Tonometers","volume":"54","author":"Hong","year":"2013","journal-title":"Investig. Opthalmol. Vis. Sci."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1097\/OPX.0b013e318279eb87","article-title":"Corneal deformation measurement using Scheimpflug noncontact tonometry","volume":"90","author":"Hon","year":"2013","journal-title":"Optom. Vis. Sci."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"881","DOI":"10.1097\/ICO.0000000000001605","article-title":"Corneal Stiffness and Its Relationship with Other Corneal Biomechanical and Nonbiomechan-ical Parameters in Myopic Eyes of Chinese Patients","volume":"37","author":"Zhang","year":"2018","journal-title":"Cornea"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"399","DOI":"10.3928\/1081597X-20170213-01","article-title":"Biomechanical Characterization of Subclinical Keratoconus Without Topo-graphic or Tomographic Abnormalities","volume":"33","author":"Vinciguerra","year":"2017","journal-title":"J. Refract. Surg."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1016\/j.jbiomech.2015.12.031","article-title":"Detection of subclinical keratoconus through non-contacttonometry and the use of discriminant biomechanical functions","volume":"49","author":"Abbouda","year":"2016","journal-title":"J. Biomech."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"849","DOI":"10.1097\/ICO.0b013e318243e42d","article-title":"Changes of Corneal Biomechanics with Keratoconus","volume":"31","author":"Wolffsohn","year":"2012","journal-title":"Cornea"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/j.ajo.2013.03.034","article-title":"Detection of subclinical kerato-conus using an automated decision tree classification","volume":"156","author":"Smadja","year":"2013","journal-title":"Am. J. Ophthalmol."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1136\/bjo.2008.147371","article-title":"Chasing the suspect: Keratoconus","volume":"93","author":"Klyce","year":"2009","journal-title":"Br. J. Ophthalmol."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1097\/IIO.0b013e31820f1d2d","article-title":"Evaluation of corneal shape and biomechanics before LASIK","volume":"51","author":"Nogueira","year":"2011","journal-title":"Int. Ophthalmol. Clin."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1136\/bjophthalmol-2013-304132","article-title":"Evaluation of corneal elevation, pachymetry and keratometry in keratoconic eyes with respect to the stage of Amsler-Krumeich classification","volume":"98","author":"Kamiya","year":"2014","journal-title":"Br. J. Ophthalmol."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"1470","DOI":"10.1097\/ICO.0b013e3182a7387f","article-title":"Mapping corneal thickness using dual-scheimpflug imaging at different stages of kerato-conus","volume":"32","author":"Demir","year":"2013","journal-title":"Cornea"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"976","DOI":"10.1097\/ICO.0b013e31819e34de","article-title":"Evaluation of keratometric, pachymetric, and elevation parameters of keratoconus cor-neas with pentacam","volume":"28","author":"Nagy","year":"2009","journal-title":"Cornea"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"1534","DOI":"10.1016\/j.ophtha.2008.02.020","article-title":"Sensitivity and specificity of posterior corneal elevation measured by Pentacam in discriminating keratoconus\/subclinical keratoconus","volume":"115","author":"Loiacono","year":"2008","journal-title":"Ophthalmology"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"637","DOI":"10.3928\/1081597X-20130819-05","article-title":"Analysis of waveform-derived ORA parameters in early forms of kerato-conus and normal corneas","volume":"29","author":"Ventura","year":"2013","journal-title":"J. Refract. Surg."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"147516","DOI":"10.1155\/2014\/147516","article-title":"Corneal Biomechanical Assessment Using Corneal Visualization Scheimpflug Technology in Keratoconic and Normal Eyes","volume":"2014","author":"Tian","year":"2014","journal-title":"J. Ophthalmol."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"2367","DOI":"10.1016\/j.jbiomech.2006.12.001","article-title":"Stress-controlled viscoelastic tensile response of bovine cornea","volume":"40","author":"Boyce","year":"2007","journal-title":"J. Biomech."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1590\/S0004-27492013000200011","article-title":"ORA waveform-derived biomechanical parameters to distinguish normal from ker-atoconic eyes","volume":"76","author":"Luz","year":"2013","journal-title":"Arq. Bras. Oftalmol."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/10\/9\/1905\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T05:54:36Z","timestamp":1760162076000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/10\/9\/1905"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,4,28]]},"references-count":42,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2021,5]]}},"alternative-id":["jcm10091905"],"URL":"https:\/\/doi.org\/10.3390\/jcm10091905","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,4,28]]}}}