{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T02:53:57Z","timestamp":1788836037515,"version":"build-2803163510"},"reference-count":49,"publisher":"MDPI AG","issue":"15","license":[{"start":{"date-parts":[[2021,7,24]],"date-time":"2021-07-24T00:00:00Z","timestamp":1627084800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>This semi-prospective, parallel, comparative investigation evaluated the clinical outcomes and quality of vision (contrast sensitivity, visual function, dysphotopsia, spectacle use, overall satisfaction) after mono- or bilateral implantation of two presbyopia-correcting intraocular lenses (IOL)\u2014the Liberty\u00ae 677MY or the AT LISA\u00ae tri 839M\u2014in 50 eyes of 25 cataract patients. Clinical outcomes were assessed 3 and 12 months postoperatively. Eighty-nine percent of eyes implanted with the Liberty IOL and 59% of eyes implanted with the AT LISA IOL achieved a refractive outcome \u00b10.5 diopters of the target (emmetropia). Refractive outcomes were stable with both lenses. The proportions of eyes with 20\/20 uncorrected distance visual acuity (UDVA) and 20\/20 uncorrected near visual acuity (UNVA) were higher in the Liberty group than in the AT LISA group (UDVA: 56% vs. 41%; UNVA: 83% vs. 66%). Optical quality assessment results were comparable for the two IOLs. Superior photopic contrast sensitivity was found with the Liberty lens. The rate of Nd:YAG capsulotomy at the 12-month follow-up was 16.7% in the Liberty group and 40.6% for the AT LISA IOL. Considering that both lenses are made from the same material, we propose that the noted differences in clinical outcomes may derive from differences in design and optical surface between the two IOLs.<\/jats:p>","DOI":"10.3390\/jcm10153268","type":"journal-article","created":{"date-parts":[[2021,7,25]],"date-time":"2021-07-25T22:06:21Z","timestamp":1627250781000},"page":"3268","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Comparison of Clinical Outcomes, Visual Quality and Visual Function of Two Presbyopia-Correcting Intraocular Lenses Made from the Same Material, but with Different Design and Optics"],"prefix":"10.3390","volume":"10","author":[{"given":"Ladislav Viktor","family":"Nov\u00e1\u010dek","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Institute of Aviation Medicine Prague, 160 00 Prague, Czech Republic"},{"name":"Department of Ophthalmology, 1st Faculty of Medicine, Charles University and the Military University Hospital Prague, 121 08 Prague, Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marie","family":"N\u011bmcov\u00e1","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Institute of Aviation Medicine Prague, 160 00 Prague, Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kate\u0159ina","family":"Tyx","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Institute of Aviation Medicine Prague, 160 00 Prague, Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Krist\u00fdna","family":"Lahodov\u00e1","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Institute of Aviation Medicine Prague, 160 00 Prague, Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2424-3173","authenticated-orcid":false,"given":"Leo\u0161","family":"Rejmont","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, 1st Faculty of Medicine, Charles University and the Military University Hospital Prague, 121 08 Prague, Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pavel","family":"Rozs\u00edval","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Institute of Aviation Medicine Prague, 160 00 Prague, Czech Republic"},{"name":"Department of Ophthalmology Charles University Prague, School of Medicine Hradec Kr\u00e1lov\u00e9, 500 03 Hradec Kr\u00e1lov\u00e9, Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pavel","family":"Studen\u00fd","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, 1st Faculty of Medicine, Charles University and the Military University Hospital Prague, 121 08 Prague, Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2021,7,24]]},"reference":[{"key":"ref_1","unstructured":"(2020, November 05). ESCRS 2019 Clinical Trends Survey Results. EuroTimes, Available online: https:\/\/www.eurotimes.org\/wp-content\/uploads\/2020\/11\/Clinical-Survey-Results-2019-Supplement_PQ.pdf."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1635","DOI":"10.1038\/s41433-019-0460-9","article-title":"Which intraocular lens would ophthalmologists choose for themselves?","volume":"33","author":"Logothetis","year":"2019","journal-title":"Eye"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"e000064","DOI":"10.1136\/bmjophth-2016-000064","article-title":"Assessment of dysphotopsia in pseudophakic subjects with multifocal intraocular lenses","volume":"1","author":"Buckhurst","year":"2017","journal-title":"BMJ Open Ophthalmol."},{"key":"ref_4","unstructured":"Masket, S., and Fram, N.R. (2020). Pseudophakic Dysphotopsia: Review of Incidence, Cause, and Treatment of Positive and Negative Dysphotopsia. Ophthalmology, 30787\u201330789."},{"key":"ref_5","first-page":"857","article-title":"Posterior capsule opacification and Nd:YAG laser rates with two hydrophobic acrylic single-piece IOLs","volume":"5","author":"Schriefl","year":"2020","journal-title":"Eye"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"688","DOI":"10.5301\/ejo.5000452","article-title":"Comparison of visual quality between aspheric and spherical IOLs","volume":"5","author":"Yagci","year":"2014","journal-title":"Eur. J. Ophthalmol."},{"key":"ref_7","first-page":"1146","article-title":"Comparison of pseudophakic retinal straylight in spherical\/aspherical and hydrophobic\/hydrophilic intraocular lens","volume":"6","author":"Tang","year":"2015","journal-title":"Int. J. Ophthalmol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1473","DOI":"10.1016\/j.jcrs.2013.12.018","article-title":"Influence of intraocular lens haptic design on refractive error","volume":"9","author":"Savini","year":"2014","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1353","DOI":"10.1097\/j.jcrs.0000000000000259","article-title":"Comparison of the rotational stability between plate-haptic toric and C-loop haptic toric IOLs in myopic eyes","volume":"10","author":"Zhu","year":"2020","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1016\/j.jcrs.2016.01.014","article-title":"Efficacy and safety of multifocal intraocular lenses following cataract and refractive lens exchange: Metaanalysis of peer-reviewed publications","volume":"2","author":"Rosen","year":"2016","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_11","first-page":"2687385","article-title":"Biomaterial influence on intraocular lens performance: An overview","volume":"2018","year":"2018","journal-title":"J. Ophthalmol."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Masket, S., Rupnick, Z., Fram, N.R., Kwong, S., and McLachlan, J. (2020). Surgical management of positive dysphotopsia: U.S. perspective. J. Cataract Refract. Surg., 1474\u20131479.","DOI":"10.1097\/j.jcrs.0000000000000307"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"930","DOI":"10.3109\/02713683.2014.968936","article-title":"Prospective Comparison of One-Piece and Three-Piece Tecnis Aspheric Intraocular Lenses: 1-year Stability and its Effect on Visual Function","volume":"9","author":"Miyata","year":"2015","journal-title":"Curr. Eye Res."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"3237","DOI":"10.2147\/OPTH.S273641","article-title":"Comparison of Visual Performance and Patient Satisfaction Outcomes with Two Trifocal IOLs with Similar Optical Design but Different Materials","volume":"14","author":"Poyales","year":"2020","journal-title":"Clin. Ophthalmol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1976","DOI":"10.1016\/j.jcrs.2008.07.029","article-title":"Effect of intraocular lens design on posterior capsule opacification","volume":"11","author":"Buehl","year":"2008","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"267","DOI":"10.22336\/rjo.2017.48","article-title":"Posterior Capsule Opacification and Nd-YAG rates evaluation in a large series of pseudophakic cases","volume":"4","author":"Iliescu","year":"2017","journal-title":"Rom. J. Ophthalmol."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"2064","DOI":"10.1016\/j.jcrs.2004.05.003","article-title":"Adverse clinical consequences of neodymium:YAG laser treatment of posterior capsule opacification","volume":"10","author":"Billotte","year":"2004","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"World Medical Association (2013). World Medical Association Declaration of Helsinki: Ethical principles for medical research involving human subjects. JAMA, 20, 2191\u20132194.","DOI":"10.1001\/jama.2013.281053"},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Novacek, L. (2021). Comparison of clinical outcomes, visual quality and visual function of two presbyopia-correcting intraocular lenses made from the same material, but with different design and optics. Mendeley Data V1.","DOI":"10.3390\/jcm10153268"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1016\/j.jcrs.2017.04.005","article-title":"Standard for reporting refractive outcomes of intraocular lens-based refractive surgery","volume":"4","author":"Reinstein","year":"2017","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"364","DOI":"10.22336\/rjo.2020.58","article-title":"Comparison of three different presbyopia-correcting intraocular lenses","volume":"4","author":"Serdiuk","year":"2020","journal-title":"Rom. J. Ophthalmol."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1038\/s41433-018-0076-5","article-title":"Patient outcomes following implantation with a trifocal toric IOL: Twelve-month prospective multicentre study","volume":"1","author":"Piovella","year":"2019","journal-title":"Eye"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1016\/j.jcrs.2019.01.024","article-title":"Implantation of a diffractive-refractive trifocal intraocular lens with centralized diffractive rings: Two-year results","volume":"5","author":"Gyory","year":"2019","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_24","first-page":"998","article-title":"Biometric Factors Associated with the Visual Performance of a High Addition Multifocal Intraocular Lens","volume":"8","author":"Tauste","year":"2018","journal-title":"Curr. Eye Res."},{"key":"ref_25","first-page":"282","article-title":"Visual outcomes after progressive apodized diffractive intraocular lens implantation","volume":"3","year":"2018","journal-title":"Eur. J. Ophthalmol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"333","DOI":"10.3341\/kjo.2019.0001","article-title":"Effects of Bifocal versus Trifocal Diffractive Intraocular Lens Implantation on Visual Quality after Cataract Surgery","volume":"4","author":"Kim","year":"2019","journal-title":"Korean J. Ophthalmol."},{"key":"ref_27","first-page":"1534","article-title":"Multicenter visual outcomes comparison of 2 trifocal presbyopia-correcting IOLs: 6-month postoperative results","volume":"11","author":"Bhatt","year":"2020","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1097\/j.jcrs.0000000000000012","article-title":"Comparison of the intermediate distance of a trifocal IOL with an extended depth-of-focus IOL: Results of a prospective randomized trial","volume":"2","author":"Webers","year":"2020","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1623","DOI":"10.1016\/j.jcrs.2014.11.050","article-title":"Implantation of a diffractive trifocal intraocular lens: One-year follow-up","volume":"8","author":"Mojzis","year":"2015","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1016\/j.jcrs.2019.01.013","article-title":"Outcomes of combining a trifocal and a low-addition bifocal intraocular lens in patients seeking spectacle independence at all distances","volume":"5","author":"Tarib","year":"2019","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_31","first-page":"CD003169","article-title":"Multifocal versus monofocal intraocular lenses after cataract extraction","volume":"12","author":"Evans","year":"2016","journal-title":"Cochrane Database Syst. Rev."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"658","DOI":"10.3928\/1081597X-20150611-01","article-title":"Visual outcomes after cataract surgery: Multifocal versus monofocal intraocular lenses","volume":"10","author":"Shah","year":"2015","journal-title":"J. Refract. Surg."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1016\/j.survophthal.2019.02.012","article-title":"Multifocal versus monofocal intraocular lenses for age-related cataract patients: A system review and meta-analysis based on randomized controlled trials","volume":"5","author":"Cao","year":"2019","journal-title":"Surv. Ophthalmol."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"2040","DOI":"10.1016\/S0161-6420(00)00368-7","article-title":"Cataract extraction with multifocal intraocular lens implantation: A multinational clinical trial evaluating clinical, functional, and quality-of-life outcomes","volume":"11","author":"Javitt","year":"2000","journal-title":"Ophthalmology"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1016\/S0161-6420(97)30265-6","article-title":"Outcomes of cataract extraction with multifocal intraocular lens implantation: Functional status and quality of life","volume":"4","author":"Javitt","year":"1997","journal-title":"Ophthalmology"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"1244","DOI":"10.1016\/j.jcrs.2007.03.052","article-title":"Visual acuity and contrast sensitivity: AcrySof ReSTOR apodized diffractive versus AcrySof SA60AT monofocal intraocular lenses","volume":"7","author":"Vingolo","year":"2007","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_37","first-page":"859","article-title":"Dissatisfaction after implantation of multifocal intraocular lenses","volume":"5","author":"Webers","year":"2011","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"992","DOI":"10.1016\/j.jcrs.2009.01.031","article-title":"Dissatisfaction after multifocal intraocular lens implantation","volume":"6","author":"Woodward","year":"2009","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1186\/s40662-020-00186-3","article-title":"Decentration and tilt of plate-haptic multifocal intraocular lenses in myopic eyes","volume":"7","author":"Meng","year":"2020","journal-title":"Eye Vis."},{"key":"ref_40","doi-asserted-by":"crossref","unstructured":"Ashena, Z., Maqsood, S., Ahmed, S.N., and Nanavaty, M.A. (2020). Effect of Intraocular Lens Tilt and Decentration on Visual Acuity, Dysphotopsia and Wavefront Aberrations. Vision, 3.","DOI":"10.3390\/vision4030041"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1016\/j.ajo.2007.04.044","article-title":"Influence on posterior capsule opacification and visual function of intraocular lens optic material","volume":"144","author":"Hayashi","year":"2007","journal-title":"Am. J. Ophthalmol."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"1065","DOI":"10.1016\/j.jcrs.2007.02.022","article-title":"Contact inhibition of migrating lens epithelial cells at the capsuler bend created by a sharp-edged intraocular lens after cataract surgery","volume":"33","author":"Nishi","year":"2007","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"913","DOI":"10.1016\/j.ajo.2007.02.017","article-title":"Long-term effect of optic edge design in a silicone intraocular lens on posterior capsule opacification","volume":"143","author":"Buehl","year":"2007","journal-title":"Am. J. Ophthalmol."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1016\/j.ajo.2006.11.045","article-title":"Efficacy of different intraocular lens material and optic edge designs in preventing posterior capsular opacification: A meta-analysis","volume":"143","author":"Cheng","year":"2007","journal-title":"Am. J. Ophthalmol."},{"key":"ref_45","first-page":"CD003738","article-title":"Interventions for preventing posterior capsule opacification","volume":"17","author":"Findl","year":"2010","journal-title":"Cochrane Database Syst. Rev."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"100905","DOI":"10.1016\/j.preteyeres.2020.100905","article-title":"Posterior capsule opacification: What\u2019s in the bag?","volume":"82","author":"Wormstone","year":"2021","journal-title":"Prog. Retin. Eye Res."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"513","DOI":"10.3928\/1081597X-20150727-01","article-title":"Vector Analysis, Rotational Stability, and Visual Outcome after Implantation of a New Aspheric Toric IOL","volume":"8","author":"Bachernegg","year":"2015","journal-title":"J. Refract. Surg."},{"key":"ref_48","unstructured":"Gy\u0151ry, J.F. (2019, January 14\u201318). Long-term evaluation of contrast sensitivity prior to and after the implantation of the Liberty 677MY trifocal intraocular lens. Proceedings of the 37th ESCRS Congress, Paris, France. Abstract Number FP-298695."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"1020","DOI":"10.1097\/j.jcrs.0000000000000210","article-title":"Visual function and subjective perception of vision after bilateral implantation of monofocal and multifocal IOLs: A randomized controlled trial","volume":"7","author":"Law","year":"2020","journal-title":"J. Cataract Refract. Surg."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/10\/15\/3268\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T06:34:25Z","timestamp":1760164465000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/10\/15\/3268"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,7,24]]},"references-count":49,"journal-issue":{"issue":"15","published-online":{"date-parts":[[2021,8]]}},"alternative-id":["jcm10153268"],"URL":"https:\/\/doi.org\/10.3390\/jcm10153268","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,7,24]]}}}