{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,6]],"date-time":"2026-02-06T04:02:52Z","timestamp":1770350572933,"version":"3.49.0"},"reference-count":61,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2022,2,8]],"date-time":"2022-02-08T00:00:00Z","timestamp":1644278400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>In recent years, an increase in periprosthetic femur fractures has become apparent due to the increased number of hip replacements. In the case of Vancouver type B1 fractures, locking plate systems offer safe procedures. This study compared the distal lateral femur plate (LOQTEQ\u00ae, aap Implantate AG) with a standard L.I.S.S. LCP\u00ae (DePuy Synthes) regarding their biomechanical properties in fixation of periprosthetic femur fractures after hip arthroplasty. We hypothesized that the new LOQTEQ system has superior stability and durability in comparison. Eighteen artificial left femurs were randomized in two groups (Group A: LOQTEQ\u00ae; Group B: L.I.S.S. LCP\u00ae) and tested until failure. Failure was defined as 10\u00b0 varus deformity and catastrophic implant failure (loosening, breakage, progressive bending). Axial stiffness, loads of failure, cycles of failure, modes of failure were recorded. The axial stiffness in Group A with 73.4 N\/mm (SD +\/\u2212 3.0) was significantly higher (p = 0.001) than in Group B (40.7 N\/mm (SD +\/\u2212 2.8)). Group A resists more cycles than Group B until 10\u00b0 varus deformity. Catastrophic failure mode was plate breakage in Group A and bending in Group B. In conclusion, LOQTEQ\u00ae provides higher primary stability and tends to have higher durability.<\/jats:p>","DOI":"10.3390\/jcm11030892","type":"journal-article","created":{"date-parts":[[2022,2,8]],"date-time":"2022-02-08T23:37:48Z","timestamp":1644363468000},"page":"892","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["A New System for Periprosthetic Fracture Stabilization\u2014A Biomechanical Comparison"],"prefix":"10.3390","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4576-5707","authenticated-orcid":false,"given":"Daniel","family":"Rau","sequence":"first","affiliation":[{"name":"Center for Musculoskeletal Surgery, Charit\u00e9-University Medicine Berlin, 13353 Berlin, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gabriele","family":"Ru\u00dfow","sequence":"additional","affiliation":[{"name":"Center for Musculoskeletal Surgery, Charit\u00e9-University Medicine Berlin, 13353 Berlin, Germany"},{"name":"BIH-Julius Wolff Institute for Biomechanics and Musculoskeletal Regeneration, Charit\u00e9-University Medicine Berlin, 13353 Berlin, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7474-3948","authenticated-orcid":false,"given":"Mark","family":"Heyland","sequence":"additional","affiliation":[{"name":"BIH-Julius Wolff Institute for Biomechanics and Musculoskeletal Regeneration, Charit\u00e9-University Medicine Berlin, 13353 Berlin, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3329-6111","authenticated-orcid":false,"given":"Dag","family":"Wulsten","sequence":"additional","affiliation":[{"name":"BIH-Julius Wolff Institute for Biomechanics and Musculoskeletal Regeneration, Charit\u00e9-University Medicine Berlin, 13353 Berlin, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Clemens","family":"K\u00f6sters","sequence":"additional","affiliation":[{"name":"Department of Orthopedic, Trauma and Hand Surgery, Maria-Josef-Hospital Greven, 48268 Greven, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2962-2594","authenticated-orcid":false,"given":"Werner","family":"Schm\u00f6lz","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Traumatology, Medical University of Innsbruck, 6020 Innsbruck, Austria"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sven","family":"M\u00e4rdian","sequence":"additional","affiliation":[{"name":"Center for Musculoskeletal Surgery, Charit\u00e9-University Medicine Berlin, 13353 Berlin, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2022,2,8]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"487","DOI":"10.2106\/00004623-200004000-00004","article-title":"Charnley Total Hip Arthroplasty with Cement: Minimum twenty-five-year follow-up","volume":"82","author":"Callaghan","year":"2000","journal-title":"J. Bone Jt. Surg."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1508","DOI":"10.1016\/S0140-6736(07)60457-7","article-title":"The operation of the century: Total hip replacement","volume":"370","author":"Learmonth","year":"2007","journal-title":"Lancet"},{"key":"ref_3","first-page":"407","article-title":"Hip and knee replacement in Germany and the USA: Analysis of individual inpatient data from German and US hospitals for the years 2005 to 2011","volume":"111","author":"Wengler","year":"2014","journal-title":"Dtsch. Arztebl. Int."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"553","DOI":"10.1007\/s00402-016-2407-y","article-title":"The influence of the operation technique and implant used in the treatment of periprosthetic hip and interprosthetic femur fractures: A systematic literature review of 1571 cases","volume":"136","author":"Stoffel","year":"2016","journal-title":"Arch. Orthop. Trauma. Surg."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1302\/0301-620X.93B1.25087","article-title":"The risk of peri-prosthetic fracture after primary and revision total hip and knee replacement","volume":"93","author":"Meek","year":"2011","journal-title":"J. Bone Jt. Surgery. Br. Vol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"e167","DOI":"10.2106\/JBJS.M.00643","article-title":"Periprosthetic femoral fracture within two years after total hip replacement: Analysis of 437,629 operations in the nordic arthroplasty register association database","volume":"96","author":"Thien","year":"2014","journal-title":"J. Bone Jt. Surg. Am."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1035","DOI":"10.1016\/j.injury.2014.02.038","article-title":"Biomechanical evaluation of fracture fixation constructs using a variable-angle locked periprosthetic femur plate system","volume":"45","author":"Hoffmann","year":"2014","journal-title":"Injury"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1007\/s00113-003-0698-2","article-title":"Periprosthetic fractures: Classification, management, therapy","volume":"107","author":"Gruner","year":"2004","journal-title":"Unfallchirurg"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/S0030-5898(20)31735-1","article-title":"Femoral fractures associated with total hip arthroplasty","volume":"23","author":"Kavanagh","year":"1992","journal-title":"Orthop. Clin. N. Am."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1007\/s00113-003-0723-5","article-title":"Periprosthetic supracondylar femoral fractures: LISS or retrograde intramedullary nailing? Problems with the use of minimally invasive technique","volume":"107","author":"Wick","year":"2004","journal-title":"Unfallchirurg"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"208","DOI":"10.55095\/achot2011\/033","article-title":"Cerclage handling for improved fracture treatment. A biomechanical study on the twisting procedure","volume":"78","author":"Lenz","year":"2011","journal-title":"Acta Chir. Orthop. Traumatol. Cechoslov."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1009","DOI":"10.1007\/s00113-012-2317-6","article-title":"Versorgung periprothetischer und periimplant\u00e4rer Frakturen","volume":"115","author":"Raschke","year":"2012","journal-title":"Unfallchirurg"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"988","DOI":"10.1016\/j.clinbiomech.2013.09.005","article-title":"Mechanical behavior of fixation components for periprosthetic fracture surgery","volume":"28","author":"Lenz","year":"2013","journal-title":"Clin. Biomech."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"S71","DOI":"10.1016\/j.injury.2013.10.027","article-title":"A biomechanical study on proximal plate fixation techniques in periprosthetic femur fractures","volume":"45","author":"Lenz","year":"2014","journal-title":"Injury"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1007\/s00264-012-1702-7","article-title":"Biomechanical performance of different cable and wire cerclage configurations","volume":"37","author":"Lenz","year":"2012","journal-title":"Int. Orthop."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1749","DOI":"10.1007\/s00264-015-2787-6","article-title":"Bicortical screw fixation provides superior biomechanical stability but devastating failure modes in periprosthetic femur fracture care using locking plates","volume":"39","author":"Gwinner","year":"2015","journal-title":"Int. Orthop."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1007\/s00132-013-2165-2","article-title":"Versorgung periprothetischer Frakturen","volume":"43","author":"Schliemann","year":"2014","journal-title":"Orthop\u00e4de"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1115\/1.2746369","article-title":"Fracture Toughness and Fatigue Crack Propagation Rate of Short Fiber Reinforced Epoxy Composites for Analogue Cortical Bone","volume":"129","author":"Chong","year":"2007","journal-title":"J. Biomech. Eng."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1196","DOI":"10.1007\/s10439-007-9284-z","article-title":"Fatigue Performance of Composite Analogue Femur Constructs under High Activity Loading","volume":"35","author":"Chong","year":"2007","journal-title":"Ann. Biomed. Eng."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1175","DOI":"10.1243\/09544119JEIM409","article-title":"Cancellous bone screw purchase: A comparison of synthetic femurs, human femurs, and finite element analysis","volume":"222","author":"Zdero","year":"2008","journal-title":"Proc. Inst. Mech. Eng. Part H J. Eng. Med."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1007\/s00264-010-1117-2","article-title":"Twenty-year results of the cementless Corail stem","volume":"35","author":"Vidalain","year":"2010","journal-title":"Int. Orthop."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1016\/j.clinbiomech.2018.12.001","article-title":"Periprosthetic fracture fixation of the femur following total hip arthroplasty: A review of biomechanical testing\u2014Part II","volume":"61","author":"Wang","year":"2018","journal-title":"Clin. Biomech."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1016\/j.arth.2010.04.009","article-title":"The effect of fixation technique on the stiffness of comminuted Vancouver B1 periprosthetic femur fractures","volume":"25","author":"Choi","year":"2010","journal-title":"J. Arthroplast."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1054\/arth.2000.4339","article-title":"Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem: A biomechanical study of 5 techniques","volume":"15","author":"Dennis","year":"2000","journal-title":"J. Arthroplast."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1849","DOI":"10.1016\/j.arth.2016.02.013","article-title":"Application of Far Cortical Locking Technology in Periprosthetic Femoral Fracture Fixation: A Biomechanical Study","volume":"31","author":"Moazen","year":"2016","journal-title":"J. Arthroplast."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1485","DOI":"10.1016\/j.arth.2014.02.017","article-title":"The Effect of Strut Allograft and Its Position on Vancouver Type B1 Periprosthetic Femoral Fractures: A Biomechanical Study","volume":"29","author":"Sariyilmaz","year":"2014","journal-title":"J. Arthroplast."},{"key":"ref_27","first-page":"373","article-title":"Comparison of fixation techniques in Vancouver type AG periprosthetic femoral fracture: A biomechanical study","volume":"50","author":"Korkmaz","year":"2015","journal-title":"Acta Orthop. Traumatol. Turc."},{"key":"ref_28","first-page":"234","article-title":"Double plating in Vancouver type B1 periprosthetic proximal femur fractures: A biomechanical study","volume":"35","author":"Gehweiler","year":"2016","journal-title":"J. Orthop. Res."},{"key":"ref_29","first-page":"150","article-title":"Periprosthetic fracture fixation in Vancouver B1 femoral shaft fractures: A biomechanical study comparing two plate systems","volume":"24","author":"Tiedemann","year":"2020","journal-title":"J. Orthop. Transl."},{"key":"ref_30","first-page":"47","article-title":"Biomechanical comparison of two angular stable plate constructions for periprosthetic femur fracture fixation","volume":"38","author":"Schulze","year":"2013","journal-title":"Int. Orthop."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"814","DOI":"10.1016\/j.clinbiomech.2015.06.008","article-title":"Interfragmentary lag screw fixation in locking plate constructs increases stiffness in simple fracture patterns","volume":"30","author":"Schaser","year":"2015","journal-title":"Clin. Biomech."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"933","DOI":"10.1016\/S0021-9290(97)00057-2","article-title":"Internal forces and moments in the femur during walking","volume":"30","author":"Duda","year":"1997","journal-title":"J. Biomech."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/j.clinbiomech.2010.09.002","article-title":"Periprosthetic fracture fixation of the femur following total hip arthroplasty: A review of biomechanical testing","volume":"26","author":"Moazen","year":"2011","journal-title":"Clin. Biomech."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1016\/0021-9290(95)00084-4","article-title":"Mechanical validation of whole bone composite femur models","volume":"29","author":"Cristofolini","year":"1996","journal-title":"J. Biomech."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"2658","DOI":"10.2106\/JBJS.F.01538","article-title":"Mortality after periprosthetic fracture of the femur","volume":"89","author":"Bhattacharyya","year":"2007","journal-title":"J. Bone Jt. Surg. Am."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"1283","DOI":"10.1016\/j.arth.2015.11.038","article-title":"Survivorship after Periprosthetic Femur Fracture: Factors Affecting Outcome","volume":"31","author":"Drew","year":"2015","journal-title":"J. Arthroplast."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"494","DOI":"10.5301\/HIP.2012.9760","article-title":"Clinical Outcome following Surgical Intervention for Periprosthetic Hip Fractures at a Tertiary Referral Centre","volume":"22","author":"Matharu","year":"2012","journal-title":"HIP Int."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"027","DOI":"10.1055\/s-0033-1333905","article-title":"Mortality after Periprosthetic Femur Fractures","volume":"26","author":"Streubel","year":"2013","journal-title":"J. Knee Surg."},{"key":"ref_39","first-page":"E62","article-title":"Biomechanical Evaluation for Mechanisms of Periprosthetic Femoral Fractures","volume":"70","author":"Rupprecht","year":"2011","journal-title":"J. Trauma Inj. Infect. Crit. Care"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1016\/j.injury.2009.01.003","article-title":"Indications and limitations of locked plating","volume":"40","author":"Tan","year":"2009","journal-title":"Injury"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1097\/BOT.0000000000000282","article-title":"Periprosthetic femur fractures","volume":"29","author":"Ricci","year":"2015","journal-title":"J. Orthop. Trauma"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"1256","DOI":"10.1016\/j.injury.2010.05.007","article-title":"Treatment of periprosthetic femoral fractures with two different minimal invasive angle-stable plates: Biomechanical comparison studies on cadaveric bones","volume":"41","author":"Konstantinidis","year":"2010","journal-title":"Injury"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1016\/j.clinbiomech.2015.02.006","article-title":"Working length of locking plates determines interfragmentary movement in distal femur fractures under physiological loading","volume":"30","author":"Schaser","year":"2015","journal-title":"Clin. Biomech."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"B11-9","DOI":"10.1016\/j.injury.2003.09.021","article-title":"Biomechanical testing of the LCP\u2014How can stability in locked internal fixators be controlled?","volume":"34","author":"Stoffel","year":"2003","journal-title":"Injury"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1186\/1749-799X-5-45","article-title":"The biomechanical analysis of three plating fixation systems for periprosthetic femoral fracture near the tip of a total hip arthroplasty","volume":"5","author":"Lever","year":"2010","journal-title":"J. Orthop. Surg. Res."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"S51","DOI":"10.1016\/S0020-1383(16)47009-9","article-title":"Managing Vancouver B1 fractures by cerclage system compared to locking plate fixation\u2014A biomechanical study","volume":"47","author":"Gordon","year":"2016","journal-title":"Injury"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1177\/0954411913501489","article-title":"Biomechanical analysis using infrared thermography of a traditional metal plate versus a carbon fibre\/epoxy plate for Vancouver B1 femur fractures","volume":"228","author":"Siddiqui","year":"2013","journal-title":"Proc. Inst. Mech. Eng. Part H J. Eng. Med."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1016\/j.arth.2011.08.019","article-title":"A Biomechanical Comparison of Periprosthetic Femoral Fracture Fixation in Normal and Osteoporotic Cadaveric Bone","volume":"27","author":"Demos","year":"2012","journal-title":"J. Arthroplast."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1097\/00005131-200103000-00005","article-title":"Fixation of Periprosthetic Femoral Shaft Fractures: A Biomechanical Comparison of Two Techniques","volume":"15","author":"Dennis","year":"2001","journal-title":"J. Orthop. Trauma"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1177\/2151458510397609","article-title":"Biomechanical Comparison of 2 Different Locking Plate Fixation Methods in Vancouver B1 Periprosthetic Femur Fractures","volume":"2","author":"Pletka","year":"2011","journal-title":"Geriatr. Orthop. Surg. Rehabil."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"875","DOI":"10.1007\/s00776-015-0735-3","article-title":"Periprosthetic femoral fracture fixation: A biomechanical comparison between proximal locking screws and cables","volume":"20","author":"Graham","year":"2015","journal-title":"J. Orthop. Sci."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"1068","DOI":"10.2106\/JBJS.F.01561","article-title":"Biomechanical Evaluation of Periprosthetic Femoral Fracture Fixation","volume":"90","author":"Zdero","year":"2008","journal-title":"J. Bone Jt. Surg."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1097\/01.bot.0000199119.38359.96","article-title":"Fixation of periprosthetic femoral shaft fractures associated with cemented femoral stems: A biomechanical comparison of locked plating and conventional cable plates","volume":"20","author":"Fulkerson","year":"2006","journal-title":"J. Orthop. Trauma"},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1016\/j.clinbiomech.2004.08.008","article-title":"A biomechanical study comparing cortical onlay allograft struts and plates in the treatment of periprosthetic femoral fractures","volume":"20","author":"Wilson","year":"2005","journal-title":"Clin. Biomech."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"1915","DOI":"10.1007\/s00264-012-1574-x","article-title":"The locking attachment plate for proximal fixation of periprosthetic femur fractures\u2014A biomechanical comparison of two techniques","volume":"36","author":"Lenz","year":"2012","journal-title":"Int. Orthop."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1016\/j.injury.2014.07.013","article-title":"Functional and radiological outcome of periprosthetic femoral fractures after hip arthroplasty","volume":"46","author":"Moreta","year":"2015","journal-title":"Injury"},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1097\/00003086-200403000-00012","article-title":"Periprosthetic Fractures Evaluation and Treatment","volume":"420","author":"Masri","year":"2004","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_58","first-page":"565","article-title":"Biomechanical Characterization of an Osteoporotic Artificial Bone Model for the Distal Femur","volume":"26","author":"Hoffmeier","year":"2010","journal-title":"J. Biomater. Appl."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"773","DOI":"10.1016\/S0021-9290(01)00015-X","article-title":"Structural properties of a new design of composite replicate femurs and tibias","volume":"34","author":"Heiner","year":"2001","journal-title":"J. Biomech."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1115\/1.2401178","article-title":"The Biomechanics of Human Femurs in Axial and Torsional Loading: Comparison of Finite Element Analysis, Human Cadaveric Femurs, and Synthetic Femurs","volume":"129","author":"Papini","year":"2006","journal-title":"J. Biomech. Eng."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1016\/1350-4533(95)00031-3","article-title":"Stress and strain distribution within the intact femur: Compression or bending?","volume":"18","author":"Taylor","year":"1996","journal-title":"Med. Eng. Phys."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/11\/3\/892\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T22:16:08Z","timestamp":1760134568000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/11\/3\/892"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,8]]},"references-count":61,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2022,2]]}},"alternative-id":["jcm11030892"],"URL":"https:\/\/doi.org\/10.3390\/jcm11030892","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,8]]}}}