{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,4]],"date-time":"2026-10-04T19:06:51Z","timestamp":1791140811197,"version":"4.1.0"},"reference-count":33,"publisher":"MDPI AG","issue":"14","license":[{"start":{"date-parts":[[2022,7,17]],"date-time":"2022-07-17T00:00:00Z","timestamp":1658016000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Agencia Estatal de Investigaci\u00f3n, Ministerio de Ciencia e Innovaci\u00f3n of the Spanish government","award":["PID2020-114582RB-I00\/AEI\/10.13039\/501100011033"],"award-info":[{"award-number":["PID2020-114582RB-I00\/AEI\/10.13039\/501100011033"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>The objective of this prospective, randomized, double-masked study was to compare the contrast sensitivity and quality of vision of patients bilaterally implanted with the following six different presbyopia correcting intraocular lenses (IOLs): SV25T0 (n = 19), ATLISA 809M (n = 18), ATLISA TRI 839MP (n = 19), ZKB00 (n = 20), ZLB00 (n = 20) and Symfony ZXR00 (n = 20). For comparison purposes, 36 patients were implanted with a monofocal lens (ZA9003). Contrast sensitivity was assessed binocularly at distance under photopic, mesopic and mesopic plus glare conditions, and at near under photopic conditions. Quality of vision was explored in terms of photic phenomena and spectacle independence. Overall, the monofocal lens offered better contrast sensitivity, under all illumination conditions, and less occurrence and intensity of photic phenomena. Amongst the multifocal IOL (MIOL) designs, the extended depth of focus Symfony ZXR00 provided better contrast sensitivity than the other MIOLs, particularly at intermediate and high spatial frequencies. Up to 40% and 50% of patients implanted with MIOLs reported glare and halos, respectively. The SV25T0 resulted in less occurrence and intensity of halos. The evaluation of photic phenomena and contrast sensitivity under different illumination conditions may reflect real-life, visually challenging situations, and thus provide insightful information to assist ophthalmic surgeons when selecting the best intraocular lens for their patients.<\/jats:p>","DOI":"10.3390\/jcm11144150","type":"journal-article","created":{"date-parts":[[2022,7,17]],"date-time":"2022-07-17T22:57:06Z","timestamp":1658098626000},"page":"4150","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["Far and Near Contrast Sensitivity and Quality of Vision with Six Presbyopia Correcting Intraocular Lenses"],"prefix":"10.3390","volume":"11","author":[{"given":"Miguel \u00c1.","family":"Gil","sequence":"first","affiliation":[{"name":"Ophthalmology Department, Santa Creu and Sant Pau Hospital, Sant Quint\u00ed, 89, E08041 Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Consuelo","family":"Var\u00f3n","sequence":"additional","affiliation":[{"name":"Department of Optics and Optometry, Universitat Polit\u00e8cnica de Catalunya, Violinista Vellsol\u00e0, 37, E08222 Terrassa, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4770-8992","authenticated-orcid":false,"given":"Genis","family":"Cardona","sequence":"additional","affiliation":[{"name":"Department of Optics and Optometry, Universitat Polit\u00e8cnica de Catalunya, Violinista Vellsol\u00e0, 37, E08222 Terrassa, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jos\u00e9 A.","family":"Buil","sequence":"additional","affiliation":[{"name":"Ophthalmology Department, Santa Creu and Sant Pau Hospital, Sant Quint\u00ed, 89, E08041 Barcelona, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2022,7,17]]},"reference":[{"key":"ref_1","unstructured":"Ryan, C., and Lewis, J.M. (2022, May 24). Computer and Internet Use in the United States: 2015, Available online: https:\/\/www.census.gov\/content\/dam\/Census\/library\/publications\/2017\/acs\/acs-37.pdf."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/S0169-8141(96)00026-1","article-title":"Effects of screen color combination, work-break schedule, and workplace on VDT viewing distance","volume":"20","author":"Shieh","year":"1997","journal-title":"Int. J. Ind. Ergonom."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"2070","DOI":"10.1016\/j.jcrs.2009.07.010","article-title":"Visual acuity from far to near and contrast sensitivity in eyes with a diffractive multifocal intraocular lens with low addition power","volume":"35","author":"Hayashi","year":"2009","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/S0161-6420(03)00862-5","article-title":"Visual performance with multifocal intraocular lenses. Mesopic contrast sensitivity under distance and near conditions","volume":"111","author":"Bueno","year":"2004","journal-title":"Ophthalmology"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1016\/S0886-3350(02)01648-6","article-title":"Distance and near contrast sensitivity function after multifocal intraocular lens implantation","volume":"29","year":"2003","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"257","DOI":"10.3928\/1081597X-20080301-07","article-title":"Visual function with bilateral implantation of monofocal and multifocal intraocular lenses, a prospective, randomized, controlled trial","volume":"24","year":"2008","journal-title":"J. Refract. Surg."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"430","DOI":"10.1016\/j.jcrs.2006.10.051","article-title":"Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens","volume":"33","author":"Alfonso","year":"2007","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"175","DOI":"10.5301\/EJO.2011.8371","article-title":"Visual acuity, contrast sensitivity, subjective quality of vision, and quality of life with 4 different multifocal IOLs","volume":"22","author":"Gil","year":"2012","journal-title":"Eur. J. Ophthalmol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1016\/j.jcrs.2011.08.034","article-title":"Visual function comparison of 2 aspheric multifocal intraocular lenses","volume":"38","author":"Alfonso","year":"2012","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1177\/112067211002000112","article-title":"Visual acuity and contrast sensitivity function after accommodative and multifocal intraocular lens implantation","volume":"20","author":"Mesci","year":"2010","journal-title":"Eur. J. Ophthalmol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"146","DOI":"10.3928\/1081597X-20170217-01","article-title":"Extended depth of focus IOLs, The next chapter in refractive technology?","volume":"33","author":"Rocha","year":"2017","journal-title":"J. Refract. Surg."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"228","DOI":"10.3928\/1081597X-20180125-01","article-title":"Visual performance of a new extended depth-of-focus intraocular lens compared to a distance-dominant diffractive multifocal intraocular lens","volume":"34","author":"Savini","year":"2018","journal-title":"J. Refract. Surg."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"460","DOI":"10.5301\/ejo.5000935","article-title":"Comparison of visual outcomes after bilateral implantation of extended range of vision and trifocal intraocular lenses","volume":"27","author":"Arumburu","year":"2017","journal-title":"Eur. J. Ophthalmol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1038\/s41433-018-0221-1","article-title":"Functional assessment of a new extended depth-of-focus intraocular lens","volume":"33","author":"Savini","year":"2019","journal-title":"Eye"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.ophtha.2016.09.039","article-title":"Special Report, American Academy of Ophthalmology Task Force Consensus Statement for Extended Depth of Focus Intraocular Lenses","volume":"124","author":"MacRae","year":"2017","journal-title":"Ophthalmology"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"463","DOI":"10.3928\/1081-597X-19980701-14","article-title":"Normalized contrast sensitivity values","volume":"14","author":"Krueger","year":"1998","journal-title":"J. Refract. Surg."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1097\/00004397-200343020-00004","article-title":"Contrast sensitivity and functional vision","volume":"43","author":"Ginsburg","year":"2003","journal-title":"Int. Ophthalmol. Clin."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1016\/j.jcrs.2012.12.002","article-title":"Multifocal intraocular lenses in cataract surgery, literature review of benefits and side effects","volume":"39","author":"Nuijts","year":"2013","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"282","DOI":"10.5301\/ejo.5001030","article-title":"Visual outcomes after progressive apodized diffractive intraocular lens implantation","volume":"28","year":"2018","journal-title":"Eur. J. Ophthalmol."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/j.jcrs.2017.11.011","article-title":"Comparative analysis of visual outcomes with 4 intraocular lenses, monofocal, multifocal, and extended range of vision","volume":"44","author":"Pedrotti","year":"2018","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_21","first-page":"6165493","article-title":"Through-focus vision performance and light disturbances of 3 new intraocular lenses for presbyopia correction","volume":"2018","author":"Ribeiro","year":"2018","journal-title":"J. Ophthalmol."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1508","DOI":"10.1016\/j.ophtha.2008.04.017","article-title":"One-year outcomes with new-generation multifocal intraocular lenses","volume":"115","author":"Cillino","year":"2008","journal-title":"Ophthalmology"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1016\/j.ophtha.2014.10.002","article-title":"Quality of vision after bilateral multifocal intraocular lens implantation, a randomized trial\u2013\u2013AT LISA 809M versus AcrySof ReSTOR SN6AD1","volume":"122","author":"Maurino","year":"2015","journal-title":"Ophthalmology"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/S0008-4182(01)80040-5","article-title":"Contrast sensitivity and depth of focus with aspheric multifocal versus conventional monofocal intraocular lens","volume":"36","author":"Kamlesh","year":"2001","journal-title":"Can. J. Ophthalmol."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"672","DOI":"10.1016\/j.jcrs.2008.11.061","article-title":"Visual acuity comparison of 2 models of bifocal aspheric intraocular lenses","volume":"35","author":"Alfonso","year":"2009","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1393","DOI":"10.2147\/OPTH.S139909","article-title":"Comparison between bilateral implantation of a trifocal intraocular lens and blended implantation of two bifocal intraocular lenses","volume":"11","author":"Vilar","year":"2017","journal-title":"Clin. Ophthalmol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1016\/j.jcrs.2006.10.035","article-title":"Quality of vision after cataract surgery after Tecnis Z9000 intraocular lens implantation, effect of contrast sensitivity and wavefront aberration improvements on the quality of daily vision","volume":"33","author":"Denoyer","year":"2007","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1016\/j.ajo.2007.12.023","article-title":"Spherical aberration and contrast sensitivity in eyes implanted with aspheric and spherical intraocular lenses, a comparative study","volume":"145","author":"Tzelikis","year":"2008","journal-title":"Am. J. Ophthalmol."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1001","DOI":"10.1016\/S0886-3350(99)00408-3","article-title":"Initial experience with a refractive multifocal intraocular lens in a Japanese population","volume":"26","author":"Sasaki","year":"2000","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_30","first-page":"3357","article-title":"Test-retest reliability of the CSV-1000 contrast test and its relationship to glaucoma therapy","volume":"35","author":"Pomerance","year":"1994","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"1033","DOI":"10.1016\/j.jcrs.2007.02.037","article-title":"Functional outcomes after implantation of Tecnis ZM900 and Array SA40 multifocal intraocular lenses","volume":"33","author":"Mester","year":"2007","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1016\/j.jcrs.2017.03.037","article-title":"Visual performance after bilateral implantation of 2 new presbyopia-correcting intraocular lenses, Trifocal versus extended range of vision","volume":"43","author":"Monaco","year":"2017","journal-title":"J. Cataract Refract. Surg."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.jcrs.2015.11.037","article-title":"Evaluation of visual outcomes and patient satisfaction after implantation of a diffractive trifocal intraocular lens","volume":"42","author":"Mendicute","year":"2016","journal-title":"J. Cataract Refract. Surg."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/11\/14\/4150\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T23:52:27Z","timestamp":1760140347000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/11\/14\/4150"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,17]]},"references-count":33,"journal-issue":{"issue":"14","published-online":{"date-parts":[[2022,7]]}},"alternative-id":["jcm11144150"],"URL":"https:\/\/doi.org\/10.3390\/jcm11144150","relation":{},"ISSN":["2077-0383"],"issn-type":[{"value":"2077-0383","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7,17]]}}}