{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T02:13:39Z","timestamp":1760148819315,"version":"build-2065373602"},"reference-count":61,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2023,6,14]],"date-time":"2023-06-14T00:00:00Z","timestamp":1686700800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JCM"],"abstract":"<jats:p>Introduction: Fracture reduction and fixation of distal femur fractures are technically demanding. Postoperative malalignment is still commonly reported after minimally invasive plate osteosynthesis (MIPO). We evaluated the postoperative alignment after MIPO using a traction table with a dedicated femoral support. Methods: The study included 32 patients aged 65 years or older with distal femur fractures of all AO\/OTA types 32 (c) and 33 (except 33 B3 and C3) and peri-implant fractures with stable implants. Internal fixation was achieved with MIPO using a bridge-plating construct. Bilateral computed tomography (CT) scans of the entire femur were performed postoperatively, and measurements of the uninjured contralateral side defined anatomical alignment. Due to incomplete CT scans or excessively distorted femoral anatomy, seven patients were excluded from analyses. Results: Fracture reduction and fixation on the traction table provided excellent postoperative alignment. Only one of the 25 patients had a rotational malalignment of more than 15\u00b0 (18\u00b0). Conclusions: The surgical setup for MIPO of distal femur fractures on a traction table with a dedicated femoral support facilitated reduction and fixation, resulting in a low rate of postoperative malalignment, despite a high rate of peri-implant fractures, and could be recommended for surgical treatment of distal femur fractures.<\/jats:p>","DOI":"10.3390\/jcm12124044","type":"journal-article","created":{"date-parts":[[2023,6,15]],"date-time":"2023-06-15T02:03:19Z","timestamp":1686794599000},"page":"4044","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Using a Traction Table for Fracture Reduction during Minimally Invasive Plate Osteosynthesis (MIPO) of Distal Femoral Fractures Provides Anatomical Alignment"],"prefix":"10.3390","volume":"12","author":[{"given":"Martin","family":"Paulsson","sequence":"first","affiliation":[{"name":"Department of Orthopaedics, Sahlgrenska University Hospital, 41345 Gothenburg, Sweden"},{"name":"Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, 41345 Gothenburg, Sweden"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carl","family":"Ekholm","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Sahlgrenska University Hospital, 41345 Gothenburg, Sweden"},{"name":"Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, 41345 Gothenburg, Sweden"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0777-2399","authenticated-orcid":false,"given":"Roy","family":"Tranberg","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Sahlgrenska University Hospital, 41345 Gothenburg, Sweden"},{"name":"Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, 41345 Gothenburg, Sweden"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6534-1242","authenticated-orcid":false,"given":"Ola","family":"Rolfson","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Sahlgrenska University Hospital, 41345 Gothenburg, Sweden"},{"name":"Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, 41345 Gothenburg, Sweden"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0529-7723","authenticated-orcid":false,"given":"Mats","family":"Geijer","sequence":"additional","affiliation":[{"name":"Department of Radiology, Sahlgrenska University Hospital, 41345 Gothenburg, Sweden"},{"name":"Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, 41345 Gothenburg, Sweden"},{"name":"Department of Clinical Sciences, Lund University, 22185 Lund, Sweden"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2023,6,14]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1007\/s00264-017-3665-1","article-title":"Population-based epidemiology and incidence of distal femur fractures","volume":"42","author":"Elsoe","year":"2018","journal-title":"Int. Orthop."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1016\/j.otsr.2014.06.004","article-title":"Epidemiology of distal femur fractures in France in 2011\u201312","volume":"100","author":"Pietu","year":"2014","journal-title":"Orthop. Traumatol. Surg. Res."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"A7","DOI":"10.1016\/S0020-1383(97)90110-8","article-title":"Minimally invasive plate osteosynthesis and vascularity: Preliminary results of a cadaver injection study","volume":"28","author":"Farouk","year":"1997","journal-title":"Injury"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1186\/1749-799X-8-43","article-title":"Clinical outcomes of locked plating of distal femoral fractures in a retrospective cohort","volume":"8","author":"Hoffmann","year":"2013","journal-title":"J. Orthop. Surg. Res."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"e867","DOI":"10.5435\/JAAOS-D-17-00706","article-title":"Modern Implant Options for the Treatment of Distal Femur Fractures","volume":"27","author":"Hake","year":"2019","journal-title":"J. Am. Acad. Orthop. Surg."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1097\/00005131-200409000-00006","article-title":"Treatment of distal femur fractures using the less invasive stabilization system: Surgical experience and early clinical results in 103 fractures","volume":"18","author":"Kregor","year":"2004","journal-title":"J. Orthop. Trauma"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1007\/s00402-004-0779-x","article-title":"Use of the less invasive stabilization system (LISS) in patients with distal femoral (AO33) fractures: A prospective multicenter study","volume":"125","author":"Schutz","year":"2005","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1016\/j.injury.2010.08.024","article-title":"Lower limb malrotation following MIPO technique of distal femoral and proximal tibial fractures","volume":"42","author":"Buckley","year":"2011","journal-title":"Injury"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1016\/j.injury.2017.01.019","article-title":"Malalignment after minimally invasive plate osteosynthesis in distal femoral fractures","volume":"48","author":"Kim","year":"2017","journal-title":"Injury"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1007\/s00068-015-0595-8","article-title":"Does MIPO of fractures of the distal femur result in more rotational malalignment than ORIF? A retrospective study","volume":"42","author":"Lill","year":"2016","journal-title":"Eur. J. Trauma Emerg. Surg."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/j.knee.2022.04.004","article-title":"Comminuted periprosthetic distal femoral fractures have greater postoperative extension malalignment","volume":"36","author":"Sharma","year":"2022","journal-title":"Knee"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1097\/BOT.0000000000002482","article-title":"Locked Lateral Plating Versus Retrograde Nailing for Distal Femur Fractures: A Multicenter Randomized Trial","volume":"37","author":"Dunbar","year":"2023","journal-title":"J. Orthop. Trauma"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1302\/2633-1462.32.BJO-2021-0191.R1","article-title":"How does intraoperative fracture malalignment affect postoperative function and bone healing following distal femoral fracture?: A retrospective multicentre study","volume":"3","author":"Kuwahara","year":"2022","journal-title":"Bone Jt. Open."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"S2","DOI":"10.1016\/j.injury.2018.10.001","article-title":"Predicting the failure in distal femur fractures","volume":"49","author":"Peschiera","year":"2018","journal-title":"Injury"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1007\/s00402-013-1705-x","article-title":"The effect of rotational deformity on patellofemoral parameters following the treatment of femoral shaft fracture","volume":"133","author":"Yildirim","year":"2013","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1243","DOI":"10.1007\/s00590-013-1289-8","article-title":"Rotational malalignment after closed intramedullary nailing of femoral shaft fractures and its influence on daily life","volume":"24","author":"Karaman","year":"2014","journal-title":"Eur. J. Orthop. Surg. Traumatol."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1097\/00005131-200411000-00002","article-title":"The effects of femoral shaft malrotation on lower extremity anatomy","volume":"18","author":"Gugenheim","year":"2004","journal-title":"J. Orthop. Trauma"},{"key":"ref_18","first-page":"e23889","article-title":"Use of Traction Table for Reducing Complex Distal Femur Fractures: A Technical Trick","volume":"14","author":"Wong","year":"2022","journal-title":"Cureus"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1016\/j.otsr.2012.10.014","article-title":"Distal femur fractures. Surgical techniques and a review of the literature","volume":"99","author":"Ehlinger","year":"2013","journal-title":"Orthop. Traumatol. Surg. Res."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1016\/j.otsr.2010.11.004","article-title":"Minimally-invasive internal fixation of extra-articular distal femur fractures using a locking plate: Tricks of the trade","volume":"97","author":"Ehlinger","year":"2011","journal-title":"Orthop. Traumatol. Surg. Res."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"21514593211055889","DOI":"10.1177\/21514593211055889","article-title":"Immediate full weight-bearing versus partial weight-bearing after plate fixation of distal femur fractures in elderly patients. A randomized controlled trial","volume":"12","author":"Paulsson","year":"2021","journal-title":"Geriatr. Orthop. Surg. Rehabil."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/BOT.0000000000001063","article-title":"Fracture and dislocation classification compendium-2018","volume":"32","author":"Meinberg","year":"2018","journal-title":"J. Orthop. Trauma"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"668","DOI":"10.5435\/00124635-201011000-00004","article-title":"Traction table-related complications in orthopaedic surgery","volume":"18","author":"Flierl","year":"2010","journal-title":"J. Am. Acad. Orthop. Surg."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1007\/s00064-005-1127-1","article-title":"Percutaneous compression plating for intertrochanteric fractures. Surgical technique, tips for surgery, and results","volume":"17","author":"Peyser","year":"2005","journal-title":"Oper. Orthop. Traumatol."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"S161","DOI":"10.1016\/j.otsr.2016.06.025","article-title":"Minimally invasive internal fixation of distal femur fractures","volume":"103","author":"Pietu","year":"2017","journal-title":"Orthop. Traumatol. Surg. Res."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"695","DOI":"10.1097\/BOT.0b013e31821d7a56","article-title":"Pitfalls in the application of distal femur plates for fractures","volume":"25","author":"Collinge","year":"2011","journal-title":"J. Orthop. Trauma"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A guideline of selecting and reporting intraclass correlation coefficients for reliability research","volume":"15","author":"Koo","year":"2016","journal-title":"J. Chiropr. Med."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1016\/S0020-1383(03)00191-8","article-title":"Retrograde intramedullary nailing in distal femoral fractures\u2014Results in a series of 46 consecutive operations","volume":"35","author":"Handolin","year":"2004","journal-title":"Injury"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1016\/j.otsr.2015.11.004","article-title":"Side-to-side variation in normal femoral morphology: 3D CT analysis of 122 femurs","volume":"102","author":"Dimitriou","year":"2016","journal-title":"Orthop. Traumatol. Surg. Res."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"e96","DOI":"10.1097\/BOT.0000000000001648","article-title":"Assessing femoral rotation: A survey comparison of techniques","volume":"34","author":"Marchand","year":"2020","journal-title":"J. Orthop. Trauma"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1302\/0301-620X.100B7.BJJ-2017-1601.R1","article-title":"Which factors influence proximal femoral asymmetry?: A 3D CT analysis of 345 femoral pairs","volume":"100","author":"Laumonerie","year":"2018","journal-title":"Bone Jt. J."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"775","DOI":"10.3109\/17453678208992291","article-title":"Femoral neck angles: A specimen study with special regard to bilateral differences","volume":"53","author":"Reikeras","year":"1982","journal-title":"Acta Orthop. Scand."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1148\/radiol.12111903","article-title":"Femoral antetorsion: Comparing asymptomatic volunteers and patients with femoroacetabular impingement","volume":"263","author":"Sutter","year":"2012","journal-title":"Radiology"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1097\/BOT.0000000000001028","article-title":"Is contralateral templating reliable for establishing rotational alignment during intramedullary stabilization of femoral shaft fractures? A study of individual bilateral differences in femoral version","volume":"32","author":"Croom","year":"2018","journal-title":"J. Orthop. Trauma"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1016\/j.injury.2004.08.009","article-title":"Technique for closed reduction of femoral shaft fracture using an external support device","volume":"36","author":"Shezar","year":"2005","journal-title":"Injury"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"591","DOI":"10.2106\/00004623-196749040-00001","article-title":"Supracondylar Fracture of the Adult Femur: A STUDY OF ONE HUNDRED AND TEN CASES","volume":"49","author":"Neer","year":"1967","journal-title":"JBJS"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"S74","DOI":"10.1016\/j.injury.2020.02.034","article-title":"Biomechanical analysis of the stability of anterograde reamed intramedullary nails in femoral spiral fractures","volume":"51","author":"Herrera","year":"2020","journal-title":"Injury"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1177\/2151458513496254","article-title":"Clinical Outcomes of Distal Femoral Fractures in the Geriatric Population Using Locking Plates With a Minimally Invasive Approach","volume":"4","author":"Doshi","year":"2013","journal-title":"Geriatr. Orthop. Surg. Rehabil."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"166","DOI":"10.5435\/JAAOS-D-16-00142","article-title":"Internal Fixation of Osteoporotic Bone","volume":"26","author":"Grant","year":"2018","journal-title":"J. Am. Acad. Orthop. Surg."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1007\/s12306-014-0343-y","article-title":"Results of treatment of distal extra: Articular femur fractures with locking plates using minimally invasive approach\u2014Experience with 25 consecutive geriatric patients","volume":"99","author":"Khursheed","year":"2015","journal-title":"Musculoskelet. Surg."},{"key":"ref_41","first-page":"1425","article-title":"Fixation of distal femoral fractures with the Less Invasive Stabilization System: A minimally invasive treatment with locked fixed-angle screws","volume":"65","author":"Kolb","year":"2008","journal-title":"J. Trauma"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"1187","DOI":"10.1016\/j.injury.2009.03.012","article-title":"The role of LISS (less invasive stabilisation system) in the treatment of peri-knee fractures","volume":"40","author":"Liu","year":"2009","journal-title":"Injury"},{"key":"ref_43","first-page":"e23617","article-title":"Evaluation of the Results of Minimally Invasive Plate Osteosynthesis Using a Locking Plate in the Treatment of Distal Femur Fractures","volume":"14","author":"Abdelmonem","year":"2022","journal-title":"Cureus"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1055\/s-0039-1683443","article-title":"Minimally Invasive Plate Osteosynthesis for Periprosthetic and Interprosthetic Fractures Associated with Knee Arthroplasty: Surgical Technique and Review of Current Literature","volume":"32","author":"Borade","year":"2019","journal-title":"J. Knee Surg."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1007\/s11420-010-9194-8","article-title":"Evidence for success with locking plates for fragility fractures","volume":"7","author":"Cornell","year":"2011","journal-title":"HSS J."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"S3","DOI":"10.1016\/S0020-1383(16)47001-4","article-title":"Failure of fracture fixation in osteoporotic bone","volume":"47","author":"Augat","year":"2016","journal-title":"Injury"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"711","DOI":"10.5435\/JAAOS-D-15-00175","article-title":"Stress Modulation of Fracture Fixation Implants","volume":"24","author":"Beltran","year":"2016","journal-title":"J. Am. Acad. Orthop. Surg."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"S35","DOI":"10.1016\/j.injury.2007.08.009","article-title":"Locking plate technology and its role in osteoporotic fractures","volume":"38","author":"Miranda","year":"2007","journal-title":"Injury"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1097\/BOT.0000000000000302","article-title":"Management of distal femur fractures with modern plates and nails: State of the art","volume":"29","author":"Beltran","year":"2015","journal-title":"J. Orthop. Trauma"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1097\/01.bot.0000438368.44077.04","article-title":"Dynamic Fixation of Distal Femur Fractures Using Far Cortical Locking Screws: A Prospective Observational Study","volume":"28","author":"Bottlang","year":"2014","journal-title":"J. Orthop. Trauma"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1097\/00005131-200409000-00004","article-title":"Biomechanical evaluation of the less invasive stabilization system, angled blade plate, and retrograde intramedullary nail for the internal fixation of distal femur fractures","volume":"18","author":"Zlowodzki","year":"2004","journal-title":"J. Orthop. Trauma"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1097\/01.blo.0000224008.19798.91","article-title":"Assessment of fragment micromotion in distal femur fracture fixation with RSA","volume":"448","author":"Duffy","year":"2006","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1016\/j.ocl.2013.01.006","article-title":"Biomechanical considerations for surgical stabilization of osteoporotic fractures","volume":"44","author":"Bogunovic","year":"2013","journal-title":"Orthop. Clin. N. Am."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"S34","DOI":"10.1016\/j.injury.2017.08.036","article-title":"Surgical treatment of osteoporotic fractures: An update on the principles of management","volume":"48","author":"Yaacobi","year":"2017","journal-title":"Injury"},{"key":"ref_55","first-page":"89","article-title":"Aspects of internal fixation of fractures in porotic bone. Principles, technologies and procedures using locked plate screws","volume":"72","author":"Perren","year":"2005","journal-title":"Acta Chir. Orthop. Traumatol. Cechoslov."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1111\/os.12449","article-title":"Comparison of Less Invasive Stabilization System Plate and Retrograde Intramedullary Nail in the Fixation of Femoral Supracondylar Fractures in the Elderly: A Biomechanical Study","volume":"11","author":"Du","year":"2019","journal-title":"Orthop. Surg."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"e153","DOI":"10.3928\/01477447-20150305-50","article-title":"Far cortical locking screws in distal femur fractures","volume":"38","author":"Adams","year":"2015","journal-title":"Orthopedics"},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1097\/BOT.0000000000000593","article-title":"Mechanical Construct Characteristics Predisposing to Non-union After Locked Lateral Plating of Distal Femur Fractures","volume":"30","author":"Rodriguez","year":"2016","journal-title":"J. Orthop. Trauma"},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"1757","DOI":"10.1007\/s11999-011-1870-6","article-title":"2010 Mid-America Orthopaedic Association Physician in Training Award: Healing Complications Are Common After Locked Plating for Distal Femur Fractures","volume":"469","author":"Henderson","year":"2011","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"2907","DOI":"10.1007\/s00264-018-3881-3","article-title":"Lateral locked plating for distal femur fractures by low-energy trauma: What makes a difference in healing?","volume":"42","author":"Kim","year":"2018","journal-title":"Int. Orthop."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"1031","DOI":"10.1007\/s00590-022-03212-3","article-title":"Using Blumensaat\u2019s line to determine the sagittal alignment of the distal femur","volume":"33","author":"Yazdi","year":"2022","journal-title":"Eur. J. Orthop. Surg. Traumatol."}],"container-title":["Journal of Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2077-0383\/12\/12\/4044\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T19:54:35Z","timestamp":1760126075000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2077-0383\/12\/12\/4044"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,14]]},"references-count":61,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2023,6]]}},"alternative-id":["jcm12124044"],"URL":"https:\/\/doi.org\/10.3390\/jcm12124044","relation":{},"ISSN":["2077-0383"],"issn-type":[{"type":"electronic","value":"2077-0383"}],"subject":[],"published":{"date-parts":[[2023,6,14]]}}}